MECHANICAL REDESIGN OF ION EXCHANGE RESIN VESSEL BOTTOMS AT HULETT REFINERY

Similar documents
World Journal of Engineering Research and Technology WJERT

Use equation for the cylindrical section and equation or for the ends.

2.1 Introduction to pressure vessels

ENERGY BLADE 3K4. Energy Blade Installation Instructions

FEA ANALYSIS OF PRESSURE VESSEL WITHDIFFERENT TYPE OF END CONNECTIONS

Translation of the original Operating Instructions for HKS rubber compensators

STRUCTURAL ANALYSIS OF THE VACUUM VESSEL FOR THE LHCb VERTEX LOCATOR (VELO)

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

EVOLUTION OF RUPTURE DISC MANUFACTURING TECHNOLOGY AND PERFORMANCE

Safety devices for overpressure protection. Rupture discs: applications, sizing, and types

Liquefied gas cargo tanks and process pressure vessels

Transient Analyses In Relief Systems

Design and Structural Analysis of Cylindrical Shell

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Flexible Metal Hose Products

PVP2006-ICPVT

DESIGN AND DEVELOPMENT OF A RIG FOR THE PRESSURE TESTING OF WEAK VESSELS AND SUBSEQUENT WORK RELATING TO THE STRENGTH OF FLAT PLATES

Pulsed Eddy Current (PEC) Inspection through Insulation

Stress evaluation of a bicycle crank arm connection using BEM

THE PROCESS OF JOINT INTEGRITY

GUIDELINES. Systems. Pressure. Guidelines Acceptance of equipment, establishment of safe operating limits and fitness for service

CONTENTS Article NC-1000 Introduction Figures Article NC-2000 Material

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Hatch cover securing and tightness

Design of Pressure vessel for the Hydrocarbon release from the Vent Header Lines

MSC Guidelines for Independent Fuel Tanks

STRESS ANALYSIS OF BICYCLE PADDLE AND OPTIMIZED BY FINITE ELEMENT METHOD. S. Abeygunasekara 1, T. M. M. Amarasekara 2

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints

Unit 1, Fullerton Road Rotherham S60 1DJ. Tele: Fax:

Vertical and Horizontal Bladder Tanks

Design and Finite Element Analysis of Fabricated Panama chock with 225T capacity

RULES PUBLICATION NO. 52/P UNDERWATER INSPECTION OF MOBILE OFFSHORE DRILLING UNITS IN LIEU OF DRYDOCKING

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

OPENINGS AND REINFORCEMENTS 26

B a s i c S M A W ( A R C ) P r o c e d u r e s ( 1 1 C )

Design and optimization of a low pressure vessel

MSC Guidelines for Review of Gas Carrier/Barge Structures

General Inspection Guidance for Waste Management Units Requiring Air Emission Controls Under RCRA Air Standard Subpart CC

RELIEF VALVES. General Description

OIL AND GAS INDUSTRY

Installation restrictions for length of sections should also be noted.

Installation and Operating Instructions for Automotive Winch Synthetic Rope

AUTOMATIC HOSE TEST UNIT, TYPE SPU

PRESSURE RETEST. 49 CFR, (g) Co#: Vin#: DOT Spec: MAWP:

Regulations Respecting Compressed Gas Pressure Vessels

The Use of ILI In Dent Assessments

DESIGN AND ANALYSIS OF PRESSURE VESSEL

Rules for the Installation, Inspection and Testing of Air Reservoirs (Other than on Locomotives)

Fitness for Service Assessment of Ageing Pressure Vessel Experiencing External Corrosion: A Case Study

Other Si min/max. Cr min/max. 0.4/ / / / Bal.

