While testing the double check can I move the bleed valve arrangement from the test cock to the gage when field testing the double check?

Similar documents
~ "'''tt''t4. Ninth Edition of Manual to Use New Testing Procedure. ~ CEUs Offered FOUNDATION FOR CROSS-CONNECTION CONTROL AND HYDRAULIC RESEARCH

S & M Water Consultants

A New Look. Contents. Flipping the Disc p. 3. Thermal Expansion p th Edition Manual p. 7

AIR GAP (AG) Low Hazard High Hazard

Backflow What is it? City Water. Boiler. Make-Up Water Line

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Page1 of 12

553 Series.

Testing Procedures & Trouble Shooting Guide Reduced Pressure Zone Assembly (1/2, 3/4", 1, 1 1/4, 1 1/2" & 2 )

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING

A cross-connection1 is the

Backflow Prevention & Cross-Connection Control Manual For the Education of Ohio Certified Backflow Prevention Technicians.

Cross Connection Control. 2 CE Hours

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Winter Shut Down Procedure

API th Edition Ballot Item 6.8 Work Item 54 Global Air Failure

SB AXIAL FLOW VALVES

Bermad Pressure Reducing. Model: 42T

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

MANUAL BE SERIES Test Benches

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

STATE OF CONNECTICUT CROSS CONNECTION CONTROL MANUAL

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Bladder Tank Installation & System Design Information

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

GAS SUPPLY APPLICATION GUIDE

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

ELKHART BRASS MANUFACTURING COMPANY

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

1 Exam Prep. Tabs and Highlights

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

Model TWBS.SH Tempered Water Blending System

Rate of Flow Valve Series 120

WW-730. Pressure Sustaining/Relief Control Valve

SINGER MODEL 106/206-RPS-L&H

FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE. Gary S. Beckett

T e l N o : F a x N o : E m a i l : a i s h c m c - m e. c o m w w w. c m c - m e.

WHITE PAPER. SmartPlant P&ID Engineering Integrity 10 Example Rules

Lesson 6: Flow Control Valves

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

OPERATION MANUAL NTF-60 Plus

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

Principle of Operation. Features. Applications. CL34 Operating Schematic

Speed control assembly model A-1

Early evap monitors. Photo courtesy Toyota Motor Sales, U.S.A., Inc.; diagram courtesy University of Toyota

2 Sentry MCL Installation, Operation & Maintenance

The Discussion of this exercise covers the following points:

Supplementary Operator s Manual 42/24-14 EN Rev. 3

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Wilo Triple Duty Valve / Triple Service Valve Installation and operating instructions

TECHNICAL DATA. Table 1 - Specifications

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

Pressure Measurements

The Electronic Newsletter of The Industrial Refrigeration Consortium

OPERATION MANUAL NTF-15

TROUBLESHOOTING GUIDELINES

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

IWCF Equipment Sample Questions (Surface Stack)

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

Committee on NFPA 85

FILTER BYPASS CONTROL

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011

Periodical surveys of cargo installations on ships carrying liquefied gases in bulk

Section 10 - Hydraulic Analysis

EDUCATION DEPARTMENT ACCU-TEST

Easy Nest Kits. Installation Suggestions

User's Manual. MixRite TF 10. Edition 05.08

TECHNICAL DATA Q= C. Table 1 - Specifications

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Driver Operator Pumps: Basic Pump Operations

PRODUCT SERIES: A-SF-3000BD

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Model: 43T. Bermad Pressure Relief Valve

TECHNICAL DATA. than the water inlet pressure to the concentrate

Installation Manual. Model # SF-3W 9/16/03 REV 1. Arch Chemicals, Inc Lower River Road. P.O. Box 800 Charleston, TN PULSAR

Warning: NEVER ALTER TEST EQUIPMENT

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

RS(H)20, 25 USER MANUAL

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

SYSTEM REGULATING VALVES PRESSURE RELIEF VALVE - SRV BRASS & S/STEEL ADJUSTABLE

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Type EZH Relief or Backpressure Regulator

American Society of Sanitary Engineering

Cable Pressurization Buffering

September 2018 Pressure Test

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Control Valves, Actuators, & Pressure Safety Valves

ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN

Combination Air Valve

Cavitation in Valves

Series 867. Reduced Pressure Zone Assemblies " 3" (65 80mm)** INDEX. Testing INSTALLATION INSTRUCTIONS WARNING NOTICE NOTICE !

