Flat roof drainage 1

Similar documents
Gas Pressure Regulator HON 200

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Horizontal Bladder Tanks

Pressure Reducing Valve DMV 750 set range: bar

Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

EnerVal. Technical data litre storage capacity. Buffer storage vessels

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Expert Hydrostatic Level Transmitters

KSB Delta Compact Type Series Booklet

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Monitoring device NTS 30

Armatures for analytical probes

KSB Delta Compact Type Series Booklet

High-performance submersible pressure transmitter For level measurement Model LH-10

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

OPERATING INSTRUCTIONS

Order No Projection Backboard

Liquid level instruments BM 24 /BM 51

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Float operated valve TYPE (SWDS)

Thanks for choosing EJAI SOLAR product

ASSEMBLY INSTRUCTIONS S O L O N STANDARD MODULES

10.2. Basketball Single Post System

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Technical Data Sheet T 2025

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Tightness controls TC 1 3 and TC 4

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Features. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

Instruction Manual Contact Pressure Vacuum Gauge

10.2. Basketball Single Post System

Remeha Quinta Cascade guide

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

How to specify a product. Process Sensors and Mechanical Instruments

INSTRUCTION MANUAL Pressure Relief Device LPT

Liquid level switch BM 34

4/2 way Pneumatic Solenoid Valve

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Manual Power relay SR853

Type 4708 Supply Pressure Regulator

GA24 Technical Datasheet

Differential pressure controls, Type MP 54, 55 and 55A

deltaflowc deltaflowc Venturi or Probe

776 Cryogenic Safety Valve

USER MANUAL. Beach volleyball posts BEACH CHAMP ID:

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

Differential pressure

Installation and Operating Instructions Bypass Flow Meter DST

FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable!

Mass Flow Controller (MFC) for Gases

Outlet Structures T-12

Instruction Manual Differential Pressure Transmitter

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

DiaSafe. Systems. Ballasted Fall Protection. DiaSafe Ballasted Single Solo DiaSafe Ballasted Single Duo DiaSafe Ballasted Line Multi. w w w.diadem.

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S06*

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Mass Flow Controller (MFC) for Gases

CR Series. Special doors for clean room application

Type 4708 Supply Pressure Regulator

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

RA-N radiator valves with integrated presetting and self-sealing tailpiece

VA40 - VA45 Technical Datasheet

Dual position solenoid valve Type ICSH 25-80

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Compact pressure switches for gas and air

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

SIHI LPH-X - Liquid Ring Compressors

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Technical Data - Pressure Losses profi-air Heat-recovery ventilation

50Hz. water solutions. O SerieS DGO DRO

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

High-performance submersible pressure transmitter For level measurement Model LH-10

Tightness control TC. Product brochure GB 3 Edition AGA

Pressure Transmitter P41

Safety Relief Valve HON 832

VENTILATOR OPTIONS. Please visit our web page to view all the available options and for a specification.

ELADOS EDP L Diaphragm Metering Pump Type

Actuator HON 670 / 671

Barcol-Air BRM Radiant Module

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

GENO -Flushing Compressor Product Data Sheet F 02

3M Telecommunications Solutions for Networks. Quante QSA (= LSA plus) System Catalogue. Innovation

Transcription:

Flat roof drainage 1

F Ü R D I E ZU K U N FT G E DAC HT. alwitra waterproofing system Flat roof drainage systems are part of the proven alwitra waterproofing system. This system comprises: 1 Waterproofing membranes Roof edge trim profiles 2 incl. colour coating 2 11 Wall capping profiles 3 3 incl. colour coating 4 4 10 9 incl. colour coating 5 5 Colour coating 6 Coated metal sheets 7 1 6 8 Wall flashing profiles 8 7 9 10 Snow guard profiles Daylight systems Flat roof drainage Flat roof vents 11 Paving slab supports Contents The new alwitra roof drainage system... 4 Accessories for alwitra rainwater outlets... 12 Dimensioning principles for roof drainage systems... 5 alwitra refurbishment rainwater outlets... 13 alwitra rainwater outlets... 68 alwitra water spouts... 1516 alwitra extension pieces... 9 Drainage rates... 17 alwitra emergency outlets... 10 Overview of alwitra rainwater and emergency outlets... 1819 alwitra terrace grate... 11 2

alwitra rainwater and emergency outlets alwitra rainwater outlet S 125/110 with extension piece 3

