SOLAR 93 THE 1993 AMERICAN SOLAR ENERGY SOCIETY ANNUAL CONFERENCE. Washington, DC April 22028,1993. Editors: S. M. Burley M. E.

Similar documents
Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Hydrostatics Physics Lab XI

ANNUAL GROUND TEMPERATURE MEASUREMENTS AT VARIOUS DEPTHS

Development of High-speed Gas Dissolution Device

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Available online at ScienceDirect

CubeSat Balloon Drag Devices: Meeting the 25-Year De-Orbit Requirement

KINETIC THEORY OF GASES

5.0 Neutral Buoyancy Test

aeration and mixing systems

GEOTHERMAL WELL COMPLETION TESTS

Old-Exam.Questions-Ch-14 T072 T071

TECHNICAL BULLETIN CRYOGENIC APPLICATION SERVICES. website:

Experimental Study of Hydrogen Release Accidents in a Vehicle Garage

3. A fluid is forced through a pipe of changing cross section as shown. In which section would the pressure of the fluid be a minimum?

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance

MEMORIAL UNIVERSITY OF NEWFOUNDLAND Faculty of Engineering and Applied Science FLUID MECHANICS LABORATORY PIPE FRICTION

Tutorial. BOSfluids. Relief valve

HW-1: Due by 5:00 pm EDT on Wednesday 13 June 2018 to GradeScope.

2 Available: 1390/08/02 Date of returning: 1390/08/17 1. A suction cup is used to support a plate of weight as shown in below Figure. For the conditio

Workshop 1: Bubbly Flow in a Rectangular Bubble Column. Multiphase Flow Modeling In ANSYS CFX Release ANSYS, Inc. WS1-1 Release 14.

Designing Wave Energy Converting Device. Jaimie Minseo Lee. The Academy of Science and Technology The Woodlands College Park High School, Texas

Crab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework)

Sizing Pulsation Dampeners Is Critical to Effectiveness

UNDER DOD DIRECTIVE 5200,20 AND DISTRIBUTION STATEMENT A

Experimental Study of an Air Lift Pump

Code Basic module and level control complete with optionals code

CHAPTER 6: PERMEABILITY MEASUREMENT

ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

Transient Analyses In Relief Systems

WP2 Fire test for toxicity of fire effluents

CFD for Ballast Water & Bio-fouling Management

Lab Problems. Lab Problems for Chapter Fluid Characterization by Use of a Stormer Viscometer L-1

Modelling of the Separated Geothermal Water Flow between Te Mihi flash plants

Cable in Conduit Conductor (CICC) quench modelling

International Journal of Petroleum and Geoscience Engineering Volume 03, Issue 02, Pages , 2015

RESIDENTIAL WATER DISTRIBUTION

Fig. 2. M.I. Yaroslavtsev, 2002

Permeability. Darcy's Law

Expert Hydrostatic Level Transmitters

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

Measurement of Low GAS & Liquid Flows

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

NSPS SUBPART Ka Check-off Form JULY 11, LAFAYETTE ROAD NO., ST. PAUL, MN

UsER manual for Watersens ph -REDOX

Experiment. THE RELATIONSHIP BETWEEN VOLUME AND TEMPERATURE, i.e.,charles Law. By Dale A. Hammond, PhD, Brigham Young University Hawaii

SPE Copyright 2012, Society of Petroleum Engineers

Reflux Condensation with Various Non-Condensable Gases

Application of Simulation Technology to Mitsubishi Air Lubrication System

Flow and Mixing in the Liquid between Bubbles

MET 335W Fluid Mechanics Laboratory. Lab 1: Bourdon Tube Calibration. Nick Peak

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Irrigation &Hydraulics Department lb / ft to kg/lit.

CFD Analysis of the Anti-Surge Effects by Water Hammering

29 Pressure, Temperature relationship of a gas

Physics 7b Midterm Exam #1 Fall Name: Disc. Section SID

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Drilling Efficiency Utilizing Coriolis Flow Technology

By Syed Ahmed Amin Shah 4 th semester Class No 8 Submitted To Engr. Saeed Ahmed

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 1, No 4, 2010

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Experimental Determination of Temperature and Pressure Profile of Oil Film of Elliptical Journal Bearing

SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG A SCALE MODEL OF THE LHC TUNNEL

Experiment 13: Make-Up Lab for 1408/1420

ME 200 Thermodynamics I Spring 2010 (Last) (First) Thermo Number: CIRCLE YOUR LECTURE BELOW

Objectives. Materials TI-73 CBL 2

Shri Krishna Test House, B-70/1, Gali No. 8, New Modern Shahdara, Mansarover Park, Delhi. Discipline Mechanical Testing Issue Date

Quiz #1 Thermodynamics Spring, 2018 Closed Book, Open Appendices, Closed Notes, CLOSED CALCULATORS

Journal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1)

Cover Page for Lab Report Group Portion. Pump Performance

THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng. January 2003

Increase in Evaporation Caused by Running Spa Jets swhim.com

Gas Laws. Introduction

Applications of ELCIRC at LNEC

Bubble Dynamics in a Vibrating Liquid. By: James Wymer, Jaggar Henzerling, Aaron Kilgallon, Michael McIntire, Mohammed Ghallab

Steam generator tube rupture analysis using dynamic simulation

[2] After a certain time, the temperature of the water has decreased to below room temperature.