ASSE International Product (Seal) Listing Program

Transcription:

S p r i n g 1 9 9 8 Questions and Answers about Field Testing Backflow Prevention assembly testers often call the Foundation office with questions regarding some particular field test procedure. Many questions are also posed by those attending a Foundation Training course, or those preparing for a certification exam. Here are a couple of the most comonly asked questions about field testing the double check valve assembly under the Ninth Edition of the Manual of Cross-Connection Control. While testing the double check can I move the bleed valve arrangement from the test cock to the gage when field testing the double check? The bleed valve is used during the field test ofthe double check valve assembly to compensate for a limited leak in the No. 1 shutoff valve. (See Figure 1 on page four.) It may seem that the tester can still control the amount of water coming out of the bleed valve should it be attached to the gage instead of the test cock of the assembly. (See Figure 2 on page four.) After all the water is still leaking through the No. 1 shutoff valve and being bypased to atmosphere before reaching the check valve, thus allowing the check valve to seat. However, even though the tester may compensate for the leak Continued on page four Troubleshooting There s more to a Test than hooking up a gage Many of those attending the Foundation s Course for the Training of Backflow Prevention Assembly Testers are surprised to find out how much there is to learn. This is because many are not aware of all that is involved in testing a backflow preventer until they actually perform the test themselves. Although the initial test of each of the backflow preventers may be considered fairly simple after some training; the complexities come in with the troubleshooting portions of the testing. There are several problems, which may occur with each of the assemblies being tested: the double check valve assembly, the reduced pressure principle assembly and the pressure vacuum breaker assembly. The testing procedures for each of the assemblies, including troubleshooting will be examined briefly in this article. The Double Check Valve Assembly According to the Ninth Edition of the Manual of Cross-Connection Control, when testing the double check valve assembly, the tester wants to determine if each of the two check valves holds the minimum acceptable value of 1.0 psid in the direction of flow. Additionally, we can determine if either of the shutoff valves is leaking, with or without backpressure. The troubleshooting becomes even Continued on page three I n s i d e C r o s s T a l k Field Testing the Double Check Manual Progress Troubleshooting New Members

The Foundation s Membership Program provides many benefits to the Members of the Foundation. These include: twenty percent discounts on Foundation Training courses for any employee of the Member company/ organization, the List of Approved Backflow Prevention Assemblies, printed quarterly, and access to the up-to-the-minute version of the List for those Members with Internet access. Foundation Membership Two Members are encouraged to call the Foundation with technical questions. The Foundation s Engineering Staff is available to assist Members with the various aspects of field testing backflow preventers, installing backflow preventers, and administering their cross-connection control program. ABC WaterWorks, Inc. Advance Septic and Drain, Inc. Arkansas Dept. of Health Backflow Management Inc. BFP Technicians Billy Newton Boca International Carroll, Daniel CET Environmental Services, Inc. DeSoto, City of Duarte, Joe DuFrene, Geoff Harlick Testing, Plumb., & Fire. Co. Imperial Plumbing, Inc. JEA-MAR Sales Jones, Luis Local 166 Joint Apprenticeship McCarran Airport McKay, Eilliam T. Mississippi W.P.C.O.A. Inc. Mississippi, State of Naval Air Warfare Center Nevada Rural Water Assoc. Palmdale Water District Quality Assured Packing Inc. Redlands Plumbing Co. Roanoke, City of Tennessee Association of Utility Districts UCSD Medical Center Vatterott College Ventura County Waterworks Dist. #1 Contacting the Foundation Mailing Address: Foundation for Cross- Connection Control and Hydraulic Research University of Southern California Kaprielian Hall 200 Los Angeles, CA 90089-2531 Phone: 213 740 2032 FAX: 213 740 8399 e-mail: fccchr@usc.edu Web Site: www.usc.edu/dept/fccchr The Foundation accepts Purchase Orders via mail or fax and credit card orders (Visa, MasterCard, Discover) via telephone and the Web. Cross Talk is published by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California for Foundation Members. Limited additional copies are available to Members upon request. (213) 740-2032 1998 University of Southern California. All rights reserved.

