RADIOLOGY/ FLUOROSCOPY 15 RAD-CHECK PLUS X-RAY EXPOSURE METER

Similar documents
Victoreen and

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

Exradin Ion Chambers. What attributes make Exradin the smart choice? EXRADIN Ion Chambers

Heavy Duty Dissolved Oxygen Meter

Exposure System Selection

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

User Manual PTW-DensiX. D / Di/Zi

Chapter 9 Human Use of Radiation Producing Equipment

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000


OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Pneumatic high-pressure controller Model CPC7000

Mass Flowmeters. Mass Flowmeters for Gases

Pneumatic high-pressure controller Model CPC7000

628 Differential Pressure Decay Leak Tester

HumiSys HF High Flow RH Generator

Hand-held pressure calibrator with integrated pump Model CPH6600

Proton Therapy QA Tools

Datasheet: K-30 ASCII Sensor

Technical Information Conducal CLY421

UNDERSTANDING, ACCELERATED

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Nuclear Associates

KERN EG/EW Version /02

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

The Univentor 1250 Anaesthesia Unit

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

Autocalibration Systems For In Situ Oxygen Analyzers

SSL. Smart Valve Positioner.

Columbus Instruments

Airox Supportair Ventilator

Relative Dosimetry. Photons

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Radiation Producing Machines Radiation Safety Training for X-ray Diffraction Units

E X R A D I N. Parallel Plate Ion Chambers User Manual DOC #

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Pool and Spa. Water Testing

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

ACV-10 Automatic Control Valve

Autocalibration Systems for In Situ Oxygen Analyzers

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

ANZAI AZ-733VI. Respiratory Gating System. since 1976

Quick Installation Guide Doc nr.: C Date:

Zoubir Ouhib Lynn Cancer Institute

Precision pressure sensor Basic version Model CPT6020

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Additel 761 Automated Pressure Calibrators

Larry A. DeWerd, Ph.D., FAAPM UW ADCL & Dept. of Medical Physics University of Wisconsin

Additel 780 Series Pressure Controller

THERMAL MASS FLOW MEASUREMENT FOR GASES

SSR. Smart Valve Positioner.

DPC-30 DPC-100. Reference Manual

OEM Manual. MODEL ½ Digit DRUM SCALE

Installation and Operation Manual

THE UNIVENTOR 400 ANAESTHESIA UNIT

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

Pedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

KEG PUMP. Range of Electric Keg Pumps

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Mass Flow Controllers

ADT 761 Automated Pressure Calibrator

Robotic Pool Cleaners

BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

Optical Dissolved Oxygen Meter

Digital deadweight tester Model CPD8500

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Model EXAxt AV550G. Averaging Oxygen Analyzer

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

DIGITAL AUTOMATIC TYRE INFLATOR

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

TSE Blood Pressure Monitor Invasive series

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Everest XLG3 VideoProbe

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Model Description

Optical Dissolved Oxygen Meter

13 QUALITY ASSURANCE OF A LINEAR ACCELERATOR 13.1 COLLIMATOR ISOCENTER, JAWS, LIGHT FIELD VS INDICATORS, COLLIMATOR ANGLE INDICATORS.

Field size and depth dependence of wedge factor for internal wedge of dual energy linear accelerator

PHOENIX L300i Best-in-class Helium Leak Detectors

Dissolved Oxygen/Temp Waterproof Tester

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

BUBBLER CONTROL SYSTEM

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

[Instruments for vacuum measurement, checking and adjustment] 3

Additel 761 Automated Pressure Calibrators Selection Guide

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

The Royal Australian and New Zealand College of Radiologists. FRANZCR Examination Part I Radiation Oncology. Radiotherapeutic Physics.

KMT Waterjet Systems Inc.