Cavitation in Valves

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

1.5 m. 2.4 m. Fig the pressure exerted by the oil on the base of the tank, the force exerted by the oil on the base of the tank.

SURFACE CASING SELECTION FOR COLLAPSE, BURST AND AXIAL DESIGN FACTOR LOADS EXERCISE

MODELLING OF FUME EXTRACTORS C. R.

Laboratory studies of water column separation

LEAP CO 2 Laboratory CO 2 mixtures test facility

Study on Marine Propeller Running in Bubbly Flow

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Körting Liquid Jet Vacuum Ejectors

Section 2 Multiphase Flow, Flowing Well Performance

An Experimental Performance Study of Vortex Tube Refrigeration System

ALICE SPD cooling system

Disc diffuser ELASTOX -T

OPERATING INSTRUCTIONS

Special edition paper

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

Process Nature of Process

Underground irrigation

PHYS 101 Previous Exam Problems

Transcription:

SOLAR 93 THE 1993 AMERICAN SOLAR ENERGY SOCIETY ANNUAL CONFERENCE Washington, DC April 22028,1993 Editors: S. M. Burley M. E. Arden American Solar Energy Society U.S. Section of the International Solar Energy Society 2400 Central Avenue, Suite G-l Boulder, CO 80301 Printed on recycled paper

TANK STRATIFICATION WITH A FLEXIBLE MANIFOLD D.E. Adams and J.H. Davidson Solar Energy Applications Laboratory Colorado State University Fort Collins, CO 80523 USA Use of a flexible, porous manifold to increase the level of storage tank stratification in domestic solar water heating systems is studied in a 372-liter storage tank. The initial tank temperature profile, inlet temperature, and test duration are varied in three testing schemes. Flow rate is 0.07 l/s. Stratification level is quantified by vertical temperature profiles and a new dimensionless mix number based on the energy in the storage tank weighted by vertical location. The mix number ranges from 0 to 1, with 0 representing a perfectly stratified tank and 1 representing a fully mixed tank. Results show that under operating conditions typical of direct, constant flow rate solar systems, an orlon manifold is 48 percent more effective than a conventional drop-tube at achieving stratification. over a range of temperatures and flow rates. Flexible manifolds adapt to different operating conditions because pressure gradients in the tank and the manifold are matched continuously by variations in the cross-sectional area of the manifold. The purpose of this study is to determine the level of tank stratification that can be maintained in a direct solar system using conventional flow rates and a flexible, fabric manifold. Stratification is characterized by vertical temperature profiles and a new mixing number based on the height weighted energy in the tank. Performance of the flexible manifold is compared to that of a conventional drop tube inlet. Thermal stratification in solar storage tanks is a critical factor in the design of effective water heating systems. Methods of increasing stratification include: operating with flow rates low enough to turn over the tank only once a day ( single-pass ), isothermal operation, and/or use of a stratification enhancing distribution manifold. Manifolds have the advantage over the other options of providing tank stratification without requiring modifications in system operation. Manifolds can be made of either rigid porous tubes or flexible porous fabrics (l-6). Design of these devices is based on matching the pressure gradients of the manifold fluid and the tank fluid to prevent inflow or outflow from the manifold until the fluid returning Erom the collector reaches the location in the tank where tank temperature equals mm fluid temperature. Because rigid manifolds use vertical resistance elements to match pressures, they are difficult, if not impossible, to design to operate effectively The experimental facility includes an insulated, plastic 372 liter water storage tank (UA = 2.7 W/K), a 310 liter electric water heater used to simulate collector return water, and a cold mains water supply. Tank temperatures are measured with 19 T-type thermocouples mounted in a thermocouple tree. Inlet water temperatures are measured with a thermocouple inserted in the pipe just upstream of the inlet. A turbine flow meter is used to measure the volumetric flow rate of the water entering the storage tank. The conventional inlet is a vertical 2.54cm diameter PVC tube which delivers water to the top of the tank. The flexible manifold, shown in Fig. 1, is composed of a knit orlon sleeve clamped to a modified inlet tube. The fabric is also attached to a weight which rests on the bottom of the storage tank so that the manifold does not float to the top of the tank as air bubbles attach to the fabric. The vertical momentum of the incoming fluid is reduced by forcing the water from holes drilled around the circumference of a, 277

