Vet-Temp Ear Thermometer Frequently Asked Questions

Similar documents
Digital Ear Thermometer

Infrared Ear and Head Thermometer Instruction Manual

Infrared Thermometer Instruction manual

GentleTemp 510. Digital Ear Thermometer

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

WATCH COLLECTION NG701 SERIES INSTRUCTION MANUAL

DPC-30 DPC-100. Reference Manual

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

HUNTER Beeper Collar Manual

Ambient Weather GL150-TH Nautical Thermometer Hygrometer (ComfortMeter) User Manual

ETE-68B4. Infra-red Ear Thermometer

TEMPERATURE, PULSE, RESPIRATIONS. Abbreviated: TPR

testo Leakage detector for refrigerants Instruction manual

Method of measuring bodytemperature. Temperature: Body temperature is the degree of heat maintained by the body. Heat is lost

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

Objectives: Assisting with Medication, Checking vital Signs

Department of Laboratories St. Louis, MO ISSUE DATE: June 2007 REVISION DATE: July 2010 REVIEWED DATE: May 2017 PRINCIPILE:

Ambient Weather WS-03 Thermo-Hygrometer

HemoCue Hb Procedure Template

with O 2 Controller Instruction Manual

Operation Manual Guillotine Cutter RC-5

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

USER S GUIDE DepthTrax 1H HawkEye Portable Depth Finder (DT1H)

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Pedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX

Met One E-BAM Particulate Monitor

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

USER MANUAL

Operating Instructions Part No

Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Digiquartz Water-Balanced Pressure Sensors for AUV, ROV, and other Moving Underwater Applications

Transferpette -8/-12

U S ER S AN D M AI N TEN AN CE M AN U AL

Napa Technology Trouble Shooting. For Premier & Premier PLUS Models

Manufactured by: AAA

TC65M/15M TEMPERATURE CALIBRATOR USER S MANUAL

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

MA PHIT- Food Certificate Program

DTG - LCD Digital Temperature Gauge USER MANUAL

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

User s Manual. USB Golf Simulator. Contents

Pipettor. User Manual

BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

Ambient Weather TIDECLOCK-25 6" Nautical Brass Quartz Time and Tide Clock with Bayonet User Manual

AXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)

Measurements. Metric System

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

WIKA INSTRUMENT CORPORATION

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

HI 2314 HI 2315 HI 23151

Prepared By: Lisa McAvoy 28/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

! Warning, refer to accompanying documents.

American Red Cross Rapid Read Underarm Thermometer Manual

USER MANUAL LTH-255A Hand Piece

O3 3E 1 F Gas Sensor Module

RayPette Plus Autoclavable Pipette. User Manual

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

BASIC LABORATORY TECHNIQUES (Revised )

NEULOG OXYGEN LOGGER SENSOR GUIDE

Operator s Manual 701 Test Kit for Static Control Surfaces (Megohmmeter)

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

Thank you for choosing Xuma.

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Bassett Medical Center Transfusion Services

The pipettes cover a volume range from 0.1µl to 10ml.

Exeter Clinical and Health Research


GasLab SAN-102 Micro Oxygen Monitor User Manual

P06 & P012 Pitot-Static Probes

Owner s Manual Humiport 10/20

Laboratory practice. Preparation and use of an ice point bath as a reference temperature. Document number TE-LP-001. Version: 07

BASIC LABORATORY TECHNIQUES (Revised )

DEEPSEA. LED Micro SeaCam POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

P8 to P60 Pitot-Static Probes

WARNING: EXPLOSION HAZARD

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Cover Page for Lab Report Group Portion. Pump Performance

SPECIFICATIONS APCEPH1

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

CHM Introductory Laboratory Experiment (r17sd) 1/13

Overview IMPEM163S. Carry out preventative planned maintenance on instrumentation and control equipment used in food and drink operations

SecureLift Lifting System Use Guide Nemisys

Air-Mate High Efficiency Powered Air Purifying Respirator (PAPR) Staff Training Module

1.0 General Guide WARNING!

AND OPERATION INSTRUCTIONS

PointsPlus U S E R G U I D E

Digital Melting Point Apparatus

Transcription:

1) What is the price of the Vet-Temp? Vet-Temp Ear Thermometer Frequently Asked Questions The Vet-Temp thermometer (VT-150) is $259.00 and a case of the disposable probe covers (DPC- 500) is $64.00. The probe cover dispenser (DSP-1) is included at no charge. This product is made for "professional" daily usage and has an expected lifetime of four to five years. Advanced Monitors Corporation will occasionally have promotional pricing available, please call 877-838- 8367 x105 for the latest details. 2) Is the Vet-Temp accurate? Yes, the Vet-Temp has a laboratory (in vitro) accuracy of 0.2 C (0.3 F). Clinical studies have verified the accuracy of the Vet-Temp. A recent clinical study conducted at the University of Missouri, Columbia and published in JAVMA concluded Our results revealed that the animal ear thermometer yields an accurate assessment of body temperature (JAVMA, Vol. 221, No. 3, August 1, 2002). Another clinical study at the San Diego Humane Society has verified in vivo accuracy on dogs and cats (right ear to glass rectal SD=0.68 F, left ear to glass rectal SD=0.59 F). When comparing ear temperatures of the Vet-Temp with rectal temperatures taken with either a glass or digital electronic thermometer, the Vet-Temp will typically read in the same range and will trend in the same direction. For clinical purposes, when used correctly, the Vet-Temp gives readings that are similar to rectal measurements, however, the Vet-Temp will not be perfectly equal to rectal temperatures for the following reasons: A. Rectal temperatures are different from core temperatures. Studies on animals and humans have shown that the rectum is not a perfect indicator of core body temperature. It is believed that this is due to the distance of the rectum from the core areas of the body along with the bacterial action inside the intestines and rectum. If the core body temperature is stable, the Vet-Temp and the rectal readings will typically be similar. If the core body temperature is not stable, there may be some variance between the Vet- Temp and the rectal readings. In these situations, the Vet-Temp will be more accurate than the rectal temperature because the Vet-Temp measure core body temperature changes immediately and the rectum does not. B. Accuracy of rectal temperature measurements with a glass or digital electronic thermometer depends on a number of factors including: How long the thermometer is in the rectum. The type and calibration of the thermometer. In checking new digital and glass thermometers at in an extremely accurate water bath reference, these rectal thermometers typically are miscalibrated anywhere from 0.2 to 1.0 degree Fahrenheit.

The success in having the measurement bulb of the thermometer to stay in contact with the rectal tissue. o If there is air in the animal's bowels, the thermometer may not make good contact with the tissue and this can lead to low readings. This lack of contact will also occur on anesthetized animals because of relaxation of the sphincter. Even with the normal variances between ear and rectal, the Vet-Temp gives the clinician an accurate indication of the animal's temperature range: hypothermic, normothermic or hyperthermic. To get an accurate reading on animals, the user must first pull the ear (pinna) out and down while inserting the probe as deep as possible in the ear and pointing the probe tip towards the angle of the opposite jaw (below the opposite ear and slightly forward). This technique will give the temperature of the deep horizontal canal, which is an accurate indicator of core temperature. If the probe is pointed towards the wall of the vertical canal, the reading may be low. It will take practice to become familiar with the correct technique. 3) What is the difference between the Vet-Temp and the human ear thermometers sold over the counter for home use? The Vet-Temp has been designed exclusively for animal temperature measurement. The two main design features, an extended sensor arm and a reduced probe tip diameter, allow the sensor probe to be positioned at the animal's horizontal ear canal for accurate readings. Human ear thermometers were designed specifically for human ear anatomy, which is different than that of most animals. The Vet-Temp has also been designed for high volume professional use such as that found in a busy animal health care facility. The over-the-counter human ear thermometers are intended for very limited (occasional) use found in a home environment. With battery replacement (every 3-5 years) the Vet-Temp should last for over 100,000 temperatures. The expected lifetime of a typical human consumer ear thermometer is only a few thousand temperatures - not nearly enough for a busy veterinary practice. 4) What is the difference between the professional model Vet-Temp and the consumer model Pet-Temp? The Vet-Temp is manufactured for high-volume usage in a professional environment whereas the Pet-Temp is manufactured for low-volume usage in a home setting. In a professional environment with rigorous daily usage, the Vet-Temp is expected to last several years whereas the Pet-Temp is expected to last only several months. Both models have the same accuracy. 5) On What size animals will it work? Clinical data validates that the Vet-Temp works effectively on dogs and cats of all sizes. It has been used on kittens as small as 4 weeks and on large dogs that weigh 150 pounds. It is routinely used