F Ü R D I E ZU K U N FT G E DAC HT. Ready for the next deluge the new alwitra roof drainage system The new alwitra roof drainage system When planning and installing drain age systems on low slope roofs, the requirements of various standards and guidelines are generally binding. In particular, DIN EN 12056 and DIN 1986100 include specific requirements for roof drainage and emergency drainage systems. The new alwitra roof drainage system is the perfect solution for all drainage issues of low slope roofs. The new alwitra roof drainage system is adapted to the specific requirements for rainwater and emergency outlets of low slope roofs (EnEV, DIN 1986100) extremely efficient: Optimised inlet geometry providing both a high discharge rate and a low ponding height. extremely tough: Made of highly impact resistant polypropylene (PP). comprehensive: A vast product range offering numerous combination possibilities with a small number of individual parts. 4 flexible: Along with the alwitra waterproofing membranes EVALON and EVALASTIC, almost any vapour control sheets can be professionally and securely flashed against. safe: The entire system has been testified by TÜV Rheinland LGA Products GmbH according to DIN EN 1253 and bears the German conformity mark Ü.

Dimensioning principles for roof drainage systems General notes (excerpts from relevant standards and guidelines): place, whether it is adequately sized and properly arranged. At concrete constructed roofs with designed and statically proven rainwater retention, there is no need for an emergency Roof drainage: drainage system. Dimensioning of roof drainage systems has to be done by way Gravel or green roof, usually, means less rainwater outlets, of hydraulic calculation. A medium rain event, the so called the number of emergency outlets or overflows, however, will local design rainfall (r(5,5))* is used as a dimensioning basis, increase compared to roof areas without ballast. taking into consideration cost effectiveness and selfcleaning capacity. At least one flat roof rainwater outlet must be installed at Calculation: every low point, depending on slope, as well as on every The required discharge rate Q(5,5) [L/s] of the design rainfall (r(5,5)) separate roof area, depending on the roof geometry. at a projected roof area A [m²] and a drainage coefficient C for the Roof and emergency drainage systems, in total, must be capable of discharging a 5 minute centennial rainfall (r(5,100))* to roof drainage is calculated as follows: Q(5,5) = r(5,5) C A 1 / 10,000 be expected at the location of the building. The distance between the individual rainwater outlets As regards emergency drainage, this leads to a minimum di installed at practically the same height level should not scharge rate Qemerg. [L/s] of exceed 20m. Qemerg. = (r(5,100) r(5,5) C) A 1/10,000 Emergency drainage: * Reference locations see Appendix 1 to DIN 1986100 or KostraDWD of the German Weather Service (DWD) Each individual roof area must have an emergency drainage system. Emergency drainage can be done by emergency overflows (e.g. water spouts) or emergency outlets. At least one flat roof rainwater outlet must be installed at every low point, depending on slope. From every flat roof rainwater outlet, unimpeded discharge to an emergency outlet with sufficient discharge capacity must be ensured on the roof waterproofing. In any case, the emergency drainage system must be capable of discharging the difference volume between centennial rainfall (r(5,100))* and design rainfall (r(5,5))*. The water has to be freely discharged to an area not prone to flooding. In order to avoid any damage, this water must not be discharged to other roof areas, roof terraces or e.g. to areas near lowground entrances to garages, basements etc. In the case of refurbishment, the discharge capacity of the existing drainage system needs to be verified. Furthermore, it must be verified whether an emergency drainage is in 5

