Self-Inspection Explanation Sheet

Similar documents
Research Laboratory Safety Self-Inspection: Chemical & Physical Safety Checklists

Laboratory Inspection Checklist

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

LABORATORY SAFETY INSPECTION

Laboratory Safety Inspection Checklist

Laboratory Safety Training. Environmental Health and Safety

Biosafety Level 2 (BSL2) Laboratory Safety Inspection Checklist

Environmental: Hazardous Waste: Satellite Accumulation Areas (SAA)

BIOSAFETY SELF AUDIT PRINCIPAL INVESTIGATOR/PERMIT HOLDER: CONTAINMENT LEVEL: 1 2 (Shaded) RISK GROUP: 1 2 AUDIT TO BE COMPLETED BY (DATE):

EHS-SWP-140. Safe Work Practice. Animal Projects with Chemicals. 1.0 Hazard Description

Safe Operating Procedure

Operations: HSE. Health and Industrial Hygiene. Laboratory Safe Work Practice

Western Sydney University Safety Inspection Checklist - Laboratory Environments

TEMPLE UNIVERSITY A Commonwealth University Environmental Health & Radiation Safety (EHRS)

Risk Management Resources

MAFES Horticultural Facilities AREA-SPECIFIC SAFETY TRAINING GUIDANCE

Lab-Specific Standard Operating Procedure (LSOP)- Pyrophoric Chemicals

STANDARD OPERATING PROCEDURE (SOP): URETHANE

Safety Manual > Safety Checklist for Labs

Laboratory Self Inspection Checklist LAB01

Semi-annual BRD Checklist. Inspection Location(s) P.I. Name. Office Telephone : Contact Telephone : Department. Survey Date : Reviewed Date :

STANDARD OPERATING PROCEDURES (SOP) FOR REPRODUCTIVE HAZARDS

Chapter 4: Implementing Effective Exposure Controls

CUSTODIAL Safety Inspection Checklist

HAZCOMM & Lab Safety College of Dental Medicine Research Safety Specialist Environmental Health and Safety

OFFICE OF STATE HUMAN RESOURCES

Laboratory Safety Inspection Form. Building: Department: Room(s): Contact Person: Inspection Performed by: Organization:

Laboratory Personal Protective Equipment & Hazard Assessment Tool

Concordia University Laboratory/Workshop/Studio Inspection Checklist

MINIMUM SAFETY REGULATIONS

SHOP SAFETY INSPECTIONS

PURPOSE OF THE POLICY

Compressed Gases and Cryogens

07/09/2013 Listing of Inspection Categories The University of Texas at El Paso Point CHEM

Environmental Health and Public Safety. Graduate Student Safety Training

Hydrofluoric Acid SOP

HAZARDOUS WASTE OPERATIONS AND EMERGENCY RESPONSE PLAN Kenyon College

Environmental Health and Public Safety. Graduate Student Safety Training

TFS Safety Manual. Laboratory and Research Safety

Effective Date: 24-April-2017 Version: 6 Page: 1 of 8 TITLE: SAF-370, PERSONAL PROTECTIVE EQUIPMENT GUIDELINES. Table of Contents

LABORATORY HAZARD AWARENESS TRAINING

Standard Operating Procedure

Personal Protective Equipment

The primary purpose of laboratory fume hoods is to keep toxic or irritating vapors out of the general laboratory working area.

5.0 Store. safely IN THIS SECTION: 5.1 Decanting or transferring

Hazardous Materials Spill Response

WHMIS 1988 & WHMIS 2015

LABORATORY SAFETY. A general overview

Laboratory Standard Operating Procedure: Specimen Preservatives

CHEMISTRY FACULTY LABORATORY SAFETY CONTRACT CENTRAL CAMPUS

Hydrofluoric Acid. Syracuse University Laboratory Standard Operating Procedure. I. Purpose: Physical and Chemical Properties: Potential Hazards:

Instructions for Completing the UW-Madison Laboratory Chemical Hygiene Plan Template

Hazardous Materials Spill Response

Material Handling and Storage of compressed gases and Air equipment

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

1. Substance Information

Town of Brunswick. Hazard Communication and Global Harmonization System (GHS) Plan

