TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Similar documents
Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.

Electronic Turbine Meter TERZ 94

RMG Meßtechnik GmbH. Publication No E

IGTM Gas Turbine Meter. with electronic outputs and mechanical counter. Documentation and Technical Specifications

IGTM Gas Turbine Meter. Documentation and Technical Specifications. Gas - Measurement. with electronic outputs and mechanical counter

Manual HA/CPT E

Turbine Meters TRZ 03 and TRZ 03-K

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

The number of revolutions is proportional to the passed volume. The rotation is transferred to a mechanical index, which indicates this volume.

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Ultrasonic Flowmeter USZ 08

Rotor Gas Meter. Creators in flow

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Gas Pressure Regulator HON 200

Monitoring device NTS 30

GA24 Technical Datasheet

GAS TURBINE METER IGTM-CT AND IGTM-IM

Integral type Differential pressure flowmeter VNT Series

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

Rotary Displacement Meter DKZ 04

GAS TURBINE METER IGTM-CT AND IGTM-WT

Torque Tube TB300 Digital Transmitters

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Product information. Ultrasonic Gas Meter. Custody Transfer Measurement in Natural Gas Distribution

Mass Flow Meter (MFM) for Gases

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Liquid ring compressor

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Gas Pressure Regulator R 51

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Air Eliminators and Combination Air Eliminators Strainers

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

I Connected Industrial. HON 5020 GAS PRESSURE REGULATOR Enabling Dependable Gas Operations

CGT-02 TURBINE GAS METERS

C-Flow Coriolis Mass Flow Meters

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

WATER METERS.

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

A E R Z E N E R M A S C H I N E N F A B R I K G M B H Z EN

Gas Filters DN15 DN300. elektrogas.com EE151 06/13

Slam Shut Valves SCN

safety Shut-Off Valve HON 721

Pro-V Multivariable Flowmeter

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Liquid ring compressors

6301 TYPE CAST IRON SAFETY VALVES

HON 219 Pressure Reducer (D119a)

SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Online data sheet FLOWSIC500 GAS FLOW METERS

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

INTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Safety Relief Valve HON 832

Mass Flow Controller (MFC) for Gases

I Connected Industrial. HON 5020 Gas Pressure. Enabling Dependable Gas Operations

Gas Pressure Regulator HON 300

pren CEN standard-draft pr EN 12261

HON HSV086 Series Safety Shut-off Valves for Efficient, Sustainable and Safe Gas Distribution. Proven Technology. Superior Performance.

Orifice Plate Flow Meter

Safety shut-off valve S 100. Product information

TME400-VC (..-VCF) turbine meter

TF- & DM-Series. Turbineflowmeter

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

deltaflowc deltaflowc Venturi or Probe

Gas Pressure Regulator HON 502

Engineering Data Sheet

Micro Motion 7812 Fiscal Gas Density Meter

Old documentation - Only for your information! Product is not available anymore!

Ratio Regulator Zero Governor. FRG/6 Series

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Level transmitter LT 100

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Flow metering in gases Introduction to COMBIMASS family

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

Pressure transmitters EMP 2

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

Safety Relief Valve HON 835

SIHI LPH-X - Liquid Ring Compressors

Variable area flowmeter F VA 250

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

EC type-examination certificate UK/0126/0065 Revision 1

CAST IRON SAFETY VALVE TYPE 6301

Fuel Filters DN15 DN25. elektrogas.com DE

Liquid level instruments BM 24 /BM 51

Pressure reducing valves Index

Safety Shut-Off Valve HON 720

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

United Kingdom of Great Britain and Northern Ireland

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Gas Pressure Regulator HON 505

Transcription:

TRZ 0-K Volumeter TRZ 0-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Turbine Gas Flowmeter continues the tradition of Honeywell s field-proven turbine meter technology, delivering the highest levels of accuracy and reliability. The TRZ 0-K is for secondary gas metering and is suitable for measuting the volume of natural, non-aggressive and manufactured gases ideally for check/allocation metering. Proven Technology. Superior Performance.