F Ü R D I E ZU K U N FT G E DAC HT. alwitra rainwater outlet vertical (S 125/110 and SH 125/110 for DN 125 and DN 100) The thermally insulated alwitra rainwater outlet S (vertical) waterproof connection is easily established between the roof made of highly impact resistant polypropylene (PP) provides waterproofing and the rainwater outlet. the connection between vertical drainage pipes and the waterproofing at cold or inverted roofs. Thus, pipes DN 125 (OD 125 On classic warm roofs, instead of the roof waterproofing, all mm) can be connected directly, pipes DN 100 (OD 110 mm) using standard vapour barriers can be flashed in the same way. Ther the included reducer 125/110. Corresponding reducers/adapters mal insulation layers can be bridged by an extension piece. are optionally available for drainage pipes DN 70 (OD 75 mm) or Extension pieces are available in various lengths (see chapter DN 150 (OD 160 mm). So, every rainwater outlet fits four different alwitra extension pieces 200, 400, SL ). diameters (DN 70, DN 100, DN 125 and DN 150). An electrically heatable version, 230 V AC, is optionally available (see chapter Heatable alwitra rainwater outlets ). Flashing against the roof waterproofing is carried out with a special screw ring. In combination with an oval gasket and a A combined leaf guard/gravel stop is included. corresponding connecting flange, a reliable and longterm cutout. alwitra rainwater outlet vertical alwitra rainwater outlet S 125/110 Technical data of alwitra rainwater outlet S 125/110 Class (leaf guard/gravel stop): H 1.5 Ø of screw holes in flange: 240 mm Outlet: vertical Flange width: approx. 50 mm highly impact resistant PP Connection diameter: 125 mm (DN 125) and 110 mm black (optional connecting (DN 100); 75 mm (DN 70) with flange in the colour of the optional reducer; 160 mm waterproofing membrane) (DN 150) with optional adapter Required roof opening: Ø 200 mm (Ø 190 mm possible) Outer diameter of optional Height: approx. 190 mm (approx. connecting flange: 480 mm 275 mm incl. installed reducer) Discharge rates: see table p. 17 Outer diameter flange: 290 mm Number of screw holes in flange: 6 4

alwitra rainwater outlet horizontal (W 75/110 and WH 75/110 for DN 70 and DN 100 as well as W 125 and WH 125 for DN 125) The thermally insulated alwitra rainwater outlet W (horizontal) connecting flange, a reliable and longterm waterproof connec made of highly impact resistant polypropylene (PP) provides the tion is easily established between the roof waterproofing and connection between horizontally installed drainage pipes and the rainwater outlet. the waterproofing on cold or inverted roofs. It is available in two different sizes: On classic warm roofs, instead of the roof waterproofing, all standard vapour barriers can be flashed in the same way. Ther W 125 for connecting to pipes DN 125 (OD 125 mm) mal insulation layers can be bridged by an extension piece. W 75/110 with small overall height for connecting to pipes Extension pieces are available in various lengths (see chapter DN 70 (OD 75 mm) and with included adapter 75/110 to pipes alwitra extension pieces 200, 400, SL ). DN 100 (OD 110 mm) Electrically heatable versions, 230 V AC, are optionally available (see chapter Heatable alwitra rainwater outlets ). As with all rainwater outlets and extension pieces, flashing against the roof waterproofing is carried out with a special screw A combined leaf guard/gravel stop is included. cutout installation depth cutout pipeline installation depth ring. In combination with an oval gasket and a corresponding cutout alwitra rainwater outlet horizontal alwitra rainwater outlet W 75/110 Technical data of alwitra rainwater outlet W 75/110 and WH 75/110 for DN 70 and DN 100 as well as W 125 and WH 125 for DN 125 Class (leaf guard/gravel stop): H 1.5 Number of screw holes Outlet: horizontal in flange: highly impact resistant PP Ø of screw holes in flange: 240 mm black (optional connecting flange Flange width: Required roof opening: Min. installation height: approx. 50 mm in the colour of the waterproofing Connection diameter: W 125 125 mm (DN 125) membrane) W 75/110 75 mm (DN 70) W 125 190 x 280 mm W 75/110 190 x 250 mm W 125 approx. 200 mm Outer diameter of optional W 75/110 approx. 110 mm connecting flange: 480 mm Discharge rates: see table p. 17 Outer diameter of flange: 3 110 mm (DN 100) with included adapter 75/110 290 mm 7