Hazard Communication Program

Compressed Gas Cylinders - Guideline

e-compliance Training

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Laboratory Standard Operating Procedure: Irritants

To fill out this checklist online from a tablet or phone, please use the SIT tool on UC Safety Suite. Principal Investigator/Laboratory Supervisor:

CCM Approval: IACUC Approval:

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

General Precautions for handling compressed gases

Laboratory Standard Operating Procedure: Cryogenic Liquids

Laboratory Standard Operating Procedure: Carcinogens

BBE Laboratory Safety Training. Department of Bioproducts and Biosystems Engineering Presented by: Luke Stolp September 2016

WEBINARS. Hazard Communication

Purpose Written Program Hazard Classifications (GHS) SDS Sheets (GHS) Labels (GHS) Employee Training Chemical Safety Questions

UNH Department of Forensic Sciences

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

Post MD in Residence Placement

Hazard Communication Plan (HCP) 29 CFR

EHS Workplace Inspection Checklist (Ref. SOP QMS-080; EHS-010)

Safety Rules for the Science Lab

OKLAHOMA CITY COMMUNITY COLLEGE PERSONAL PROTECTIVE EQUIPMENT PROGRAM. Environmental Health and Safety

CHECKLIST FOR LABORATORY BASED INSPECTIONS

Laboratory Standard Operating Procedure: Reproductive Toxins

The health hazards of HF are dependent upon the concentration, temperature and nature of exposure.

Developing Safety Guidelines for Cryogenic Liquids.

Collision Repair Shop Inspection Checklist

NRES Procedures for Lab-based Projects and Research

Laboratory Safety Coordinator Meeting

Hazard Communication Program

General: This procedure addresses general safety & health requirements for work in the laboratory.

Instructions for completing the Unit Operations Lab safety inspections using the Safety Inspection Checklist

"SAFETY HOUSEKEEPING AND ACCIDENT PREVENTION"

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre

CHAPTER 26 WELDING AND CUTTING

Laboratory Safety Manual December 2016

HAZARD COMMUNICATION & THE GLOBAL HARMONIZING SYSTEM EMPLOYEE TRAINING. Leader s Guide. ERI Safety Videos

Safety Issues in Healthcare Programs / Healthcare Employment

LABORATORY FUME HOOD SPECIFICATION AND MAINTENANCE PROGRAM

Transcription:

Self-Inspection Explanation Sheet Inspection Program Guidance Document General Self-inspection It is good practice for staff in laboratories and research areas to use the self-inspection checklist to go through their laboratories and research areas and conduct their own laboratory/research area inspections identifying the same topics covered during the Laboratory and Research Area Inspection conducted by the Department of Environmental Health and Safety. Injury and illness reporting All accidents and exposures to harmful chemicals, no matter how minor, need to be reported to the supervisor and the injury/illness/exposure report needs to be filled out online. https://rmps-prod.hosting.cornell.edu/accinj Research Laboratory Chemical Hygiene Plan A Chemical Hygiene Plan (CHP) for laboratories is required by OSHA. It must be accessible in all labs either electronically or as a hard copy. SDS OHSA regulations require that employees have access to Safety Data Sheets (SDS), electronically or hardcopy or both) within five (5) minutes. In addition, emergency responders may need a hard copy of an SDS. HASP/Door signage The Hazard Assessment Signage Program (HASP) requires that each room have a hazard identification sign on the door indicating the primary hazards present in the room. HASP signs need to be updated annually. Research Hazard Communication Areas Policy Each non-laboratory space is required to have access to the Hazard Communication Program. Training OSHA also requires training on the Hazard Communication Program. Nonlaboratory personnel should take Hazard Communication training provided by EH&S. The Laboratory Safety class also meets these requirements. Chemical Inventory - An inventory of all hazardous chemicals should be maintained. Labeling All containers that are not empty must be labeled with their contents and must be marked with the right-to-know information for any hazardous chemicals present. The original manufacturer s label is fine, but if the chemical is transferred to a non-original container, it must have a secondary label that must include the chemical name, a harmonized signal word, GHS pictogram, hazard statement for each hazard class/category, a precautionary statement, and supplier identification. Revision date: 6/24/16 Page 1 of 10 The most recent version of this document is available electronically at web at:

Chemical Safety Labeling For safety reasons as well as EPA and OSHA regulations, every container that appears to have a chemical in it must be labeled and easily identified by every user within the lab. Some common labeling methods are original manufacturer labels, secondary labels that must include the chemical name, a harmonized signal word, GHS pictogram, hazard statement for each hazard class/category, a precautionary statement, and supplier identification. If abbreviations are more practical, use a list or key to the abbreviations. Container Integrity Containers in bad condition run the risk of being cited by EPA as inherently waste-like. Containers should be in good condition, with no leaks or spills, no broken caps, and no rusty cans. Abbreviation Key - The key must contain the abbreviation and the name of the chemical. Including the hazards of the chemical on the key is also useful information. A sample fill-in-the-blank key can be found on the EH&S website. The abbreviation key must be readily available upon request by visitors, emergency responders, state and federal regulatory agencies such as EPA, OSHA, or NYS OFPC inspectors. SOPs Standard Operating Procedures (SOP) - Each lab is required to develop safe handling instructions for their highly hazardous, highly toxic, and carcinogenic chemicals. If a format is needed see: https://sp.ehs.cornell.edu/lab-researchsafety/laboratory-safety-manual/pages/appendix-d.aspx Segregation Chemicals must be segregated, by the hazards they present, to avoid incompatible materials being stored together. Storing chemicals by hazard class in different cabinets or in different secondary containment is recommended. Secondary Containment - Use trays or bins, to conduct your experiment in and for storage of particularly hazardous substances and hazardous waste containers. Flammables in Flammable-rated Cabinet Larger volumes of flammable liquids must be stored in a flammable rated cabinet. As a general guide, we recommend that rooms with more than 10 gallons of flammable liquids use a flammable rated storage cabinet. Flammables in Flammable-rated Refrigerator Flammable liquids (flashpoint below 100 F) should not be stored in regular refrigerators because of the risk of explosion (this includes walk-in units). Flammable liquids may be stored in flammable or explosion rated refrigerators. Using an ice bath to cool chemicals before an experiment might be an option for some laboratories. Overhead or Floor Storage Hazardous chemicals should be not stored above eye level or on the floor. Heavy equipment and heavy boxes should not be stored overhead. Surplus Chemicals Some surplus chemicals may be able to be used by others in your department. Contact your Department Safety Representative to send out the list. If the chemicals cannot be used, they should be disposed of properly. Page 2 of 10

Specific Chemicals Perchloric Acid Heating perchloric acid requires a specific fume hood with a wash down system. When working with Perchloric acid, be sure to remove all organic materials, such as solvents, from the immediate work area. Ethidium Bromide (EtBr) The areas where EtBr is used should be labeled and require special deactivation process. Hydrofluoric Acid (HF) The areas where HF is used needs to be clearly labeled. Calcium gluconate is required to be available for first aid treatment in case of accidental exposure. HF Training is required for all that use HF. Cryogenic Liquids Cryogenics are extremely cold and their vapors pose an asphyxiation hazard. Dispensing and storage areas need to be well ventilated. Silver Groups that develop film or use silver nitrate in staining solutions should know where a silver filtering unit is, and how to use it. For information please contact EH&S at 607-255-8200. Peroxide Formers - Peroxide forming chemical containers should be dated on the container when they are received and opened. They also need to be checked regularly with peroxide test strips with the results noted on the container. The regularity at which chemicals need to be tested for peroxides can be found in the Chemical Hygiene Plan. If peroxides begin to form, the material must be treated to remove peroxides, or disposed of properly. Security for Highly Hazardous Materials Laboratories need to take specific actions in order to provide security against theft of highly hazardous materials. Examples include using locked cabinets, locked drawers, and lock boxes, in addition to keeping laboratory doors locked when the room is unoccupied. Compressed Gases Secured - Cylinders must be secured to a sturdy object to prevent toppling. A chain (preferred) or strap should be tight enough and strong enough to secure the cylinder. Placement of strap should be in the upper 1/2 of the cylinder but not around the cap or valve. A cylinder chained on a cylinder cart is acceptable, but not as safe as if it were chained to an immobile object. Cap/Regulator Cylinders that are in use must have a regulator attached. Cylinders that are not hooked up to equipment or considered in use must be capped with a valve protection cap. Cylinders must be capped during transport. Hang Tags Cylinders should be tagged with: Full, In-use, or Empty tags. Gas vendors are usually willing to provide tags at no charge to customers. Page 3 of 10

