Gas plug-in hose, straight-through form. Instructions for Use. suitable for gas socket model G2019T, G2016T. G2023 from 01/1990.

Similar documents
Profipress G. Instructions for Use. Year built: from 01/1998 en_int

Geopress. Instructions for Use. Year built: from 01/2004 en_int

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 03.

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Type BBS-03, BBS-05, BBS-06, BBS-25

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 06.

Pressure maintenance valve SDV-P / SDV-P-E

3-port seat valves with externally threaded connection, PN 16

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Gas Pressure Regulator HON 300

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Quick reference. Quick reference

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Installation and Maintenance Instruction Manual

Siphon vessel / Priming aid

Operating and maintenance manual Filter and reducing station Series / 1.0

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

TECHNICAL DATA. Trimpac 244a. September 16, 2013

2-port and 3-port valves PN 16

Pressure Switches Application Guideline

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

2-port seat valves PN25 with externally threaded connections

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

OPERATING INSTRUCTIONS

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

for the of and the EM55-1

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Transport of gas tanks for motor vehicles

patented standards SAFETY QUICK COUPLINGS EXPERTISE AT THE SERVICE OF SAFETY AND PERFORMANCE a n d ot h e r p e n di n g

Operating instructions - Translation of the original -

O NEof Premium tools for professionals!

1200B2 Series Service Regulators. Instruction Manual

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

453 Series Steam Heated Vaporizing Regulator

Instruction Manual SB02, SB03, SB04 All metal flow limiter

User guide DIAPHRAGM SEALS. Industrial instrumentation for Pressure and Temperature

Two-stage valve type NE

Two-port valves, male threaded, PN25

Operating Manual VSA100A. tina29e1 ( )

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation and Maintenance Instruction Manual

Operating manual for Material pressure tanks Vol./1 and Vol./2

1800C and 1800C-HC Series Service Regulators

JRGURED Pressure reducing valves

Safety shut-off valve S 50. Product information

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Instruction Manual Dräger MSI P7 and MSI P7 plus

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

WE SAY: CLEANLY SEPARATED SYSTEMS = ELKO-MAT EDER!

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

KSB Delta Compact Type Series Booklet

Operating instructions - Translation of the original -

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Operating instructions - Translation of the original -

6301 TYPE CAST IRON SAFETY VALVES

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

RG3100 and RG3100Ice Regulator System

Speed control assembly model A-1

2-port and 3-port seat valves, PN16

Instruction Manual Contact Pressure Vacuum Gauge

CAST IRON SAFETY VALVE TYPE 6301

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Engineering Data Sheet

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

ST/SG/AC.10/C.3/2016/8. Secretariat. United Nations. Transport of gas tanks for motor vehicles. Introduction

REMS Swing INSTRUCTION MANUAL SINGLE-HAND TUBE BENDER SWING ANCRA

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Operating instructions - Translation of the original -

6-5 Maintenance Manual

A18W35_MASE 130_F_EN MANUAL

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints

Operating Instructions Hand Test Pump BHP 700

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

64 Series Pressure Reducing Regulators

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

safety Shut-Off Valve HON 721

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Transcription:

Gas plug-in hose, straight-through form Instructions for Use suitable for gas socket model G2019T, G2016T Model Year built: G2023 from 01/1990 en_int

Gas plug-in hose, straight-through form 2 from 12

Table of contents Table of contents 1 About these instructions for use 4 1.1 Target groups 4 1.2 Labelling of notes 4 1.3 About this translated version 5 2 Product information 6 2.1 Standards and regulations 6 2.2 Intended use 7 2.2.1 Areas of use 7 2.2.2 Media 8 2.3 Product description 8 2.3.1 Overview 8 2.3.2 Threaded connection 8 2.3.3 Markings on components 9 2.3.4 Compatible components 9 2.3.5 Technical data 9 2.4 Information for use 9 2.4.1 Corrosion 9 3 Handling 10 3.1 Assembly information 10 3.1.1 Mounting instructions 10 3.2 Assembly 10 3.2.1 Connecting the gas plug-in hose 10 3.2.2 Leakage test 11 3.3 Maintenance 11 3.4 Disposal 12 Gas plug-in hose, straight-through form 3 from 12