F Ü R D I E ZU K U N FT G E DAC HT. Heatable alwitra rainwater outlets alwitra rainwater outlets are optionally available with electrical For controlling, an energysaving thermostat with an outdoor heating (230 V AC). The letter H in the name indicates the temperature sensor is used, activating the heating only when heating feature of the outlet. required. This is done at two adjustable switching thresholds. The thermostat is activated at the critical temperature range At the factory, the heating system is integrated into the rainwater just above freezing point. Thus, energy is consumed only when outlets, consisting of a silicone heating mat protected against actually necessary. overheating by a builtin temperature switch. Irrespective of the number of heatable rainwater outlets Connection to 230 V AC power supply is carried out with a installed, only one thermostat is required installation depth installation depth thermostat without using transformers or the like. cutout cutout Heatable alwitra rainwater outlet horizontal Heatable alwitra rainwater outlet WH 75/110 Technical data of the heating Technical data of the thermostat Operating voltage: 230 V AC, ±10 %, 50 60 Hz Mounting: Power: 10 VA Protection class: II Operating voltage: 230 V AC, ±10 %, 50 60 Hz Degree of protection: IP54 Power consumption: 3 VA Connecting cable: silicone, twocore, Temperature range HIGH : +10 C / 0 C length approx. 100 cm Temperature range LOW : 0 / 15 C DIN rail mounting with external outdoor temperature sensor Output relay: 16 A changeover contact 250 V AC (ohmic load) Protection class: II Degree of enclosure protection: IP20 IP54 outdoor temperature sensor 8

alwitra extension pieces 200, 400, SL The alwitra extension pieces are used for bridging thermal alwitra extension pieces are made of highly impact resistant insulation layers of warm roofs and are available in three polypropylene (PP). As with alwitra rainwater outlets, flashing lengths, depending on the thermal insulation layer thickness: against the roof waterproofing is carried out with a special screw ring. alwitra extension pieces are compatible with all alwitra rainwater outlets and provide backflowproof connection by extension piece 200 for thermal insulation layer thicknesses from 50 200 mm simply inserting them into the rainwater outlet. When used in combination with alwitra rainwater outlet S or SH, the extension extension piece 400 for thermal insulation layer thicknesses from 50 400 mm piece usually requires no cutting to length. extension piece SL individual length according to customer specification For waterproofing membranes EVALON or EVALASTIC, a corresponding connecting flange is already included. cutout cutout alwitra extension piece alwitra extension piece 400 Technical data of the alwitra extension piece highly impact resistant PP Outer diameter black (connecting flange in the Flange: 290 mm colour of the waterproofing Flange width: approx. 50 mm membrane) Connection diameter: approx. 120 mm (fitting all Min. installation height: approx. 35 mm Max. installation height: 200: approx. 200 mm thermal Outer diameter of insulation thickness connecting flange: 480 mm 400: approx. 400 mm thermal Discharge rates: see table p. 17 alwitra rainwater outlets) insulation thickness SL: according to customer specification 9

F Ü R D I E ZU K U N FT G E DAC HT. alwitra emergency outlets According to the requirements stipulated in DIN 1986100, outlet socket 40 can be achieved by cutting to length on site. emergency drainage systems are mandatory for flat roofs with To this end, the extension pieces are marked (grooves) at internal drainage. This applies also to refurbishment. intervals of 10 mm. The emergency outlet socket 100 can be adjusted to a ponding height of 20 100 mm. To meet these requirements, alwitra rainwater outlets and extension pieces are designed as to be easily converted into For the SL version, pieces are delivered readytoinstall for a emergency outlets with a specified ponding height. ponding height of 20 100 mm according to customer specification. The required emergency outlet sockets are available in three different versions and vary only in the potential ponding height: A ponding height of 20 40 mm at the emergency alwitra emergency outlet socket alwitra emergency outlet socket 40, mounted to alwitra rainwater outlet S 125/110 Technical data of the emergency outlet socket highly impact resistant PP Outer diameter of black optional connecting flange: 480 mm Min. ponding height: 20 mm Discharge rates: Max. ponding height: 40: approx. 40 mm 100: approx. 100 mm SL: according to customer specification preadjusted from 20 100 mm 10 see table p. 17