Segregation/Storage Flammable gases and oxidizing gases must be separated by an acceptable fire barrier. This separation could be a fire rated wall or a minimum 20 feet space between the types of cylinders. Flammable gases or oxygen should not be stored near a source of ignition such as electrical panels or open flames. EPA Compliance Labeling Hazardous waste is required to be labeled with the words Hazardous Waste and the contents and hazards. Use the EH&S hazardous waste label. (Tip Sheet) Closed Hazardous waste containers must to be kept closed with a tight sealing lid. For containers hooked up to equipment, bottles still need to be closed using when not in process. Special caps can be procured where the bottle remains closed while tubing is connected to equipment. Point of Generation Hazardous Waste must be stored in the area where it was generated. We have interpreted this to mean in the same room. Secondary Containment As stated in CFR 267.195, the following are the requirements for a secondary containment system used to prevent the release of hazardous waste. A secondary containment system must be constructed with or lined with materials that are compatible with the wastes placed in the tank and must have sufficient strength to prevent failure. This system must be placed on a foundation/base capable of supporting it. The secondary containment system must also have a leak detection system such that the failure of the primary or secondary containment structure or the presence of the release of hazardous waste can be detected within 24 hours. The system must also be sloped or designed or operated to drain and remove liquids from leaks within 24 hours. Accumulation of Excess Waste Large quantities of stored hazardous waste should be removed to prevent accidental spills. Old, inherently Waste-like Containers Degraded containers can release hazardous vapors that are detrimental to the health of laboratory personnel and allow chemicals to become contaminated, which can have an adverse effect on experiments. Universal wastes - Universal wastes include batteries and fluorescent light bulbs. Universal Wastes require the labeling: Universal Waste - Bulbs or Universal Waste - Batteries. Universal Waste must be labeled with an accumulation start date and must be disposed of within the year of the start date. We recommend that universal wastes be disposed of every 9 months to give the solid waste group time to process it. Oil Containers of used oil should be labeled Used Oil, kept closed and be placed in secondary containment. Check with the building manager for the location of the used oil drum in your building. If you suspect that oil has become contaminated with a Page 4 of 10

hazardous chemical such as Freon or PCBs (maybe from a transformer or old refrigerator), please call EH&S at 607-255-8200 before discarding or mixing with other oil. Fume Hoods Tested Fume hoods are tested annually by Cornell s HVAC shop in a program that is overseen by EH&S. Items in Hood Blocking Flow - Keep all materials from blocking vents or baffles in the back of the hood by elevating materials at least one inch off the work surface. Bench Cabinet The cabinet where chemicals are stored should be good condition. If the interior is degraded, the cabinet should be replaced. PPE PPE Assessment - Personal Protective Equipment (PPE) is the equipment necessary for you to protect yourself while performing your job. The assessment determines the type of PPE is needed, when it is appropriate, and the limitations of the PPE. The PPE includes the following (but is not limited to): respirators, eyewear, gloves, clothing, hearing protection, and foot protection. Use of Respirator - The use of all types of respiratory protection at Cornell is governed by the OSHA standards and the Cornell EH&S Respiratory Protection Program. A laboratory worker at Cornell may not purchase a respirator and bring it to their lab for personal use without prior consultation with EH&S. Electrical Safety Electrical panels The area in front (minimum of 3 feet) is required to be free of material, to allow access. The circuit breakers need to be labeled appropriately to what each circuit breaker controls and the breaker panel needs to be intact; all openings must be covered with appropriate material. Extension Cord/Power strip Equipment should be grounded or double insulated and be tested by a third party such as Underwriters Laboratories (UL approved). You must not use equipment that has a worn or frayed cord. Extension cords are allowed only for temporary use on portable power equipment. A power strip cannot be plugged into another power strip or have extension cords plugged in to it. Inspect the cord prior to use for any deficiencies if any are found, the cord needs to be replaced. GFCI When working with electrical equipment around wet and/or damp environments, a Ground Fault Circuit Interrupter is required to be used. Temporary GFCI plug adapters can also be used, but are not a substitute for GFCI outlets or circuit breakers. Page 5 of 10

