A New Test Setup for Testing Polyethylene Tubes under Constant and Cyclic Internal Pressures

Similar documents
SEMATECH Provisional Test Method for Pressure Cycle Testing Filter Cartridges Used in UPW Distribution Systems

NASA AEROSPACE PRESSURE VESSEL SAFETY STANDARD

CONVECTION SECTION FAILURE ANALYSIS AND FITNESS-FOR-SERVICE ASSESSMENT

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

ASSESSMENT AND ANALYSIS OF PIPELINE BUCKLES

Long Term Strength And It s Consequences for PEX

A STUDY ON THE ENTRAPPED AIR BUBBLE IN THE PLASTICIZING PROCESS

BAM - 3.2: Section Pressure Equipment Pressure Receptacles; Fuel Gas Storage Systems 26 th September 2014

FEA case Study: Rubber expansion joint for piping systems

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

MAE 322 Machine Design Lecture 5 Fatigue - 2. Dr. Hodge Jenkins Mercer University

Flow in a shock tube

Technical Data Sheet. R&M Closures

H 2 O Bubble Chamber Superheated Active Target System. Safety and Systems Overview B. DiGiovine

PMI Pulse Decay Permeameter for Shale Rock Characterization Yang Yu, Scientist Porous Materials Inc., 20 Dutch Mill Road, Ithaca NY 14850

GEOTHERMAL WELL COMPLETION TESTS

Slow Crack Growth-Notches-Pressurized Polyethylene Pipes

Tightening Evaluation of New 400A Size Metal Gasket

2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

Causes and Remedies to 7 Instability Patterns in Blown Film Extrusion

DVS Technical Codes an Bulletins

A FINITE ELEMENT PROCEDURE TO MODEL THE EFFECT OF HYDROSTATIC TESTING ON SUBSEQUENT FATIGUE CRACK GROWTH

Liquefied gas cargo tanks and process pressure vessels

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

STRUCTURAL INTEGRITY EVALUATION OF CNG COMPOSITE CYLINDERS BY ACOUSTIC EMISSION MONITORING

Sense Element Pump Ripple Fatigue

Courses of Instruction: Controlling and Monitoring of Pipelines

Study to Establish Relations for the Relative Strength of API 650 Cone Roof Roof-to-Shell and Shell-to- Bottom Joints

Displacement-based calculation method on soil-pile interaction of PHC pipe-piles

EXPERIMENTAL ANALYSIS OF MECHANICAL PROPERTIES OF SELECTED TAKRAW BALLS IN MALAYSIA

SCANNING ELECTRON MICROSCOPY ANALYSIS OF ELASTOMERIC O-RINGS AND SPRING SEALS FRACTURED DURING RAPID GAS DECOMPRESSION.

Evaluation of Hydropath Clearwell Technology On Carbonate Brine Scaling Using Tube Blocking Method

Lab 1. Adiabatic and reversible compression of a gas

BUBBLER CONTROL SYSTEM

DVS Technical - Codes and Bulletins. Table of Contents

ISO 3724 INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using particulate contaminant

THE STUDY ON THE INTERNAL TEMPERATURE CHANGE OF TYPE 3 AND TYPE 4 COMPOSITE CYLINDER DURING FILLING

Plastic non-symmetric bifurcation buckling of circular cylinders under uniform external hydrostatic pressure

Valves. Controllers. Valves Two Types

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Plasma Sources and Feedback Control in Pretreatment Web Coating Applications

Time Pressure Dispensing

MODELING&SIMULATION EXTRAPOLATED INTERNAL ARC TEST RESULTS: A COUPLED FLUID-STRUCTURAL TRANSIENT METHODOLOGY

A New Way to Handle Changing Fluid Viscosity and the Full-to-empty Effect

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

CHAPTER 3 RESULTS AND DISCUSSION

Development Report. Walker Barrier 10 Ergoclean Gloveport Interface. And. Single Piece Gauntlet Performance Testing

2.1 Introduction to pressure vessels

Pressure Strength Test Requirements for Hermetic Refrigerant Compressor Housings Using Fatigue Analysis

High Density FPGA Package BIST Technique

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

BUBBLER CONTROL SYSTEM

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Limited quantities of compressed gases.

