Circuit breaker diagnostic testing. Megger is a registered trademark

Similar documents
The Path to LUBRICATION EXCELLENCE

Naval Postgraduate School, Operational Oceanography and Meteorology. Since inputs from UDAS are continuously used in projects at the Naval

Pulsed Eddy Current (PEC) Inspection through Insulation

Advanced Test Equipment Rentals ATEC (2832) OMS 600

Operations. On The Use of Safety Moorings in DP Operations

Technical Note. Determining the surface tension of liquids by measurements on pendant drops

EXPERT SYSTEMS IN ULTRASONIC FLOW METERS

CHAPTER 8: MECHANICAL WAVES TRANSMIT ENERGY IN A VARIETY OF WAYS

Review packet Physical Science Unit Waves - 1

Science&Motion. SAM BalanceLab. Sports. control the invisible. Most advanced pressure plate for coaching

Experimental investigation of the check valve behaviour when the flow is reversing

Crystal Breath. High Level Design. Nicholas Castro, Suong Do, Joe Duffy, Joe Lervi, John Mullaney

PUV Wave Directional Spectra How PUV Wave Analysis Works

Goodyear Safety Research Project 2008 Presentation by Competitive Measure at the FEI Eventing Safety Forum. Presented by Tim Deans and Martin Herbert

Module No. # 01 Lecture No. # 6.2 HAZOP (continued)

Roadway Conditions as Contributing Factors in Florida Traffic Crashes

AIRMOUNT VIBRATION ISOLATION

Conditions for occurrence of vortex shedding on a large cable stayed bridge. Full scale data from monitoring system

Section 1 Types of Waves. Distinguish between mechanical waves and electromagnetic waves.

Dick Bowdler Acoustic Consultant

Testing Distribution Switchgear for Partial Discharge

Power Transformer Maintenance. Maintenance Practices & Procedures for Substation Class Distribution Power Transformers

The OWEZ Meteorological Mast

Chapter 19: Vibrations And Waves

Accident Reconstruction

7 th International Conference on Wind Turbine Noise Rotterdam 2 nd to 5 th May 2017

Critical Gust Pressures on Tall Building Frames-Review of Codal Provisions

Power Unit 075. Maintain Substation Circuit Breakers

The Use of Ultrasonic Inspections at Elevated Temperature

Paper #: POWER

9.2 Waves at Media Boundaries

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Sound and Light Test

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

Users Group Conference 2018

The Criticality of Cooling

REPORT. A comparative study of the mechanical and biomechanical behaviour of natural turf and hybrid turf for the practise of sports

Simple Time-to-Failure Estimation Techniques for Reliability and Maintenance of Equipment

Atmospheric Waves James Cayer, Wesley Rondinelli, Kayla Schuster. Abstract

Pendant Drop Measurements

CA3120 Anti-fretting Epoxy Varnish. Excellent anti-fretting properties High lubrication rate Abrasion resistant Allows high friction coefficient

WAVES. Pulses are disturbances or a single wave motion. A continuous production of pulses will give rise to a progressive wave (wave train).

Lecture Outline Chapter 14. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

DANCE COMPETITION GENERAL RULES

Best Practice for Calibrating LTH Conductivity Instruments

Acoustical Modeling of Reciprocating Compressors With Stepless Valve Unloaders

DP Ice Model Test of Arctic Drillship

Selecting the right pressure sensor for your application

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

A PRACTICAL GUIDE TO YOUR TRAINING SESSIONS

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Analysis of the Article Entitled: Improved Cube Handling in Races: Insights with Isight

17.5 Behavior of Waves

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

STICTION: THE HIDDEN MENACE

23.1 Period and Frequency

Reliability of Safety-Critical Systems Chapter 10. Common-Cause Failures - part 1

Wire ropes condition monitoring: conception and embodiment

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

1. Compare production mass-produced striker-fired pistols in a scientific, repeatable, and transparent method.

MODELING&SIMULATION EXTRAPOLATED INTERNAL ARC TEST RESULTS: A COUPLED FLUID-STRUCTURAL TRANSIENT METHODOLOGY

Infrared Thermography Inspection Guidelines. Date Issued:

