Programmable Submersible Level Transmitters

Similar documents
Parametrable / Programmable Pressure Transmitter

Programmable pressure and temperature transmitters PTM/RS485

Programmable pressure and temperature transmitters PTM/RS485

ATM.ECO - Analog Pressure Transmitter

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

ATM - Analog Pressure Transmitter

ATM.1ST/Ex - High Precision Transmitter

ATM.ECO/IS - Analog Transmitter with Temperature compensation

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

ATM/Ex - Analog Pressure Transmitter

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10

JUMO dtrans p30 Pressure Transmitter

Submersible pressure sensor High-performance Model LH-20

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

MB610 Industrial Pressure Transmitter

MB260/MB261/MB264 Submersible Level Transmitter

Precision pressure sensor Basic version Model CPT6020

3.0 Pressure Transmitter Selection

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

86BSD Backside Digital Output

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Pneumatic high-pressure controller Model CPC7000

Gas density monitor With integrated transmitter Model GDM-100-TI

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

Expert Hydrostatic Level Transmitters

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Pneumatic high-pressure controller Model CPC7000

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Pressure Calibrators. Series PC..., PM...

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Pressure transmitters EMP 2

EPRB-2 Pressure Transducer

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

High-speed pressure sensor Model CPT6140

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

SITRANS P measuring instruments for pressure

ED 701 Hygenic Pressure Transmitter

JUMO MAERA. Level probes Types , , , Installation Instructions T94Z001K000 V4.00/EN/

Hand-held pressure calibrator with integrated pump Model CPH6600

NivuBar Plus II

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Datasheet May, 2017 HPSD 4000 Pressure Transducer 1/5. Applications

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

SonoMeter 30 Energy Meters

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Type S-10, S-11 General Purpose Pressure Transmitters

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

OPTIBAR P 1010 C Technical Datasheet

Electronic gas volume corrector model DGVC-04

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

SENSORS Pressure CALDARO

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

UNIK 5600/5700. Marine Certified Pressure Sensing Platform. High Quality. Features. Bespoke as Standard. Expertise. bhge.com

MANUAL KPS Pressure Control Valve

2/2-Way Solenoid Control Valve

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400

Pressure Transmitter P41

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

How to specify a product. Process Sensors and Mechanical Instruments

Model 601CV. Mass Flow Controller. Product Features:

Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Sensing. Applications. Features

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Instruction Manual Differential Pressure Transmitter

ASDX Series Silicon Pressure Sensors

MPM426W/436W Submersible Level Transmitter

PC10 Piezoresistive Silicon Pressure Sensor

BAPI Pressure Line of Products - FAQs

Digital pressure gauge Model CPG500

Pressure Measurement Single-range transmitters for general applications

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Instruction Manual Differential Pressure Transmitter

FAS-W. Features. Applications. Automatic condensation hygrometer

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Industrial pressure controller Model CPC4000

Digital pressure gauges

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

TH-1800-T TRX-700-CNG Converter

INDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable

PRODUCT CATALOGUE DIGITAL GAUGES

Transcription:

Programmable Submersible Level Transmitters PTM/N/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available as multi-parameter sensor (pressure & temperature) Fast customization thanks to configurable product design Stainless steel and titanium version for use in acidic or otherwise aggressive media Available with lightning protection Version: 05.04.2017 www.sensorsone.com 1

Technical Specifications PRESSURE MEASURING RANGE (MH2O) 1... 5 > 5... 20 > 20...250 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure, (1) > 200 bar > 200 bar > 200 bar Accuracy, (2), (± % FS) 0.25 0.1 0.1 Total error, (3), (4) (± % FS) -10...50 C, (typ./max.) -25...85 C, (typ./max.) 0.15 / 0.3 ( 200 mbar: 0.3 / 0.6) 0.65 / 0.7 ( 200 mbar: 0.65 / 0.8) 0.15 / 0.3 0.15 / 0.3 0.65 / 0.7 0.55 / 0.7 Long term stability, (5) 0.5% FS/< 4 mbar 0.2% FS/< 4 mbar 0.1% FS/< 0.2% FS (1) Transducer (2) Zero based accuracy according to DIN 16086, incl. hysteresis and repeatability at ambient temperature (3) Total error including accuracy and temperature influences at maximum signal span (16 ma) (4) Active compensated (5) 1 year (typ. / max.), the long term stability can be improved by ageing (burn-in) the sensor TEMPERATURE MEASURING RANGE Standard, (1), (2) -10...50 C Lower end of range (2) -25 C Upper end of range (2) 85 C Accuracy ± 2 C (1) Available active compensated only (2) Depending on temperature range of the active compensation TEMPERATURE RANGE Operating temperature -5...80 C (1) Process temperature -5...80 C (1) Storage temperature -10...80 C (1) For operating temperature > 50 C, PE or FEP cable must be used www.sensorsone.com 2

