Tower Safety, Coax & RF Fittings, Network Analyzers

Similar documents
Centennial Fall Protection Work Plan _CP_11_20_en_A1

Fall Protection Introduction

User Instructions 1789 Parapet Wall Anchor

Telecommunication Tower Technician Course Descriptions

At the end of this presentation you should know the difference between fall prevention, fall restraint, and fall arrest.

Fall Protection Checklist. Guardrail System

OPE Training Seminar Agenda

Figure 1 - Parts Identification. Copyright 2002, DB Industries, Inc.

INSTRUCTIONS FOR USE

FALL PROTECTION PLAN FALL PROTECTION PROGRAM

Fall Protection ABC s

IMPORTANT: Record the product identification information from the ID label in the inspection and maintenance log in section 9.0 of this manual.

New Mexico Institute of Mining & Technology. Fall Protection Program

Fall Protection. 29 CFR Appendix C 29 CFR 1926 Subpart M

Fall Protection. Fall Prevention. vs. Sam Carbis Solutions Group. Solutions for Workplace Safety

Security and confidence at height.

Reliance Industries, LLC Operating instructions for the / Bolt-on D-Ring Anchorage. Model # 3071

INSTRUCTIONS FOR USE

FALL PROTECTION SAFETY PROGRAM

INSTRUCTIONS FOR USE

Fall Protection Refresher Orientation. Fall Protection Refresher Orientation 1

FALL PROTECTION (SAF-SPI-06)

User Instructions 1790 Rail Anchor

Figure 1 - Parts Identification

Instructions for the following series products:

User Instruction Manual Fixed Beam Anchor

User Manual 1792 Standing Seam Metal Roof Retractable Swivel Anchor

Occupational Protective Equipment

1.2 LIMITATIONS: Consider the following application limitations before using this equipment:

PTP 800 SPLIT-MOUNT SOLUTION

ARKANSAS TECH UNIVERSITY FACILITIES MANAGMENT HEALTH AND SAFETY MANUAL

Figure 1 - Cable Grip Horizontal Lifeline Termination ZORBIT ENERGY ABSORBER RELEASE TAB

"FALL PROTECTION IN CONSTRUCTION ENVIRONMENTS"

1 of 15. Policy Number 61. Last Update: March 21, Effective Date: 11/22/11 Resolution No Title: Fall Protection Policy POLICY STATEMENT

FALL PROTECTION / ELEVATED WORK

DREW UNIVERSITY FALL PROTECTION PROCEDURE (DRAFT 12/11)

What is fall protection?

Fall Protection STANDARD PROCEDURE INSTRUCTION. Fall Protection. Title SPI. Department. Supersedes SPI Dated. Jan 19, 2016.

September 23, 2016 Site Safe, Inc.

SECURITY AND CONFIDENCE AT HEIGHT

Are You OSHA Compliant? Browse Our Products Specifically For Compliance With The Updated Walking-Working Surfaces and Fall Protection Standard.

Fall Protection / Open Holes & Guardrail

Amphenol RF. Type N. Type N Connectors. Type N. Description. Features/Benefits. Applications

Fall Protection. ANSI-What is it, Why is it important? Craig Firl. March 5 th, Company Private

GM-121: Container End Lock Anchor Wand Page 1 WINSAFE CORP. GM 121 CONTAINER END LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

APPENDIX A. Appendix A: Fall Hazards Lesson Test Instructor Copy (answers bold/italic), Student copy to distribute follows

User Instruction Manual Fixed Beam Anchor

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

Progressive Safety Services LLC

??????? is committed to providing a safe work environment for its employees and preventing occupational injuries due to falls.

WBØTGE Mighty Woof 2m/440 Dual Band Fan Dipole (DBFD)

11.4 FALL-ARREST SYSTEM AND EQUIPMENT CHECKLIST (Must answer yes to all applicable questions)

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

REGULATIONS & COMPLIANCE. Riggers Safety LLC. 267 Winfield Cr. Corona, CA

Fall Protection PPT-SM-FALLPROT V.A.0.0

Section 16B. Fall Protection. Falls are the second leading cause of death in the workplace. Factors contributing to falling incidents:

SAFETY GUIDELINES. Table of Contents

Operating instructions. Skyline Beam Clamp

MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE

USER S INSTRUCTION MANUAL FOR THE INSTALLATION, OPERATION & MAINTENANCE OF THE GUARDIAN TEMPORARY HORIZONTAL LIFELINE SYSTEM

FALL PROTECTION GUIDELINE

Overview. Identify fall hazardous areas Describing potential fall hazards How appropriate portable and extension ladders are used

You may order this publication from WCB Publications and Videos, Please quote ordering number BK60.

1.0 Scope and Application

RollGliss Rescue Emergency Descent Device. This manual is intended to be used as part of an employee training program as required by OSHA.

December 2012 Safety Meeting. Fall Protection Answer Key 1. B 2. B 3. D 4. B 5. D 6. C 7. A 8. C 9. D 10. A KEY-SM-FALLPROT V.A.0.

[Sample] Corporation. Fleet Management Fall Prevention Program

The purpose of this training is to give field technicians awareness training and guidelines on potential hazards they may encounter in the field.

IMPORTANT: If you have questions on the use, care, or suitability of this equipment for your application, contact DBI/SALA.

Miller Falcon Edge Self-Retracting Lifeline When the Job Takes You to the Edge: Depend on Miller

Required Personal Protective Equipment (PPE) Checklist

User Instruction Manual. Fixed Beam Anchor

Fall Protection PPE Inspection

STORES FALL PROTECTION EQUIPMENT INVENTORY

LIGHTHOUSE SAFETY TRAINING 2018

THE MILLERGUIDE TO FALL PROTECTION PROGRAMS

FALL PROTECTION PLAN

OWNER'S MANUAL. Turnbuckle. Stanchions. Warning

Fall Protection. Fall Speed vs. Reaction Time. Good body reaction time = 0.5 seconds Travel distance in 0.5 seconds = 4 feet (1.21mts.