Lab Equipment Safety Equipment Labeled for use Refrigerators, freezers, microwaves, and dishwashers need to be labeled: Chemical/sample storage Only, Research Use Only, Food Only No Chemicals, or other appropriate labels. Refrigerant/Ozone Depleting All equipment that uses refrigerant or Ozone depleting substances should have an EH&S Environmental Compliance inventory sticker. Rotovaporators Due to vacuum pressure upon the glass there is increased risk of implosion hazard. The glass should be wrapped in a protective coating, for example with a plastic mesh sleeve or with clear packing tape if they do not contain a protective coating. Mercury-containing Equipment Equipment that contains mercury is recommended to be changed out with like equipment that does not contain mercury. If not applicable, then the equipment should be labeled with a sticker Contains Mercury and an appropriate mercury spill clean-up kit should be available. Sonicators Hearing protection is recommended to be available and worn when using this equipment, to protect against hearing loss. Battery Recharging Station Requirements for lead/acid battery charging stations: plumbed eyewash station, PPE (gloves, apron, goggles and face shield), fire extinguisher, good ventilation, and no sources of ignition. Equipment in Working Order Equipment that is use needs to be functioning according to manufactures specifications. If the equipment is not functioning properly it should be tagged and taken out of service until repaired. Machine Guarding - All moving parts on equipment must be properly guarded. Ladder Safety Ladders need to be functioning properly and sized appropriately for the application. Emergency Preparedness Emergency Action Guide This is a guide covering various emergencies that may occur and how to respond if they were to occur. Spill Kit - A well prepared spill kit will help manage small spills quickly and safely. Check the EH&S Webpage for recommended materials for spill kits. The rule of thumb for safety on spill cleanup is: If you don t feel comfortable doing it, or you don t have the necessary materials, evacuate the area and use the facility emergency phone or 911 for help. Page 6 of 10

Housekeeping Aisle Space - Fire code requires a minimum 36 aisle space. Spaces between work benches should not be cluttered with storage of materials and/or equipment. Eat/Drinking - It is possible for the food or drink to absorb chemical vapors and thus lead to a chemical exposure when the food or drink is consumed. Eating or drinking in areas exposed to toxic materials is prohibited by the OSHA Sanitation standard, 29 CFR 1910.141(g)(2). Work Space/Fume Hood Cluttered and messy workspaces can lead to safety issues and can attract attention when regulators inspect the area. Workspaces should be kept orderly and all chemical spills must be cleaned up. Chemical Spills Cleaned Up - Ensure all spills have been cleaned up and all potentially contaminated surfaces have been thoroughly cleaned with water and detergent. Lighting Work areas should always have adequate lighting to work safely. Slips/trips/fall Hazards Floors should be kept clean and free from debris and electrical cords. Chemicals and hazardous materials should not be stored in floor spaces. BioSafety Hypodermic Needles A certificate of need from the Department of Health is required to possess hypodermic needles and syringes. This is obtained either by the department or PI. Stocks of hypodermic needles must be kept in locked storage with an inventory system (log of use) that is kept for three years. Work with Biohazards, Infectious Material, Recombinant DNA The Cornell University Institutional Bio-Safety Committee issues a Memorandum of Understanding to investigators to assure appropriate health and safety measures are in place and to comply with existing government regulations and applicable University policies. Regulated Medical Waste Waste generated at BioSafety Levels 2 and 3 is defined as that generated in the diagnosis, treatment or immunization of human beings or animals, in research pertaining thereto, or in production and testing of biologicals. Additionally, regulated medical waste cannot contain any hazardous chemical or radioactive waste components. The biological component must first be decontaminated, and then treated as chemical or radioactive waste. Sharps Disposal - Hypodermic needles must always be discarded in a red sharps container. Hypodermic Needles should never be removed from a syringe; instead the entire unit should be put into a sharps container. Other sharps such as razor blades can be collected in sturdy puncture resistant container, taped shut and disposed of directly into the dumpster. Page 7 of 10