ELECTRICAL SPECIFICATIONS Output Digital Protocol Analog Resolution Digital output Analog output Output adjustable RS485 Modbus RTU 4...20 ma 0.01% FS 0.025% FS 4 ma -5% FS...105% FS 20 ma -5% FS...105% FS Span 25% FS...110% FS ( 0.1 mh2o) Low pass filter Power supply Supply influence Circuit diagram 0.1 / 1 / 10 / 30 Hz (standard: 30 Hz) 9...30 V DC < 0.1% FS Load resistance Load influence < 0.1% FS www.sensorsone.com 3

QUALIFICATIONS Description Level Typical interferences EN 60068-2-6 Vibration 4 G (4...100 Hz / ± 3.2 mmpp) EN 60068-2-27 Shock 100 G (impulse duration 6 ms) EN 55022 Emission, class B < 30 dbµv/m (0.03...1 GHz) EN 61000-4-2 Electrostatic discharge 4 kv contact / 8 kv air EN 61000-4-3 Irradiated RF 10V/m (0.08...1 GHz) Radio sets, wireless phones EN 61000-4-4 Transients (burst) 2 kv Motors, valves EN 61000-4-5 Surge 10 ka (8 / 20 µs), (1) Lightning EN 61000-4-6 Conducted RF 10 V (0.15...80 MHz, 3 s) Frequency converters (1) Only with optional surge (lightning) protection PHYSICAL SPECIFICATIONS Materials Stainless steel (316L / 1.4435), titanium (Gr. 2), (1) Transducer Stainless steel (316L / 1.4435), titanium (Gr. 2), (1) Housing Stainless steel (316L / 1.4404), titanium (Gr. 2) Seals Cable Weight (2) Viton (Standard), EPDM, Kalrez, NBR PUR, FEP, PE 157 g (1) Hastelloy (C-276) on request (2) Specification for a PTM/N/RS485, closed, without cable www.sensorsone.com 4

Equipment OVERVIEW 10.00.0091 Accessories overview INTERFACE 101138 PTM - Interface SOFTWARE 101224 PC Software V1.50 Additional documents MANUALS Article number Description 10.00.0079 DEB003 Configuration software 10.00.0089 DEB005 User manual OPERATING AND SAFETY INSTRUCTIONS Article number 10.00.0137 DMM009 www.sensorsone.com 5

Ordering information Type Pressure type Pressure measuring range Process connection Electrical connection Output signal Accuracy Temperature range Option 1 Option 2 Option 3 PTM/N/RS485 44 Gauge 1 Absolute (vacuum) 2 Any pressure measuring ranges between 0...1 mh2o and 0...250 mh2o available Offset, special adjustment 99 Closed (Fig. 1) 55 Closed, (1.4435), for ACS certification (Fig. 1) 59 Open, (Fig. 2) 56 G 1/4 M (Fig. 3) 11 G 1/2 M (Fig. 3) 13 Custmized 99 PE cable, IP 68 (2), (3) 13 PUR cable, black, IP 68 (2), (4) 15 FEP cable, black, IP 68 (2) 21 PVC cablel, blue, IP 68 (2), (5) 14 Customized 99 X. XXXX. XXXX. XX. XXX RS485 / 4...20mA (pressure) 62 RS485 / 4...20 ma (pressure) with surge protection 64 RS485 / 4...20mA (pressure and temperature) (6) 65 RS485 / 4...20mA (pressure and temperature) with surge protection (6) ± 0.25 % FS ( 5 mh2o) 1 ± 0.1 % FS (> 5 mh2o) 2-5...50 C compensated (allowed process temperature: -5 50 C) -5...80 C compensated (allowed process temperature: -5...80 C) Cutting ring connection G1/2 M Strain relief Special oil filling: Anderol Food Electronics packed in gel: Gauge pressure Electronics packed in gel: Absolute pressure Ballast weight 1.4435 Active compensated Version titanium (without ballast weight) Seals: Viton (standard) XX 66 4 5 G C D B E K U www.sensorsone.com 6

Seals: EPDM Seals: Kalrez (Level) Seals: NBR (ACS) Humidity filter element for gauge versions (only for PUR and PE cable) S T H Z (2) Please specify the required cable length and medium (3) Suitable for drinking water (food approved) (4) For operating temperature > 50 C, PE or FEP cable must be used (5) ACS Certification (6) Temperature output only with option "active compensated" available www.sensorsone.com 7

Technical drawings www.sensorsone.com 8