Method of Operation The TRZ 0-K Volumeter is a flow meter suitable for metering gases, where the rate of flow is indicated by a mechanical totalizer in units of volume (cubic meters at flowing conditions) under prevailing pressure and temperature. Digital index High-frequency Magnetic coupling Flow straightener Turbine wheel HF HF Oil pump The gas flow is constricted to a definite cross-section and drives a coaxially mounted turbine wheel. The speed of the turbine wheel, which is proportional to the flow rate, is reduced by gearing and transmitted to the mechanical digital index. Construction The meter case comprises the measuring element with the turbine wheel. A flow straightener located upstream of the measuring element substantially eliminates turbulences and swirl from the gas flow and directs the gas onto the turbine blades. The rotary motion generated by the turbine wheel is transmitted by LF HF Low-frequency Meter head type F Reference wheel High-frequency The number of rotations is reduced by gearing in the meter head, which can be adjusted by selecting an appropriate pair of adjusting gears, so that cubic meters at flowing conditions are indicated by the mechanical totalizer. A reed contact (or an inductive sensor) located on the mechanical totalizer provides low-frequency pulses whose number is proportional to the volume at actual conditions flowed through. In the case of larger nominal sizes and a higher pressure rating, the TRZ 0-K can be fitted with inductive high-frequency sensors scanning the turbine wheel (HF ) and the reference wheel (HF ). The reference wheel is a cam wheel located on the same shaft as the turbine wheel which enables the turbine wheel to be monitored. Features LF Pulse Transmitter (in the Meter Head) Standard: reed contact Alternatively: inductive Option: up to LF s possible. HF Pulse Transmitter (Option) In the meter head: inductive (HF ), pulse frequency at Q max approx. 0 Hz In the meter case: inductive for scanning the blades of the turbine wheel (HF, from DN 80) the cams of the reference wheel (HF, from DN 0). All inductive s provide volume pulses in compliance with NAMUR. Meter Head (Type F ) Protection class IP 65 Universally readable Totalizer unit and HF are easily replaceable on site. Measuring Range: Up to :6 Nominal Size: DN 50 Through DN 600 Special designs with larger nominal sizes up to DN 00 are possible. Pressure Rating: PN Through PN 0, Through ANSI 600 Special designs with a higher pressure rating are possible. Operating Temperature Range Standard design: - C to +50 C Special designs for higher and/or lower temperatures are possible. Explosion Protection The s are intrinsically safe; their type of protection is EEx ib IIC T6. Therefore, the TRZ 0-K can be operated in Zone. Long Service Life p r -Connection To connect the pressure transmitter of a PTZ corrector. Manufacturer s Test Certificate In compliance with EN 0/., for strength and leak testing. Materials Rotor Delrin for DN 50 to DN 00 and PN / PN 6. Aluminium alloy for all other diameters and pressure ratings and for meters with HF sensors. Aluminium rotors instead of delrin rotors on special request. Meter Case Material (Standard)* PN ANSI DN 6 0 6 0 50 00 600 50 80 0 50 00 00 500 600 Steel Cast Steel Spheroidal Cast Iron Steel, Welded *any material available on special request a magnetic coupling from the pressurized meter case to the unpressurized meter head.

Perforated-plate Straightener LP-5 Perforated-plate Straightener Accuracy Error limits (standard) ±% for Q min to 0. Q max (DN 50, DN 80: ±%) ±% for 0. Q max to Q max (DN 50: ±.5%). These limits apply in the event of a steady, swirl-free flow. Higher accuracy available on special request. Repeatability: ±0.% All gas meters are tested in the factory with air under atmospheric pressure. Approvals The gas meters substantially comply with PTB and EC/EEC regulations (G0 B of the EC dated September 6, 97). The TRZ 0-K Volumeter has been examined according to the pressure equipment directive 97//EC by DVGW and is registered under the product ident number CE-0085BN09. The TRZ 0-K Volumeter meets the OIML guideline IR-/89, Annex A. Pressure Loss The pressure loss sp stated in the table applies to natural gas at Q max and bar. From this, the pressure loss at actual conditions can be calculated using the following formula: sp A = sp p N Q max) 0.8 p A ( Q A sp A = Pressure loss at actual conditions (p A, Q A) in mbar sp = Pressure loss at Q max with natural gas at bar in mbar (see table) p N = Standard density of the gas in kg/m pa = Operating pressure in bar (absolute) Q A = Flow rate at actual conditions in m /h Q max = Maximum flow rate in m /h (see table) Example: Air, p N =.9 kg/m, nominal meter size DN 0, Q max = m /h, p A=. bar(a), Q A= m /h. Take from the table: sp = mbar. Hence: sp A =.9 0.8. ( ) mbar =.7 mbar Nominal Size DN Max. Flow Rate Q max V LF * p HF Pulse Transmitter (option) mm in. m /h m mbar HF HF 50 6-0 0. 5 80 0 50 6 00 8 00 6 500 0 600-60 6- - - 0-0- 65-00 0-600 0-600 60-0 60-0 -0-0 -0-0 -000-000 00-6000 00-6000 600-00 0 9 6 6 *VLF: Volume at actual conditions per LF pulse = not available = not available for all pressure classes = available for all pressure classes 8 7 8 Types of Gas The TRZ 0-K standard design is suitable for use with all gases in compliance with the DVGW code of practice G60. The materials used are appropriate for gases and fuel gases, such as natural gas, refinery gas, gaseous liquids and their mixtures, nitrogen, CO (dry), air and all inert gases. For aggressive gases (e.g. biogas, acid gas or ethylene), there are special designs available with PTFE lining, special material, special lubrication, etc. Mounting and Operating Instruction The TRZ 0-K Volumeters can be operated in horizontal or vertical position up to the nominal size of DN 50. For DN 00 the mounting position must be specified in the order. From the nominal size of DN, they can only be installed in a horizontal position. Special Instructions for Startup and Operation: Turbine meters are precise measuring instruments and must therefore be carefully handled during transport, storage and operation. Do not fill any downstream pipelines or station sections via the Volumeter. This may result in excessive flow rates with resultant damage to the turbine wheel. The gas meter has been designed for short-term overload operation at up to. times the value of Q max. Such load conditions should be avoided, however, in order to protect the TRZ 0-K from any unnecessarily high flow rates. The gas flow must be free of shocks or pulsations, foreign particles, dust or liquids. Otherwise it is recommended that filters and separators be installed. No components affecting the gas flow are permitted directly upstream of the Volumeter (see DVGW guidelines and PTB guideline G ). In each case, a DN inlet pipe and a DN outlet pipe are required, while also a bend may be used as outlet pipe. If flow perturbation (e.g. due to a gas pressure controller) occurs upstream of the inlet pipe, it is additionally necessary to use a perforated-plate straightener. There are perforated-plate straighteners available complying with ISO 567- or of the type RMG LP-5, the latter resulting in a pressure loss which is.5 times lower than that of the standardized flow straightener. Reducers or expansion fittings must be installed upstream of the inlet pipe, and their opening angle must not exceed 0. The gas meter must be installed in weather-proof locations. For outside installations, appropriate guards must be provided against direct weathering influences.

