Screens. Menus Left Button Information Right Button

Similar documents
Shearwater GF Computer

VERSION

Introduction. The Shearwater Petrel is an advanced technical diving computer for open and closed circuit divers.

DIVECOMPUTER.EU USER MANUAL V3.0

OPERATING INSTRUCTION MANUAL. Powerful Simple Reliable

Version 44 ( ):

Operating Instructions

English. English. Predictive Multi Gas for

Standalone & EXT Models

Version 53 ( ):

Version 65 ( ):

idive Color New Armored with Multi-Transmitter Side Mount Mode RATIO idive Easy idive Deep idive Tech+ with Multi-Transmitter

Shearwater Pursuit Manual

Contact. For any questions relating to your OSTC sport please contact us via. internet forum: forum.heinrichsweikamp.com

Technical Diving Software for. User Manual

Dive computer, software version 2.52

Ver. 2 Displays And Electronics User Manual

TDC-3 user manual. by Technical Dive Computers Inc. Victoria BC Canada

User manual. hwos tech. OSTC dive computer with the Firmware OSTC 2 TR OSTC 2. OSTC cr. OSTC plus

Matrix Dive Computer. Instruction Manual

NAUI RGBM Dive Planner Windows Version Rev 9/2016

NiTek X Dive Computer User Guide

NiTek X Dive Computer User Guide


INCREDIBLY EASY EASILY INCREDIBLE

Date of Purchase

SAFETY CONSIDERATIONS

idive Easy User manual Ver 3.2

Electronic controller for Closed Circuit Rebreather USER S MANUAL. version 1.0

INCREDIBLY EASY. EASILY INCREDIBLE.

CHROMIS DIVING COMPUTER - DESIGNED BY DIVING ENGINEERS WARNING

NEWTON QUICK REFERENCE CARD

SUUNTO EON STEEL 1.6 USER GUIDE

OperatorsManual. Multi gas, multi mode decompression computer

Galileo 2 (G2) User Manual

Aladin Square User manual

VEO 4.0 OPERATING MANUAL VEO 4.0 DIVE COMPUTER OPERATING MANUAL. Doc. No r01 (3/20/19)

NAVY EOD III Low Magnetic Signature DIVE COMPUTER Operator's Manual

XP EINS USER MANUAL. Contents: 1.1XP EINS USER S MANUAL

SUUNTO EON CORE USER GUIDE

Suunto D-SerieS watch-sized Dive computers

Smart Dive Computer. Instruction Manual

GALILEO 2 CONSOLE (G2C) USER MANUAL

Aladin ONE (Matrix) User Manual

Color Dive Computer. Instruction Manual

A300 CS OPERATING MANUAL A300 CS DIVE COMPUTER OPERATING MANUAL

PROPLUS X OPERATING MANUAL PROPLUS X DIVE COMPUTER OPERATING MANUAL. Doc. No r01 (8/19/16)

ACI_Release_Notes.txt VERSION Fixed Tank info for ELITE in Dive section 2. Fixed USB port initializing for old DC VERSION

PRICE LIST 5 April 2018

Quad Air Dive Computer. Instruction Manual

DATAMASK HUD. Water or Push Button Modified Haldanean / DSAT (Diving Science and Technology) Database Each Level provides No.

idive Free User manual Ver 3.0

Color Dive Computer. Instruction Manual

Introduction This section includes suggestions on how to use this guide, an overview of course philosophy and goals.

Version 3.1.0: New Features/Improvements: Improved Bluetooth connection on Windows 10

HUDC User Manual Head Up Dive Computer Vers: 1.3 Mar. 2014

POSEIDON M28 USER MANUAL 1.2 fw version 1.8

Previous Release Notes

Aqua Lung International, Inc. (2016) Doc r03 (3/28/16)

Smart Dive Computer. Instruction Manual

Ratio Deco. Overview. Global Perspective

A300 CS OPERATING MANUAL A300 CS DIVE COMPUTER OPERATING MANUAL

Aladin TEC 3G User manual

Aladin TEC 2G. Deutsch English. Nederlands Español Italiano Français. User manual. Bedienungsanleitung. Manuel d utilisation.

