Experiment #2. Density and Measurements

Similar documents
CHM 100 / Introductory Laboratory Experiment (r10) 1/11

Measurements. Metric System

CHM Introductory Laboratory Experiment (r17sd) 1/13

Measuring Mass and Volume

Purpose. Introduction

BASIC LABORATORY TECHNIQUES (Revised )

EXPERIMENT 1 BASIC LABORATORY TECHNIQUES AND TREATMENT OF DATA MEASUREMENTS

The use of the analytical balance, and the buret.

Name: Period: DUE Friday 9/ 16 Honors Chemistry Lab #1: Metric System

BASIC LABORATORY TECHNIQUES (Revised )

Part A How Many Drops Are in 1 ml of Water?

Density of Brass: Accuracy and Precision

VOLUMETRIC TECHNIQUES

Hands-On Experiment Density and Measurement

Lab #1: Introduction to Lab Techniques INTRODUCTION

Buoyancy and the Density of Liquids (approx. 2 h) (11/24/15)

Technique Sheet 16. Using the Metric Ruler

EXPERIMENT 2. Laboratory Procedures INTRODUCTION

download instant at Experiment 2 A Submarine Adventure: Density Saves the Day

Lab 1: Precision and Accuracy in Measurement (Using the right tool for the Job) and Density of Metals

Figure 1. Example of volume of water required for an unknown sample

Lab Equipment ANALYTICAL BALANCE

Experiment 1, Measurement and Density Chemistry 201, Wright College, Department of Physical Science and Engineering

Experiment 1 Introduction to Some Laboratory Measurements

Gas Laws. Figure 1: Experimental Set-up with Leveling Bulb. GCC CHM 151LL: Gas Laws GCC, 2019 page 1 of 8

Read ENTIRE lab up to Disposal Section. MAKE NOTES!!! **For Procedures, Highlight equipment used and circle quantities measured out.

1. Determining Solution Concentration

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

CONCEPTUAL PHYSICS LAB

Recording Significant Figures

Scientific Measurements and Errors: Determination of Density of Glass

The Rules. 1. Conduct yourself in a responsible manner at all times in the laboratory.

MEASURING VOLUME & MASS

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq)

Objective To identify a pure liquid substance using the physical properties of solubility, density, and boiling point.

The density of a substance is the same for all samples of that substance.

Real World Metric System

Additional Reading General, Organic and Biological Chemistry, by Timberlake, chapter 8.

CHEM 321 Experiment 1

Target Density Lab SCIENTIFIC. Density Inquiry Lab Activities. Introduction. Concepts. Materials. Safety Precautions. Preparation

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq)

LABORATORY TECHNIQUES. Pouring Liquids

Inquiry Module 1: Checking the calibration of a micropipette

EXPERIMENT 1 TOOLS FOR LAB MEASUREMENT

Laboratory Activity Measurement and Density. Average deviation = Sum of absolute values of all deviations Number of trials

How to Measure R7.1. Reference. I. Linear dimensions

Calibration of Volumetric Glassware

Experiment 1 Basic Laboratory Operations

Students will use two different methods to determine the densities of a variety of materials and objects.

Any laboratory is equipped with specific tools, equipment,

QAM-I-117 Volumetric Equipment Calibration Verification

CHM250 Calibration and Measurement Lab. Balance Calibration

NAME BLOCK Density Lab PROBLEM: How can we determine the densities of different substances?

Experiment #12. Gas Laws.

1. If grams of the vapor of a volatile liquid can fill a 498 ml flask at o C and 775 mm Hg, what is the molecular mass of the gas?

Scuba Divers Science Performance Task Grades 5-8 Name: Scuba Divers

Accuracy and Precision

Location and Use of Safety Equipment. Extinguisher Shower Fire Blanket

R: The Ideal Gas Constant Pre-Lab Assignment

The Ideal Gas Constant

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

CHM111 Lab Gas Laws Grading Rubric

EXPERIMENT 8 Ideal Gas Law: Molecular Weight of a Vapor

CHM 2045L Physical Properties

MOLEBIO LAB #1: Microquantity Measurement

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

BASIC LAB SKILLS: EIGHING BALANCE AND BUNSEN

Pipetting Small Volumes

Experiment 13 Molar Mass of a Gas. Purpose. Background. PV = nrt

Hydrostatics Physics Lab XI

I CAN: Define Volume, know that it is a property of matter, and measure volume accurately.

