Multifunction Altimeter/Variometer AV1

Similar documents
ECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark

MODEL 6600 Rev. B4 USER'S MANUAL LAVERSAB INC., 505 GILLINGHAM LANE. SUGAR LAND TX (281) FAX: (281)

Pilot s Operating Handbook

DBI version 002 User Manual US version Free Balloon Flight Instrument

MODEL 6500 Rev. E USER'S MANUAL

MODEL 6500 Rev. F4 USER'S MANUAL LAVERSAB INC., 505 GILLINGHAM LANE SUGAR LAND TX, (281) FAX: (281)

Revision Number Revision Date Insertion Date/Initials 1 st Ed. Oct 26, 00 2nd Ed. Jan 15, 08

TL-3524 USER`S MANUAL

ALT-1. Introduction. Precision Encoding Altimeter and Vertical speed indicator (VSI) Operating Manual English 1.09

VISO Manual. LARSEN & BRUSGAARD Mosevej Kirke Hyllinge, Denmark Phone: Fax:

DIVER NAVIGATION BOARD. RJE International, Inc. RJE International Feb 1, TAC-100D Revision 10

Altimeter and Compass Watch Instruction Manual

DRILL MONITOR DM-100 OPERATIONS MANUAL

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

S-TEC. Pilot s Operating Handbook

WARNING! Jump Number Main Window Exit Altitude Alti-Meter Mode Deployment Altitude Speed-Meter Mode...

PTG100 Precision Test Gauge

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

PS-425 Pitot-Static/Air Data Tester

WARNING! FAILURE TO FOLLOW ALL WARNINGS, INSTRUCTIONS, AND REQUIRED PROCEDURES MAY RESULT IN SERIOUS INJURY AND DEATH.

Manufactured by: AAA

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

ASX-1. Introduction. 1 Features. Encoding aviation altimeter with serial output and airspeed Indicator (ASI) Operating Manual English 1.

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

Stratomaster Smart Single

The ALT-5 is a 2 1/4 (57mm) sunlight readable encoding altimeter and a wide range vertical speed indicator.

DMA AERO MPS38 VER 1.0 DMA- AERO. Ground Support Test Equipment. MPS 38 Air Data Test Set User Manual

The ALT-5 is a 2 1/4 sunlight readable encoding altimeter and a wide range vertical speed indicator.

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Hand-held pressure calibrator with integrated pump Model CPH6600

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual

USER MANUAL. m 2 multi AAD. It could save you... More than you think EN

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

TABLE OF CONTENTS TABLE OF CONTENTS HOW TO USE THIS MANUAL 3 OPERATING THE WATCH CARE & MAINTENANCE 4 WATCH FUNCTIONS 5-6 KEYS AND THEIR FUNCTIONS 7-8

The Military CYPRES Quick Guide For Operators

WELCOME TO THE REVOLUTION

In Vivo Scientific, LLC INSTRUCTION MANUAL

MPS45 AIR DATA TEST SET

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

MicroTim XB. User Manual. Precision Digital Barometric Altimeter / Barometer / VSI. Document Revision 1.0 Firmware Version 3.0

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Sweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.

SAI-340 Pilot Guide Osuna Road NE Suite 711 Albuquerque, NM Rev 3

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

RAM 4021-DPX Operation Manual

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

OMNISPORT 2000 SWIMMING QUICK REFERENCE

New product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

PM105 PRESSURE METER USER S MANUAL

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

Digital Vacuum Regulator

Digitool Instruments AB DBI3 US User Manual Free Balloon Flight Instrument

The ASV-1 is a 2 1/4 sunlight readable encoding altimeter, airspeed and wide range vertical speed indicator.

BI-680 Online Dissolved Oxygen Controller Instruction Manual

La Crosse Technology, Ltd. Page 1

The ASV-2 is a 3 1/8 sunlight readable encoding altimeter, airspeed and wide range vertical speed indicator.