alwitra terrace grate Combined with the heightadjustable alwitra terrace grate made For installation heights > 90 mm, additional lift rings are of stainless aluminium, all alwitra rainwater outlets can be optionally available, providing for additional height of installed on used roof areas with waterproofing (e.g. roof terraces). approx. 36 mm per ring. The grate is installed in place of the leaf guard/gravel stop, The alwitra terrace grate is the ideal complement for roof areas ensuring drainage at paving and waterproofing level. covered with paving slabs installed on the proven alwitra paving slab supports PA 20 plus. By turning the lift ring, the installation height (overall height of the paving above the waterproofing) is adjustable from approx. 67 90 mm in steps of 3 mm. alwitra terrace grate alwitra terrace grate on alwitra rainwater outlet W 75/110 Technical Data of the alwitra terrace grate Class: K3 aluminium, with locating ring in steps of 3 mm (without made of polypropylene (PP) additional lift ring) Installation height: approx. 67 90 mm, adjustable aluminium Additional height per Dimensions approx. 195 x 195 mm (for an optional lift ring: approx. 36 mm opening of 200 x 200 mm) Discharge rates: see table p. 17 11

F Ü R D I E ZU K U N FT G E DAC HT. Accessories for alwitra rainwater outlets Numerous optional accessories are available to complement the drainage system of alwitra rainwater/emergency outlets. 12 alwitra extension piece UKD 200 and UKD 400 for inverted roofs alwitra screwing aid for secure installation of the screw ring alwitra reducers/adapters alwitra base plate/refurbishment plate alwitra bellows alwitra connecting flange

alwitra refurbishment rainwater outlets In the case of refurbishment with additional thermal insulation, where it is not possible to replace existing outlets, it is recommended to install alwitra refurbishment rainwater outlets. Using the customfit refurbishment plate (DN 125 made of PP, DN 100 and DN 70 made of aluminium), which is flashed against the existing waterproofing without back flow, reliable installation of the refurbishment piece is guaranteed. Flashing against the new waterproofing is carried out either with connecting flange and screw ring (refurbishment rainwater outlet 125) or with factoryfitted connecting flange (refurbishment rainwater outlet 75, 110). alwitra refurbishment rainwater outlet 125 alwitra refurbishment rainwater outlet 125 alwitra refurbishment rainwater outlet 75 and 110 Technical Data for alwitra refurbishment rainwater outlet Technical Data for alwitra refurbishment rainwater outlet 125 (EVALON / EVALASTIC ) 75 and 110 (EVALON ) PVC grey highly impact resistant PP Min. thickness of additional insulation: approx. 50 mm Max. thickness of additional insulation: Min. thickness of additional insulation: approx. 200 mm Outer diameter of flange: 290 mm Flange width: approx. 50 mm approx. 10 mm Max. thickness of additional insulation: approx. 300 mm Connecting flange: factory welded, in the colour of the Outer diameter of waterproofing membrane connecting flange: 480 mm 75: 180 x 180 mm Refurbishment plate: PP black 110: 230 x 230 mm Discharge rates: see table p. 17 Refurbishment plate: aluminium Discharge rates: see table p. 17 13

F Ü R D I E ZU K U N FT G E DAC HT. alwitra water spouts alwitra water spout SW rectangular 100/300 14

