CF016D CELL ASSEMBLY & OPERATION MANUAL

Similar documents
OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range

Geotech 1.66 Reclaimer

Models: C62/63/64-A/D

1020 Industrial Drive, Orlinda, TN fax

BS Series Basket Strainer

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

ACCU-MIX 1200 / / 26270

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

CSA Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

Geotech Portable Bladder Pumps Installation and Operation Manual

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

FloWash. Industrial Filter Cart

Multi-Probe Sampling System User Guide & Manual

Stainless Steel 142 mm Filter Holder YY

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

OPERATING MANUAL LO-CROSS-FLOW CF M

Pure Water Power Purification System 4-Stage RODI Operations Manual

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

TITAN FLOW CONTROL, INC.

MODEL CALIBRATION GAS DELIVERY SYSTEM

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems

Marschalk Model # 94000

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

Geotech 3.5 Reclaimer Installation and Operation Manual

Geotech 1.66 Reclaimer Installation and Operation Manual

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS

Techcon Systems TS1258 Pressure Pot

SC HYDRAULIC ENGINEERING CORPORATION

FLOW CONTROL & AIR PILOT SWITCH VALVES

OPERATION MANUAL NTF-15

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

Light Commercial Reverse Osmosis System. EE-1000 Manual

Vessel Installation and Operating Manual

Vibro -LE Manual. Please be sure to read this entire user manual prior to use of the equipment. Please read all safety instructions carefully.

Techcon Systems TS1254 Pressure Pot

VACUUM REGULATORS CONTENTS

Model ASSEMBLY and OPERATING INSTRUCTIONS

Sample Concentrator SBH CONC/1 Instructions for use

RK LEL Sample Draw Aspirator Adapter Operator s Manual

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Ocean Technology Systems ComBox

Installation and commissioning instructions 255 series and 256 series

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

INSTRUCTIONS PARTS LIST

Pressure Relief Valve Instruction Manual

600 o F High Temperature Aging Cell Instruction Manual

OPERATION MANUAL NTF-60 Plus

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Installation and Operating Manual

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

2 I All-Flo Pump Co.

Operating Instructions

Liquid Level Controllers

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

Installation Operation Maintenance

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Pressure Injection Cell Operator s Manual

2 I All-Flo Pump Co.

GRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Instructions-Parts List

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

ATEX ATEX

BGI, INC. WALTHAM, MA 02451

Instruction Manual Updated 7/26/2011 Ver. 2.2

Installation, Operation and Maintenance Manual

EQUIPMENT Operation Manual

Variable Area Flow Meters

Cocoa Patio Pond with Lit Spillway

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

PORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

The Univentor 1250 Anaesthesia Unit

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

High Temperature Aging Cell Instruction Manual. Manual No , Revision F

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

Concentration and diafiltration of viral antigens with SmartFlow TFF

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

INSTALLATION INSTRUCTION

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

FLANGED TWO-PIECE BALL VALVES

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

DRAFT Standard Operating Procedure Ultrafiltration and Reverse Osmosis

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Float Operated Level Controllers

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Transcription:

CF016D CELL ASSEMBLY & OPERATION MANUAL

CONTENTS 1. INTRODUCTION... 1 2. CF016D CELL COMPONENTS... 1 3. CF016D CELL ASSEMBLY...3 4. CF016D CELL CONNECTIONS AND PARTS...4 5. OPERATION OF THE CF016D CELL... 5 6. SUPPLEMENTARY OPERATING INFORMATION... 6 7. ACCESSORY AND SPARE PART ORDERING INFORMATION...7 8. RETURN MATERIAL AUTHORIZATION... 8 9. WARRANTY... 8 10. TECHNICAL ASSISTANCE... 8 APPENDIX 1: CF016D APPLICATIONS... 9 APPENDIX 2: BENCH SCALE FILTRATION PRODUCTS...10