Technical Standards and Legislation: Risk Based Inspection. Presenter: Pierre Swart

Haynes 214 (UNS N07214)

6 th International Conference on Trends in Agricultural Engineering 7-9 September 2016, Prague, Czech Republic

AN ANALYSIS ON HIGH PRESSURE DYNAMIC CALIBRATORS USED IN THE DEFENSE AREAS

Flexible Metal Hose Products

and Mechanics, BP 8118 Oasis, Hassan II University, Casablanca, Morocco Qc, Chicoutimi, Quebec, Canada

DR.ING. CARLO AVANZINI PROFESSIONAL ENGINEER GRIP TEST REPORT NOVA SIRIA, ROLETTO, Premise

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

The Discussion of this exercise covers the following points:

UNIT 15 WATER HAMMER AND SURGE TANKS

SPH 4C Unit 4 Hydraulics and Pneumatic Systems

Cover Page for Lab Report Group Portion. Pump Performance

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

RELIABILITY ASSESSMENT, STATIC AND DYNAMIC RESPONSE OF TRANSMISSION LINE TOWER: A COMPARATIVE STUDY

IGEM/TD/1. Background, Development, Changes J V Haswell

Experiment Instructions. Circulating Pumps Training Panel

STRESS ANALYSIS OF BICYCLE PADDLE AND OPTIMIZED BY FINITE ELEMENT METHOD. S. Abeygunasekara 1, T. M. M. Amarasekara 2

Chapter 7. SCIIB Pressure Sensor Performance Evaluations: Experiments, Results and Discussions

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Experimental Investigation on Transient Response of Two Stage Pressure Relief Valve

WHITEPAPER. The flowplus 16 Pressure Sensor. Physical Principles and Function

DESIGN OF SPECIALIST BAROCHAMBERS FOR THE STUDY OF BAROTRAUMA

STIFFNESS INVESTIGATION OF PNEUMATIC CYLINDERS. A. Czmerk, A. Bojtos ABSTRACT

ANL Bubble Chamber Superheated Active Target System

WATER HYDRAULIC SYSTEM FOR HIGH SPEED CYLINDER DRIVE

Heat Pump Connections and Interior Piping

Damage evaluation for Type-ll CNG cylinder by the analysis of AE parameters

FRIGOFLEX is an innovative system designed for the conveyance of R134, R404, R407, R410 refrigerant gases and other specific fluids.

AIAA Brush Seal Performance Evaluation. P. F. Crudgington Cross Manufacturing Co. Ltd. Devizes, ENGLAND

MECHANICAL ASPECTS OF SUBMARINE CABLE ARMOUR

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

Experimental Investigations of the Rapid C rack Propagation Performance of Polyethylene Pipes

LEAP CO 2 Laboratory CO 2 mixtures test facility

Impact Fatigue on Suction Valve Reed: New Experimental Approach

Product Technical Bulletin #48

Instruction Manual. Pipe Friction Training Panel

APPLICATION OF ACOUSTIC EMISSION DETECTION TECHNOLOGY ON MULTILAYER BINDING HIGH PRESSURE VESSEL

Next Generation Quartz Pressure Gauges

MTS Restan. Automatic System for Residual Stress Measurement by Hole-Drilling

Increasing Importance of Rapid Crack Propagation (RCP) for Gas Piping Applications - Industry Status

2003 WJTA American Waterjet Conference August 17-19, 2003 Houston, Texas Paper PIPE THREADS-WHAT IS THE LIMIT?

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

STRUCTURAL INTEGRITY EVALUATION OF CNG COMPOSITE CYLINDERS BY ACOUSTIC EMISSION MONITORING

Transcription:

A New Test Setup for Testing Polyethylene Tubes under Constant and Cyclic Internal Pressures S. Vahidi, E. Schruba, Y. Sun, M. McCarthy, and Y. G. Hsuan Drexel University, Philadelphia, PA, USA Abstract A test system was designed to evaluate the failure behavior of a thin-wall small-diameter polyethylene tube under internal pressure. The test setup was capable of delivering constant (static) and cyclic (dynamic) pressure patterns as well as maintaining an elevated testing temperature to accelerate the failure. Desired pressure patterns were obtained by controlling the opening/closing duration of the solenoid valves accordingly. A watersensing system was used to detect the failure time, particularly for small brittle failure. A data acquisition system based on LabView was used to control and record the applied pressures and the failure times. The constant pressure tests were performed at 65 and 75⁰C and the cyclic pressure tests were performed at 75⁰C. The test data obtained from the constant pressure tests exhibited two distinguishable linear regions in a log-log plot of hoop stress versus failure time. Slope values of -0.034 and - 0.113 were obtained for ductile and brittle regions, respectively. A brittle failure curve with slope of -0.039 was obtained under the cyclic pressure testing condition. The slow crack growth (SCG) failure was considerably accelerated by the cyclic loading. Introduction Small-diameter polyethylene tubes are widely used as flow lines for fluids and gases in pneumatic, hydraulic, medical and many other applications [1]. One of the areas in which polyethylene tubes have recently received significant attention is development of heat exchangers using polymeric components [2]. While the service life of traditional metal based heat exchangers can be significantly decreased by corrosion and biofouling, polyethylene offers a good resistance against these parameters. In addition, polyethylene is considerably cheaper and lighter than metal [3]. In the biomedical field, polyethylene tubes have been used as catheters for accessing different parts of human body to obtain data or administrate fluids. Polyethylene is easy to fabricate and provides properties such as flexibility, inhibition of infection, and non-thrombogenicity that make it a proper candidate for this application [4]. In many applications, polyethylene tubes are subjected to internal pressures throughout their service life. This requirement, together with the fact that polyethylene, particularly high density polyethylene (HDPE) is susceptible to stress cracking [5] justifies a thorough evaluation of the time-dependent failure of polyethylene tubes under internal pressure. Under internal pressure, the time-dependent failure of polymer tubes can take place as a result of strain accumulation or SCG [6, 7]. In some applications, such as in heat exchangers, polyethylene tube can be subjected to cyclic internal pressure which is known to accelerate the SCG process, shortening the service life [8]. Although stress cracking of HDPE has been well studied, particularly for gas and fluid transmission pipes and geomembranes, there is no test standard for thin-wall and small diameter HDPE tube. This paper introduces a new test design for both constant and cyclic pressure patterns. Material and Test Specimen A thin-wall small-diameter tube with wall thickness of 0.2 mm and outer diameter of 3.175 mm was extruded using a HDPE resin with a density of 0.946 g/cm 3 and a melt index of 0.55 g/10 min at 190⁰C under 2.16 kg load. The tensile strength at yield was 22 MPa while the secant modulus at 2% was 690 MPa. Burst pressure values at 65 and 75⁰C were 1.22 MPa and 1.03 MPa, respectively. Test specimens with length of 150 mm were cut from the product for testing. Test Setup Design The test system presented in this paper was influenced by the test setup presented in ASTM D2143-15 Standard Test Method for Cyclic Pressure Strength for Reinforced Composite Thermoset Plastic Pipe [9] in which the applied pressure is generated by a pump. The pressurized fluid is alternatingly transmitted to two sets of pipe specimens to achieve cyclic pressure in each set of the specimens. During the period when the set of specimens is not pressurized, heated water is circulated through them to keep their temperature within ±2⁰C of the target temperature. However, this standard test setup could not be directly implemented for testing thin-wall small-diameter HDPE tube without making some necessary modifications. In ASTM D2143-15, the test temperature is controlled by circulating heated water through the pipe. The outer surface SPE ANTEC Anaheim 2017 / 1999

