SEIKO MULTI TIMING SYSTEMS

Similar documents
Accurate Measurement,Quick Processing,and Real-Time Display- SEIKO supports swimmimg competitions in a comprehensive manner.

ALGE Water Polo Scoreboard

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

DTM 60, DTM60A, DTM 60EL, DT 100, DT 483, DT 483A STOPWATCH OPERATING INSTRUSTIONS

Manual Weighingblock VB2 series and Uniscale

Scoreboard Operator s Instructions MPC Control

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

TdC 8001 Page 2. Version:E Page 2

Qi Litre Ultrasonic Cleaner

TH-1800-T TRX-700-CNG Converter

TdC 8000 plus. English

SonoMeter 30 Energy Meters

DIGITAL AUTOMATIC TYRE INFLATOR

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Electronic gas volume corrector model DGVC-04

TdC 8000 Page 1. Version: E Page 1

istart Owner s Manual

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

Lil Mix Controller (Order code: LEDJ122)

OMNISPORT 2000 SWIMMING QUICK REFERENCE

Heavy Duty Dissolved Oxygen Meter

MAY 2015 EQUIPMENT LIST CONTENTS: 1. SWIMMING LANES 2. STARTING BLOCKS 3. STORAGE DRUMS FOR SWIMMING LANES 4. WATERPOLO GOALS AND FIELD LINES

Pneumatic high-pressure controller Model CPC7000

Easy to operate even for biginners. Set up the number of test. Possible to select from 1 to times

Aquacom Diving Equipment

Technical Data Sheet MF010-O-LC

Help Manual. (MTB Edition)

Version-E Manual

MULTISPORT SCOREBOARDS - REF. 452 SUPER PRO Range - Readability 160 m

Hand-held pressure calibrator with integrated pump Model CPH6600

REGNLY TIME RECORDER RTR 2 USERS MANUAL CONTENTS

J12 TICKET DISPENSER HOPPER ALL STOP STOP 1 STOP 2 STOP 3 BIG DOUBLE SMALL TAKE PLAY START CURRENT PRODUCTION BOARD TYPE

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Operating Instructions Part No

Precision digital pressure gauge Model CPG1000

Technical Description ALGE Aquatics System

Scoreboard Operator s Instructions MPCW6 Control

Operation Guide Training

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK

COSMO INSTRUMENTS CO., LTD.

Digital pressure gauges

DANAGE TIMER System Controller User Manual

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

Over 80 years of experience in precision weighing and UniBloc technology

Oxygen Meter User Manual

Pneumatic high-pressure controller Model CPC7000

DFX II Series. Digital Force Gauge

Columbus Instruments

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

BUBBLER CONTROL SYSTEM

Easy to operate. Wide space

UniBloc technology and over 80 years of experience in precision weighing. Registered

CCT-7320/ROC-2313 Reverse Osmosis Controller

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Operating instructions Electrical switching facility pco

Dräger X-act 5000 Automatic Dräger Tube Pump

ELIMINATOR INSTRUCTIONS Table of Contents

TorMinal. Operating instructions V OCE-Rev.L_EN

AHE58/59 AC Servo System

CMA4000 Specifications

Do Not Print This Page.

YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD.

RADIOLOGY/ FLUOROSCOPY 15 RAD-CHECK PLUS X-RAY EXPOSURE METER

BTX6002. BODET SA BP Trémentines I FRANCE Tél Fax

Portable oxygen concentrator

SC-888 Instructions. The following illustration provides the operation of pushbuttons and location of indicators for the Robic SC-888.