About these instructions for use 1 About these instructions for use Trade mark rights exist for this document, further information can be found at www.viega.com/legal-notices. 1.1 Target groups The information in this instruction manual is directed at the following groups of people: contract installers registered in the installers' register of a utility company professional specialist companies for the construction, maintenance and alteration of a natural or liquid gas system Liquid gas systems may only be constructed, maintained or altered by companies that have the necessary qualification and experience. It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, service this product. This restriction does not extend to possible operating instructions. The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use. 1.2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs. DANGER! This symbol warns against possible life-threatening injury. WARNING! This symbol warns against possible serious injury. CAUTION! This symbol warns against possible injury. NOTICE! This symbol warns against possible damage to property. Gas plug-in hose, straight-through form 4 from 12

About these instructions for use Notes give you additional helpful tips. 1.3 About this translated version This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW). Some passages in the text may refer to technical codes in Europe/ Germany. These should serve as recommendations in the absence of corresponding national regulations. The pertinent national laws, standards, regulations and guidelines, as well as other technical guidelines, have priority over German/European guidelines in this manual: The information is not binding for other countries and territories and should, as mentioned, be considered as support. Gas plug-in hose, straight-through form 5 from 12

Product information 2 Product information 2.1 Standards and regulations The following standards and regulations apply: Regulations Scope / Notice Areas of use DVGW-TRGI 2008 DVFG-TRF 2012 DIN 3383-1 DIN EN 15069 Gas installations Liquid gas systems Connection with all gas sockets Connection with all gas sockets Media DVGW Worksheet G 260 Gas quality Overview DIN 3383-1 DIN EN 14800 Gas socket Gas plug-in hose Threaded connection DIN EN 10226-1 DIN 30660 DIN EN 751-2 Threaded pair Permitted sealants Permitted sealants Corrosion DIN 30672 DVGW-TRGI 2008, Point 5.2.7.1 DVFG-TRF 2012, Point 7.2.7.1 Outer pipes Outer pipes Mounting instructions DVGW-TRGI 2008 DVFG-TRF 2012 Exceptions, selection criteria, and arrangement of the components Exceptions, selection criteria, and arrangement of the components Gas plug-in hose, straight-through form 6 from 12

Product information Connecting gas plug-in hose DIN EN 377 Fitting grease Leakage test DVGW-TRGI 2008, Point 5.6 DVFG-TRF 2012, Point 8 Testing and initial commissioning of a liquid gas system Maintenance DVGW-TRGI 2008 Appendix 5c Operation and maintenance of gas installations 2.2 Intended use The use of the model for areas of use and media other than those described must be approved by the Viega Service Center. 2.2.1 Areas of use The gas plug-in hose is intended and certified for the following uses: for the flexible connection of fixed gas devices for gas devices with electrical connection for connection with all gas sockets pursuant to applicable regulations, see Ä Chapter 2.1 Standards and regulations on page 6 up to maximum 2.0 mlong in domestic installations (CE certification up to 2.0 m in length) outside up to a length of 6.0 m (no CE certification) Use is possible in the following areas among others: Gas installations Liquid gas installations For planning, execution, modification and operation of gas installations, observe the applicable regulations, see Ä Chapter 2.1 Standards and regulations on page 6. Gas plug-in hose, straight-through form 7 from 12