Pulse Outputs The meter head is fitted with a reed contact as LF as standard feature. But optionally, another two sensors can be fitted, e.g. another LF (inductive sensor with output pulses complying with NAMUR or reed contact) and an HF pulse transmitter (NAMUR). Connection is made by means of a 7-pin Binder plug: Nominal Size Measuring Range Dimensions Pressure Rating mm/inches Q min Q max L H 50/" 6 0 80/" 0/" 6 0 60 PN, 6,, 0, 00 PN, 6,, 0 PN, 6,, 0 Weight Approx. kg 50 0 50 5 Case Design Flanged 50/6" 0 65 0 00 600 PN, 6,, 0 75 85 0, : LF (reed contact), 5: LF or HF -signal, 6: HF (NAMUR) TRZ 0-K Volumeter 00/8" /" 0 60 60 600 0 0 0 PN, 6,, 0 PN, 6,, 00 05 60 00 00 70 If only one LF is fitted, it is always connected to the contacts and ; a single HF is always connected to the contacts and 6. If high-frequency s (with output pulses complying with NAMUR) are fitted which scan either the turbine wheel (HF ) or the reference wheel (HF ), each of them is connected separately using a Binder plug at the front of the device: Maintenance All turbine meters are fitted with a lubricator (DN 50 through DN 50: permanent lubrication, from PN /ANSI 00 pushbutton pump; DN 00: pushbutton pump; from DN : lever pump). Lubrication must be performed in compliance with the operating instructions (see also the lubrication instruction plate of the gas meter). If clean gas is used, lubrication is to be performed at -month intervals, whereas lubrication must be performed more frequently if dust- and/or condensate-laden gas is used. 00/" /6" 500/0" 00 0 0 0 000 000 6000 PN, 6,, PN 0, 6, 0, PN, 6,, PN 0, 6, 0, PN, 6,, PN 0, 6, 0, 00 65 0 50 5 00 600 90 80 600 50 750 5 500 750 55, : HF or HF -signal Order information Nominal size of the pipeline Volumetric flow rate in Nm /h or m /h (min/max) Operating pressure (min/max) in bar g or bar a 600/" 00 600 6000 00 PN, 6,, PN 0, 6, 0, 900 65 900 580 850 The contacts and are not assigned. All s are intrinsically safe and may be connected only to certified intrinsically safe circuits for use in areas subject to explosion hazards. Maximum frequencies: LF: 0. Hz HF : 00 Hz HF :. khz HF :. khz The phase displacement between the signals from the HF and HF s is 80. Operating temperature (min/max) Ambient temperature (min/max) Type of gas to be used Pressure rating and DIN or ANSI flange design Direction of flow / mounting position Accessories: inlet pipe, volume corrector, etc. Options: HF pulse outputs, etc. Special designs, e.g. for aggressive gases. 50/" 6 0 80/" 0/" 50/6" 00/8" 6 0 0 65 0 0 60 60 00 600 600 0 PN 6, 0 ANSI 600 PN 6, 0 PN 6, 0 PN 6, 0 PN 6, 0 80 5 0 5 50 5 50 75 85 0 00 05 0 Single-flanged /" 60 0 0 PN 0, 6, 0 00 00 DN 700 to DN 00 on request

Technical data is subject to change without notice. For More Information To learn more about Honeywell s Turbine Gas Flowmeter, visit www.honeywellprocess.com or contact your Honeywell account manager. Honeywell Process Solutions Honeywell West Sam Houston Parkway South Houston, TX 770 80 Kemper Meadow Drive Cincinnati, OH 50 Phone: + (5) 7- www.honeywellprocess.com BR-5--ENG August 05 05 Honeywell International Inc.