SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Similar documents
Halsey Taylor Owners Manual

Halsey Taylor Owners Manual

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

Halsey Taylor Owners Manual

Owners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual STOP!

Installation/Care/Use Manual

PAGE (Rev. A - 06/17)

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

Owners Manual Models 4430BF3, 4430BF2 & 4430BF1 Floor Mounted Tri-Level Bottle Filling Tubular Fountain

Installation and Use Manual

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Pressure Dump Valve Service Kit for Series 2300 Units

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Pressure Balance Trim

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

LK4420BFFR - FTN, 4420BFFR - FTN. Owners Manual

VOLUMATIC WATER REGULATOR

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

Pressure Dump Valve Service Kit for Series 3000 Units

INSTALLATION INSTRUCTIONS

NGP-250/500 Nitrogen Generator Quick Start Guide

Installation Instructions

Floor Drinking Systems

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Anti-flood device Model B-1

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

Booster Pump PB4-60 Replacement Kits

Model VR6 System. Installation, Operation & Maintenance

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

Installation Instructions

D05 Pressure Regulating Valves

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Carter Option X Valve connector assembly. Maintenance manual

Installation Instructions

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

CO2 Tank Conversion Kit P.N , P.N , and P.N

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

DS05C,D,G Dial Set Pressure Regulating Valves

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Medical Gas Control Panel

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

RD(H)20/25 Pressure-Reducing Regulator User Manual

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

Installation Troubleshooting Maintenance Instructions Installation / Start-up

D05T Compact Design Pressure Regulating Valves

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

AIR/OVER HYDRAULIC JACK 20 TON

Operation Manual Air Saver Unit ASV5000 Series

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Anderson Greenwood Series 400 Diaphragm Pilot Operated Safety Relief Valves. Installation and Maintenance Instructions for

Installation, Operation, and Maintenance Manual

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

LRS(H)4 Pressure-Reducing Regulator User Manual

Installing ASI Umbilical Delivery Systems

INSTALLATION & MAINTENANCE INSTRUCTION

Shut-Off Valves and Valve Boxes

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

OPERATING AND MAINTENANCE MANUAL

DS06D,G Dial Set Pressure Regulating Valve

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Thank you for purchasing your new Empire Reloader B Sound-Activated 3-Speed Paintball Hopper!

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

UltRo Dual Flow Reverse Osmosis Water System

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Operating Instructions Models and Hydrostatic Test Pumps

Speed control assembly model A-1

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

INSTALLATION GUIDELINES

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

INSTALLATION GUIDELINES

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

Air Intake Snorkel Kit

TECHNICAL DATA. Page 1 of 12

Combination Air Valve

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

INSTRUCTION MANUAL. Gas Salamander

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Operation Manual Piston Sensed Gas Pressure Regulators

TECHNICAL INSTRUCTIONS

PRODUCT OPERATING MANUAL

Transcription:

TM INSTALLATION, CARE & USE MANUAL SWIRLFLO Refrigerated fountains with FLEXI-GUARD TM INSTALLER! CAUTION: Review these instructions before beginning installation. Be sure that installation conforms to all plumbing, electrical and other applicable codes.! WARNING: When installation is complete, ensure these instructions are left in the plastic bag provided inside the installed unit for future reference.! WARNING: Service to be performed by authorized service personnel only. NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in an electrolysis effect occurring in the fountain. This may result in water which has a metallic taste to it or has a noticeable increase in the metallic content of the water. When inspecting plumbing circuit, remember the line may be grounded some distance from the installation, and may occur outside the building or area in which the unit is being installed. This condition can be avoided (in most cases) by using recommended materials during installation. Any drain fittings provided by the installer should be made of plastic which will electronically isolate the fountain from the remainder of the building s plumbing circuits. Page 1

Model LRPB8C LEGEND A = 1/4 O.D. Tube - Water Outlet Connection B = 3/8 O.D. Tube - Water Inlet Connection C = 1-1/4 Waste Tube D = ELECTRICAL INLET Figure 1 - Rough-in Dimensions Page 2