AIR FLOW CALIBRATORS Single Sensor Designs

Chapter I Standard application in photon dosimetry José Guilherme Pereira Peixoto Maria da Penha Potiens

Transcription:

RADIOLOGY/ FLUOROSCOPY 15 RAD-CHECK PLUS X-RAY EXPOSURE METER Proven Rad-Check technology specifically designed to provide you with the ultimate in versatility and cost-effective operation. Fast and easy to use! Battery operation and built-in detector eliminate setup time. Measures dose up to 2 R; dose rate up to 20 R/min. Energy response is ± 5% from 30 to 150 kvp for the RAD-CHECK PLUS internal chamber. Optional remote chambers for mammographic and cine imaging systems. Extremely compact...6'' x 6 1 /4'' x 2 3 /4'' high; weighs only 18 oz. RAD-CHECK PLUS can perform: Entrance skin exposure measurements (ESE). Fluoroscopy exposure measurements. Exposure checks; radiographic (mr/mas). Beam quality; Half Value Layer (HVL). mas reciprocity; ma Station Checks... Plus many others, depending on the remote external chambers used.

Automatic Reset After Exposure: There are no long cables (when the internal ionization chamber is used) or remote reset switches. Data accumulated during a prior measurement can be included in or eliminated from the next measurement. In addition, the unit can be reset manually. This precision electrometer features a tilt-stand for convenient positioning of the unit. Fast and Easy to Use: Battery operation and built-in detector virtually eliminate setup time. Just place RAD-CHECK PLUS or external ion chamber on x-ray table; collimate, shoot and read the result. Accurate: Precision ion chamber and digital display ensure accuracy plus easy readability. Accurate, lightweight, portable...this industry standard enables you to gain the critical edge in your QC program. 06-526 RAD-CHECK PLUS 06-526-2200 RAD-CHECK PLUS, SI Units SPECIFICATIONS: Ranges: 0.001 to 2 R, 0.01 to 20R/min Internal Chamber: 30 cc volume, energy response ±5% from 15-65 kev (30-150 kvp filtered). 20.5 cm 2 (5.1 cm diameter) effective measurement area. Center of Chamber 1.03 cm below top of chamber Standard Calibration: At 75 kvp with 4 mm Al filtration at 22 C and one atmosphere Reproducibility: Within 2% short-term over 100 mr to 2 R range (1 mgy to 20 mgy) Electrometer Drift: 0.5 to 1 mr/minute typical; 6 mr/minute max (5 µgy to 10 µgy; 60 µgy/minute max) Maximum Exposure Rate: Min. 90% collection efficiency at 20 R/second Automatic Reset: Resets display to zero. Can also be reset manually Operating Conditions: 10-40 C, max; 90% relative humidity Display: 3 1 /2'' x 1 /2'' LCD, low battery indicator Controls: Auto or manual reset selector. Display zero reset button. Dose or dose rate output selector. Integral or remote ion chamber selector. On/off switch Power: 9 V battery, Mallory MN1604 or equal, greater than 100 hour life (50 hours in manual reset mode) Dimensions: 2.75'' high x 6'' wide x 6.25'' deep (7 cm x 15.25 cm x 15.9 cm) Weight: 18 oz (0.51 kg)

ACCESSORIES: 06-528 Remote Ionization Chamber: 30 cc volume; energy response: within 7%from 30 to 150 kvp (15-65 kev); 15 foot (4.5 meter) cable; 4'' x 4'' x 0.54'' thick (10.2 cm x 10.2 cm x 1.4 cm) 06-529 Mammographic Ionization Chamber: 3.3 cc volume; energy response: within 5% from 0.2 to 5.0 mm Al HVL (16 to 90 kvp); 15 foot (4.5 meter); 4 cm diameter x 1.5 cm thick 30-301-1000 CT Dose Probe: 3.2 cc volume; energy response: ±5% from 1 to 10 mm Al HVL; 0.9 meter cable; sensitive length: 4 inches (10.0 cm); chamber inside diameter: 0.25 inches (6.4 mm) 06-524-1000 Fluoroscopic Exit Dose Ionization Chamber: 150 cc volume; energy response: +/-10% from 1.8 to 10 mm Al HVL; 10 foot (3.0 meter) cable; 6.26'' x 8'' x 0.63'' (15.9 cm x 20.6 cm x 1.6 cm) 89-525 Carrying/Storage Case: Holds RAD-CHECK PLUS and Accessories RADIOLOGY/ FLUOROSCOPY 16