Adaptations of Desert Plants

CHM 317H1S Winter Section P Procedures and Tables

Determination of the Gas-Law Constant (R) using CO2

Remedies for Common Laboratory Ailments

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Overview of Density Worksheet

In case of emergency or accident: 1. Call the instructor immediately. Describe the nature of the accident or injury.

Experiment 12: MOLAR VOLUME OF AN IDEAL GAS

Density and Archimedes Principle 11-cor

LAB 7. ROTATION. 7.1 Problem. 7.2 Equipment. 7.3 Activities

Biochemistry Laboratory I CHEM 4401 Pipetting & Scales

Customary Units of Length

Name:. Correct Questions = Wrong Questions =.. Unattempt Questions = Marks =

LABORATORY SAFETY EQUIPMENT Final Grade: /45

Experiment P18: Buoyant Force (Force Sensor)

UNIT PLAN. Grade Level: 3 Unit #: 4-2 Measurement: Length, Volume, Mass, & Equivalencies

MassWWP Standard Operating Procedure R-2 Dissolved Oxygen Rev.0 Page 1 of 10

The Decomposition of Potassium Chlorate

General Laboratory Rules Graphing Data...13

Standard Practice for Calibration of Laboratory Volumetric Apparatus 1

Pearson Education Limited Edinburgh Gate Harlow Essex CM20 2JE England and Associated Companies throughout the world

General Chemistry I Percent Yield of Hydrogen Gas From Magnesium and HCl

Student Exploration: Archimedes Principle

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

Eric Sheagley, Lab Supervisor Fall, 2015

Objective: Decompose a liter to reason about the size of 1 liter, 100 milliliters, 10 milliliters, and 1 milliliter.

00 Experiment: Basic Lab Techniques, Compliance of GLP and Calibration of Glassware

3. A fluid is forced through a pipe of changing cross section as shown. In which section would the pressure of the fluid be a minimum?

Transcription:

Experiment #2. Density and Measurements Goals 1. To measure and record length, volume and mass accurately with the correct number of significant figures 2. To use significant figures correctly in calculations. Making Measurements Measurements are central to science and medicine. Scientists and medical professionals need to read and report measurements accurately and precisely to convey information to others. In this lab you will to learn how to read scientific instruments and report the results with the correct number of significant figures. Measurements contain certain and uncertain digits. The final digit of a measurement is assumed to have uncertainty and is usually estimated from the instrument being read. You will be expected to carefully and correctly record measurements using the procedures below for rest of the course. Units of Length We will use rulers to measure length. The standard unit of length in the metric system is the meter (m). A meter is divided into 100 centimeters (cm). Each centimeter is divided into 10 millimeters (mm). Measurements taken with instruments with a scale, such as rulers, should be recorded to the nearest 1/10 of the smallest division. Two examples are below. Smallest division on the ruler: 0.1 cm 1/10 of smallest division: 0.01 cm Measurement should be read to the nearest: 0.01 cm The object lies between the 7.2 and 7.3 cm lines. The space between the lines should be mentally divided into 10 to estimate the last digit of the measurement. A correct reading of this instrument could be 7.24 cm. Units of Volume Volume is a derived unit based on length. The unit of basic metric unit of volume is the liter (L). 1 liter is equal to 1 cubic decimeter (dm) 3. There are 1000 ml in 1 L. A milliliter is the same volume as 1 cm 3. 1 liter = (1dm) 3 = (10 cm) 3 = 1000 cm 3 = 1000 ml We will use several types of instruments to measure volume in chemistry class. Beakers glass containers with straight sides used to hold, mix and heat liquids markings give an approximate volume beakers are not used for careful volume measurements