REQUIRED TOOLS AND MATERIALS These tables show special tools and/or additional materials (not provided) which are necessary to complete installation of these units: Special Tools Item Description Quantity NONE Figure 2 - Chiller Installation Additional Materials Item Description Quantity 1 Unplated copper inlet pipe 2 Service Stop TO BUBBLER 1. Install chiller: Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and side panel. Slide chiller onto the shelf and position it to the left as per dimensions in Figure 1. CHILLER OUTLET 27 28 CHILLER INLET Note: Building construction must allow for adequate air flow on both sides, top and back of chiller. A minimum of 4 (102mm) on both sides and top is required. See chiller installation for additional instructions. 2. Make water supply connections. Install a shut-off valve and union connection to building water supply (valve and union not provided). Turn on water supply and flush the line thoroughly. TO BUBBLER Figure 3 - ERPB Tube Routing 3. ERPB Models: Make connection between remote chiller and building supply line. Inlet port is marked on the chiller (1/4 O.D. copper tube). Bend the copper tube (provided) at an appropriate length from chiller to opening in frame. Install the in-line strainer (provided with chiller) by pushing it until it reaches a positive stop, approximately 3/4 (19mm) on the marked chiller inlet port. Connect building supply line to strainer. (See Figure 3) Caution: DO NOT SOLDER tubes inserted into the strainer as damage to o-rings may result. 27 CHILLER OUTLET 27 WATER INLET 4. LRPB Models: Mount filter head assembly to side of chiller (See Figure 4). Make connections between filter and building supply line (3/8 O.D. tube not porvided). Inlet port is marked on the chiller (1/4 O. D. copper tube). Install a 1/4 x 1/4 union (provided) on the marked chiller inlet port. Insert the 1/4 poly tubing (provided) into the fitting on filter and connect the union to the chiller. (See Figure 4) Caution: DO NOT SOLDER tubes inserted into the strainer as damage to o-rings may result. Figure 4 - LRPB Tube Routing Page 3

29, 30 5. Hang the upper panel on the mounting frame hanger. Be sure that the panel is engaged with hanger at the top of frame before releasing it. Align holes in the panel with holes in the mounting frame. Install two (2) #10-24 x 5/8 (16mm) screws (Item 29 - Figure 5) in holes and tighten securely. 6. Install the fountain. Remove the screw (Item 30) from cover plate (Item 14) and slide cover plate toward basin. Mount the fountain to the upper panel and frame with (4) 5/16 x 1 (25mm) long bolts (Item ), bracket (Item 36) and nuts (Item 35) provided. Tighten securely. Brackets (Item 36) must be installed as shown to properly support fountain. (See Figure 6) 7. Attach waste tube (1-1/4 O.D.) to 1-1/4 O.D. slip trap (provided by others). Figure 5 - Upper Panel Installation 34 8. ERPB Models: Make connections between remote chiller outlet tube and fountain. Outlet port is marked on the chiller (1/4 O.D. copper tube). Install a 1/4 x 1/4 union (provided) on the marked chiller outlet port. Insert the 1/4 poly tubing coming from the fountain into the union. Turn on the water supply and check for leaks. 16 39 38 View From Rear Figure 6 - Fountain Installation 31 CAUTION: DO NOT SOLDER tubes inserted into the strainer as damage to o-rings may result. LRPB Models: Make connections between remote chiller outlet tube and fountain. Outlet port is marked on the chiller (1/4 O.D. copper tube). Install a 1/4 x 1/4 union (provided) on the marked chiller outlet port. Insert the 1/4 poly tubing coming from the fountain into the union. CAUTION: DO NOT SOLDER tubes inserted into the strainer as damage to o-rings may result. 9. These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above 105 PSIG, a pressure regulator must be installed in the supply line. CAUTION: Any damage caused by connecting these products to a supply line with pressure lower than 20 PSIG or higher than 105 PSIG IS NOT covered under warranty. 10. Make electrical connections to the chiller. See chiller instructions. 11. Check stream height from bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, remove push button (Item 17 - Figure 11) and adjust the screw on the regulator (Item 19 - Figure 11). To remove push button, remove set screw from bottom of sleeve (Item 33). Insert a small punch in screw hole and push up while grasping the push buttom and pull forward removing the push button. Clockwise adjustment will raise stream height and counterclockwise movement will lower stream height. For best adjustment stream should hit basin approximately 6-1/2 from the bubbler. Reassemble push button by pushing in on button until the push button catches in the sleeve. Reinstall the setscrew (Item 33) in the sleeve (Item 15). Figure 7 - Lower Panel Installation 12. Mount lower panel. Loosen the two (2) #10-24 x 5/8 (16mm) screws (Item 29 - Figure 6) at frame bottom lip. Slide upper tongue of lower panel under lower edge of already installed upper panel. Tighten previously loosened screws securely. (See Figure 7) Page 4