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

ECL Comfort 110, application 131 (valid as of software version 2.00)

1.0 General Guide WARNING!

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

CircuFlow Quick Setup Guide

TAC-100A DIVER NAVIGATION BOARD OPERATIONS MANUAL. RJE International, Inc. RJE International, October 20, TAC-100A Revision 3

LM6 LEATHER MOISTURE METER

1)! DO NOT PROCEED BEYOND THIS MARK

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

DIVER NAVIGATION BOARD

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Service Test Unit for ROSS Proportional Valves RESK

ACV-10 Automatic Control Valve

The Univentor 1250 Anaesthesia Unit

AA100 Acoustic Actuator

RAM 4021 Operation Manual

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

STX 165 Operation. Data Knob Enter Pushbutton. Power/Mode Control. Select Knob Ident Pushbutton. VFR Pushbutton

M104 Series: Digital Manometer: 0.1 % of Full Scale

DIVER NAVIGATION BOARD

Digital Vacuum Regulator

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

AA GWR Water Retention Meter for Accurate Measurement of Water Retention

Field 1. Barometer Alarm Symbol. Field 2. Barometer Trend Indicator. Altimeter/Barometer Alarm Symbol Field 4. Altimeter Function Indicator

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

ENVIRONMENTAL INSTRUMENTS, LLC

Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Pneumatic high-pressure controller Model CPC7000

User s Guide Temperature Sensor Converter TSC-599

Version-E E100930

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Walk-O-Meter User Manual

WATCH COLLECTION NG701 SERIES INSTRUCTION MANUAL

AUTOMATIC FILM APPLICATOR MICROPROCESSOR CONTROLLED. Operating Instructions for the

Aladin ONE (Matrix) User Manual

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

The ALT-7 is a 3 1/8 (80mm) sunlight readable encoding altimeter and a wide range vertical speed indicator.

Transcription:

Multifunction Altimeter/Variometer AV1 Revision#3.0, 21/11/2014 For firmware version 2.2

Page intentionally left blank

SECTIONS MECHANICAL INSTALLATION ELECTRICAL INSTALLATION USE OF THE INSTRUMENT INSTRUMENT SETTINGS TECHNICAL SPECIFICATIONS

Introduction Thank you for purchasing a Flybox product. We hope it fully satisfy you and makes your flights pleasant and secure. Developing AV1, our intent was to create a compact and lightweight digital altimeter, easy to install and quick to consult. SYMBOLS USED IN THE MANUAL NOTE: Used to highlight important informations. CAUTION: Used to warn the user and indicate a potentially hazardous situation or improper use of the product. WARNING: Used to indicate a dangerous situation that can cause personal injury or death if the instruction is disregarded. AV1 - User s manual

Important notices & warnings NOTE: Keep this manual in the aircraft. This document must accompany the instrument in the event of change of ownership. NOTE: This device is intended for installation onto non type certified aircraft only, because it has no aviation certifications. Refer to your local aviation authorities to check if this device may be installed in your aircraft. CAUTION: Read entirely this manual before installing the instrument in your aircraft, and follow the installation and operating instructions described here. CAUTION: Using this instrument over the maximum allowable ranges can cause malfunction or wrong indications. CAUTION: Microel s.r.l. reserves the right to change or improve its products. Information in this document is subject to changes without notice. AV1 - User s manual

Index INDEX SECTION 1 - Mechanical installation 1.1 - Mechanical installation.... 7 Pressure port connection.... 7 1.2 - Dimensions.. 8 SECTION 2 - Electrical installation 2.1 - Electrical installation....... 10 SECTION 3 - Use of the instrument 3.1 - Use of the instrument...... 12 SEZIONE 4 - Instrument settings 4.1 - Functions menu...... 14 4.2 - Setup menu..... 17 4.3 - Edit airports............ 19 SEZIONE 5 - Technical specifications.... 21 Warranty...... 22 AV1 - User s manual

Mechanical installation SECTION 1 1.1 MECHANICAL INSTALLATION 1) The AV1 fits in a standard 3 1/8 (80mm) panel cutout. 2) It's recommended to choose a position that permits optimal visibility. PRESSURE PORT CONNECTION: Connect the pipe fitting on the back of the instrument to a static air pressure lines; the furnished pipe fitting is suitable for pipe with internal diameter of 5 mm. AV1 - User s manual 7

Dimensions 1.2 DIMENSIONS Front view Dimensions in millimeters. 8 AV1 - User s manual

Dimensions Side view Dimensions in millimeters. AV1 - User s manual 9

Electrical installation SECTION 2 2.1 ELECTRICAL INSTALLATION On the back of the AV1 altimeter there is a 15-pole male connector; with the AV1 is already furnished the corresponding 15-pole female connector. The connections are the followings: 15-pole female connector, view from wiring side. 10 AV1 - User s manual