RAD-CHECK MAMMO X-RAY EXPOSURE METER Proven RAD-CHECK performance designed specifically for use in mammography. Fast and easy to use! Measures dose: 0.001 to 20 mgy; 0.01 to 20 mgy/min. Extremely compact 6'' x 6 1 /4'' x 2 3 /4''; weighs only 18 oz. Specifically designed and calibrated for use with the model 06-529 Mammography Ionization Chamber. RAD-CHECK MAMMO can perform: Entrance Skin Exposure Measurements (ESE). Exposure checks; radiographic (mr/mas). Beam quality; Half Value Layer (HVL). mas reciprocity; ma Station Checks Plus many others, depending on the remote external chambers used. RAD-CHECK MAMMO is built on the same proven technology as the RAD-CHECK PLUS, but is optimized to provide accurate dose and dose rate readings in the mammography range. It s economi-cal, since you don t pay for features you can t use. Our mammography chamber (required for use with this electrometer), has been thoroughly tested and will match the performance of any other parallel-plate mammography chamber mammography chamber available. Accurate readings can also be made with a different volume ionization chamber using correction factors. Precise, reliable, proven technology that economically answers your specific needs and requirements. RAD-CHECK MAMMO will help elevate your QC program to new heights. SPECIFICATIONS: Ranges:.001 to 2 R;.001 to 2 R/min (.001 to 2 mgy;.001 to 2 mgy/min) Standard Calibration: At 23, 28, 30 and 35 kvp (Mo/Mo) at 22 C and one atmosphere using model 06-529 chamber (optional) Reproducibility: Within 2% short-term over 100 mr to 2 R range (1mGy to 20 mgy) Electrometer Drift: 10 mr/minute typical; 60 mr/minute max

(10 µgy; 60 µgy/minute max ) Maximum Exposure Rate: Min. 90% collection at 20 R/second Manual Reset: Resets display to zero Operating Conditions: 10-40 C, max; 90% relative humidity Display: 3 1 / 2 '' x 1 / 2 '' LCD, low battery indicator Controls: Reset button. Dose or dose rate output selector. On/off switch Power: 9V battery, Mallory MN1604 or equal, greater than 50 hour life Dimensions: 2.75'' high x 6'' wide x 6.25'' deep (7 cm x 15.25 cm x 15.9 cm) Weight: 18 oz (0.51 kg) 06-526-5290 RAD-CHECK MAMMO 06-526-5292 RAD-CHECK MAMMO, SI Units ACCESSORIES: 06-529 Mammographic Ionization Chamber: 3.3 cc volume; energy response: within 5% from 0.2 to 5.0 mm AI HVL (16 to 90 kvp); 15 foot (4.5 meter) cable; 4 cm diameter x 1.5 cm thick 89-525 Carrying/Storage Case: Holds RAD-CHECK MAMMO and Accessories IMPORTANT NOTE: MQSA requires exposure readings with the Mammography Accreditation Phantom the RAD-CHECK MAMMO is ideal! 06-529 Small and portable, it will accurately provide the mid-glandular dose readings required by MQSA. RAIOLOGY/ FLUOROSCOPY 17

RAD-CHECK MICRO-R X-RAY EXPOSURE METER Nuclear Associates RAD-CHECK MICRO-R technology gives you the ability to measure dose and rate in fluoroscopy with the accuracy and reliability of equipment that costs two or three times more. Fast and easy to use! Dual-range for high and low dose rate fluoroscopy. Optimized for use with Nuclear Associates 100 cc Image Intensifier Ion Chamber model (06-524-3000). Portable, no AC power cords. RAD-CHECK MICRO-R can perform: Entrance Skin Exposure Measurements (ESE). Fluoroscopy exposure examinations. Exposure checks; radiographic (mr/mas). Beam quality; Half Value Layer (HVL). mas reciprocity; ma Station Checks Plus many others, depending on the remote external chambers used. This state-of-the-art electrometer is designed for measuring dose and rate under high and low dose rate conditions. It is excellent for cardiac cath and fluoroscopy and the perfect choice for tight budgets. With the RAD-CHECK MICRO-R, measurements are easy to perform and highly accurate. Incorporate