PRESSURE SYSTEMS POLICY

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

GAR-BRO BUCKET LIFTING BAIL INSPECTION RECOMMENDATIONS G & R SERIES BUCKETS

Morgan DeLuca 11/2/2012

SPWE Series. Setup Instructions. Version 2.0

Vessel Weighing. Load Cells and Weigh Modules VPG TRANSDUCERS. Technical Note VPGT-06. Scope. Accuracy. Mode of Operation. Mechanical Considerations

Bottom End-Closure Design Optimization of DOT-39 Non-Refillable Refrigerant Cylinders

MSC Guidelines for Pressure Vessels

Applied Fluid Mechanics

ROPV R40 E Series User Manual

Challenges in Relief Design for Pilot Plants

Safety Engineering -Pressure Systems-

SEMFWE SQA Unit Code H1W9 04 Forming platework using power rolling machines

DGZfP-Proceedings BB 90-CD Lecture 4 EWGAE 2004

STRESS ANALYSIS OF PRESSURE VESSEL WITH DIFFERENT END CONNECTIONS

Coke drum Monitoring & Inspection for Fatigue Life and Safety Improvement

Airfix D-E-B Installation and operating instructions

DESIGN OPTIMIZATION OF WORK ROLL CHOCK AND BACKUP ROLL CHOCK IN COLD ROLLING MILL

ERTC PETROCHEMICAL Conference 20 st -22 nd February 2002, Amsterdam, The Netherlands

HCMTCB MATERIALS SAMPLING & TESTING PERFORMANCE CHECKLIST

PNEUMATIC STOPPERS OPERATING MANUAL. Type F G H - FOG

Engineering Data Sheet

ASME Boiler & Pressure Vessel Code Analysis of the 1497 MHz High-Current Cryomodule Helium Vessel

Free Surface Flow Simulation with ACUSIM in the Water Industry

Batch centrifuge basket design.

Proceedings of the ASME th International Conference on Ocean, Offshore and Arctic Engineering OMAE2011

Notice for Pressure Special Equipment Manufacture Licensing

Optimize Nozzle Location For Minimization Of Strees In Pressure Vessel

Design and Safety Document for the Vacuum Windows of the NPDGamma Liquid Hydrogen Target at SNS

Horizontal Bladder Tanks

The Benefits Of Composite Materials In Deepwater Riser Applications. 26 th March 2015 Hassan Saleh Senior Engineer 2H Offshore Engineering Ltd

Vertical Bladder Tanks

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (ELEVENTH REVISION)

Installation, operation & maintenance manual - original version

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

Vessel Weighing. Load Cells VPG TRANSDUCERS. Application Note VPG-06 TECH NOTE. Scope. Accuracy. Mode of Operation. Mechanical Considerations

OPERATING MANUAL DOUBLE ACTING DRILLING INTENSIFIER HYDRAULIC TYPE

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

Protecting your punching tool investment. Application-related problems and solutions

"RIGGING SAFETY IN CONSTRUCTION ENVIRONMENTS"

Subpart E. Pressure Testing

[PDF] DOWNLOAD PRESSURE VESSEL DESIGN FREE UNQUOTE BOOKS

Eaton Filtration, LLC

Made in U.S.A. Narrow-U Bike Rack Heavy Duty Submittal Sheet. Materials: Finishes: Mount Options: Setbacks:

ASSESSMENT AND ANALYSIS OF PIPELINE BUCKLES

Stress Analysis of Pressure Vessel with Different Type of End Connections by FEA

Hazard Operability Analysis

Guide for Evaluating Your Hose Assembly Supplier

Transcription:

MECHANICAL REDEIGN OF ION EXCHANGE REIN VEEL BOTTOM AT HULETT REFINERY L MITH Tongaat-Hulett ugar Ltd E-mail: leon.smith@huletts.co.za Abstract A third party inspection failure of one of the flat bottom resin vessels, combined with repeated failures of the lateral distribution system collecting the exiting liquor, caused the mechanical and process design of these vessels to be reviewed. This has resulted in modifications to the fabricated flat bottom design and the replacement of the lateral distribution system with a stone fill and top hat distribution design. This paper discusses the causes of the mechanical failure, modifications implemented and the benefits experienced after redesigning some of the ion exchange resin vessels at Hulett Refinery, which include a lower pressure drop and higher throughput. Keywords: ion-exchange resin vessel, structural design, liquid distribution, stone bed Introduction Hulett Refinery ion exchange decolourising plant consists of two sets of vessels, the primary and the secondary vessels. Brown liquor from the carbonatation plant entering the ion exchange decolourising plant is split into 5 parallel streams as it flows through the primary vessels, into a combined buffer tank. From here it splits again into 5 parallel streams and is pumped through the secondary vessels. These streams combine once again before being pumped to the rest of the process. The combination of two parallel streams in series allows for flexibility, because if one of the vessels needs maintenance the other nine can still be used. If the primary and secondary vessels were connected in dedicated pairs two vessels would be down if one needed maintenance (Figure 1). The original four primary vessels have concrete filled torispherical dished ends to create an artificial flat bottom. The fifth, which was added later, has a fabricated mild steel (boiler plate) flat bottom only. The inside of the vessels including the top of the concrete were coated to provide protection from the products in the vessels. The original Lateral Distribution ystem (LD) was installed on the artificial flat bottoms of the Concrete filled Dished End (CDE) vessels. The original distribution system consisted of a central pipe, branch collection pipes at right angles with small holes and channel beams for supporting the branch collection pipes (Figure 2). The branch collection pipes are covered with a matrix mesh that is covered in turn with filter cloth. The matrix mesh and filter cloth allows the liquid to enter the collection pipes but prevents the ion exchange resin beads from entering. Due to the difficult and time consuming process of setting the concrete in the CDEs, as was done on the first four primary vessels, it was decided that fabricated flat bottoms, as per the fifth primary vessel, should be installed for the secondary vessels together with the same LDs (Figure 2). roc Afr ug Technol Ass (2002) 76 495

= RIMARY VEEL. = ECONDARY VEEL. ECONDARY BUFFER TANK. RIMARY BUFFER TANK. D E D E D E D E DE = DIHED END BOTTOM. FB = FLAT BOTTOM. Figure 1. Diagrammatic layout of original ion exchange decolourising plant. Figure 2. Isometric view of bottom lateral distribution system. roblems Repeated failures occurred on the LDs fitted to the fabricated flat bottom vessels. These failures included bending of the distributor pipes and support channels, rupture of pipes, failure of the filter cloth and tearing off of the support lugs from the vessels cylindrical wall. 496

Later, one of the vessels with an Original Fabricated Flat Bottom (OFFB) (Figure 3) failed a statutory third party inspection by an approved inspection authority. A design check was done using Finite Element Analysis (FEA) and this indicated that excessive stresses existed in the shell above and below the bottom plate and support steel work of the flat plate. (ee Appendix A for comments on the FEA and the third party inspection.) Figure 3. Typical layout of the original fabricated flat bottom. No distributor failure occurred on the primary vessels with the CDEs from 1978 to 1999 however, failures started to occur on these bottoms after 1999. When one of the distribution systems was changed on this type of vessel, it was found that the top layer of concrete with an epoxy additive was severely corroded under the protective layer (Figure 4). Figure 4. Corroded concrete. 497