Erlenmeyer Flasks glass containers with tapered sides and a narrow opening. the shape is useful for swirling liquids without spilling and for limiting evaporation markings give an approximate volume Erlenmeyer flasks are not used for careful volume measurements Graduated Cylinders long narrow cylinders with volume markings (also known as graduations) used to accurately measure volume some have a plastic guard to prevent breaks it should be at the top of the cylinder. graduated cylinders are not used to heat liquids the shape of the base does not transfer heat well graduated cylinders are never used to mix substances or hold solids solids get stuck at the bottom of the cylinder and are difficult to mix and clean. using graduated cylinders o various sizes are available, generally the smallest cylinder that can accommodate the volume is used o if two scales are shown, always read the scale that increases up the cylinder o read at eye level o read the measurement at the lowest point of the meniscus (the curved surface of the liquid) o read to the nearest 1/10 of the smallest division Smallest division on the cylinder: 0.2 ml 1/10 of smallest division: 0.02 ml Measurement should be read to the nearest: 0.02 ml The lowest part of the meniscus appears to exactly hit the 6.6 mark. Since the measurement must be to nearest 0.02 ml, 6.6 ml would NOT be a correct measurement. The volume should be recorded as 6.60 ml. Note that on this instrument, 6.60 and 6.62 are possible readings, but 6.61 is not because it implies more precision than this instrument is capable of.

Burets Long narrow tube of glass with a stopcock to release liquid at the bottom. used to measure the volume of liquid has dispensed. measuring volume with a buret o read the volume that has been dispensed, not the volume that buret still contains o read at eye level o read the bottom of the mensicus o read to the nearest 1/10 of the smallest division Smallest division on the buret: 0.1 ml 1/10 of smallest division: 0.01 ml Measurement should be read to the nearest: 0.01 ml The lowest part of the meniscus is between the 15.4 ml and 15.5 ml lines. A correct reading of the volume dispensed could be 15.45 ml. Units of Mass A laboratory balance is used to measure mass. Mass is the measure of the amount of material or matter. The metric unit for mass is the gram (g) while the SI unit of mass is kilogram (kg). The balance has a metal pan to weight materials on. Around the pan, there is a plastic shield and a cover. These protect the balance from fluctuations caused by drafts. Using a balance Press the button labeled tare or zero until the numbers stabilize at zero. o If weighing a chemical, place a weigh boat on the balance before zeroing. Never put chemicals directly on the balance. Place the material on directly on the pan, or scoop into the weigh boat with a spatula. If the last digit fluctuates, you may estimate its value. If the value continues to go up or down, use the shield and cover. Write every digit on the balance on your data sheet - never round off a mass measurement. The final digit is considered uncertain. Weigh boats are single use. Dispose of them once used. Use the same balance for all measurements in an experiment Only weigh objects that are at room temperature. Procedures will often say accurately weigh about 5g of X, this means that you do need exactly 5.000 grams, but whatever mass you portion out should be recorded accurately. For instance 5.080 g and 4.952 g might be recorded as an accurate mass of approximately 5 g. Trying to hit exactly 5.000 g is unnecessary and a waste of time.

Laboratory Activity Materials: 1 metal block Graduated cylinders Buret sodium chloride Ruler Deionized water (in larger white containers on the lab benches) Procedure A. Measuring Mass 1. Practice using an analytical balance by finding the mass of two different weigh boats. (See the discussion on the previous page on how to use the balance) 2. Tare one of the weigh boats before adding sodium chloride. Accurately weigh about 3 g of sodium chloride. 3. Return sodium chloride to the container. Dispose of the used weigh boat in the trash. Note: We normally do not return used reagents to the bottle to prevent contamination. B. Measuring Volume 1. Four types of graduated cylinders (10 ml, 100mL, 250mL, and 500 ml) and a buret with different volumes of water will be placed around the room. Note the value of the smallest division on each piece of glassware and the place the instrument should be read to, then record the volume of the water to the correct number of significant figures. C. Determining the Density of a Metal Block 1. Obtain a metal block, measure its mass using an analytical balance. 2. Obtain a ruler and record the length (l), width (w) and height (h) of your metal block to the correct number of significant figures. 3. Calculate the volume in cm 3 of the metal block. V = l w h. and round to the correct number of significant figures. 4. Calculate the density of the block in g/cm 3 to the correct number of significant figures using your data for volume and density. Density = mass / volume 5. Determine the likely identity of metal block based on the density table below. Metal Density (g/cm 3 ) Aluminum 2.70 Brass 8.74 Copper 8.96 Iron 7.86 Lead 11.4 Steel 7.48