1. INTRODUCTION The CF016D Cell is a laboratory-scale crossflow filtration unit that is designed to evaluate flat sheet membranes in a variety of applications. It simulates the flow dynamics of larger, commercially available membrane elements such as industrial spiral wound membrane elements. Users can vary the operating conditions and fluid dynamics over broad ranges. Table 1 outlines the operational parameters and technical specifications of the CF016D Cell. Prior to operating or servicing this device, this manual must be read and understood. Table 1: CF016D Features and Technical Specification Parameter Membrane Active Area CF016D Maximum Pressure Maximum Temperature O-rings ph Range Cross Flow Velocity Dimensions Slot Depth Slot Width Description 20.6 cm² (3.1 in²) Delrin 27.6 bar (400 psig) 82 C (180 F) Buna* (Other materials available) Membrane Dependent Variable 2.28 mm (0.09 inches) 40 mm (1.54 inches) 2. CF016D CELL COMPONENTS The cell body consists of the tightening knobs, cell top, sintered metal support, O-rings, and cell bottom. Figure 1 (see page 2) illustrates a typical assembly of the CF016D. The CF016D is also packaged with a length of permeate tubing and membrane cutting template. 2.1 ADDITIONAL EQUIPMENT The CF016D cell also requires additional equipment to operate that are sold separately: Feed Pump Feed Tank Filtration membrane packs 1 Sterlitech Corporation CF016D Cell Manual

Figure 1: CF016D Crossflow Cell Body Assembly 3 1 5 4 2 Legend: 1. Cell top 2. Cell bottom 3. Tightening knobs 4. O-rings 5. Sintered metal support CF016D Cell Manual Sterlitech Corporation 2

3. CF016D CELL ASSEMBLY After verifying that all of the necessary components were shipped and present, you can begin the assembly of the crossflow cell. To assemble the CF016D crossflow cell: 1. Wet the O-rings with a small amount of water or the fluid to be processed and install them into the grooves on the cell bottom. Caution: Make sure that the O-rings lie flat in the grooves of the cell bottom. Leaking may occur if the O-rings do not lie flat in the grooves. The O-rings will be cut or crushed when the system is operating if the O-rings are not installed correctly. 2. Place a piece of pre-cut membrane onto the cell bottom using the two alignment pins to hold the membrane in position. The membrane should be installed with the shiny or active side facing the feed solution. Note: If you are cutting your own membranes, the membrane s outer edge should fit between the inner and outer O-rings in the cell body to prevent leakage. 3. Place the cell top. 4. The alignment holes in the top should fit over the alignment pins in the cell bottom. 5. Insert one of the brass washers into each of the four holes at the corners of the cell top. 6. Secure the cell top by inserting and tightening one of the provided screws into each of the corner holes. The CF016D crossflow Cell is now assembled and ready to be connected to a feed pump for operation. 3 Sterlitech Corporation CF016D Cell Manual

4. CF016D CELL CONNECTIONS AND PARTS Figure 2: Example CF016D Flow Diagram TEMPERATURE CONTROL SOLUTION INLET 1 D 5 7 TEMPERATURE CONTROL SOLUTION OUTLET B 6 E 2 8 10 4 9 11 A 3 A C CF016D FLOW DIAGRAM ITEM NO. PART DESCRIPTION 1 CONICAL FEED TANK 2 PRESSURE RELIEF VALVE 3 FEED PUMP 4 DRAIN VALVE 5 FLOW METER 6 SCALE FOR MEASURING PERMEATE FLUX 7 PERMEATE COLLECTOR 8 BY-PASS NEEDLE VALVE WITH 3/8" "T" TUBE FITTING 9 CF016D CELL ASSEMBLY 10 CONCENTRATE/ CONTROL VALVE ASSEMBLY )0-1000 PSI) 11 FEED PRESSURE GAUGE A 3/8" HIGH PRESSURE FLEX OR RIGID TUBING, FEED LINE B 3/8" LOW PRESSURE TUBING, BY-PASS C 3/8" LOW PRESSURE TUBING, RETURN LINE D 1/4" LOW PRESSURE TUBING, PERMEATE OUTPUT LINE E 3/8" LOW PRESSURE TUBING CF016D Cell Manual Sterlitech Corporation 4