Discussion of failures Two theories on what could be the cause of the failures of the LDs were put forward and were discussed at Tongaat-Hulett ugar. The first theory is that the failure is caused by the physical expansion and contraction of the resin beads during the process cycle, which results from by the different product streams that are in contact with the resin. These streams included the liquor, resin regenerating solutions and water. The theory is that the resin beads get stuck between the bottom of the vessel and the LD. This happens when the beads are at their smallest possible size. When the beads expand during later parts of the cycle they cannot escape from underneath the distribution system, this causes the beads to apply equal forces to the laterals of the distribution system and the bottom plate, which results in the failure of the LDs. This theory becomes suspect when the failure rates of the LDs in the CDEs are compared with the failure rate of the LDs in the Original Fabricated Flat Bottom (OFFB). For the theory to hold, the failure rates should be the same for both types of bottom but big differences have been experienced (Table 1). Table 1. Comparing type of vessel and type of distribution system with failure rate. Type of vessel bottom Concrete filled torispherical dished end (CDE) Original fabricated flat bottom (OFFB) Redesigned fabricated flat bottom (RFFB) Redesigned fabricated flat bottom with top hat and stone bed (RFFB+THB) Torispherical dished end with top hat and stone bed (DE+THB) Year installed 1978 1987 1999 2001 2002 Distribution system Horizontal pipe system (see Figure 2) Horizontal pipe system (see Figure 2) Horizontal pipe system (see Figure 2) Top hat plus stone bed (THB) (see Figure 3) Top hat plus stone bed (THB) (see Figure 4) Failure rate (eriod: Number/year/vessel) 1978-1999: 0 1999-2002: 0.8 1987-1989: 0 1989-1999: 0.72 1999-2002: 2.7 18 month period: 0.67 None None The second theory is that the deflection of the bottoms is the cause of the failures of the lateral distribution system. This theory is substantiated by the failure rates in Table 1 and the calculated deflections shown in Table 2. It can be seen that the failure rate is the highest on the vessels with the highest calculated deflections. Comparing Tables 1 and 2, the question arises why the increase in failure rates of the LDs on both the CDEs and the OFFBs occurs. It was found, during a statuary third party inspection when one of the OFFBs failed this inspection that the OFFB weakens due to metal fatigue and then starts to deflect more than the calculated values. It was also found when converting one of the CDEs to a torispherical Dished End (DE) with Top Hat and tone Bed (THB) system that the top 150 mm of the concrete was severely corroded and that it would be flexible under the operating pressure of 450 kag. The increase of failures of the LDs when the bottoms weaken and flexing increases, confirms this theory. 498

Table 2. Comparing calculated deflection of different bottoms. Type of vessel bottom Concrete filled torispherical dished end (CDE) Original fabricated flat bottom (OFFB) Redesigned fabricated flat bottom (RFFB) Redesigned fabricated flat bottom with top hat and stone bed (RFFB+THB) Torispherical dished end with top hat and stone bed (DE+THB) Year installed 1978 Calculated deflection at operating pressure None Deflection suspected, magnitude unknown 1987 4.21 mm 1999 2.47 mm 2001 2.47 mm 2002 No deflection calculations done. None required Action and solutions The failed OFFB was replaced by a RFFB. Appendix B provides comments on the FEA of the RFFB and reasons for its selection. Deflection indicators were installed below all the other OFFB vessels to enable a continuous monitoring of the integrity of all the remaining original bottoms. Fatigue failures of the remaining OFFBs are expected at random. Redesigning started on the distribution system after it failed in the vessel with the RFFB. It was decided to use a system similar to the one in operation at Afprod Glucose plant in Germiston, which had given no problems since installation. This system, THB, consists of a top hat, layers of graded stone above the top hat to form a stone bed and then the resin above the stone bed. The top hat installation forms the new collection point of the bottom distribution system. The stones form a filter that prevents the resin beads from escaping through the top hats. An additional strake was added to the bottom of the resin vessel to increase the height and volume, to compensate for the loss of resin volume created by the stone fill. A top hat installation with four top hats (Figure 5), was done on a spare RFFB before it was installed on one of the secondary vessels. An increase of the failure rate of the distribution system in the primary vessels with the CDEs prompted a redesign of the distribution system in the vessels with these bottoms. A single large top hat was installed at the bottom of the dished end (Figure 6). The height of the vessel was also increased to allow for the loss of resin volume created by the stone bed that was loaded above the top hat. The new stronger fabricated flat bottom has removed the structural risk of failure but at considerable expense. It was however the most cost effective solution at the time when the old fabricated bottom failed the statuary inspection. The installation of the top hat and stone bed distribution system has solved problems experienced with the lateral distribution system. In addition, it has reduced the pressure drop across the vessel. This has allowed a reduction in the feed pressure above the resin from 450 to 320 kag. No problems have been experienced on the new top hat and stone bed distribution system, which has worked well with the new fabricated bottom and has run now for a over a year without any maintenance being required. 499