RAD-CHECK MICRO-R into your routine QC program for fluoroscopy now, and accurately measure what your patient exposures actually are from fluoroscopically-guided procedures. This precision electrometer also features a tilt-stand for convenient adjustment of display visibility. SPECIFICATIONS: Ranges: Low: 0.01 to 19.99 mr; 0.1 to 199.9 R/min High: 0.01 to 19.99 R; 0.1 to 1999 R/min Standard Calibration: At 75 kvp with 4 mm Al filtration at 22 C and one atmosphere using model 06-524-3000 chamber (optional) Reproducibility: Within 2% short-term over 100 mr to 2 R range (1mGy to 20 mgy) Electrometer Drift: Low Range: 1 mr/minute typical; 6 mr/minute max High Range: 10 µr/min typical; 60 µr/min max Maximum Exposure Rate: Min. 90% collection at 20 R/second Manual Reset: Resets display to zero Operating Conditions: 10-40 C, max; 90% relative humidity Display: 3 1 / 2 '' x 1 / 2 '' LCD, low battery indicator Controls: Reset button. Dose or dose rate output selector. High or low range selector. On/off switch Power: 9 V battery, Mallory MN 1604 or equal, greater than 50 hour life Dimensions: 2.75'' high x 6'' wide x 6.25'' deep (7 cm x 15.25 cm x 15.9 cm) Weight: 18 oz (0.51 kg) 06-526-5240 RAD-CHECK MICRO-R 06-526-5242 RAD-CHECK MICRO-R, SI Units ACCESSORIES: 89-525 Carrying/Storage Case: Holds RAD-CHECK MICRO-R and Accessories

IMAGE INTENSIFIER ION CHAMBER Volume: 100 cc Optimized for use with our RAD-CHECK and MICRO-R. Can be used with virtually any other commercially available electrometer. Designed to measure diagnostic x-rays. When used with RAD-CHECK MICRO-R, it is possible to measure exposure rate as low as. 10 micro Roentgens per second. 06-524-3000 Image Intensifier Ion Chamber RADIOLOGY/ FLUOROSCOPY 18 IMAGE INTENSIFIER ION CHAMBER Designed to measure diagnostic x-rays. It s low attenuation permits virtually no interference with automatic brightness systems. Optimized for use with our RAD-CHECK MICRO-R Can be used with virtually any other commercially available electrometer.

This 100 cc low profile ion chamber is designed specifically for measuring exposure rate at the input phosphor of fluoroscopic image intensifier tubes. Its extremely thin envelope enclosure allows for the most accurate results possible! Its unique size and shape allow it to be inserted into the spot film tray of typical image intensifier systems. A 21'' long detachable handle allows for easy insertion and removal. When used with the RAD-CHECK MICRO-R, it is possible to measure exposure rates as low as 10 micro Roentgens per second. Chamber Energy Dependence KVCP NIST Technique Approx. HVL (mm Al) Coul/µR x10-14 Correction Factor 60 M60 1.68 3.32 0.95 75 M75 4.1 3.49 1.00 100 M100 5.1 3.72 1.06 150 M150 10.2 3.94 1.12 A SPECIFICATIONS: Volume: 100 cc Nominal Sensitivity: 30 nc/r @ M75 Rate: 10µR/s Exposure: 100µR in 10 seconds Max. Exposure Rate: Min. 90% collection at 20R/Sec Total Attenuation: 0.275 (mm Al) equivalent @ 30 KeV Operating Voltage: 200 to 300 volts DC Handle Length: 21'' (53.34 cm) Cable Length: 10' (3 m). Cable Termination, BNC/Banana