of the specimen is exposed to the ambient temperature. This leads to a temperature gradient across the thickness of the test pipe that can influence the failure time. During the circulation of hot water, small internal pressure may also be created inside the pipe, subsequently affecting the failure time. In the test standard, the pressure inside each set of the specimens is controlled by a single pressure regulator but is not measured and monitored individually. The pressurized fluid can experience a pressure drop while flowing through transmission tubing and connections before reaching the test specimens. As a result, the pressure inside each test specimen will be different from the pressure indicated by the regulator. Finally, upon failure of a specimen, the pressurized fluid can quickly escape through the failure location leading to a sudden pressure drop in the adjacent non-failed specimens. Figure 1. Pressure Testing Setup Because of the issues described above, a modified test system is required to precisely measure the applied pressures and failure times of thin-wall small-diameter polyethylene tubes. The picture and schematics of the new test setup introduced in this paper are shown in Figures 1 and 2. The system can determine failure times of the test specimens under a constant pressure and a cyclic pressure. Water was selected as the pressurizing fluid due to its incompressibility to ensure a uniform distribution of pressure throughout the tube specimen. Water was reserved in a bath heated to a constant test temperature and was then pressurized by a pump to the desired level. Pressurized water was then directed to two distinct sections: constant pressure testing section and cyclic pressure testing section. The pressure level in each section was controlled by a pressure regulator. Desired pressure patterns were obtained by controlling on/off duration of solenoid valves using Arduino based electronic platforms. Up to five tube specimens were tested simultaneously in each section. The test tube specimens were connected to compression fittings inside a heated chamber and were conditioned at the test temperature before being pressurized. Pressure inside each test specimen was measured and monitored by an in-line pressure transducer, which was connected to a data acquisition system. LabView software was programmed to record the pressure values every 200 milliseconds. Failure Detection Figure 2. Test Setup Layout Challenge in detecting failure of small-diameter polyethylene tube was experienced for brittle cracking, particularly under cyclic pressure. It was initially anticipated that failure in the test specimen will induce a rapid pressure drop that can be used as an indication of failure. However, crack resulted from SCG was very small, and thus the pressure drop was too small to be detected. Therefore, a water-sensing failure detection system was SPE ANTEC Anaheim 2017 / 2000