Figure 2 shows typical plumbing connections that need to be made for the operation of the CF016D Cell; the configuration can change slightly depending on the objectives of the user. In general, the connections to be made are: 1. Feed vessel to the inlet pump 2. Pump outlet to the feed inlet of the cell body 3. Concentrate outlet of the cell body to the feed vessel 4. Permeate outlet to the permeate collection vessel Figure 2 also lists the additional components that are necessary to operate the CF016D cell. These components are sold separately and can be found in the Membrane/Process Development section of the Sterlitech website (http://www.sterlitech.com/membraneprocess-development.html). The final assembly of the crossflow system will vary with the feed vessels, pumps, and tubing used. 5. OPERATION OF THE CF016D CELL Once the CF016D Cell has been assembled and connected to a feed system, it can be used in variety of applications that includes reverse osmosis, ultrafiltration, nanofiltration, and microfiltration. To operate the CF016D Cell: 1. Open all of the valves in the system to relieve any pressure build-up before turning on the feed pump. 2. Turn the feed pump on. 3. Set the feed pressure to be less than or equal to 400 psig by gradually closing the concentrate valve. Note: A good starting point may be to set the system at 1.7 bar (25 psig) pressure for ultrafiltration or 17.2 bar (250 psig) for reverse osmosis. If this does not produce the desired results then the parameters can easily be adjusted and different membranes can be used. 4. Verify the feed pressure reading on the concentrate pressure gauge sold separately. 5. Adjust the concentrate flow control valve to obtain the desired pressure and flow. Experimentation enables you to determine the optimum settings for pressure, flow rate, and shim/spacer combination to use on the chosen membrane and the fluid being processed. 6. Once the experiment is complete, shut down the system by turning the feed pump off and opening all of the valves to relieve any pressure build up. 5 Sterlitech Corporation CF016D Cell Manual

To replace a membrane filter: 1. Turn the feed flow pump OFF. 2. Open all of the valves in the system to relieve any pressure build up. 3. Loosen the screws in the cell top. 4. Separate the cell body top from the cell bottom. 5. Remove the membrane. 6. Install the new membrane. 7. Reassemble the cell top and bottom. 8. Secure the cell top to the cell bottom using the screws. 9. Turn the feed flow pump on. 6. SUPPLEMENTARY OPERATING INFORMATION 6.1 MEMBRANE PERFORMANCE RESULTS Spiral wound membranes containing mesh spacers are usually operated with a fluid velocity across the membrane surface of 0.1 0.5 m/sec (0.3 1.6 ft/sec). Higher velocities in membranes may lead to excessive pressure differential across the membrane and possible damage. Hollow fiber membranes, tubular membranes, and membranes with tubular spacers may be operated at higher velocities, but this may not contribute to a more effective operation. 6.2 MEMBRANE PERFORMANCE Other parameters such as viscosity, pressure, and suspended solids may also affect performance/operation. Experimentation with the CF016D Cell can help predict the best operating parameters. If your pump is delivering too much flow, a portion of the flow can be diverted back to the feed container before entering the feed inlet of the cell body. This requires installation of an optional bypass valve and fitting on the pump outlet (Figure 2, #8), which is not supplied with the system. 6.3 TEMPERATURE LIMITS The membranes, feed spacer, permeate, O-rings, and cell body materials construction dictate the maximum operating temperatures. Table 2: Upper Temperature Limits Component CF016A Cell Membrane Elements O-rings Maximum Temperature 82 C (180 F) Variable Viton 200 C (400 F) EPDM 150 C (300 F) Buna-N 121 C (250 F) CF016D Cell Manual Sterlitech Corporation 6

6.4 MEMBRANE CLEANING The CF016D Cell can be cleaned easily after the membrane is removed. However, you may wish to simulate the actual cleaning conditions of Cleaning-In-Place (CIP) in larger systems with spiral-wound or tubular membranes. This can be done with CIP. Clean-In- Place chemically cleans without removing the membrane to mechanically scrub the unit. During CIP, cleaning solutions are re-circulated and, in some cases, allowed to sit for a period of time within the cell body. In some cases, the feed pump can be used to recirculate the cleaning solutions. 7. ACCESSORY AND SPARE PART ORDERING INFORMATION Accessories and spare parts for the CF016D Crossflow Cell can be ordered by calling Sterlitech Corporation at 1-877-544-4420 or by visiting www.sterlitech.com. Table 3: Accessory and Spare Part Ordering Information Product Shipping Weight Ordering Number CF016D Cell, for operation to 69 bar (1000 psig) 4.5 kg (10 lbs) CF016D Feed Flow Pump Contact Sterlitech Contact Sterlitech Accessories Feed Spacer Assortment Pack 17, 31, 47, and 65 mil 0.5 kg (1 lb) 1142820 CF016 Stainless Steel Stand 3.1 kg (7 lbs) 1230031 Spare Parts Viton O-rings 28 g (1 oz) 1220138 Concentrate Control Valve Assembly 0.9 kg (2 lbs) 1200013 Membrane Packs Contact Sterlitech Contact Sterlitech 7 Sterlitech Corporation CF016D Cell Manual