plugged drop tube. Flow from the tank into the manifold is not possible because the manifold collapses until the difference between the tank and manifold pressures is 10. Once the manifold fluid reaches the tank depth at which its density equals the tank fluid density, the fabric expands allowing flow from the manifold to the tank. MOMENTUM DIFFUSER 4. lnlet SECTION 73mm DIA _ I Time (minutes) 1 o- 10 Tinlet ( c) -1.-w.,. I 50 10-20 40 20-30 30 30-40 30 40-50 40 50-60 50 60-70 40 70-80 30 80-90 40 L FLEXIBLE MANIFOLD Fig. 1. Flexible manifold design 3. TESTING I 1030mm 1163mm Three testing schemes are used to evaluate the two inlet designs. In each test, as water enters the storage tank from the inlet at the top of the tank, water is drained from the bottom of the tank at the same fixed flow rate (0.07 l/s based on conventional flow rates of 0.01-0.02 kg/s per m2 of collector area). Tank temperature profiles, inlet water temperature, and flow rate are recorded at l-minute intervals. In Scheme I, the upper half of the tank is filled with hot (50-55 C) water and the bottom half is ftiled with cold (15-20 C) water. Water is then delivered to the tank at a constant intermediate temperature (30 C). The length of the test is 48 minutes which is sufficient time for the cold water to be removed from the tank (assuming no mixing occurs). In Schemes II and III, the storage tank is initially filled with 15-20 C water and test duration is 90 minutes, the time necessary to turn over the tank. In Scheme II, water is input at 5O C. In Scheme III, temperature of the inlet water is varied every 10 minutes as shown in Table 1. 4. RESULTS In a preliminary study of 13 synthetic fabrics, a 7.3 cm diameter, orlon manifold was determined to be the most effective at achieving and maintaining stratification (6). In general, materials which perform most effectively are loosely-knit synthetic fabrics which stretch easily in one direction and maintain physical integrity even after long exposure to high temperature water (7,8). Stratification levels in the storage tank equipped with this best flexible manifold are compared to stratification levels in the same tank equipped with a conventional drop-tube. 4.1-e. Profw Normalized tank temperature profiles obtained at 8-minute intervals during Scheme I tests are plotted in Figs. 2(a) and (b), for the conventional inlet and flexible manifold, respectively. The ordinate is the normalized tank height, the distance from the bottom of the tank (Y) divided by the total tank height (H). The abscissa is the normalized tank temperature defined as the local temperature (T) minus the initial minimum tank temperature (T,) divided by the maximum initial tank temperature difference (Th-Tc). The thick solid line (final-str) represents the theoretical temperature profile that would exist at the end of the test if no mixing occurred. This ideal case is numerically predicted using a plug flow model with no mixing. The simulated tank is initially made up of isothermal disks of volume and temperature consistent with the experimental conditions. Losses to the surroundings are taken into account. The thinner solid line (final-mix) is determined theoretically by assuming that any time water enters the tank, the entire tank mixes completely. The mass weighted average temperature of the experimental tank at the beginning of a test is used as the initial condition for the mixed tank model. 278

1.0 0.8 1 0.8 *Ix 5 0.6 2 E! 0.4 0.2 0.0 O-2 O-4 0.6 0.8 1.0 T - T, TEMPERATURE - 60 Th-Tc 0.6 0.8 (a) 1.c 0.8 *lx k 0.6 CD Ei x 0.4 0.2 0.0 0.2 0.4 0.6 0.8 1.0 T - T, TEMPERATURE - cb) Th-Tc Fig. 2. Scheme I tank temperature profiles (a) conventional inlet (b) flexible manifold ( E -0 min., -8 min., -16 min., A -24 min., -32 min., z -4Omin., * -fmal(exp), - -final&r), - -fi.nal(mix)). As shown in Fig. 2(a), in the ideally stratified tank, water in the upper half of the tank remains at the initial temperature (minus losses to the surroundings), and water in the lower half of the tank is at the temperature of the incoming fluid. In both the simulated fully-mixed tank 1 0.0 3 O-2 0.4 0.6 0.8 1.0 (b) Fig. 3. Scheme II tank temperature profiles (a) conventional inlet (b) flexible manifold. ( a -0 min., + -10 min., -20 min., 4-30 min., I 40 min., 0-50 min., A -60 min., 4-70 min., I-80 min., m -fmal(exp), - -final(str), - -final( and the conventional tank, the tank is isothermal at the end of the test; however, since in the actual tank, mixing occurs only in the top half of the tank, total energy stored in the conventional tank is greater than that predicted for a fullymixed tank. This result points out the fallacy of basing level of mixing on only the slope of the temperature profile. As shown in Fig. 2(b), use of the flexible 279

