PRESSURE DROP CHARTS

Similar documents
Balancing Valves. Applications/ Features: Ordering Information: Accessories:

This loop is filled with an antifreeze solution such

LABORATORY EXERCISE 1 CONTROL VALVE CHARACTERISTICS

CONTINENTAL NH3 PRODUCTS PRODUCT CATALOG

MANUAL FLOW CONTROL 2-1/2" - 18" QUICKSET FLOW CHART

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems.

SIZING AND CAPACITIES OF GAS PIPING

MEMORIAL UNIVERSITY OF NEWFOUNDLAND Faculty of Engineering and Applied Science FLUID MECHANICS LABORATORY PIPE FRICTION

Application Worksheet

SIZING AND CAPACITIES OF GAS PIPING

Basic layout 2016 IRRIGATION-MART. Check (Non- Leak) Valve. Friction Fit. Sprinkler. Figure 1 - Hanging Sprinkler & Check Valve Assembly

PX4 P L A S T I C PX4 PERFORMANCE WIL T-02

PX800 M E T A L PX800 PERFORMANCE WIL T-08

SIZING THE EXTROL DIAPHRAGM-TYPE HYDRO-PNEUMATIC TANK

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

TECHNICAL DATA. Q= Cv S

Hydronic Systems Balance

TECHNICAL DATA. Q = C v P S

SIZING AND CAPACITIES OF GAS PIPING Reserved

Equivalent Length of Fittings

SIZING AND CAPACITIES OF GAS PIPING

HYDRAULIC CONTROL VALVES

then the work done is, if the force and the displacement are in opposite directions, then the work done is.

SG TF. Q = 963 Cv (P1 - P2)(P1 + P2) TECHNICAL INFORMATION. Flow Q (GPM)

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

SIZING AND CAPACITIES OF GAS PIPING

TECHNICAL DATA Q= C. Table 1 - Specifications

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

SIZING OF WATER PIPING SYSTEM

ENGINEERING DATA. Engineering Data

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

TECHNICAL DATA OBSOLETE

SIZING THE WELL-X-TROL

APRIL Flawlessly moving water to provide the ultimate in comfort, safety and convenience for residential and commercial applications.

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Wirsbo / AquaPEX. AquaPEX Tube. White Coils. White Straight Lengths. Wirsbo AquaPEX plus Tubing. Red Coils. Blue Coils PAGE 055-1

SIZING OF WATER PIPING SYSTEM

ACCESSORY KIT INSTALLATION INSTRUCTIONS

TECHNICAL DATA. Q = C v P S

Models 106-RF / 206-RF Rate of Flow Control Valve

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

ART24 Differential Pressure Control Valve (DPCV)

PX400 P L A S T I C PX400 PERFORMANCE WIL T-02

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

ACCESSORY KIT INSTALLATION INSTRUCTIONS

3-way control valves VK 3

VB-7263 Series. Application. Features. Applicable Literature

Engineering Information. Flow Data. Flow Data. Importance of Valve Sizing. Estimating Cv or Orifice Size:

V311. Venta. Three-way Plug Valve, Flanged PN 16

The Hoffman Specialty Series 2000 consists of main

VB-7273 Series. Application. Features. Applicable Literature

SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER

PX1 PX1 PERFORMANCE M E T A L WIL T-12

Product Catalogue. February We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping

Bell & Gossett ESP-Systemwize Pump Selections

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

TECHNICAL DATA. Q = C v P S

Geothermal Alliance of Illinois Non-Pressurized Flow Centers

SCREEN OPENINGS FOR STRAINERS

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

TECHNICAL DATA. Q = C v P S

Product Catalogue. July We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping

HERZ - Compact Flow Controller with

TECHNICAL DATA. Q = C v P S

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD.

TECHNICAL DATA. Q = C v P S

Product Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

Application Notes for Valve Sizing Sizing valves for steam service with the aid of sizing charts

Maximum Weight of Racks* P67 P90 P120 P140 P160 P180 3,800# 4,400# 5,500# 6,100# 7,000# 7,900#

Cavitation in Valves

A t. VB-7323 Series. Application. Features. Applicable Literature. l/2 to 2 Screwed NPT SIEBE

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

Process Dynamics, Operations, and Control Lecture Notes - 20

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

VBS-9263 Series. Application. Features. Applicable Literature

Dean Pump Self-Priming Chemical Process Pumps

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters

PRODUCTION I (PP 414) ANALYSIS OF MAXIMUM STABLE RATE AND CHOKES RESOLVE OF OIL WELLS JOSE RODRIGUEZ CRUZADO JOHAN CHAVEZ BERNAL

HERZ - Compact Flow Controller with

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM CHART A 1.2 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS CHART A-1 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

WaterSource Heat Pump Hose Kit Performance Specification-Summary

EN00 Pre-Instructional Survey

Fermilab MTF Cryogenic System & Vertical RF Cavity Test Facility. Yuenian Huang, on behalf of Fermilab, TD/TID May 11, 2006