ACV-10 Automatic Control Valve

TECHNICAL DESCRIPTION

130 SSP Soluble Salt Profiler

Alimak Lift Control, ALC II User s Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

WATCH COLLECTION NG701 SERIES INSTRUCTION MANUAL

BT 2000 range Score / Club / Classic / Alpha

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

ALGE SWIM2000. Architectural Guideline ALGE

STAND alone & p.c. VERSION

High-performance submersible pressure transmitter For level measurement Model LH-20

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Expert Hydrostatic Level Transmitters

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

Star Knit International. Gym and Fitness products

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

RM-80 respiration monitor

MP-70/50 Series Scoreboard Controller User Guide

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

CONGRATULATIONS ON OWNING YOUR NEW NAUTICA WATCH DEVELOPED FROM ADVANCED ELECTRONICS TECHNOLOGY, THE MOVEMENT IS MANUFACTURED FROM THE BEST QUALITY

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

Pedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX

BUYER S GUIDE AQUAlogger 530WTD

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

Transcription:

SEIKO MULTI TIMING SYSTEMS PS-0 http://www.seiko-sts.co.jp

Features Five measurement modes, including counting, parallel counting, parallel lap time and split time measurement, parallel delay start and group parallel counting, are available to cover all kinds of sports events and practices. The sports printer measures in /,000 second increments. Selection from the 0 arithmetic operations such as raising, discarding or rounding off the decimals can be made to print out the data according to the type of the sports event. The data obtained from start till the end of a race is recorded as a block and stored in memory. Up to,000 data and up to 00 blocks of data can be stored in memory. Recall and reprint can be selected from only the desired block of data and all the blocks of data. The lithium ion battery is used to power the sports printer, enabling the printer to be used in many places, while making it easy to handle the power supply. The data can be output to external equipment such as scoreboards and personal computers. SEIKO MULTI TIMING SYSTEMS SEIKO SPORTS PRINTER System Components Sports Printer: unit Roll Paper: roll Lithium ion battery: pcs. (GS-): pcs. Ribbon Cassette: pce. Battery Charger: pce. Battery Charger Main Unit OPTION Expansion Unit EX-96 An input channel can be expanded to the maximum 0 channels. OPTION Synchronization Cable / SY-456 Ribbon Cassette / ERC- Roll Paper / RP-0

Main Functions Up to hours, 59 minutes, 59 seconds and 999 can be measured. The order of arrival can be counted from to 9,999. Time to a maximum 0 lanes (0 channels) can be measured by the use of EX-96. Starting from the preset time, not only starting from 0, is available. Counting down from the preset time to 0 is available. Furthermore, in addition to the above count-down function, counting up from 0 continuously after count-down is useful for marathons. s, connected by synchronizing cables (SY-456), will execute time recording complete synchronization. A trunk-type case is used as the housing of the sports printer to ensure a longer durability. The housing has an accessory storage compartment to accommodate the grip switch and other accessories to carry the sports printer smoothly. As the sports printer is compatible with CT-96, the various optional equipment for CT-96 can also be used with the sports printer without any modification. OPTION GS- with.5m cable GS- with 5.5m cable GS- with 0m cable Specifications Time accuracy Time measuring range Time measurement resolution Number of simultaneously measurable input channels Daily rate: 0. seconds ( 5 ) Up to hours, 59 minutes, 59 seconds 999 in hours, minutes, seconds. Raising, discarding and rounding off /0 seconds, /00 seconds and /,000 seconds. Control panel: channels Connectors: channels EX-96 (option): 0 channels Memory capacity Display unit Printer unit Power supply Temperature Appearance Display element Display item Printer Printing paper Lithium ion battery Recharger For use For storage Dimensions Up to,000 data, and up to 00 blocks of data LCD Calendar and time data Time counter display Battery life indicator EPSON M-90 model (Mechanical 5x7 dot matrix 4 char./line).5 line/sec. Ordinary roll paper having a diameter of 57.5 mm ± 0.5 mm x 70 mm or smaller DC7.V, 0.8Wh, pieces AC00V 40V, 50/60 Hz 5 40 (non-condensing) 5 55 (non-condensing) W 58 x H 07 x D 57 mm (excluding protruding portions) Panel: Steel, Case: Aluminum Approx. 4.6 kg.