D. Determining the Density of Water Density using a Beaker 1. Record the mass of a dry 150 ml (or a similar sized) beaker to the correct number of significant figures. 2. Fill the beaker roughly 2/3 full with deionized water and record the mass. The amount of water is not important do not try to fill exactly to a line! 3. Read the volume of the beaker to the correct number of significant figures. Use volume and mass to calculate the density of water. Density using a Graduated Cylinder 4. Record the mass of a dry 100 ml graduated cylinder to the correct number of significant figures. 5. Fill the graduated cylinder roughly 2/3 full with deionized water and record the mass. The amount of water is not important do not try to fill exactly to a line! 6. Read the volume of the graduated cylinder to the correct number of significant figures. Use volume and mass to calculate the density of water. 7. Find the percent error from the actual density of water (1.00 g/ml) for each of the two measurements. Percent Error = actual value your experimental value actual value x 100% Waste Disposal deionized water sink sodium chloride return to the jar used weigh boat regular waste

CHM111 Lab - Density and Measurements Grading Rubric Name Team Name Criteria Points possible Points earned Lab Performance Printed lab handout and rubric was brought to lab 3 Safety and proper waste disposal procedures observed 2 Followed procedure correctly without depending too much on instructor or lab partner 3 Work space and glassware was cleaned up 1 Lab Report Data was recorded with correct units and significant figures 2 Calculations are correct; work is shown in detail with units. 4 Post Lab: Question 1 1 Post Lab: Question 2 (0.50 points each) 2 Post Lab: Question 3 (work shown clearly with units) 2 Total 20 Subject to additional penalties at the discretion of the instructor

Density and Measurements: Data Sheet Name: Include the proper units for all measurements and show all your work for any calculations. Report your answer to the correct number of significant digits. A. Measuring Mass Mass of weigh boat 1 Mass of weigh boat 2 Mass of sodium chloride If you forget to zero a weigh boat, can you just subtract the mass of different weigh boat? Explain below. B. Measuring Volume Cylinder type Volume represented by smallest markings instrument should read to the nearest 10 ml 0.1 ml 0.01 ml Record the volume of water to the correct sig figs 100 ml 250 ml 500 ml Buret C. Determining the Density of a Metal Block Mass of metal block Value of smallest markings on ruler Ruler should be read to the nearest Length of block Width of block Height of block Did you remember to indicate units in all data entries? Report Page 1 of 3

Density and Measurements: Data Sheet 1. Calculate the volume of the metal block in cm 3. 2. Calculate the density of the metal block. Did you remember to show work and round to the correct number of significant figures in the questions 1 & 2? 3. Based on the table on in the lab instructions, what metal is your block? D. Determining the Density of Water Mass of empty glassware Mass of glassware with water Mass of water Volume of water (think about sig figs!) Density of water % Error Beaker Graduated cylinder 4. Show work below for density and percent error calculations. Always show all work with units. Beaker Graduated cylinder Report Page 2 of 3

Density and Measurements: Post Lab Questions Name Q1. Which density measurement did you expect to have the smaller percent error, the beaker the graduated cylinder? Explain your reasoning below. Did your results match your prediction? Q2. Read the following instruments to the correct number of significant figures. 10.1 ml 10.0 ml Q3. A cube of Brass (density 8.74 g/cm 3 ) has a mass of 87.321 grams. Determine the height of the cube in inches. Report Page 3 of 3