SAFETY CONSIDERATIONS

ix3m ix3m Easy, ix3m Deep, ix3m Tech+, ix3m Reb User Manual ver [Pro] edition [GPS] edition

POSEIDON M28 USER MANUAL 1.4 OS version 2.1.7

Puck Pro Dive Computer. Instruction Manual

AV1 MANUAL. dive computer. (revision 8/2015)

Diving at Altitude. Part One: Starting with Residual Nitrogen. By John Adsit January 30, 2018

VR Series Dive Computer Manual

Aladin SPORT User manual

Galileo HUD pro User Manual

Veo 200/250 dive computers operating manual

Team Blue Immersion. TecRec Overview. Technical Instructor Course

Dive Computer. User s Guide

VR Series Dive Computer Manual

Introduction This section includes suggestions on how to use this guide, an overview of course philosophy and goals.

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

M2 DIVING COMPUTER - DESIGNED BY DIVING ENGINEERS

1. Unlimited, so long as adequate facility, supplies and time are provided to ensure comprehensive and complete training of subject matter

User Manual. Scuba Capsule Europe GmbH User Manual 1 of 17

8. TDI Trimix Diver Course

COSMIQ + Dive Computer User Manual. Firmware version 1.7. Deepblu, Inc. All rights reserved.

ALGE DIVE! ALGE. ALGE-TIMING GmbH & Co

Dive Computer NEMO SPORT

7. TDI Advanced Wreck Diver Course

XP-3G. English Deutsch Français Italiano Español Nederlands 日本語简体中文

PRO PLUS 2. dive computer. operating manual

Computers and Dive Tables. Revised September 17, 2017

New product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package

DIVER NAVIGATION BOARD. RJE International, Inc. RJE International Feb 1, TAC-100D Revision 10

Training. A Training and Education Update for PADI Members Europe

Introduction This section includes suggestions on how to use this guide, an overview of course philosophy and goals.

ENGLISH. uemis ZURICH. SDA Scuba Diver Assistant Quick Reference Guide

Instruction booklet Nemo

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Cochran COMMANDER EMC-20H With Helium Owner's Manual

Transcription:

Screens Menus Left Button Information Right Button

Modes 1{ OC Tec Air, Nitrox, Trimix 5 gas computer 3{ OC Rec Air, Nitrox 3 gas computer 2{ OC/CC OC/SC for Petrel 2 EXT Air, Nitrox, Trimix 5 gas computer 4{ Gauge Depth and time display As decompression tissues are not tracked in Gauge Mode, changing to/from Gauge Mode resets your deco

How is OC Rec Mode different? 3 gas Air & Nitrox Computer Has warnings appropriate for recreational divers: o MOD Warnings o Safety Stops can be configured for 3, 4, 5 mins or adaptive

Enter Gases There are 2 ways to enter gases: 1{ 2{ via System Setup Menu > OC Gases via Dive Setup Menu > Define Gas Define Gas - use to add, edit or change gases underwater.

Gases Always ordered from highest O2 content to lowest Always turn on only the gases you are carrying o Off gases are not used in deco calculations

Colour Usage Colour is used to display information and to draw attention to problems or unsafe situations o White: normal (Firmware v18 now allows for Green to be used) o Yellow: used for warnings that aren t immediately dangerous o Flashing Red - used for critical alerts

Colour Blind Warnings or critical states can be determined w/o colour o Warnings (Yellow) - solid inverted background o Critical Alerts (Flashing Red) - switches b/w the inverted and normal text

TTS Assume the user makes choices o Ascent rate of 30 /min o Uses gases that are turned on *If the diver does not do these things, the predictions are incorrect

@+5 The TTS if remaining at current depth for 5 more minutes

CEIL The current decompression ceiling (not rounded to the stop interval) o (i.e. not a multiple of 10ft/3m).