Features As an upcount timer and downcount timer, it can be used as a timing display system for various sports event including swimming, track races, marathon, walking race, skiing, cycling, soccer, and rugby and basket ball and other games. can also be used for the display of game points and deuce points in tennis. can measure lap time, split time and finish time. In addition, it can memorize and re-display either lap or split times for a maximum of 5 athletes. has an auto repeat function in which the time is upcounted and downcounted at fixed intervals to sound a buzzer at a preset time. Accordingly, can be used as a pace-clock. is battery-powered, and can be used both indoors and outdoors. OPTION Stand / ST-0 W,000 x H,000 x D,000 mm SEIKO MULTI TIMING SYSTEMS SEIKO SPORTS TIMER Main Unit System Components Sports Timer pce Battery Box: box Main Functions The following three maximum time ranges are available which can be changed over from each other to cover a wide range of sports events: a)99h59m59s b)59m59s9 c)59m59s99 The upcount function is available in two modes: one in which the time is counted up from zero, and the other in which the time is counted up from a preset time. The downcount function has a crossover counting mode in which the time is downcounted from a preset time to zero and in succession upcounted from zero. This mode is suitable for marathon and the like. can be used in combination with a wide variety of SEIKO sports equipment. Specifications Display Time accuracy Measuring function Upcounting Downcounting Maximum measuring time Memory and memory call Preset time Magnetic rotary bar, yellow, character height 00mm, 6 digits 0.04 sec/hr. ( 5 5 ) 99h59m59s (59m59s9, 59m59s99) Lap or split time. Count or number of measurements storable: 5 max. 99h59m59s s. Auto repeat (REPEAT) Automatic cyclic time counting from 0 to a preset time, and beeping of buzzer for approx. 5 sec. after every expiration of preset time. "AA" dry cell x 8 pcs. LR06"AA" alkaline dry cell: approx. 50 hrs. (at 5 ) Indoors and outdoors (provided that permanent outdoor installation is prohibited. ) Power supply Battery service life under continuous duty Operating environment Location Temperature For use For storage Appearance Dimensions Grip switch Equipment available for connection with 0 50 (non-condensing) 0 55 (non-condensing) W,0 x H 0 x D 50 mm Aluminum, yellow.5kg (including dry cells) Cord length, 5 m, 60; w//stop and LAP/SPLIT/RESET buttons PS-0/09/07/05, /96, CT-400/00, PT-7000/6000, ST-000/900/800 series, RT-0, WG-00/00, DM-400/00/00 * Typical value when operated continuously in the upcounting mode. It should be noted that the battery service life varies dependent on the operating conditions, parameter settings, ambient temperature and other environmental conditions.

Features PS-0 is an electronic audio-visual start signal generator that can be used for all types of events. It generates a start signal by sound and flashlight. PS-0 does not use gunpowder, and is safe to handle and storage. Misfire when due to send off a signal or nuisance trailing smoke after fire has nothing to do with the electronic starter. PS-0 can generate a synthesized firing signal or an electronic beep, whichever is preferred. The starting officer can use the Headset Microphone to amplify and communicate his/her voice message to the athletes. PS-0 can be used with one Speaker Box or more or with other equipment to suit your sports system. SEIKO MULTI TIMING SYSTEMS PS-0 SEIKO ELECTRONIC ING SYSTEM System Components Start Pistol (PS-78): pce. Speaker Box (PS-56): pce. Headset Microphone (PS-6): pce. Cable with a termination box (PS-8): pce. Cable with a termination box Headset Microphone Start Pistol Speaker Box Specifications Start Pistol (PS-78) Speaker Box (PS-56) Strobe Power supply Battery life (alkaline dry cells) Temperature For use For storage Appearance Dimensions Headset Microphone (PS-6) Xenon lamp LR06 AA alkaline dry cell x pcs. (DC V) Approx.,00 times (Number of times light can be emitted continuously in -minute intervals.) 0 50 (non-condensing) 5 60 (non-condensing) W 0 x H 40 x D45mm Aluminum, black gray Approx. 40g (excluding dry cells, cord) Audio input Rated output Power supply Battery life (alkaline dry cells) Operating sound pressure level Temperature For use For storage Appearance Dimensions 0dB (00K ) 6 W (max. 0 W) LR06 AA alkaline dry cell x 8 pcs. [DC V] Pistol sound: approx. 8,000 operations until sound pressure falls below 9 db (at a distance of 0 m) 9dB (at a distance of 0 m) 5 40 (non-condensing) 5 50 (non-condensing) W 0 x H 58 x D 6 mm ABS resin, ivory Approx..6kg (excluding dry cells) Output Sensitivity Type Appearance Dimensions Impedance,.6k, 0% 68dB db Condenser microphone W 60 x H 68 x D 70 mm ABS resin, black Approx. 45g (including cord) 4