Electrical installation Connections detail: 1= +12V Main supply. 2= GND auxiliary backup battery (if present). 3= GND (not used). 4= GND for audio out. 5= GND (not used). 6= reserved. 7= reserved. 8= GND Main supply. 9= +12V auxiliary backup battery (if present). 10= reserved. 11= Altitude alert alarm out (300mA max). Connect the load (for example a lamp indicator) between out and +12V. 12= Low-level audio out for intercom (it's recommended to use shielded cable). 13= reserved. 14= reserved. 15= Mode C encoder out (open-collector) - OPTIONAL - actually not used. NOTE: Insert a 1A circuit breaker or fuse to the power lead. (+12V). CAUTION: Voltage peaks on the supply line that exceeds the operating limits can damage the device. AV1 - User s manual 11

Use of the instrument SECTION 3 3.1 USE OF THE INSTRUMENT Using the AV1 altimeter is simple and intuitive; all the functions or settings are activated/modified using the knob (rotary switch) on the front panel: for example it can be rotated to increment or decrement a value or can be pushed to confirm, as explained in the following chapters. At startup the display briefly shows the software version, then the main screen will appear with the altimeter and variometer: CURRENT ALTITUDE UNIT OF MEASURE PRESSURE REFERENCE VARIOMETER (GRAPHICAL INDICATION) VARIOMETER (NUMERICAL INDICATION) The altimeter section includes the current altitude, the unit of measure and the pressure reference with its unit of measure (millibar/hpa or inches of mercury). Rotating the knob changes the value of the pressure reference and consequently it also changes the altitude. 12 AV1 - User s manual

Use of the instrument The variometer section includes both numerical and graphical indications; the amplitude of the bar varies in proportion to the vertical speed: the upper bar indicates a positive vertical speed (climb) while the lower bar indicates a negative vertical speed (descend). The unit of measure of the variometer is feet/minute or m/s, depending on what is selected. CAUTION: Before using the altimeter for the first time you must set-up the unit of measure for the altitude and for the pressure (read chapter 4.2 Setup menu ); the default settings are Feet (altitude) and mbar (pressure). AV1 - User s manual 13

Functions menu SECTION 4 4.1 FUNCTIONS MENU To enter in the functions menu press the knob for at least one second: DONE: exit from the main menu and return to the altimeter/variometer screen. REFERENCE: Set the pressure reference mode (QNH, QFE, QNE); press and then rotate the knob to choose the desired mode: choose QNH to manually adjust the pressure reference rotating the knob (when in main screen with altimeter and variometer). choose QFE to automatically set the pressure reference so that the altimeter shows zero. choose QNE to automatically set the standard pressure reference 1013.25hPa. Press the knob again to confirm. 14 AV1 - User s manual

Functions menu AIRPORTS LIST: allows you to choose the airport for automatic QNH and elevation setting. After pressing the knob a screen appears that allows you to select the initial letter of the airport and then you can select the airport from the list. LIGHT: Turns on/off the display backlight. FLIGHT PROFILE: shows the altimetric profile screen. This screen displays the altimetric profile of the last recorded flight (to begin a recording see the option Capture flight ). Rotate the knob to slide the profile with the cursor; the line below the graphic shows the time elapsed from the start of the recording and the altitude reached at that moment. If the profile is divided into more screens it is indicated by an arrow on the right corner (as in the example picture); when the cursor reaches the end of the screen it automatically change to the next one. Flight profile screen. ALTIMETER ALERT: enable/disable the altitude alert and set the limits. Press the knob to display the alert screen where you can modify the upper and the lower limits; there is also the on/off option to activate/deactivate the alert (turn the knob clockwise to activate or counterclockwise to deactivate). AV1 - User s manual 15

Functions menu When the altitude exceeds this limit the AV1 activates a visual indication (blinking yellow LED) and an audio tone (on the intercom audio out). Furthermore the display shows the indication CLIMB or DESCEND (CLIMB when the altitude is below the lower limits and DESCEND when the altitude is over the upper limit). Altitude alert screen. CAPTURE FLIGHT: start/stop the altimetric profile recorder. To start a recording press the knob and choose if you want to begin a new recording (by selecting NEW ) or if you want to continue the last recording (by selecting CONTINUE ). If the recording is already started, the only option available is STOP to stop it. SETUP: enter in the setup menu (see next chap.). 16 AV1 - User s manual