8. RETURN MATERIAL AUTHORIZATION If materials are to be returned to Sterlitech for repair, evaluation, or warranty consideration, a Return Material Authorization (RMA) number and form must be obtained from Sterlitech prior to the return. Contact Sterlitech s Customer Service Department for these forms. The form must be completed and returned with the material. Be sure to include a complete, detailed written reason for the return. Also, include serial numbers, installation and removal dates, and any other pertinent information that is available. CF016D Cells have a serial number imprinted on the cell bottom. Indicate the proposed disposition of the material, and reference the RMA number on all packages or cartons. All material must be shipped to Sterlitech with freight prepared by the customer. 9. WARRANTY The following is made in lieu of all other warranties expressed or implied. Sterlitech Corporation guarantees equipment to be free from defects in material and workmanship when operated in accordance with written instructions for a period of one year from receipt. Parts not manufactured by Sterlitech are covered by their manufacturer s warranties, which are normally for one year. Manufacturers and Seller s only obligation shall be to issue credit against the purchase or replacement of equipment proved to be defective in material or workmanship. Neither manufacturer nor seller shall be liable for any injury, loss or damage, direct or indirect, special or consequential, arising out of the use of, misuse, or the inability to use such product. The information contained herein is based on technical data and tests, which we believe to be reliable, and is intended for use by persons having technical skill at their discretion and risk. Since conditions of use are outside Sterlitech s control, we can assume no liability whatsoever for results obtained or damages incurred through the application of the data presented. This information is not intended as a license to operate under, or a recommendation to infringe upon, any patent of Sterlitech or others covering any material or use. The foregoing may not be altered except by a written agreement signed by officers of the manufacturer. 10. TECHNICAL ASSISTANCE Please contact us if you have any questions or technical inquiries about our products by calling Sterlitech Corporation at 1-877-544-4420 or by visiting www.sterlitech.com. CF016D Cell Manual Sterlitech Corporation 8

APPENDIX 1: CF016D CELL APPLICATIONS The following studies utilized the CF042 Cell in their method and are listed here to illustrate the potential applications for the CF016. These studies are good references for understanding the operation of the CF016D Cell. APPLICATION Reverse Osmosis (Desalination) Forward Osmosis and Low Pressure Reverse Osmosis Ultrafiltration (Food Processing) Ultrafiltration and Nanofiltration (Protein Production) Membrane Development STUDY CITATION Sachit, Dawood Eisa. Analysis of reverse osmosis membrane performance during desalination of simulated brackish surface waters. Journal of Membrane Science. 453. (2014): 136-154. Yangali-Quintanilla, Victor, Zhenyu Li, et al. Indirect desalination of Red Sea water with forward osmosis and low pressure reverse osmosis for water reuse. Desalination. 280. (2011): 160-166. Post, Antonie, Hanna Sampels, et al. A comparison of micellar casein and β-casein as sources of basic peptides through tryptic hydrolysis and their enrichment using two-stage ultrafiltration. International Journal of Dairy Technology. 65.4 (2012): 482-489. Ranamukhaarachi, Sahan, Lena Meissner, et al. Production of antioxidant soy protein hydrolysates by sequential ultrafiltration and nanofiltration. Journal of Membrane Science. 429. (2013): 81-87. Qadir, Ahmad. Development of new membranes for desalination pre-treatment. MA thesis. University of Illinois at Urbana- Champaign, 2011. Web. <https://www.ideals.illinois.edu/ handle/2142/26369>. 9 Sterlitech Corporation CF016D Cell Manual