How to use SEIKO Multi Timing Systems. 6 - M O D E S Y S T E M Track events, marathons & cycling races, etc. The times from the start to finishes (channel inputs) and the places (number of inputs) are printed out. The places are printed out in four digits (000 to 9999). After reaching the count 9999, the placing count recycles to 0000, and repeats again.(9999 0000 000 000 - - ) Print Image PS-0 Count No.(Place No.) Time Data Test Print Mark (Place Nos.were cleared) Track events, swim meets & marathons, etc. In this mode, the count mode is used for each lane (channel), the lane numbers (channel numbers), number of laps, and times are printed out. EX-96 (option) allows for max 0 channels of grip switch input. Input Expansion Unit EX-96 Option PS-0 PS-0 Input Expansion Unit EX-96 Option CLASS CLASS CLASS CLASS 4 Print Image Example of 800m Track Event Print Image Example of Marathon (Four Classes) Input Channels (Lane No.) Number of laps First lap for No.0 No.04 No.07 No.0 No.05 No.06 No.08 No.0 nd lap for No.04 Channel No. (Class No.) Count No. (Place No.) The st finish time of Class 4 The nd finish time of Class 4 Two es are furnished as standard. Additional es are available upon request. 5

A multi-function timer designed for use in various sports events. Model started by PS-0 or outputs data / results to in different applications. Speed skating,various relay events & motor sports, etc. In this mode, every time record and the difference between two successive time records are printed simultaneously for each lane (channel). In a race where the contestants are required to make a number of laps., channels are assigned to respective contestants, and the lap times and split times of each contestant can be measured and recorded. The mode is also useful in obtaining data for pace scheduling. Print Image Example of Speed Skating PS-0 Grip Switch Lane No.. Number of laps The st split time of the nd lane The st split time of the st lane The nd split time of the st lane The nd lap time of the st lane The nd split time of the nd lane The nd lap time of the nd lane 4 Marathons & Nordic skiing, etc. This mode is suitable for citizens marathon, Nordic skiing, and the like in which starting is made one by one or in groups sequentially. Enter an input every time a contestant of each group has reached the finish line, and the will print out the finish No., finish times, places, and split times. EX-96 (option) allows for max 0 channels of grip switch input. Print Image Example of Nordic Skiing Start of First Group (MEN) at 0:00 Start of Second Group (WOMEN) at 0:0 Group No. Places The time which a time counter was st group/men start time nd group/women start time The finish time of the top contestant in the st group. The split time of the top contestant in the st group. The finish time of the nd contestant in the st group. The split time of the nd contestant in the st group. The finish time of the top contestant in the nd group. The split time of the top contestant in the nd group. The finish time of the nd contestant in the nd group. The split time of the nd contestant in the nd group.. WOMEN. MEN. MEN. WOMEN 6

5 Track events and swim meets, etc. This mode handles official track events, swim meets, etc. where three judges are required per lane. In this case, three channels are used for one competitor and the middle time recorded of the three is printed out with a mark =. PS-0 4 5 6 7 8 Print Image Example of Swimming Lane No. 4 5 Synchronization Cable SY-456 Option 6 7 8 Official Time Mark Number of laps Judge No. Input Expansion Unit EX-96 Option Two es are furnished per printer as standard. Additional es are available upon request. 6 Marathons, etc. Multiple units of can be started simultaneously by one.those s and are utilized such as for marathons. Example Connect and start # at point by. Once started, disconnect from to run as an independent timer of. PS-0 Connect and run # at FINISH point or the on a CAR. After operated independently, disconnect as well. All those units of keep the same timing as. The design and specifications are subjects to change without prior notice for product improvement. -4-,Fukuzumi,Koto-ku,Tokyo 5-860,Japan Phone +8-5646-60 / Fax +8-5646-60 http://www.seiko-sts.co.jp 009. TO