designed and integrated into the system. Figure 3 shows a schematic diagram of the sensing system installed around a test specimen. This system consisted of four wires that were bonded to the lower inner surface of a Plexiglas casing with spacing of 1 mm between them. The Plexiglas casing was 175 mm long and had a diameter of 25 mm. It enclosed the entire test specimen without touching. Upon failure, water (could be a small amount, depending on the type of failure) escaping through the tube wall under the test pressure was confined within the Plexiglas casing. The water then flowed to the bottom of the casing and bridged the wires, causing a change in voltage which was monitored by LabView software every 200 milliseconds. When the abrupt change in voltage was detected, a signal was sent to the Arduino board that was programmed for closing the solenoid valve in front of the specimen, stopping water from entering the failed tube. This sequential action took place within milliseconds, preventing pressure drop in adjacent specimens. desired test frequency). The maximum internal pressure was reached when the valve in front of the specimen was open and the one after the specimen was closed. Once the opening/closing functions of the valves were switched, pressurization was stopped by closing the front valve while the pressurized fluid inside the tube was released by opening the valve after the specimen. The internal pressure immediately dropped to zero. The on/off procedure took place every 2 seconds to achieve a frequency of 30 cycle/min. The sequence of controlling the two solenoid valves for producing cyclic pressure is shown in Figure 4. This cyclic pressure was applied to each test specimen until failure, when the programmed Arduino platform closed the solenoid valve in front of the test specimen. Figure 4. Solenoid valve sequence for generating cyclic pressure Figure 3. Failure detection system around the test specimen Constant Pressure Testing Section In the constant pressure testing section, a solenoid valve was installed in front of the test specimen and a ball valve after it. Initially, both valves were opened to remove all the air from the test specimen as water flowed through it. Then, the ball valve was closed manually while the solenoid valve was kept open. A constant pressure was maintained and monitored in each specimen by the pressure regulator and transducer until failure, when a signal was sent to the programmed Arduino to close the solenoid valve. Cyclic Pressure Testing Section In the cyclic pressure testing section, solenoid valves were installed in front of and after each of the specimens. Arduino based platforms were programmed to alternatingly energize the two solenoid valves every 1 second (this duration can be modified according to the Experimental Design For the constant internal pressure testing, the test was performed at 65 and 75⁰C. Testing was performed at pressures ranged from 0.71-1.07 MPa at 65⁰C and 0.62-0.96 MPa at 75⁰C. The maximum applied pressure at 65⁰C was approximately 88% of the burst strength while it was 94% for the tests performed at 75⁰C. The failure time was recorded in ± 0.2 second. Cyclic pressure testing was conducted at 75⁰C. The applied pressure was characterized by the mean pressure value, calculated using Eq. (1): P P + P 2 max min mean = (1) where P mean is the mean applied internal pressure (MPa), P max and P min are the maximum and minimum internal pressures during each cycle. The range of mean pressures was limited to the levels that will yield brittle failure according to the results of constant internal pressure tests. The highest mean pressure SPE ANTEC Anaheim 2017 / 2001

was 0.48 MPa and the tests were performed at 0.02 MPa intervals. The failure time was recorded in ± 0.2 second. Results and Discussion The pressure value for each test specimen was measured by the pressure transducer and recorded by the LabView program. This program was also used to receive signals from the failure detection system to obtain the time-to-failure. The test result is presented by plotting hoop stress against failure time in a log-log scale. The hoop stress of the specimen was calculated based on the applied pressure using Eq. 2: PD S = (2) 2t Figure 5. Stress failure curve of HDPE tube under constant pressure where S is the hoop stress (MPa), P is the applied internal pressure (MPa), D is the inner diameter (mm), and t is the wall thickness (mm). Figure 5 shows the failure curve for the HDPE tube under a constant internal pressure testing condition. Two regions with different slopes were obtained which indicates separate mechanisms controlling the failure in each region. The region with a shallow slope indicates failure that is caused by strain accumulation (ductile region) while the failure in the region with a steep slope is attributed to SCG (brittle region) [6]. The slope values of ductile and brittle regions at two test temperatures are relatively similar; the average slope for the ductile region is -0.034 and the average brittle region slope is -0.113. Calculating the slopes from the data presented by Williams for un-notched HDPE pipes yields the values of -0.032 and -0.160 for ductile and brittle regions, respectively [10]. Similar slope values (-0.030 for ductile region and -0.190 for brittle region) were calculated for un-notched HDPE gas pipes from the study conducted by Tränkner, et al. [11]. Microscopic pictures of tubes failed under each failure mode are shown in Figures 6 and 7. By comparing the failure times of a same hoop stress at 65 and 75⁰C, it is observed that an increase of 10⁰C in temperature significantly accelerated the failure, resulting in a decrease in failure times by a factor of 40. Figure 6. Ductile failure of HDPE tube under constant internal pressure. Figure 7. Brittle failure of HDPE tube under constant internal pressure. Failure curve under cyclic pressure testing is presented in Figure 8. The highest mean hoop stress was 3.39 MPa which is below the onset of brittle region in the constant pressure test at 75⁰C. Figure 9 shows the microscopic picture of a tube specimen failed under cyclic internal pressure. The brittle nature of the cracking confirms a failure governed by SCG. The slope of the cyclic failure curve is -0.039 which is much lower than that of the brittle region under constant pressure condition. Abdelkader, et al. [12, 13] performed uniaxial fatigue tests on un-notched SPE ANTEC Anaheim 2017 / 2002