Figure 5. Redesigned fabricated flat Bottom with four top hats installed (stones omitted for clarity). Figure 6. Torispherical dished end with a single top hat installed (stones omitted for clarity). Results and Conclusions Replacement of the original fabricated flat bottom with a dished end, fitted with a top hat and stone bed, has removed the structural risk while retaining the improved hydraulic characteristics. Less power is required to obtain the same flow rate through the vessel at the lower internal pressures. The torispherical dished ends are also cheaper than a redesigned fabricated flat bottom. Further, the top hat and stone bed does not require a flat bottom either fabricated or artificially created, which removes problems of setting concrete in a torispherical dished end and the higher cost of the redesigned fabricated flat bottom. The dished end, fitted with a top hat and stone bed, is now the preferred choice of bottom and distribution system at the Hulett Refinery. This installation runs under a lower pressure, which increases the safety factor on these vessels. The operation of these vessels under lower pressure requires less power and less compressed air for operation. The installation cost of this system is also less than that of the redesigned fabricated flat bottom. A program has therefore been put in place to change all vessels to a dished end bottom with a single top hat and stone bed as per Figure 6 over time or when failures occur. 500

AENDIX A Finite element analysis of original bottom and third party inspection A FEA was done on the original fabricated flat bottoms to determine the expected deflections under normal operating pressure and test pressure. This FEA indicated very high stresses in the shell and support beams, as high as 280 Ma, which exceed the allowable stress of 150 Ma for boiler plate (B1501-151-430A) up to a thickness of 40 mm and below a temperature of 100 C as specified in (B5500: 1999 pecification for fusion welded pressure vessels). These high stresses indicated that a redesign of the bottom would be required. Third party inspection of failed vessel Due to the complexity of the OFFB, assumptions had to be made to do the third party inspection, when it was legally required. The easiest way to inspect the integrity of such a bottom is to measure the deflection in the centre of the bottom during a pressure test. The L/600 rule for load bearing beams in the crane and rigging beam codes were used to determine the maximum deflection under operating load. A deflection of ±12mm was measured in the centre of the vessel that should have been less than 4.66mm for a span of 2800mm (the diameter of the vessel). This clearly indicated that the structural integrity of the vessel had reduced to below acceptable levels. The FEA A numerical model was generated using MC visual Nastran. This model was meshed, loaded with operating and test pressures, constrained and analysed. Figure A1 shows the calculated Von Mises stresses on the bottom when the operating pressure is applied, which is typical of all the plots obtained, during the analysis of the various options. The calculated deflections and maximum Von Mises stresses are shown in Table A1. Figure A1: Von Mises stresses in original fabricated flat bottom (operating pressure applied). Table A1: Calculated results from FEA. Applied pressure Calculated Maximum calculated Von Maximum allowable defection Mises tress design stress 454 kag (operating) 4.21 mm 279 Ma 150 Ma 681 kag (test) 6.32 mm 419 Ma 501

AENDIX B Finite element analysis of redesigned bottom and selection The fabricated bottom was redesigned using FEA. Different plate thicknesses and different support beams were used in a trial and error process until the calculated stresses reduced to below the maximum allowable stress. The stresses were reduced to below 148 Ma under operating pressure. This calculated value is below the allowable 150 Ma design stress as specified in the design code. The calculated deflections reduced to 2.47 mm and 3.71 mm under operating and test pressures respectively as shown in Table B1. Table B1. Calculated results form FEA. Applied pressure Calculated Maximum calculated Maximum allowable defection Von Mises stress design stress 454 kag (operating) 2.47 mm 148 Ma 150 Ma 681 kag (test) 3.71 mm 222 Ma election It was found, during the process of deciding on how to repair the OFFB, which failed the third party inspection, that torispherical Dished Ends (DE) had a delivery of 6-8 weeks at the time. Additional to this, a further 5-6 weeks would have been required to install the new DE, fill it with concrete, let it set for 21 days under vacuum and then coat the inside of the vessel and the top of the concrete with a protective coating, at this stage the top hat and stone bed solution had not been chosen. It was decided that due to these problems and the long down time, that the OFFB should be redesigned. This process of redesigning, fabrication and installation of the RFFB took about 8 weeks. 502