alwitra water spouts As an emergency overflow, alwitra water spouts are part of the alwitra roof and emergency drainage system for nonused or extensive green roof areas covered with EVALON waterproofing membranes. They can be installed horizontally through the parapet. alwitra water spouts are made of rigid PVC and, depending on the version, are equipped either with a welding flange for EVALON waterproofing membranes or with a factoryfitted connecting flange made of EVALON. Along with the alwitra water spouts for pipes with various diameters, rectangular versions are also available. These rectangular water spouts feature particularly high discharge rates at low ponding heights. The discharge rates are indicated in the table at p. 17 alwitra water spout S Technical Data for alwitra water spout S with connecting flange without base plate, as emergency overflow with open outlet, Base plate with standard DN pipe sizes, for EVALON roof waterproofings rigid PVC, impact resistant, UV stabilised Pipe dimensions: DN 50 (OD 50 mm), DN 70 (OD 75 mm), DN 100 (OD 110 mm) Pipe length: 500 mm Connecting flange: EVALON 1.5 mm pipe iron grey (~ RAL 7011); connecting flange white, light grey, slate grey Technical Data for alwitra water spout SF with connecting flange and base plate, as emergency overflow with open outlet, with standard DN pipe sizes, Base plate for EVALON roof waterproofings rigid PVC, impact resistant, UV stabilised Pipe dimensions: DN 50 (OD 50 mm), DN 70 (OD 75 mm), DN 100 (OD 110 mm), DN 125 (OD 125 mm), DN 150 (OD 160 mm) Pipe length: 500 mm Connecting flange: EVALON 1.5 mm pipe iron grey (~ RAL 7011); connecting flange white, light grey, slate grey 15

F Ü R D I E ZU K U N FT G E DAC HT. alwitra water spouts Technical Data for alwitra water spout SW with angled flange and connecting flange, EVALON as emergency overflow with open outlet, Base plate with standard DN pipe sizes, for EVALON roof waterproofings rigid PVC, impact resistant, UV stabilised Pipe dimensions: DN 50 (OD 50 mm), DN 70 (OD 75 mm), DN 100 (OD 110 mm) Pipe length: 400 mm Connecting flange: EVALON 1.5 mm pipe iron grey (~ RAL 7011); connecting flange white, light grey, slate grey Technical Data for alwitra water spout SF rectangular with rigid PVC welding flange, as emergency overflow with open outlet, ) 00 1,0 0( 50 with rectangular pipe crosssections, for EVALON roof waterproofings rigid PVC, impact resistant, UV stabilised Pipe dimensions: 100 x 300 mm, 100 x 500 mm Pipe length: 500 mm, 1,000 mm, according to 500 or 1,000 customer specification up to 1,000 mm Connecting flange: EVALON 1.5 mm pipe iron grey (~ RAL 7011); Optional: connecting flange white, light grey, slate grey Technical Data for alwitra water spout SW rectangular with angled flange and connecting flange, as emergency overflow with open outlet, ) 00 1,0 0( 50 with rectangular pipe crosssections, rigid PVC, impact resistant, UV stabilised Pipe dimensions: 100 x 300 mm, 100 x 500 mm Pipe length: 500 mm, 1,000 mm, according to customer specification up to 1,000 mm Ponding height: factoryadjusted ponding height from 20 45 mm according to customer specification pipe iron grey (~ RAL 7011); connecting flange white, light grey, slate grey 16 nn ect ing fla ng e connecting flange co ponding height from 20 45 mm according to customer specification for EVALON roof waterproofings 500 or 1,000