Fall Speed vs. Reaction Time

Fall Protection Policy

New ANSI Fall Protection Standards

COPYRIGHT 2014 ALCATEL-LUCENT. ALL RIGHTS RESERVED.

USER INSTRUCTIONS. Complies with ANSI Z359.1, ANSI Z359.4 standards and OSHA 29 CFR 1910 and 1926 regulations.

ABCD s of Fall Protection. Tom Shevlin Regional Sales Manager FallTech, Inc.

Competent Person - Fall Protection Presented by Turner Safety- your instructor is Steve Turner

ANSI Z359-Compliant Products from MSA

Operating instructions. Bolt-on Bar Joist Anchorage

IMPORTANT: If you have questions on the use, care, application, or suitability of this equipment contact DBI/SALA.

FALL PROTECTION. Leader s Guide. Marcom Group Ltd.

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

GM-120: Container Top Lock Anchor Wand Page 1 WINSAFE CORP. GM 120 CONTAINER TOP LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

Made in the USA. For Fall Protection Only. SafeLok Part Description

Tower Accessories & Hardware

Department of Facilities Management. Occupational Health and Safety. Fall Protection Program

Region: USA Language: EN Number : TB0031 Revision : B. Total Page: 3 Page n : 1 First Issue: 10/2014 Rev. Date: 10/08/2014

Overview (key points)

Fall Protection. Fall Protection

Patrick Harel Ph

To remind workers that falling from heights can result in serious injury. Enter your name and the training date on the Training Sign-In Sheet.

Transcription:

SFDX Association Talk November 2 nd 2011 Tower Safety, Coax & RF Fittings, Network Analyzers Mark Lavallee

Tower Safety & Working at Height 1. The most valuable asset. 2. Tower climbing, 100% tie off. 3. Positioning belt or full body harness for fall arrest. 4. Ground crew considerations, drop zone & under the load? 5. Tools and hardware equal missiles that can kill. 6. Tower rescues, its important to know. 7. Some thoughts that run through a persons/my head at height. Some are healthy some are counter productive. 8. Fear vs. Reason, respecting height, understanding the danger.

FROM OSHA PUBLICATION All fall protection products fit into four functional categories. 1. Fall Arrest; 2. Positioning; 3. Suspension; 4. Retrieval. Fall Arrest A fall arrest system is required if any risk exists that a worker may fall from an elevated position, as a general rule, the fall arrest system should be used anytime a working height of six feet or more is reached. Working height is the distance from the walking/working surface to a grade or lower level. A fall arrest system will only come into service should a fall occur. A full-body harness with a shock-absorbing lanyard or a retractable lifeline is the only product recommended. A fullbody harness distributes the forces throughout the body, and the shock-absorbing lanyard decreases the total fall arresting forces. Positioning This system holds the worker in place while keeping his/her hands free to work. Whenever the worker leans back, the system is activated. However, the personal positioning system is not specifically designed for fall arrest purposes. Suspension This equipment lowers and supports the worker while allowing a hands-free work environment, and is widely used in window washing and painting industries. This suspension system components are not designed to arrest a free fall, a backup fall arrest system should be used in conjunction with the suspension system. Retrieval Preplanning for retrieval in the event of a fall should be taken into consideration when developing a proactive fall management program.

How to select coaxial transmission line and RF Fittings 1. Teaser- Can you use RG-58 @ 1.5 kilowatt and TX continuous RTTY on HF? Can you use RG-174 coax at 610kHz @ 1000 Watts power? 2. Link Budget; how it relates to your own cost budget and performance needs. 3. Attenuation per length, power handling capability, Coax Voltage vs. Current MUF, affordability 4. RF Fittings; what s best crimp, clamp, solder, or compression? 5. Solid center vs. stranded coax 6. How to choose; Hardline, Times Microwave LMR style, Beldon, Wireman? 7. Maximum Usable Frequency vs. cable diameter, it not entirely intuitive. 8. RF bandwidth of coaxial cables 9. Waveguide, why it s so great! 10. Answer to the RG-58 and RG-174 question

Link Budget, how much signal do I really need, how much signal can I afford to loose? Chasing centibels, 10 centibels = 1 Decibel How Much Transmission Line Loss is too Much? What does the 0.5 db of signal loss sound like in my RX? 1.0 and 2.0? How much did that 0.5 db cost me? Where do I invest my antenna system money? The Coax, The Tower, or The Antenna?

Vector Network Analyzers (VNA=best Antenna System Testers) 1. Bird watt meter lies, lies, and more damn lies 2. Return loss a new way to think about forward and reflected power, and SWR 3. Frequency vs. reflection amplitude is RL mode 4. Distance to fault mode 5. Cable insertion loss mode 6. My new antenna operates at 50KW I want to fully test it before I apply full power. I don t want to burn it up! 7. Ask me about commercial antenna fires, they are real and happen all the time

Bird 43 requires a 50 Ohm System to provide accuracy in the Meter. When we have reflected power we have additional errors. The Bird is by it s dependence on the associated transmitter is a very narrow band device. Only looks at a small sliver of RF energy. Vulnerable to standing wave errors. Bird has an published specification accuracy of 5% of the slugs value. If you use a 2500 Watt Slug the measurement error could be 125 watts higher or lower, plus if there is reflected power, errors can be even higher, meter deflection errors, dirty contacts, etc. Bird is a pass fail meter, if it says the antenna is bad its likely bad, if it says its good it may be good or it may be bad.

Ask me about Broadcast Antenna fires, they are real and happen all the time