Setup menu 4.2 SETUP MENU Setup menù - page 1 Setup menù - page 2 DONE: Exit from the setup menu. CONTRAST: adjust the LCD contrast. ALTIMETER UNIT: Select which unit of measure will be used for the altitude (Feet or Meters); change also the unit for the variometer (Feet/min or Meters/sec). PRESSURE UNIT: Select the unit of measure for the pressure reference: hpa(mbar) or inches of mercury. CALIBRATION: The altimeter has been calibrated at the factory and doesn't need further adjustments, but if you notice that the indication is not accurate you can follow these steps to calibrate the instrument: Read the current sea level barometric pressure from an altimeter/barometer used as reference. Adjust the value that appears in Calibration so that it coincides with the pressure read from the reference; to modify this value you must press and hold the knob for 5 seconds (the background changes from black to white) and then you can rotate to adjust the value. Press again the knob to confirm the value and exit from the calibration. AV1 - User s manual 17

Setup menu VARIO SCALE: Select the scale for the graphical indication of the variometer; the range is 500 to 8000 Ft/min. CAPTURE INTERVAL: The altimetric graphic profile is drawn storing the altitude at fixed time intervals; this parameter allows you to select the time interval between two altitude samplings (value can be from 1 to 60 seconds). The maximum number of samplings is 8900, so if you choose an interval of 1 second the graphic can store a 8900s flight (2hours and 28 minutes). When the memory is full MEMORY FULL appears on the display (no more recordings will be made). EDIT AIRPORTS: Allows you to modify the airports elevation database (see next chapter). AUDIO VOLUME: Adjust the volume for the audio out. 18 AV1 - User s manual

Edit Airports 4.3 EDIT AIRPORTS This function allows you to modify, insert or delete the airports present in the database. After selecting Edit Airports it appears a new screen that permits to create a new airport (by selecting NEW ) or to modify an existing one (by selecting the initial letter of the airport and then selecting the airport from the list that appears). To delete the selected airport press DELETE ; another confirmation is required and pressing YES will delete the airport, pressing NO returns it to the setup menu without deleting the airport. To modify the selected airport press MODIFY ; the screen that appears allows you to add a character (by selecting the character and pressing the knob) or delete the last character (by selecting DEL ). The maximum length of the name is 14 characters. When you have finished press END. AV1 - User s manual 19

Edit Airports The next screen allows you to adjust the altitude: rotate the knob and press it when you have reached the right altitude for the airport. To confirm the updating of the airport the display shows MODIFIED and returns to the setup menu. To insert new airports follow the same steps described above for modifying the existing airports. 20 AV1 - User s manual

Technical specifications SECTION 5 5.1 TECHNICAL SPECIFICATIONS - Graphic LCD with backlight and coated glass, dimensions 58x31mm. - Standard mounting 3 1/8 (80mm). - Anodized aluminium case. - Dimensions: 83 x 83 x 36 mm. - Weight: 230g. - Altimeter range: -1000 ~ +25000 Feet. - Altimeter resolution: 10 feet. - Variometer range: +/- 8000 Ft/min. - Variometer resolution: 10 Ft/min. - Operational temperature range: -20 ~ +70 C. - Supply voltage: 10 ~ 30 V=. - Supply current: 80mA. - Audio level: 2Vpp (with 10Kohm load). - Alarm out: open-collector, 300mA max current, active low. AV1 - User s manual 21

WARRANTY: This product is warranted to be free from defects for a period of 12 months from the user invoice date. The warranty only cover the manufacture's defects; shall not apply to product that has been improper installed, misused or incorrect maintenance, repaired or altered by non-qualified person. Data Versioni Descrizione 12/2007 2.3 First release 11/2014 3.0 Layout update WARNING: All photos, data, drawings, instruments layouts, technical solutions and data representation you find in this document or watching at FLYBOX instruments working and/or you can access by means of any other media, including web sites, are sole property of MICROEL s.r.l., cannot be copied or imitate without a written permission of MICROEL s.r.l. itself and are protected by law, even by means of extended international copyright and/or specific patents deposited. Any infringement of this statement and of MICROEL s.r.l. intellectual property will be prosecuted. 2014 Microel s.r.l. all rights reserved. 22 AV1 - User s manual

Page intentionally left blank

MICROEL s.r.l. Via Mortara 192-194 27038 Robbio (PV) - ITALY Tel +39-0384-670602 - Fax +39-0384-671830 www.flyboxavionics.it