Window Thickness:.110'' (2.79 mm) Housing Material: Acrylic Housing Color: Clear Housing Dimensions: 5.5'' diameter (14.0 cm diameter) Surface Area: 100 cm 2, 4.5'' diameter Thickness: 0.720'' (18.3 mm) Weight: 30 oz (840 g) 06-524-3000 Image Intensifier Ion Chamber SHADOW-FREE, LARGE-VOLUME IMAGE INTENSIFIER IONIZATION CHAMBER This 150 cc ionization chamber is designed primarily for measuring exposure rate at the image intensifier input phosphor. It s extremely thin envelope enclo-sure allows for the most accurate results possible! Because of its unique size and shape, it can be inserted into the spot film tray. A 16 1 /2'' long thread-ed handle allows for easy insertion and removal. And its low attenuation means virtually no interference with automatic brightness systems. Ion Chamber is compatible with the RAD-CHECK MICRO-R and most commercially available electrometers. SPECIFICATIONS: Volume: 150 cc Energy Response: +/-10% from 1.8 to 10 mm Al HVL Dimensions: 6.26'' x 8'' x 0.63'' (15.9 cm x 20.6 cm x 1.6 cm) Weight: 1.10 lbs (.50 kg) 06-524-1000 Shadow-Free, Large Volume Image Intensifier Ionization Chamber, with 10-foot (3-meter) Cable RADIOLOGY/ FLUOROSCOPY 19

RAD-CHECK REMOTE X-RAY EXPOSURE METER Specifically designed for use with the external 30 cc remote ion chamber (Model 06-528). Dose: 0.001 to 2R; 0.01 to 20 R/min. Easy setup puts the display close to you when it s difficult to see into the room. RAD-CHECK REMOTE can perform: Entrance Skin Exposure Measurements (ESE). Fluoroscopy exposure measurements. Exposure checks; radiographic (mr/mas). Beam quality; Half Value Layer (HVL). mas reciprocity; ma Station Checks Plus many others, depending on the remote external chambers used. The RAD-CHECK REMOTE works specifically with an external remote chamber, so it s extremely versatile. It s the ideal quality control device for a variety of appli-cations and situations, since it gives you the opportuni-ty to place the chamber in any orientation! And it s per-fect for phantom testing, fluoroscopy or when using an external ion chamber. (External ion chambers other than 06-528 may be used, but require system recalibration.) The RAD-CHECK REMOTE is easy to set up and use. Its versatility makes it the perfect addition to your QC test equipment. In those cases where it s inconvenient to have the display in the x-ray room, or visibility is difficult, RAD-CHECK REMOTE puts the display next to you. Model 06-528 SPECIFICATIONS: Ranges: 0.001 to 2 R; 0.01 to 20 R/min Standard Calibration: At 75 kvp with 4 mm Al filtration at 22 C and one atmosphere using model 06-528 chamber (optional) Reproducibility: Within 2% short-term over 100 mr to 2 R range (1 mgy to 20 mgy)

Electrometer Drift: 0.5 to 1 mr/minute typical; 6 mr/minute max. (5 µgy to 10 µgy; 60 µgy/minute max) Maximum Exposure Rate: Min. 90% collection at 20 R/second Manual Reset: Resets display to zero Operating Conditions: 10-40 C, max; 90% relative humidity Display: 3 1 /2'' x 1 /2'' LCD, low battery indicator Controls: Reset button. Dose or dose rate output selector. On/off switch. Tilt stand to adjust display visibility Power: 9V battery, Mallory MN1604 or equal, greater than 50 hour life Dimensions: 2.75'' high x 6'' wide x 6.25'' deep (7 cm x 15.25 cm x 15.9 cm) Weight: 18 oz (0.51 kg) 06-526-5280 RAD-CHECK REMOTE 06-526-5282 RAD-CHECK REMOTE, SI Units ACCESSORIES: 06-528 Remote Ionization Chamber: 30 cc volume; energy response: within 7% from 15-65 kev (30-150 kvp filtered); 15 foot (4.5 meter) cable; 4'' x 4'' x 0.54'' thick (10.2 cm x 10.2 cm x 1.4 cm thick); 4 oz. (0.11 kg.) 89-525 Carrying/Storage Case: Holds RAD-CHECK REMOTE and Accessories A Elimpex-Medizintechnik, Spechtgasse 32, A-2340 Moedling, Austria phone +43-2236-410450 fax +43-2236-410459