tensile specimens taken from the HDPE pipe and obtained slope values of -0.068 and -0.073. The discrepancy of the slope values may be caused by the test material and test conditions such as frequency and test setup. Figure 10. Cyclic and constant pressure test results at 75⁰C Figure 8. Stress failure curve of HDPE tube under cyclic pressure Figure 11. Crack propagation mechanism Figure 9. Brittle failure of HDPE tube under cyclic internal pressure Comparing the result of cyclic and constant pressure test at 75⁰C, indicates that the cyclic pressure has accelerated the SCG mechanism (Figure 10). This effect can be derived from the microstructural aspects of crack initiation and growth. Initially, a porous zone (inside the craze) is formed at the point of imperfection which then transforms to a fibrillated zone that holds the crack surfaces together [14]. Eventually, fibrils begin to fail, a new fibrillated zone is formed and crack propagates through the material [15]. This process is shown in Figure 11. Under cyclic pressure, fibrils are stretched and compressed during each cycle. It causes buckling, bending, or crushing of the fibrils and therefore accelerates the process of fibril failure and crack growth, leading to shorter failure times and different failure mechanism than the SCG under constant pressure testing condition. Conclusions A new test system was designed for assessing the failure behavior of thin-wall small-diameter HDPE tube at 65 and 75⁰C under constant and cyclic internal pressures. The challenge of pressure variation within each test specimen and detection of small failures, particularly under cyclic pressures, were resolved. The failure curves obtained from the constant pressure testing clearly yielded two distinguished regions controlled by strain accumulation and SCG failure modes. The slope of each region matched well with those values found in the literature for HDPE pipes. An acceleration of SCG was observed under cyclic pressure loading, but the slope of the failure curve is much lower than that of the constant pressure testing. Failure times were found to be highly affected by temperature and pressure levels, hence a precise measurement of these two test parameters was emphasized in this new test system. SPE ANTEC Anaheim 2017 / 2003

References 1. D. Celentano, et al., International Journal of Pressure Vessels and Piping. 134, 82-91 (2015). 2. L. Zaheed and R. J. J. Jachuck, Applied Thermal Engineering, 24, 2323-2358 (2004). 3. M. A. Arie, et al., Applied Thermal Engineering, 113, 575-584 (2017) 4. L. Pruitt and J. Furmanski, JOM, 61, 14-20.3 (2009). 5. A. Chudnovsky, et al., ANTEC Conference Proceedings, 2976-2981 (2003). 6. U. W. Gedde, et al, Polymer Engineering & Science 34, 1773-1787 (1994). 7. A. Chudnovsky, ANTEC Conference Proceedings. 3, 3962-3965 (2004). 8. M. J. Kanters, et al. Polymer Testing, 50, 101-110 (2016). 9. ASTM D2143-15 Standard Test Method for Cyclic Pressure Strength of Reinforced, Thermosetting Plastic Pipe, ASTM International, West Conshohocken, PA, (2015). 10. J. G. Williams, Fracture mechanics of polymers. Ellis Horwood Limited, Market Cross House, Cooper St, Chichester, West Sussex, PO 19, 1 EB, UK, 302 (1984). 11. T. Tränkner, et al., Polymer Engineering & Science 36, 2069-2076 (1996). 12. D. Abdelkader, et al., Engineering, Technology & Applied Science Research, 4, 600-604 (2014). 13. D. Abdelkader, et al., Procedia Engineering, 101 2-9 (2015). 14. L. J. Rose, et al., Applied Polymer, 54, 2119-2124 (1994). 15. M. Parsons, et al., Journal of Materials Science, 35, 1857-1866 (2000). SPE ANTEC Anaheim 2017 / 2004