APPENDIX 2: STERLITECH BENCH SCALE FILTRATION PRODUCTS Discoverer Innovator Explorer Developer Investigator Filter Holder HP4750(X) CF016 CF042 Sepa 1812 Membrane Active Area Typical Permeate Flux Typical Permeate Flow Rate (per Cell) 14.6 cm 2 (2.26 in 2 ) 20.6 cm 2 (3.2 in 2 ) 42 cm 2 (6.5 in 2 ) 140 cm 2 (24 in 2 ) 0.27-0.46 m 2 (3-5 ft 2 ) 30-300 LMH (17.6-176 GFD) 30-300 LMH (17.6-176 GFD) 30-300 LMH (17.6-176 GFD) 30-300 LMH (17.6-176 GFD) 30-300 LMH (17.6-176 GFD) 1.5-15 ml/min 1-10 ml/min 2-20 ml/min 7-70 ml/min 350-2,300 ml/min System Capacity 0.7-7 L/day (0.2-2 GPD) 1.5-15 L/day (0.4-4 GPD) 3-30 L/day (0.5-5 GPD) 10-100 L/day (2.6-26 GPD) 194-1,940 L/day (51-510 GPD) Min. Batch Volume (per Cell) 300 ml 3.7 L (1 gal) 3.7 L (1 gal) 3.7 L (1 gal) 15 L (4 gal) Max. Pump Capacity N/A 6.8 LPM (76 bar) 1.8 GPM (1,100 psi) 6.8 LPM (76 bar) 1.8 GPM (1,100 psi) 6.8 LPM (76 bar) 1.8 GPM (1,100 psi) 6.8-38 LPM (76 bar) 1.8-10 GPM (1,100 psi) Cell Material SS316, Hastelloy PTFE, Delrin, Acrylic, SS316, Hastelloy PTFE, Delrin, Acrylic, SS316, Hastelloy Acrylic, SS316, Hastelloy SS316 Max. Operating Pressure HP4750: 69 bar (1,000 psi) HP4750X: 172 bar (2,500 psi) PTFE/Acrylic: 27.6 bar (400 psi) Delrin/SS316/Hastelloy: 69 bar (1,000 psi) PTFE/Acrylic: 27.6 bar (400 psi) Delrin/SS316/Hastelloy: 69 bar (1,000 psi) Acrylic: 27.6 bar (400 psi) SS316/Hastelloy: 69 bar (1,000 psi) 41.4 bar (600 psi) Filtration Mode(s) Dead-End Stirred Cell Cross Flow, Forward Osmosis Cross Flow, Forward Osmosis Cross Flow, Forward Osmosis Cross Flow CF016D Cell Manual Sterlitech Corporation 10

NOTES:

Founded in 2001 in Kent, WA, Sterlitech Corporation manufactures and markets filtrationfocused laboratory products to a broad spectrum of scientific and industrial sectors. Its line of flat sheet membranes and tangential flow cells deliver industry-leading performance and reliable results. Configured for reverse osmosis, nanofiltration, ultrafiltration, and microfiltration applications, Sterlitech s bench scale test equipment provides the versatility required to innovate. Sterlitech s comprehensive line of products is supported by the expertise of its technical specialists who can assist with application-specific product selection, and provide customized solutions where necessary. Unique problem-solving approaches, flexibility, and consistent quality have made Sterlitech Corporation a renowned global provider of filtration products and equipment. General Corporate Information Sterlitech Corporation 22027 70th Avenue S Kent, WA 98032-1911 USA Tel: 877-544-4420 or 1-253-437-0844 Fax: 1-253-437-0845 info@sterlitech.com Sales Inquiries sales@sterlitech.com Accounts Payable AP@sterlitech.com Accounts Receivable AR@sterlitech.com Press Inquiries PR@sterlitech.com

For more information, call (253) 437-0844, (877) 544-4420, or visit www.sterlitech.com 2018 Sterlitech Corporation 22027 70th Ave. S Kent, WA 98032-1911 USA Phone: (253) 437-0844 Fax: (253) 437-0845 Email: sales@sterlitech.com VERSION 1