Discharge rates Rainwater outlets, emergency outlets, refurbishment rainwater outlets, water spouts Ponding height [mm] 10 mm 15 mm 25 mm 35 mm 1.50 L/s 2.30 L/s 4.10 L/s 6.90 L/s 9.20 L/s vertical DN 70 1.60 L/s 2.50 L/s 4.50 L/s 7.50 L/s 10.20 L/s vertical DN 70, with extension piece 0.50 L/s 1.20 L/s 2.30 L/s 4.10 L/s 5.40 L/s 1.65 L/s 2.60 L/s 4.50 L/s 7.00 L/s 9.10 L/s 5 mm 45 mm vertical DN 70, with terrace grate DN 70 (OD 75) vertical DN 70, as emergency outlet 1.50 L/s 2.30 L/s 4.00 L/s 6.90 L/s 9.20 L/s vertical DN 100 1.50 L/s 2.30 L/s 4.30 L/s 7.50 L/s 8.30 L/s vertical DN 100, with extension piece 1.70 L/s 2.70 L/s 4.60 L/s 7.50 L/s 8.30 L/s vertical DN 100, with terrace grate 1.65 L/s 2.60 L/s 4.40 L/s 7.20 L/s 9.60 L/s vertical DN 100, as emergency outlet 1.45 L/s 2.20 L/s 3.90 L/s 6.90 L/s 9.20 L/s vertical DN 125 1.45 L/s 2.20 L/s 3.90 L/s 7.00 L/s 9.60 L/s vertical DN 125, with extension piece 1.70 L/s 2.70 L/s 4.60 L/s 7.00 L/s 8.30 L/s vertical DN 125, with terrace grate 1.60 L/s 2.50 L/s 4.40 L/s 7.20 L/s 6.90 L/s vertical DN 125, as emergency outlet vertical DN 150 1.50 L/s 2.30 L/s 3.90 L/s 6.69 L/s 9.30 L/s 1.60 L/s 2.50 L/s 4.50 L/s 7.30 L/s 10.00 L/s vertical DN 150, with extension piece 1.70 L/s 2.70 L/s 4.60 L/s 7.00 L/s 8.30 L/s vertical DN 150, with terrace grate 1.65 L/s 2.60 L/s 4.80 L/s 7.30 L/s 9.60 L/s vertical DN 150, as emergency outlet 0.60 L/s 1.45 L/s 2.30 L/s 3.10 L/s 6.47 L/s 8.82 L/s horizontal DN 70 1.70 L/s 2.70 L/s 4.30 L/s 7.40 L/s 10.00 L/s horizontal DN 70, with extension piece 0.46 L/s 1.15 L/s 2.30 L/s 4.10 L/s 5.35 L/s 5.68 L/s horizontal DN 70, with terrace grate 0.60 L/s 1.60 L/s 2.60 L/s 4.50 L/s 7.00 L/s 9.10 L/s horizontal DN 70, as emergency outlet 0.60 L/s 1.30 L/s 2.00 L/s 3.80 L/s 5.20 L/s 6.13 L/s horizontal DN 100 0.50 L/s 1.40 L/s 2.30 L/s 4.10 L/s 6.00 L/s 6.20 L/s horizontal DN 100, with extension piece 0.60 L/s 1.50 L/s 2.50 L/s 3.64 L/s 4.79 L/s 5.01 L/s horizontal DN 100, with terrace grate 1.65 L/s 2.60 L/s 4.40 L/s 7.20 L/s 9.60 L/s horizontal DN 100, as emergency outlet 0.50 L/s 1.40 L/s 2.30 L/s 4.20 L/s 6.80 L/s 9.88 L/s horizontal DN 125 0.60 L/s 1.50 L/s 2.40 L/s 4.40 L/s 7.20 L/s 9.60 L/s horizontal DN 125, with extension piece 0.60 L/s 1.50 L/s 2.50 L/s 3.94 L/s 4.81 L/s 5.01 L/s horizontal DN 125, with terrace grate 0.50 L/s 1.45 L/s 2.40 L/s 4.40 L/s 7.20 L/s 9.20 L/s horizontal DN 125, as emergency outlet 0.50 L/s 0.83 L/s 1.15 L/s 2.40 L/s 4.25 L/s 6.80 L/s refurbishment vertical DN 70 0.30 L/s 1.00 L/s 1.70 L/s 3.50 L/s 5.60 L/s 7.90 L/s refurbishment vertical DN 100 1.45 L/s 2.20 L/s 3.90 L/s 7.00 L/s 9.60 L/s refurbishment vertical DN 125 0.03 L/s 0.06 L/s 0.09 L/s 0.23 L/s 0.43 L/s 0.63 L/s water spout S DN 50 0.05 L/s 0.10 L/s 0.16 L/s 0.35 L/s 0.62 L/s 0.93 L/s water spout S DN 70 0.06 L/s 0.13 L/s 0.21 L/s 0.65 L/s 0.83 L/s 1.26 L/s water spout S DN 100 0.22 L/s 0.37 L/s 0.11 L/s 0.30 L/s 0.55 L/s 0.85 L/s water spout SF 70 0.14 L/s 0.39 L/s 0.74 L/s 1.17 L/s water spout SF 100 0.15 L/s 0.42 L/s 0.79 L/s 1.26 L/s water spout SF 125 0.18 L/s 0.48 L/s 0.93 L/s 1.49 L/s water spout SF 150 0.22 L/s 0.37 L/s water spout SW 50 0.11 L/s 0.30 L/s 0.55 L/s 0.85 L/s water spout SW 70 0.14 L/s 0.39 L/s 0.74 L/s 1.17 L/s water spout SW 100 0.37 L/s 0.74 L/s 1.14 L/s 2.02 L/s 3.13 L/s 4.42 L/s water spout SF rectangular 100/3001 0.55 L/s 1.10 L/s 1.90 L/s 3.59 L/s 5.43 L/s 7.67 L/s water spout SF rectangular 100/5001 0.37 L/s 0.74 L/s 1.14 L/s 2.02 L/s 3.13 L/s 4.42 L/s water spout SW rectangular 100/3001 0.55 L/s 1.10 L/s 1.90 L/s 3.59 L/s 5.43 L/s 7.67 L/s water spout SW rectangular 100/5001 DN 100 (OD 110) vertical S and SH DN 125 (OD 125) DN 150 (OD 160) DN 70 (OD 75) DN 100 (OD 110) horizontal W and WH DN 125 (OD 125) refurbishment water spout SF 50 All discharge rates in litres/second [l/s] with leaf guard/gravel stop or wired domed leaf guard installed No rate determined emergency overflows (water spouts) 1 Open inlet 17