7 7 1 3, 5, 6 8 2 4, 5, 6 8 Basin Basin 9 9 FLEXI-GUARD BUBBLER DETAIL FLEXI-GUARD STREAMSAVER BUBBLER DETAIL NOTE: When installing replacement bubbler and pedestal, tighten nut (Item 7) only to hold parts snug in position. Do Not Overtighten. 10 11 Basin 12 VANDAL RESISTANT BUBBLER DETAIL Figure 8 - Bubbler Details Page 5

2 7 When provided 1 6 4 3 5 Figure 9 - Filter Assembly WaterSentry Filter Detail WATERSENTRY FILTER PARTS LIST (See Fig. 9) ITEM NO. PART NO. DESCRIPTION 1 2 3 4 5 6 7 51294C 70792C 70823C 70822C 51299C 70818C 22490C Filter Head Assy. Screw #8-18 x.75 PH Fitting - Superseal 3/8 (10 mm) Fitting - Superseal 1/4 (6 mm) Filter Assy Elbow - 3/8 (10mm) Bracket Page 6

See Fig. 8 25 13 23 See Fig. 8 14 24 34 16 37 15 Figure 10 - Fountain Body Assembly 37 18 40 17 19 21 20 22 36 Figure 11 - Push Button Assembly Page 7

1/4" O.D. TUBE WATER INLET TO COOLER 3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY BUILDING WATER INLET Installation Package The components for installation are packed in three separate boxes, regardless of the type of unit being installed. The boxes contain the following: NOTE: WATER FLOW DIRECTION SERVICE STOP (NOT FURNISHED) Figure 12 Water Supply Connections Box No. 1: Wall Frame(s) Box No. 2: Remote Chiller, ECH8 Box No. 3: Fountain Arm and Panels Additional materials, as noted in the Parts List, are also shipped in these boxes. 1 2 3 4 5 6 7 8 9 10A 10B 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 27 28 29 30 31 33 34 35 36 37 38 39 40 56073C 98502C 40319C 40608C 50171C 50314C 56011C 55997C 75580C 98118C 98481C 1002740560 15009C 550011 55000944 45767C 28343C 45781C 45847C 45848C 50986C 61313C 15005C 56163C 45769C 45768C 56092C 70683C 55996C 28382C 28947C 833C 111008343890 704C 38417001 75560C 756C 70817C 70020C 28395C 75671C PARTS LIST ITEM NO. PART NO. DESCRIPTION Bubbler Assy Bubbler Assy (Stream Saver) Fitting - Orifice Fitting - Orfice (Stream Saver) O-Ring Orifice - Flow Straightener Housing Assembly Pedestal Bubbler Locknut Bubbler Assembly VR Bubbler Assy. VR StreamSaver Gasket - Black.68 x 1.03 VR Nipple - Bubbler VR Basin - Swirlflow Lower Shell Fountain Body Cover Plate Sleeve Pin - Push Button Push Button Holder - Regulator Regulator Retaining Nut Gasket - Drain Assy - Drain/Tailpipe Drain - Plug 1-1/2 Poly Tubing (Cut To Length) Fitting - Union 1/4 x 1/4 Strainer (Provided With Chiller) Back Panel Back Panel (Green Spec) Lower Panel Screw - #10-24 x.62 HHMS Screw - #8- x.38 THSM Screw - #8-18 x.37 HHSM Screw - 5/16-18 x 1.00 HHMS Setscrew - #10- x.13 Fttng - Elbow 1/4 x 1/4 Nut - Hex 5/16-18 Bracket - Support Spring - Push Button TROUBLESHOOTING & MAINTENANCE Orifice Assembly: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice by poking with a small round file not over 1/8 diameter, or using a small diameter wire.! CAUTION: DO NOT file or cut orifice material. Stream Regulator: If orifice is clean, regulate flow as in Step 11 of the installation instructions. If replacement is necessary, see parts list for correct regulator part number. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing. (See Figure 13) To insert tubing, push tube straight into fitting until it reaches a positive stop (approximately 3/4 ). Figure 13 Quick Connect Fittings REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.0.6640 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.3.0620 ELKAY MANUFACTURING COMPANY 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.8484 Page 8