TECOTHERM NEO. Instructions for Use. MEDICAL EQUIPMENT for HYPOTHERMIA of NEONATES and INFANTS. Addendum 1 to

Aspects of gravimeter calibration by time domain comparison of gravity records

Wind tunnel acoustic testing of wind generated noise on building facade elements

Optimal Weather Routing Using Ensemble Weather Forecasts

GUIDELINES ON OPERATIONAL INFORMATION FOR MASTERS IN CASE OF FLOODING FOR PASSENGER SHIPS CONSTRUCTED BEFORE 1 JANUARY 2014 *

Moor, Tend Mooring And Unmoor Ship - Supervisor Level -

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

RELIABILITY ASSESSMENT, STATIC AND DYNAMIC RESPONSE OF TRANSMISSION LINE TOWER: A COMPARATIVE STUDY

Conventional Ship Testing

Equine Results Interpretation Guide For Cannon Angles May 2013

Surrounding buildings and wind pressure distribution on a high rise building

Hands on HALT and HASS

4.4 WAVE CHARACTERISTICS 4.5 WAVE PROPERTIES Student Notes

Availability analysis of railway track circuit

GasSense NDIR User Manual

Service Calibration are you doing it properly?

3. Real-time operation and review of complex circuits, allowing the weighing of alternative design actions.

Applications. What moves your world

Wave Motion. interference destructive interferecne constructive interference in phase. out of phase standing wave antinodes resonant frequencies

General Accreditation Guidance. User checks and maintenance of laboratory balances

Positioner type Smart Valve Positioner with diagnostic functions. Presented By: Mr. Gourishankar Saharan. Product management Jens Bargon / V42

Exercises Vibration of a Pendulum (page 491) 25.2 Wave Description (pages ) 25.3 Wave Motion (pages )

4: PROPERTIES OF WAVES Definition of Wave: A wave is a disturbance traveling in a medium.

Life Cycle Benefits: Maintenace (Control Valve Diagnostic and Field Device Diagnostic Management)

Physics 1520, Spring 2014 Quiz 1A, Form: A

Physics 1520, Spring 2014 Quiz 1B, Form: A

GEA FOR ADVANCED STRUCTURAL DYNAMIC ANALYSIS

Analysis of the Radar Doppler Signature of a Moving Human

AN31E Application Note

M. Mikkonen.

E2.14 Control of Hazardous Energy. Effective Date: 03/01/2018

Monitoring transformers with infrared cameras

A differerential pressure anemometer

Every things under control High-Integrity Pressure Protection System (HIPPS)

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Aquavar SOLO 2 Frequently Asked Questions

Technology: WebCAM at 30 fps / VGA resolution. Sensor with 4 LED emitter sensors. Software with picture analysis.

Transcription:

WWW.MEGGER.COM Megger is a registered trademark

Title Author Nils Wäcklén Date January 2010 Keywords TM1600, TM1800, CIGRÉ, vibration analysis, dynamic resistance measurement, circuit breaker testing, induction Abstract The paper provides a simple explanation of vibration testing and the type of diagnostic information it can produce. Care must be taken in setting up and carrying out the tests if accurate and dependable results are to be obtained. Users should also be aware of electrical interference such as induction, which is always present in electrical substations. Email Niclas.Wetterstrand@megger.com 2