F Ü R D I E ZU K U N FT G E DAC HT. Overview of alwitra rainwater and emergency outlets Vertical outlet also available with heating 230 V AC DN 70 (OD 75) DN 100 / DN 125 (OD 100 / OD 125) DN 150 (OD 160) S 110/125, SH 110/125 S 110/125, SH 110/125 S 110/125, SH 110/125 DN 125 (OD 125) + reducer 125/75 DN 125 (OD 125) incl. reducer to DN 100 (OD 110) DN 125 (OD 125) + adapter 125/160 Extension pieces (fitting all alwitra rainwater outlets) Extension piece 200 Extension piece 400 for thermal insulation thicknesses from 50 200 mm for thermal insulation thicknesses from 50 400 mm Extension piece SL for thermal insulation thicknesses according to customer specification Connecting flange (fitting all alwitra rainwater outlets and extension pieces) Connecting flange EVALON light grey Connecting flange EVALON white Connecting flange EVALON slate grey Thickness 1.5 mm, Ø 480 mm Thickness 1.5 mm, Ø 480 mm Thickness 1.5 mm, Ø 480 mm Accessories (fitting all alwitra rainwater outlets and extension pieces) Emergency outlet 40 Emergency outlet 100 Emergency outlet SL for extending all alwitra rainwater outlets and extension pieces with a ponding height of 20 40 mm for extending all alwitra rainwater outlets and extension pieces with a ponding height of 20 100 mm for extending all alwitra rainwater outlets and extension pieces with a ponding height according to customer specification 18

Horizontal outlet also available with heating 230 V AC DN 70 / DN 100 (OD 75 / OD 110) DN 125 (OD 125) W 75/110, WH 75/110 W 125, WH 125 DN 70 (OD 75) incl. adapter to DN 100 (OD 110) DN 125 (OD 125) Extension pieces UKD 200 Extension pieces UKD 400 for thermal insulation thicknesses at inverted roofs from 50 200 mm for thermal insulation thicknesses at inverted roofs from 200 400 mm Connecting flange EVALON various colours (on request) Connecting flange EVALASTIC grey Thickness 1.5 mm, Ø 480 mm Thickness 1.5 mm, Ø 480 mm Terrace grate made of aluminium, heightadjustable 19

F Ü R D I E ZU K U N FT G E DAC HT. alwitra GmbH & Co. PO Box 3950. D54229 Trier Germany Member of 03/2015 Phone: +49 651 91020 Fax: +49 651 9102248 export@alwitra.de. www.alwitra.de 20 Technical changes reserved