CONTINENTAL NH3 PRODUCTS PRODUCT CATALOG

Similar documents
PRODUCT SERIES: A-SF-3000BD

Precision Anhydrous Ammonia Application for John Deere Y1. SureFire Ag Systems

PRESSURE DROP CHARTS

Precision Anhydrous Ammonia Application for SureFire Commander II Y1. SureFire Ag Systems

Precision Anhydrous Ammonia Application for Y1. SureFire Ag Systems

Airblast Sprayer Calibration Worksheet

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

3/4 MPT w/ MHT Flush & Cap (80 psi) (A2)

SureFire Ag Systems Y1. Precision Anhydrous Ammonia Application for. AFS AccuControl

Panel-mounted valves Series T, Ø 22.5 mm

VB-7263 Series. Application. Features. Applicable Literature

Engineering Information. Flow Data. Flow Data. Importance of Valve Sizing. Estimating Cv or Orifice Size:

Dry Plant Measurement Information

VB-7273 Series. Application. Features. Applicable Literature

Flow Material Length. Weight GPM LPM. Style 3095

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

PRESSURE COMPENSATORS TECNORD

EC Calibrating Anhydrous Ammonia Applicators

CASH VALVE TYPE KP BACK PRESSURE VALVES

Butterfly Control Valve. DMK/6 Series

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Application Worksheet

VBS-9263 Series. Application. Features. Applicable Literature

Full Range Pressure Compensating Variable Flow Control

SPREADER CALIBRATIONS MADE SIMPLE

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

Table of Contents. We also carry a wide range of supplemental products for splash pad systems and pools.

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

Air Amplifiers & SYSTEMS

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

1 Exam Prep. Tabs and Highlights

Ultra Concentrate Dispensing System

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

ENGINEERING DATA. Engineering Data

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

TurboDraft Fire Eductor

Manual Solvent Purification System. Innovative Technology, Inc.

AIR AND VACUUM VALVES

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

VOLUMATIC WATER REGULATOR

Choosing the right miniature instrument and control valve is a snap

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

VOLUMATIC WATER REGULATOR

Specialty Products. Specialty Products Index

Livewell/Baitwell Pumps. Livewell/Aerator

NH3 Application Equipment

McFarland TriTan, LLC.

NH3 Application Equipment

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

Gas Boosters & Systems

How to measure water flow?

SIZING OF WATER PIPING SYSTEM

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

HORIZONTAL BLADDER TANK

TECHNICAL DATA. Page 1 of 12

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Pressure reducing valve, pilot operated, Model 3DR

STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Take a closer look at; Parts - Equipment Systems

Varying pump capacity affects the required hoseline diameter

40K TLX Nozzles 40K TLX

TECHNICAL DATA CAUTION

LQ Series Connectors. What is the LQ2?

SIZING OF WATER PIPING SYSTEM

Your Bonus. Steps for doing the Homework. Make sure you convert to the correct units of measure:

Models 106-RF / 206-RF Rate of Flow Control Valve

Gauge Adapters. Senior 2 1 2" [63,5] Bolt Circle Adapt ers. 22 Series ISO 9001:2008 CERTIFIED. Low pressure applications. The Measure of Excellence

Phuel Portable Control Units

FIREX200 CLEAN AGENT FIRE SUPPRESSION SYSTEM

TurboDraft. Fire Eductor Operating Instructions.

A t. VB-7323 Series. Application. Features. Applicable Literature. l/2 to 2 Screwed NPT SIEBE

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

REFERENCE WORKING PRESSURES AT APPROXIMATELY 4:1 DESIGN FACTOR, PSIG

Storage Systems and Accessories

Flow Measurement Equipment Armored Purge Meters

HIGH PRESSURE NOZZLES 2010 Catalog

Design Change Notification

PRO SINK -R 1 and 2. Dilution system CONTENTS

TECHNICAL ACCESSORIES

The Hoffman Specialty Series 2000 consists of main

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

TECHNICAL DATA. Q = C v P S

Ozone Stuff Album A Work in Progress. 03/09/2017 by J Tim Rainey DDS

TECHNICAL DATA. Q = C v P S

Tanker Fill Tests. Evaluating Direct Fill Lines DeKalb County, Alabama. November 16, Tests DeKalb County, AL

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

TECHNICAL DATA. Q = C v P S

S0300-BV-CAT-020 AIR COMPRESSOR SYSTEM, SUB SALV, 1150-CFM, 500-PSI. System - DS0130. System DS0130 7/8/2018 2:56:57 AM

VERTICAL BLADDER TANK

Transcription:

PRODUCT CATALOG October 2012

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

Continental NH3 Products A-360 MANIFOLD ORDERING INFORMATION Thank you for ordering our new A-360 manifold system. To assist in oredering the A-360 manifold system, we have come up with some formulas and charts in effort to make it a little easier. Follow the check list below to gather the correct information to ensure the correct manifold and splitter is ordered. Determine how many manifolds are desired and how many outlets in each manifold. Note that manifold outlets must be within 1 outlet of each other on each manifold. What size applicator hose is desired, 1/4", 3/8" and 1/2" are available. For bars that have 3 or more manifolds, determine how many outlets are required on the splitter Follow the charts below to determine splitter and manifold part numbers. SPLITTER SELECTION CHART The format for the splitter part number will look like this A-360SP-3 A-360SP 3 Model number A-360SP or A-360SP-J Two models available based on capacity needs, see below. Number of outlets 3-9 available from 3 through 9 outlets. *Please note that there are only 2 models available. The A-360SP and A-360SP-J, the A-360SP-J is a special Jumbo model for extremely high output, see chart below. The A-360SP model come with interchangeable stainless steel threaded orifices that the customer will install in the field when he gets them. To get the correct part number for the splitter first decide how many outlets you need on your splitter. Then we must determine how much flow is going to be going through each outlet on the splitter in Gallons Per Minute (GPM). Use one of the formulas below to determine your GPM per outlet. Take that figure and locate the flow range in the 100 or 50 psi column that best fits your application needs. Once you ve done that, stay on that row and go to the right to determine the model number for your splitter, then use the format above to determine your part number. 100 psi tank 50 psi tank Model Number Up to 12 GPM Up to 9 GPM A-360SP 12 to 25 GPM 9 to 18 GPM A-360SP-J To determine your GPM per outlet, use one of the following formulas: (#NH3 per acre X speed X tool bar width in feet X.1212 4 number of manifolds = GPM per outlet) (Gallons per minute 4 number of manifolds = GPM per outlet) (#N per acre X speed X tool bar width in feet X.1212 4.82 4 5.14 4 60 4 number of manifolds = GPM per outlet) 19

MANIFOLD SELECTION CHART The format for the manifold part number will look like this A-360MA-W-8A A-360-MA-W 8 A Model number A-360MA-W Number of outlts 3-12 Applicator hose size, A, B, or D A-360MA-C, A-360MA-J available from 3 through 12 A = 3/8" applicator hose size 3 models available based outlets. B = 1/2" applicator hose size capacity needs, see below D = 1/4" applicator hose size To get the correct part number for your manifolds, decide how many outlets you need on each manifold. Please keep in mind, all the manifolds must be within one outlet of each other. For example, if you have a 47.5 ft. bar, 19 knife on 30" spacings with a manifold system, you would need 2 = 6 outlet and 1 = 7 outlet. You cannot have 2 = 4 outlets and 1 = 11 outlet. Once you have done that, we have to determine your lbs NH2 per outlet. Use one of the formulas below to determine your lbs NH3 per outlet. Take that figure and locate the flow range in the 100 or 50 psi column that best fits your application needs. Once you ve done that, stay on that row and go to the right to determine the correct model number for your manifold. Then decide what size applicator hose you want. Use the chart above to determine the correct part number for your manifold. 100 psi tank 50 psi tank Model Number Up to 170 NH3 Up to 127 NH3 A-360MA-W 170-422 NH3 127-316 NH3 A-360MA-C ABOVE 422 NH3 ABOVE 316 NH3 A-360MA-J To determine your NH3 per outlet, use one of the following formulas: (#NH3 per acre X speed X tool bar width in feet X.1212 4 total number of outlets on the bar = NH3 per outlet) (Gallons per minute X 5.14 X 60 total number of outlets on the bar = NH3 per outlet) (#N per acre X speed X tool bar width in feet X.1212 4.82 4 total number of outlets on the bar = NH3 per outlet) A-360MA-J SPECIAL ORDER, AVAILABILITY IS LIMITED WITH NO MORE THAN 7 PORTS ON THE MANIFOLD Please keep in mind that finding the correct manifold for your application is important. We want the best distribution possible. If you find that your application range crosses over into 2 different sizes of either of the splitter or manifold, please give us a call and we can discuss your options. IF YOU HAVE ANY QUESTION, PLEASE GIVE US A CALL AT 1-800-537-5642 20

CONTINENTAL NH3 PRODUCTS P.O. Box 225323 130 Yorktown Dallas, TX 75208 214.741.6081 800.537.5642 fax 214.761.9519 www.continentalnh3.com