The objective of all circuit breaker diagnostic testing is to detect defects before they cause damage and system outages. Many test techniques are used to achieve this, but one that receives less attention than it deserves is vibration testing. A recent CIGRÉ study on circuit breakers in active use revealed that 70% of malfunctions were caused by mechanical rather than electrical faults. What better basis could there be for diagnostic tests, therefore, than looking directly at the mechanical behaviour of the breaker? And this is exactly what vibration testing and more accurately an acoustic signature does. The test method employed is easy to under-stand. Accelerometers, which behave in much the same way as microphones, are attached to the circuit breaker under test. As the breaker opens and closes, the vibrations they pick up are recorded in much the same way as an MP3 file might be captured for a voice or music recording. The recordings can subsequently be replayed and analysed at will. The results are easiest to interpret if a reference recording often referred to as a reference signature or footprint is available. This is simply a recording made when the breaker was known to be in good condition and operating correctly. The reference signature can be readily compared with subsequent recordings, with any significant changes indicating potential problems. If no reference signature is available for the specific breaker under test, the comparisons can instead be made with the reference signature of another breaker of the same type. This is however a compromise, not least because it is very different to be certain that the parameters for tests on two individual breakers such as the exact placement of the accelerometers are identical. While it is possible for experienced users of vibration analysis to display the recordings on a computer screen and compare them by eye, dedicated software will always provide more detailed and more reliable results. The analysis looks in particular at two aspects of the comparison, which are usually referred to as time shift and deviation (magnitude). Particular vibration patterns are associated with specific mechanical events, such as the closing of the breaker s arcing contacts or main contacts. The time shift analysis looks for differences in the timing of these vibration patterns between the reference signature and the test recording. Deviation analysis looks for differences in the amplitude and frequency spectrum of the events. 3

While experience is undoubtedly the best guide to the interpretation of the results, it is possible to provide some rules of thumb. While these illustrate the usefulness of vibration testing however, it must be understood that they are neither absolute nor universal criteria and they must not be used without careful consideration of the specific application. According to these rules of thumb, if the time shift is less than 4 ms, and the deviation curves never diverge by more than 10 db, it is reasonable to assume that the circuit breaker is in the same mechanical condition as it was when the reference signature was generated. Note that successive tests on the same breaker will typically show differences of between 5 to 7 db, and this should be regarded as normal. In cases where the time shift is greater than 4 ms but less than 8 ms, but the deviation curves still never diverge by more than 10 db, this is likely to mean that the breaker is in the same mechanical condition, but that it is operating more slowly. This may be due to inadequate lubrication but, if the test is the first operation of the breaker for some considerable time, it is worth repeating it. If the second test gives normal results, it is very probable that the slow operation was caused by poor lubrication and/or corrosion friction. Note that a difference in ambient temperature can also produce a time shift as, in general, the colder the mechanism the slower the operating speed. This is particularly noticeable with hydraulic operating mechanisms. Finally, in cases where the deviation curves diverge by more than 10 db or the time shift is greater than 8 ms, this is a strong indication that the breaker is no longer in the same mechanical condition, and that there is a severe risk of it malfunctioning if it is put back into service. At this point, the vibration data can be further analysed to provide a guide to which part of the breaker s mechanical system is behaving differently. This is a good starting point for further diagnostic and remedial work. This article has, until now, concentrated on offering a simple explanation of vibration testing and the type of diagnostic information it can produce. Care must be taken in setting up and carrying out the tests if accurate and dependable results are to be obtained. In particular, the positioning of the accelerometers that pick up vibrations from the breaker is critical - changes in position of just a centimetre or two can make a big difference to the results. This also means that the positions used for the reference test must be clearly and indelibly marked, so that the accelerometers can be mounted in exactly the same positions for subsequent tests. 4

Another issue that often needs to be addressed is that of electrical interference such as induction, which is always present in electrical substations. The best instruments, such as the TM1600 and TM1800 from Megger, are well protected against interference but, nevertheless, it is still important to inspect the recordings for evidence of its influence. Fortunately, this is in most cases straightforward, as genuine vibration signals are always symmetrical around the zero line, whereas interference signals are not. Other factors that affect the quality of the results obtained from vibration testing include the method of attachment of the accelerometers to the circuit breaker, the level of signal pre-amplification used, and the time window used for the result comparisons. Manufacturers of test sets that support vibration analysis can be expected, however, to provide practical and reliable advice in all these areas. Nothing in this article should be interpreted as meaning that vibration analysis is the only type of testing needed for circuit breakers it should always be used in conjunction with more conventional motion, timing, DRM (Dynamic Resistance Measurement), and coil current tests to give an overall picture of breaker operation and condition. Vibration analysis is, however, a very useful weapon in the circuit breaker testing armoury it is convenient to apply and it can often uncover incipient problems that other test techniques would miss until they had become far more serious. 5

TM1800-1_WP_en_V01.pdf