on many exotic animals such as ferrets, rabbits, chinchillas and guinea pigs. It is not recommended for full grown horses or cows. 6) Do I have to point the Vet-Temp at the tympanic membrane to get an accurate temperature (or from what part of the ear does the Vet-Temp take the temperature)? The Vet-Temp does not have to be pointed exactly towards the tympanic membrane; however it should be pointed down the horizontal canal and in the general direction of the tympanic membrane. We recommend an "ear tug" (as in standard otoscope technique), to align the vertical canal with the horizontal canal. The Vet-Temp should be seated as deep as possible (it should be snug) while pointing towards the angle of the opposite jaw. It will take practice to become familiar with the correct technique. 7) Why use the tympanic membrane or eardrum as a measuring site? The tympanic membrane region shares the blood supply of the brain. For this reason, it gives a brain blood temperature and is more accurate than a rectal temperature. Because the rectum is not located near the brain and due to naturally occurring digestive processes that generate heat, the temperature of the rectum may not be a good indicator of "brain blood" temperature. In a paper titled Brain, Blood and Rectal Temperature During Whole Body Cooling, James P. Kiley concluded that "rectal temperature cannot be used as an accurate measure of brain or arterial blood temperature." 8) Will ear wax affect the reading? For most cases, when the amount of cerumen is moderate, no. Earwax will be warmed up to the same temperature as the ear canal and will not cause inaccurate readings. If the ear debris (exudate) is excessive and the sensor has to be inserted through this material to be properly positioned, then the Vet-Temp reading will likely not reflect an accurate core temperature. It is recommended that the ear be cleaned and the temperature be retaken after a five minute wait. 9) How will an ear infection affect the readings? In the clinical study that was published in JAVMA that is referenced above, ear infections had no affect on the ear temperature. However, if an animal has a severe ear infection, using the Vet- Temp may be contraindicated due to sensitivity of the ear canal. Advanced Monitors recommends that when an animal has an injured or infected ear, the clinician should take the temperature from the other ear. If both ears are infected and sensitive, the clinician may have to resort to a traditional rectal temperature. 10) Over what ambient temperature range will the Vet-Temp work? The room or outside air temperature range of the Vet-Temp is from 50 to 104 F (10 to 40 Celsius). However the thermometer must be given sufficient time to equalize to the new ambient temperature if moved from a hot to cold environment or vice versa.

11) What is the patient temperature range? The patient temperature range is 93 to 108 F (34 to 42.2 C). 12) How long does it take for the Vet-Temp to register a temperature? One second. 13) How do I know when the Vet-Temp is finished taking a temperature? A short audible beep indicates the completion of the measurement. 14) What type of maintenance is required? The Vet-Temp and the optical window should be kept clean and dry. The Vet-Temp thermometer body can be cleaned with a soft cloth dampened with soap and water and/or alcohol. The optical probe window should be cleaned everyday, or when soiled, with alcohol and a cotton swab. After cleaning the optical window, the user should wait at least five minutes after cleaning and drying the optical window before taking a temperature. 15) Can the Vet-Temp register temperature in Fahrenheit and Celsius? Yes, there is a switch that will change between Fahrenheit and Celsius. To change from F to C or vice versa, push the C/F switch found next to the LCD with the end of a paper clip. 16) Do I need to use a probe cover? Absolutely! The Vet-Temp's calibration is based on having a probe cover installed. Failure to use a cover will lead to inaccurate readings. The probe cover is also designed to keep the probe optical window free from dirt and ear wax. If the Vet-Temp probe is inserted in the ear without a probe cover the optical window can also become damaged. Also, the probe cover prevents the transmission of infection from one animal to another. 17) Do I need to use a new probe cover every time? Absolutely! Re-using a probe cover will lead to low temperature readings. This is because earwax will solidify on the cover and block the heat waves, which will cause a low infrared signal. Also, reusing a previously used probe cover may result in transmitting an infectious agent from one animal to another. 18) How long will the built-in battery last? The life span of the battery is over 20,000 temperatures, with a shelf life of up to 10 years. If the Vet-Temp were used 20 times a day, 6 days per week, the battery would last approximately 4 years. Although, more extensive thermometer usage may somewhat shorten the life of the battery.

19) How do we replace the battery after it has lost its efficacy? For battery replacement, The Vet-Temp must be returned to. When out of warranty, the charge to replace the battery is $109.00. This charge will include any other repairs, reconditioning and recalibration that the instrument may require. Advanced Monitors Corporation will either replace the battery or replace the thermometer with a comparable device at the Company's discretion. 20) What is the warranty of the Vet-Temp? The Vet-Temp thermometer has a limited warranty for one year from the date of purchase. During the warranty period, will either replace the battery or replace the thermometer with a comparable device at the Company's discretion. 21) What is the policy for warranty repair returns? If a Vet-Temp is within the warranty period, it will be repaired or replaced at no charge at Advanced Monitors discretion. For a warranty repair, the user must contact Advanced Monitors Corporation's Customer Service toll free at 877-838-8367 x102 to receive a Return Material Authorization (RMA) number. Once the RMA is issued, this number should be written on the outside of the shipping case and then the thermometer should be sent back to Advanced Monitors Corporation. This assures prompt repair and return shipment.