Troubleshooting continued from page one more complex when two or more problems occur simultaneously. Possible scenarios while testing the double check include the following: 1. Everything working properly 2. Leaking No. 1 shutoff valve (but testable) 3. Leaking No. 1 shutoff valve (too severe to test) 4. Low reading on No. 1 check valve (0.1 0.9 psid) 5. Low reading on No. 2 check valve 6. Leaking No. 1 check valve (0.0 psid) 7. Leaking No. 2 check valve 8. Leaking No. 2 shutoff valve 9. Leaking No. 2 shutoff valve with backpressure. The Reduced Pressure Principle Assembly In testing the reduced pressure principle assembly, there are three items we are essentially looking at: The first check valve, the second check valve, and the differential pressure relief valve. We also have the possibility of a leaking No. 2 shutoff valve, with or without backpressure. The relief valve must open at a differential pressure of at least 2.0 psid. The first check should hold at a value of at least 3.0 psid above the relief valve opening point. Although this buffer value of 3.0 psid may vary from one administrative authority to another. The Foundation s recommendation is a 3.0 psid buffer as this is part of the design criteria. Some of the possible scenarios while testing the reduced pressure principle assembly include } the following: ~ 1. Everything working properly 2. Leaking No. 1 check valve 3. Low No. 1 check Because of the many complex scenarios which a backflow prevention assembly tester experience, the Foundation s Tester Training Courses place a large emphasis on troubleshooting continued on page six Three

Field Testing, Q & A continued from page one in this manner, the location of the bleed valve may cause an error in the gage reading. The gage is most accurate when there is no water flowing though the gage manifold or the hose. As illustrated at the top center of these pages, the pressure on either end of the hose is the same when there is no flow through it. As water flows through the hose, pressure is lost. This is due to friction between the water and the inside surface of the hose. The same phenomenon also occurs as water flows through any piping system. The Illustration at the bottom of the next page shows how water flowing through the hose changes the pressure reading from one end of the hose to the other. The less straight the hoses are, the more friction loss there is. It takes more energy for water to flow through curved sections of hoses or pipes than to flow through straight sections. So, curves, or wrapping part of the hose around the gage, could also affect the pressure loss through a given length of hose. This doesn t mean that the hoses need to be straight during normal testing. The procedures are designed to minimize the errors due to friction loss. It is also important to keep in mind these graphics are only for illustration purposes and exaggerate the pressure differences. Taking this concept and transferring it to the DC field test procedures, it is found that water flowing through the hose could cause a false reading at the gage. This is why the procedure calls for the bleed off valve arrangement to be attached to the upstream test cock as opposed to the gage itself. Four

Can I use the bleed needle valve on my gage instead of the bleed valve arrangement? Bleeding the water through the high bleed valve on the gage instead of from the upstream test cock will create similar problems as attaching the bleed off valve to the gage, as discussed earlier in this article. In fact, the same problem would occur. Additionally, the flow of water through the gage past the high pressure sensing region may cause false readings. Water flowing through the top of a tee could reduce the pressure on the leg of the tee, siphoning water up the leg of the tee. In fact this is a common means of creating backsiphonage. See the tee to the right. This aspirator effect can cause false gage readings. This is the reason, in several cases, there is a limit of opening a needle valve only onequarter turn. This limits the amount of water flowing past the gage and prevents false readings on the gage. When testing the reduced pressure principle assembly, for example, the tester should not open the low side control needle valve more than onequarter turn when determining the relief valve opening point. If the needle valve is opened more than one-quarter turn, the gage may give false readings due to this aspirator effect. Water flowing through the top of a tee could reduce the pressure on the leg of the tee, siphoning water up the leg of the tee. In fact this is a common means of creating backsiphonage. Five