manifold significantly reduces mixing. At the end of the test, water temperatures in the upper half of the tank are only slightly lower than those predicted by the stratified tank model and in the lower half of the tank, measured water temperatures are only slightly greater than in an ideal tank. Tank temperature profiles for Scheme II tests are plotted in Fig. 3. Temperature is plotted at lo-minute intervals as a function of normalized vertical position. In both these tests and Scheme III tests, temperatures are not normalized since there are not constant hot and cold bounding tank temperatures. Inspection of the tank temperature profile after the first 10 minutes reveals that the temperature at the bottom of the tank is increased when using the conventional inlet. This temperature rise indicates that some mixing occurs throughout the entire tank. During this same time, the flexible manifold restricts mixing to the top third of the tank. Tank temperature profiles obtained under Scheme III are plotted in Fig. 4. As in Scheme II, mixing occurs throughout the conventional tank after only 10 minutes and at the end of the 90 minute test, the tank is nearly isothermal. In contrast, as shown in Fig. 4(b), use of the flexible manifold restricts mixing and in the lower portion of the tank, the final temperature profile is nearly identical to that predicted for a stratified tank. In the upper part of the tank, measured temperatures are as much as 10 C less than in the ideal case, but are significantly higher than in the conventional tank., 0.6 0.4= 0.2' oo- o-2 l.ol-j -- 0.8 4X c-( 0.6 o-4 0.6 0.8 1.0 GO A new quantitative measure of tank stratification is based on the energy in the storage tank weighted by vertical location. The mix number is, MIX#= ( M*tr -MUP) ( Mdr -LX) where M is the first moment of energy given by, for a tank of height H, with n isothermal nodes. The distance measured from the bottom of the tank to the center of node i is yi, and Et = pic,,, V,T,. The mix number has a value of zero for a tank with a measured moment of energy (Mexp) equal to that predicted by the fully stratified tank model (M&. Mix number equals one if the experimental moment of energy equals the moment of energy predicted by the fully mixed tank model (Mmix). (1) -2 O-4 0.6 0.8 1.0 Fig. 4. Scheme III tank temperature profiles (a) conventional inlet (b) flexible manifold ( E -0 min., + -10 min., -20 min., 0-30 min., I-40 min., Cl -50 min., A -60 min., A -70 min., I -80 min., * -fmal(exp), I -final@), - -fmal(mix)). Mix numbers for the conventional drop-tube inlet and the flexible manifold are compared in Table 2. As expected from tank temperature profiles, the mix number associated with the flexible manifold is much less (closer to the perfectly stratified value of zero) than the mix number calculated for the tank using the conventional drop-tube. 0 280

The use of the flexible manifold improves stratification under each of the three testing schemes compared to the conventional drop tube inlet. Under Scheme III, with the realistic conditions of variable inlet temperature associated with variable insolation for constant flow rate systems, the flexible manifold reduces mixing by 48 percent compared to the conventional inlet. 2 MIX NUMB= Inlet Type Scheme Scheme Scheme I II m Conventional,620.556,737 Drop-Tube Flexible,161,401.383 1 Manifold 1 I I 1 Thesis, Civil Engineering, Colorado State University, November 1992. (7) DuPont, Comparative Heat Resistance of Fibers, Technical Bulletin X-56,1956. (8) DuPont, Properties of DuPont Industrial Filament Yarns, Technical Bulletin X-272, 1988. A new mix number based on height weighted energy gives an accurate indication of thermal stratification in solar storage tanks. Mix numbers obtained in a 372-liter tank indicate that a knit orlon flexible manifold is 48 percent more effective than a conventional drop-tube at achieving tank stratification. 6. REFERENCES (1) Loehrke, R-I., Holtzer, J.C., and Gari, H-N., Stratification Enhancement in Liquid Thermal Storage Tanks, Journal of Energy, Vol. 3, pp. 129-130, 1979. (2) Sharp, M-K., Loehrke, R-I., Stratified Thermal Storage in Residential Solar Energy Applications, Journal of Energy, Vol. 3, No. 2, pp. 106-113, 1979. (3) Gari, H.N., and Loehrke, R-I., A Controlled Buoyant Jet for Enhancing Stratification in a Liquid Storage Tank,. Journal of Fluids Engineering, Vol. 104, pp. 475-481, 1982. (4) Fanney, A.H., Klein, S-A., Thermal Performance Comparisons for Solar Hot Water Systems Subjected to Various Collector and Heat Exchanger Flow Rates, u Energy, Vol. 40, pp. 1-12, 1988. (5) Davidson, J-H., Carlson, W-T., Duff, W-S., Impact of Component Selection and Operation on Thermal Ratings of Drain-Back Solar Water Heaters, Journal of Sm mineerine, Vol. 114, No. 4, pp. 219-226, 1992. (6) Adams, D.E., Design of a Flexible Stratification Manifold for Solar Water Heating Systems, Masters 281