Exposure Control Plan OSHA requires that an employer implement the plan when employees are working with bloodborne pathogens. Research groups may need to add additional information relevant to their particular site in order to have an effective and comprehensive plan. BioSafety Cabinet - BioSafety Cabinets (BSC) need to be inspected and certified for use annually. BSCs should only be used for the work for which they were designed. Most BioSafety Cabinets (BSC) are not designed for chemical use. Alcohol for disinfection should have only limited use in BSCs. Radiation All radioactive materials must be acquired, possessed, and used at Cornell University facilities following the procedures described in this manual. This includes exempt quantities of radioactivity. All radioactive materials must be in compliance with the requirements of the U.S. Nuclear Regulatory Commission, the New York State Department of Health, and the New York State Department of Environmental Conservation. If you are working with radiation sources in your laboratory, make sure you contact Environmental Health & Safety to ensure legal compliance. Pesticides Federal law requires personnel to have Worker Protection Standard training prior to or within 5 days of working with pesticide treated plants. Contact: Eric Harrington; CALS OEH 5-0485; eh22@cornell.edu Federal and state law, as well as the University Health & Safety Policy 2.4, require lab personnel to be certified commercial pesticide applicators, technicians, or apprentices if working with amounts greater than very small lab scale. Contact: Eric Harrington; CALS OEH 5-0485; eh22@cornell.edu Shipping Hazardous Materials If the group ships hazardous materials, they should have a plan on how to do this correctly, using trained and qualified people. EH&S provides training for compliance with the Department of Transportation s regulations governing shipping of hazardous materials. Training Every person who handles Hazardous Waste must know what their role is in making sure that the waste is handled properly. EH&S provides a Chemical Waste Disposal class that covers these requirements. Page 8 of 10

Animal Areas Facility Manager The facility manager s information is required to be posted such that it is easily accessible to those entering these animal areas. AUHSP Paperwork Posted at Entrance The required postings are the animal health and safety brochure and allergy prevention fact sheet. These can be picked up at the CARE front office, if needed. Waste Anesthetic Gas (WAG) Procedure rooms or areas that use WAGs need to be reviewed by EH&S and if procedures have changed since the last review, a new review should be conducted. Training is required when working with WAGs. Record of Machine Maintenance - CARE requires that all anesthetic gas machines are certified annually. The certification date should be located on the equipment and CARE will keep a record of this as well. Control Measures for Allergens People who work with and around animals need to review and understand the information found in the Animal Users Health and Safety Brochure entitled "Allergy Prevention". SOP for Cage Transport CARE requires a standard operating procedure (SOP) be written for animal cage transporting. Escape Bars in Wash Areas Walk-in cage washing units need interior escape bars for personnel to effectively exit the cage washer unit. Hearing Protection Hearing protection devices should be provided before entering areas of loud noise areas. Eyewash/Safety Shower Corrosive Chemical Use An efficient functioning eyewash station is required to be readily accessible, free of obstructions and within 10 seconds from the hazard. The ANSI standard also outlines specific requirements related to flow requirements, use of tempered water, inspection and testing frequencies, and training of laboratory personnel in the proper use of this important piece of emergency equipment. Weekly/Annual Testing Laboratory personnel should flush the eyewash on a weekly basis, and post a test sheet for logging who and when the flushing occurred. Eyewash Test Sheet EH&S tests the eyewashes annually and tags them appropriately. Eyewash/Safety shower labeled A sign(s) denoting the location of the eyewash/safety shower should be posted. Page 9 of 10

Fire Safety Fire Extinguisher All workers must have immediate access to a fire extinguisher (within 75 feet). The extinguisher needs to have a current inspection, and needs to be appropriate for the fire risks present. Personnel should frequently check the pressure gauge to make sure that their extinguisher is still properly charged. The fire extinguisher should be secured to a wall. Combustible Storage Combustibles (materials that burn easily) must not be stored within 2 feet of the ceiling in a non-sprinklered room or, if the room is sprinklered, both combustibles and non-combustibles must be kept 18 inches below the level of the sprinkler head. Combustible materials should not be stored near sources of ignition including electrical panels, sparking equipment, and open flames. Excess Combustible Storage Large amounts of combustible material (paper, plastic, cardboard, etc) that is being stored within an area should be removed or recycled, due to the fire hazard the material presents. Potential Fire Hazards Special consideration about surrounding material needs to be taken when using equipment that produces an open flame, high heat, or electrical spark. Page 10 of 10