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Mass Split of Two-Phase-Flow

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

The Coach then sorts the 25 players into separate teams and positions

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

VB Series. Application. Features. Applicable Literature. 1/2 to l-1/4 Union End NPT Stem Up Open, Two-Way Valves General Ins tructions

PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS INSTALLATION MANUAL CONTROL VALVES

Back to Basics: Pumping Systems RM ASHRAE TECH CONFERENCE

PLEASE NOTE: Pressures for 200mm (8ins) and 250mm (10ins) are based on the use of METALFLEX Braided Braid

ACCESSORY KIT INSTALLATION MANUAL

Grangeville Country Club Golf Course

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

Transcription:

PRESSURE DROP FOR SMALL PEX TUBING AT 100 F Take the total heat load (BTUH) for the area that the loop is covering and divide it by 501. Divide the result with the Delta-T to find GPM for the loop. Find the closest flow for the loop in the left GPM column of the chart. Move to the right to the correct pipe size intersecting line. Move down to read to read the pressure drop per 10 feet of pipe. Divide the loop length by 10, then multiply the result with the given pressure drop for 10 feet to get the total pressure drop for the loop. NOTE: This chart is for 100% water, and only includes the pressure drop for the PEX pipe itself. You need to add the drop for other equipment. For the manifold, add about 2 ft/hd. If glycol is used, use the correction charts on pages 92 93. 1-800-716-3406 87

PRESSURE DROP FOR LARGE PEX TUBING AT 100 F Find the closest flow for the loop in the left GPM column of the chart. Step 2, Move to the right to the correct pipe size intersecting line. Step 3, Move down to read to read the pressure drop per 10 feet of pipe. Step 4, Divide the pipe length by 10, then multiply the result with the given pressure drop for 10 feet to get the total pressure drop for the pipe length. NOTE: This chart is for 100% water, and only includes the pressure drop for the PEX pipe itself. You need to add the drop for other equipment. If glycol is used, use the correction charts on pages 92 93. 88 MRPEXSYSTEMS.COM

PRESSURE DROP FOR PAP TUBING AT 100 F Take the total heat load (BTUH) for the area that the loop is covering and divide it by 501. Step 2, Divide the result with the Delta-T to find GPM for the loop. Step 3, Find the closest flow for the loop in the left GPM column of the chart. Step 4, Move to the right to the correct pipe size intersecting line. Step 5, Move down to read to read the pressure drop per 10 feet of pipe. Step 5, Divide the loop length by 10, then multiply the result with the given pressure drop for 10 feet to get the total pressure drop for the loop. NOTE: This chart is for 100% water, and only includes the pressure drop for the PAP pipe itself. You need to add the drop for other equipment. For the manifold, add about 2 ft/ hd. If glycol is used, use the correction charts on pages 92 93. 1-800-716-3406 89

PRESSURE DROP FOR COPPER TUBING AT 100 F Find the closest flow for the loop in the left GPM column of the chart. Step 2, Move to the right to the correct pipe size intersecting line. Step 3, Move down to read to read the pressure drop per 10 feet of pipe. Step 4, Divide the pipe length by 10, then multiply the result with the given pressure drop for 10 feet to get the total pressure drop for the pipe length. NOTE: This chart is for 100% water, and only includes the pressure drop for the copper pipe itself. You need to add the drop for other equipment. If glycol is used, use the correction charts on pages 92 93. 90 MRPEXSYSTEMS.COM

C V VALUES The pressure drop for hydronic heating components are normally described by their Cv value. The Cv value describes at what flow (in gpm) the pressure drop over the component will be 1 psi (equal to 2.31 ft/hd). Check with the manufacturer for the Cv value of the component and then use formula below to establish the head loss (ft/hd). HEAD LOSS (FT.HD.) OVER VALVES ETC.: (1.52 x GPM / Cv)2 (GPM is the flow, and Cv is the valve parameter) (Multiply the flow by 1.52 and then divide by the Cv value. Multiply the result by itself) 1-800-716-3406 91

PRESSURE HEAD CORRECTION FACTOR FOR TEMPERATURES AND PROPYLENE GLYCOL Pressure head correction factor (multiplier) as a function of average fluid temperature ( F) and propylene glycol concentration (Volume %). Using the Chart: Find the average water temperature to the left Move horizontally to the right until the intersection with actual glycol concentration Go down vertically and read the flow correction factor Multiply the head loss (ft/hd) with the correction factor for correct result 92 MRPEXSYSTEMS.COM

FLOW CORRECTION FACTOR FOR TEMPERATURES AND PROPYLENE GLYCOL Flow correction factor (multiplier) as a function of average fluid temperature ( F) and propylene glycol concentration (Volume %). Using the Chart: Find the average water temperature to the left Move horizontally to the right until the intersection with actual glycol concentration Go down vertically and read the flow correction factor Multiply the flow (GPM) with the correction factor for correct result 1-800-716-3406 93