Product information 2.2.2 Media The model is also suitable for the following media, amongst others: Gases, see Ä Chapter 2.1 Standards and regulations on page 6 Liquid gases, only in the gaseous state for domestic and commercial applications, see Ä Chapter 2.1 Standards and regulations on page 6. 2.3 Product description 2.3.1 Overview The model has a CE approval pursuant to the applicable regulations, see Ä Chapter 2.1 Standards and regulations on page 6. The model is equipped as follows: inlet side with standard plug pursuant to applicable regulations, see Ä Chapter 2.1 Standards and regulations on page 6 outlet side with Rp internal thread corrugated hose made of stainless steel inside stainless steel mesh with plastic coating on the outside hose socket made of plastic (PPO) The model is available in the dimension Rp ½ in the following lengths: L 500 / 750 / 1000 / 1250 / 1500 / 2000 / 2500 / 3000. 2.3.2 Threaded connection Prerequisite for a threaded connection, which seals via a thread, is a threaded pair in accordance with applicable regulations, see Ä Chapter 2.1 Standards and regulations on page 6. Pursuant to these regulations, a permitted threaded pair comprises a conical external thread and a cylindrical internal thread, e. g. R ¾ and Rp ¾. Only use commercially available and chloride-free, DVGW approved sealant in accordance with the applicable regulations to seal threads, see Ä Chapter 2.1 Standards and regulations on page 6. Establish the threaded connection first and the plugged connection next. Gas plug-in hose, straight-through form 8 from 12

Product information 2.3.3 Markings on components The model is marked as follows: Flow direction indicator DVGW writing and certificate number Writing DIN EN 14800 / CE 0085 HTR marking Class AMS classification in acc. DIN 3383-1 yellow strip for gas 2.3.4 Compatible components The model is compatible with the gas socket model G2016T and G2019T. Please contact the Viega Service Center for questions on this subject. 2.3.5 Technical data Observe the following operating conditions for the installation of the model: Operating temperature Operating pressure -20 C up to +70 C 0.01 MPa (0.1 bar) 2.4 Information for use 2.4.1 Corrosion Depending on the area of use, corrosion protection measures may have to be taken into account. For corrosion protection, comply with the applicable directives, see Ä Chapter 2.1 Standards and regulations on page 6. Do not use the model in aggressive surroundings. Avoid contact with aggressive building materials such as materials containing nitrite or ammonium. Gas plug-in hose, straight-through form 9 from 12

Handling 3 Handling 3.1 Assembly information 3.1.1 Mounting instructions Checking system components System components may, in some cases, become damaged through transportation and storage. Check all parts. Replace damaged components. Do not repair damaged components. Contaminated components may not be installed. Mounting conditions Observe the following when mounting: Observe flow direction indicator. Do not install the model in heat zones (e. g. with hot emissions or strong heat radiation. Use suitable tools. Do not tension. Avoid heavy bending (bending radius at least 40 mm). Exceptions, selection criteria and the arrangement of the components are described in the applicable regulations, see Ä Chapter 2.1 Standards and regulations on page 6. 3.2 Assembly 3.2.1 Connecting the gas plug-in hose When mounting, also observe the instructions for use of the relevant gas socket. Produce the threaded connection first then the plug connection. If the plug is difficult to connect, lubricate the plug with tap grease in acc. with the applicable directives, see Ä Chapter 2.1 Standards and regulations on page 6. Gas plug-in hose, straight-through form 10 from 12

Handling Push the plug as far as it will go into the gas socket. The markings on the gas socket and the plug must match. Turn the plug anti-clockwise by 90. The connection is secured in this way. 3.2.2 Leakage test The installer must perform a leakage test (load and leakage test) on the gas installation before commissioning. Observe the applicable regulations, see Ä Chapter 2.1 Standards and regulations on page 6. The gas plug-in hose must not be included in the leakage test. The connection must be checked for leaks by suitable means after the gas has been filled. Document the result. 3.3 Maintenance Gas installations must be given a visual inspection, e. g. by the owner, once a year. Particular attention should be paid to damage, e. g. kinks or corrosion. Serviceability and leak tightness must be checked every twelve years by an installation contractor. To be covered by the warranty and to ensure the safe operation of the gas installations, operate and maintain them as intended. For more detailed information, refer to the applicable regulations, see Ä Chapter 2.1 Standards and regulations on page 6. Gas plug-in hose, straight-through form 11 from 12

Handling 3.4 Disposal Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements. Gas plug-in hose, straight-through form 12 from 12