GF99 The Bu hlmann ZHL-16C super-saturation percent gradient Meant to give an intelligent way to judge your situation based on the current conditions. Manage deco aggressively.

When and Why? Limited gas Min BO get out of the water only Holy Poop Button

Gradient Factors You can change them in the Dive Setup Menu > Conserv You can edit the GF(Hi) during the dive Higher number = less conservative Lower number = more conservative

GF, cont d GF(Hi) & GF(Lo) GF(Lo) controls the first stop GF(Hi) controls the surfacing value

30/70 Current default setting Follow current scientific research o Neal Pollock s Extreme Exposure study which will be published 2015. Many factors including exercise, temp, age, gender, etc

VPM Optional algorithm for purchase (n/a in OC REC) How to order: o Send in the serial number of the unit you wish to have unlocked. o We issue the code and send it back via email. o This code will need to be input via the System Setup Menu -> System Setup Submenu -> Unlock 0 - +5 Conservatism Settings. Cost is $75 Retail

VPM & GF Once VPM is activated, can switch between Buhlmann, VPM, and VPM/GF in the System Setup Menu>Deco Setup submenu As with Gradient Factors the higher numbers are more conservative, therefore +5 is more conservative than 0.

Last Stop Can edit in System Setup Menu > Deco Setup Changes from 10-20 (3-6m) o Doesn t affect decompression o Only makes the TTS prediction more accurate o 20 stop less efficient when using Air Therefore, deco stops are longer than necessary

Customization: Center Row Display is customizable System Setup Menu > Center Row for OC TEC mode o The center position can only display PPO2. In OC only mode, the PPO2 display can optionally be turned off.

Customization: Bottom Row For OC REC mode the bottom row is editable. The bottom-left position always shows the currently selected gas.

Compass 1 resolution ±5 accuracy Smooth, high-speed refresh rate Heading with reciprocal True North (declination) adjustment Tilt compensation ±45

Marking a Heading: To mark a heading, press MENU (left) button until "Mark Compass" is displayed, then press SELECT (right) button to mark the current direction. The display will then jump back to the compass display. The heading is shown as a pair of green triangles. The reciprocal heading is in red.

Salinity Salt Fresh EN13319 This is the value for water that is between salt and fresh. o Is the Petrel s default value.

End Dive Delay Sets the time in seconds to wait after surfacing before ending the current dive o This value can be set from 20 seconds to 600 seconds (10 minutes) o Default is 60s Some instructors use a longer end dive delay when teaching courses. Alternatively, a shorter time can be used to exit dive mode more quickly upon surfacing

Setpoints Min/Max generate warnings OC MIN OC MAX o OC Deco o Only sets the limit at which PPO2 will flash red and generate a High PPO2 warning. This should be set slightly higher than the max PPO2 at which you plan to deco. The decompression predictions (TTS and NDL) will assume that the gas in use at a given depth is the gas with the highest PPO2 that is less than or equal to this value. Also, the suggested gas switches (when the current gas is displayed in yellow) are determined by this value. Deco tells when to switch gases

Battery Choice User Replaceable AA battery Remember to correctly set the type of battery being used this is done when the battery is changed or removed

Note About Alkaline Batteries: All Alkaline batteries can leak corrosive liquids. The risk is highest when completely discharged. o To avoid this risk, use another battery type such as lithium, or do not store for more than 2 months with alkaline batteries installed. Never leave discharged batteries in your Petrel.

Service? We have Service Centres in the following locations: US Contact Curt McNamee NZ Contact Paul Trainor UK Contact Narked @ 90 CAN Contact the factory direct If unsure, it s always best to email info@shearwater.com

Update firmware Download Dive Log Change Start-Up Text Bluetooth / Shearwater Desktop

Languages We have manuals and firmware in languages other than English. Manuals are currently in the following: o English, French, German, Italian, Japanese, Spanish, Polish, & Simplified Chinese Firmware is currently available in the following: o English, French, German, Japanese, & Simplified Chinese