Troubleshooting continued from page three The backflow preventers used in Foundation Training Courses are modified so that various scenarios may be created with the turn of a valve or two. valve 4. Low relief valve opening point ( 0.1-1.9 psid) 5. Relief valve does not open. 6. Leaking No. 2 check valve 7. Leaking No. 2 check valve with backpressure. 8. Leaking No. 2 shutoff valve 9. Leaking No. 2 shutoff valve with backpressure 10. Low buffer between relief valve opening and No. 1 check reading The Pressure Vacuum Breaker Assembly The pressure vacuum breaker assembly contains a check valve and an air inlet valve. The tester must determine if the check valve holds at least 1.0 psid in the direction of flow and whether or not the air inlet valve opens above 1.0 psid. The tester should also be able to determine if either of the shutoff valves is leaking. When testing the pressure vacuum breaker assembly any of the following scenarios may exist: 1. Everything working properly 2. Leaking check valve (0.0 psid) 3. Low check valve reading (0.1-0.9psid) 4. Low air inlet valve reading (0.0 0.9 psid) 5. Air inlet valve doesn t open 6. Leaking No. 1 shutoff valve 7. Leaking No. 2 shutoff valve As the various combinations are encountered this list grows longer and longer. It can be seen easily that the complexities of the field test procedures are well beyond the hook up a gage and see if it works concept that many people have. The proper field testing of a backflow prevention assembly requires a thorough knowledge of the procedure and the many potential scenarios. The skills of a backflow prevention assembly tester go well beyond following a set of steps by rote. The tester must have a solid understanding of how the assemblies work. With this knowledge the tester is able to determine what is occurring internally from the observances made on the gage at different junctures in the field test procedure. This is why the Foundation s Tester Training Courses place so much emphasis on troubleshooting the assemblies. The tester must have the opportunity to test assemblies with different scenarios in order to recognize the various problems, which occur while field testing. The backflow preventers used in Foundation Training Courses are modified so that various scenarios may be created with the turn of a valve or two. This enables the students to practice the field test procedures with the various conditions being simulated. Six

Manual Update New Concept of Detector Assembly Suggested The Manual of Cross-Connection Control is currently under revision. With this revision the Manual Review Committee (MRC) has had several open meetings. During these meetings representatives of backflow prevention assembly manufacturers, gage manufacturers, water agencies, health agen- cies, and individuals are welcome to present any information to the committee which they feel will benefit the users of the Tenth Edition of the Manual. Several suggestions have already been made. One innovative suggestion, which has been approved in concept, is the suggestion that specifications for a new type of detector assembly be included in the next edition of the manual. The specifications would be for both a double check detector assembly and a reduced pressure principle detector assembly. Initially many think that this type of assembly will not provide the protection that the original concept of a DCDA and RPDA provide. However, upon close examination, the assembly provides the same level of protection. Shown here is a computergenerated concept of the new type of DCDA. Note that all water flows through the number one check valve AND either the number two check valve or the bypass check valve. So all water must flow through two check valves. Likewise, any backflow would need to overcome two check valves just as with the currently approved DCDAs. Any suggestions or comments regarding the Tenth Edition of the Manual may be sent to the Foundation office or comments may be left on the MRC web site. The latest information is also available on this web site..usc.edu/de.edu/dept/fccc pt/fccchr/mr hr/mrc/ Any suggestions or comments regarding the Tenth Edition of the Manual may be sent to the Foundation office or comments may be left on the MRC web site http://www.usc Seven

Training Courses Tester Course Los Angeles, CA 13-17 July 1998 Incline Village, NV 17-21 August 1998 Charleston, SC 14-18 September 1998 Las Vegas, NV 19-23 October Specialist Course Los Angeles, CA 20-24 July 1998 Las Vegas, NV 2-6 November 1998 Upcoming Events JIC Workshop Santa Ana, CA 12 August 1998 N. California Backflow Prevention Association Annual Workshop Pleasanton, CA 27 August 1998 Inland Counties Backflow Group San Bernardino, CA 23 September 1998 Blue Grass Cross-Connection Prevention Association Lexington, KY 25 September 1998 Western Regional Backflow Conference Las Vegas, NV 28-30 September 1998 CA/NV AWWA Fall Conference 28-30 Sept - Western Regional Backflow Conference Reno, NV 7 October 1998 Foundation for Cross-Connection Control and Hydraulic Research School of Engineering University of Southern California Kaprielian Hall 200 Los Angeles, California 90089-2531 First Class US Postage PAID University of Southern California