SUPERIOR RESULTS WITH UNIQUE FEATURES

Similar documents
Major Design Features

Determining Free-Space Values for ASAP Series Micropore Analyses

ASAP Accelerated Surface Area and Porosimetry System. Operator s Manual V3.03

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Standard Operating Procedure Porosity Analyzer - The Micromeritics Tri-Star II (surface area) with Micrometrics VacPrep 061 (Sample Degas System)

QUADRASORBevo surface area & pore size analyzer

TECH TIP 14. Minimum Surface Area Measurements with Micromeritics Physisorption Analyzers

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Preinstallation Checklist and Instructions for the TriStar These Preinstallation Checklist and Instructions were reviewed and approved by:

Document Number: 302/34000/76 SV/sv Revision: (B) 2009/02/05

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

11/22/ (4) Harmonization: <846> SPECIFIC SURFACE AREA

Discovery TGA 55, TGA 550, TGA Site Preparation Guide

Discovery HP-TGA 75/750. Site Preparation Guide

Document Number: 239/34000/76 Revision: (-) 2009-Apr-13

Series Environmental Chambers

HumiSys HF High Flow RH Generator

HP1/HP2. isorbtm ISOTHERMS PCT CURVES HEATS OF ADSORPTON. isorb HP1 / HP2. High Pressure Gas Sorption Analyzer. Catalysts. Ceramics. Energy.

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

Discovery SDT 650. Site Preparation Guide. Revision G Issued December Page 1

Frazier Permability Tester & Average Fiber Diameter Analyzer. Permeability measurement according to ISO: 4003 & ASTM D standard

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Digital Vacuum Regulator

LUMAZOTE T ECHNICAL BRO CHU RE

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Customer Responsibilities

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Bubble Point / Pressure Decay Test / Gas Transport Rates through Membranes

Customer Responsibilities

Oxidation Stability of Gasoline and Aviation Fuels

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

The University of Hong Kong Department of Physics Experimental Physics Laboratory

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Customer Responsibilities

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

Quick Start Guide for SA-9600 Series Surface Area Analyzer

Chapter 8: Cryo-sorption pumps

Customer Responsibilities

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Complete Range of Force Tensiometers

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

628 Differential Pressure Decay Leak Tester

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

DELTI. Vac. DELTI-Vac MIL. Application. Principle. Characteristic

VT650. Gas Flow Analyzer. Technical data. Key benefits and features:

Low gas volume & flow measurements made easier Gas Endeavour

PMI Pulse Decay Permeameter for Shale Rock Characterization Yang Yu, Scientist Porous Materials Inc., 20 Dutch Mill Road, Ithaca NY 14850

Customer Responsibilities

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

TA Instruments Installation Requirements for the Thermal Discovery Series

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Constant Pressure Inlet (CCN) Operator Manual

Product Calibration Procedure for the ASAP 2020 APPROVALS:

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices


FPG8601 Force Balanced Piston Gauge

Sartorius CCL kg Prototype Mass Comparator

LEAP CO 2 Laboratory CO 2 mixtures test facility

Generating Calibration Gas Standards

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Mass Flow Controller (MFC) for Gases

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003

POROMETER 3G POROMETER. through-pore size analyzer. Membranes. Filters. Non-Woven. Textiles. Papers. Ceramics. Sintered Metals SERIES

Applied Technology and Best Practices in CEE. Conference

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Sorbent Pen Heavy & Labile SVOC s Taints, Off-Flavors, Odors

The New PHD 4 Portable Helium Detector

General Specifications

Pneumatic high-pressure controller Model CPC7000

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Flow Vision I MX Gas Blending Station

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

ISO INTERNATIONAL STANDARD

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

Drilling Efficiency Utilizing Coriolis Flow Technology

Mass Flow Meter (MFM) for Gases

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

BETTER SAMPLE CARE. Spark Holland introduces. SPH1299 UHPLC Gradient Pump

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Residual Gas Analysis Systems for Industry

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements

Chapter 22 Testing Protocols

Spindles AISI 316 stainless steel spindles, easily identified by number and letter when changed according to range of viscosity.

APPLICATION NOTE. GC Integrated Permeation Device

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Leak Checking Large Vacuum Chambers

Pneumatic high-pressure controller Model CPC7000

Rimage Everest 600 Thermal Retransfer Printer

HPFM GEN3 - High Pressure Flow Meter

490 Micro GC Site Preparation Checklist

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST

Transcription:

Gemini VII 2390

SUPERIOR RESULTS WITH UNIQUE FEATURES Gemini VII 2390 Series Surface Area Analyzers Rapid and Precise Surface Area Analysis Surface area and pore volume are important physical properties that influence the quality and utility of many materials and products. Therefore, it is critically important that these characteristics be accurately determined and controlled. Likewise, knowledge of surface area and pore volume, often is an important key in understanding the formation, structure, and potential application of many natural materials. Micromeritics Gemini VII 2390 Series of surface area analyzers rapidly and reliably produces accurate and repeatable surface area and pore volume results. Their low cost, speed, simplicity of use, reliability, and ruggedness have earned the Gemini a place in laboratories worldwide as an essential tool in research and quality control environments. Unique Features The clear advantage of the Gemini s capabilities lie in its unique and innovative design which makes for not only a reliable and accurate instrument but also offers an easy to use operating system with intuitive reporting. Innovation: Gemini utilizes a unique adaptive rate dosing algorithm and is a special case of the static volumetric technique. Speed and sensitivity are unsurpassed by other static volumetric instruments. Accuracy: Micromeritics invented the balance tube design, which negates freespace errors introduced by thermal gradient variations or by initial mismeasurement of free space. The Gemini permits low surface area measurements without requiring krypton and the use of a servo valve controls the rate of gas flow into the sample tube to accurately attain target pressures without pressure overshoot. Faster Results: The sample controls the rate at which the gas is delivered thus accelerating delivery of the analysis gas. This results in a surface area analyzer that is as fast as the physics of adsorption allows. How-to videos provide on-screen instruction on instrument operation reducing training time for new users. Easy-to- follow installation videos and system verification tests ensure optimum performance and reliability. Flexibility: Three choices of software control: Embedded software allows for operation without an external PC through the keypad Windows 7 or greater operating system Gemini VII Confirm 21 CFR Part 11 option for regulated pharmaceutical applications

Three Model Options Gemini VII 2390a The Gemini VII 2390a model is ideal for rapid and accurate surface area determinations by single-point and multipoint BET and Langmuir methods. In addition, it provides standard methods for total micropore volume using the t-plot method. Included in this model s capabilities is the ability to determine statistical thickness surface area (STSA) of carbon blacks. (Refer to ASTM D 6556, ISO/DIS 18852.2, or ISO/CD 4652-2/3.) Gemini VII 2390p The Gemini VII 2390p model provides additional precision with the addition of a saturation pressure (P 0 ) tube that allows the system to monitor the saturation pressure of the adsorptive on a continuous basis during an analysis using a dedicated pressure transducer. This design feature permits a rapid measurement of the adsorption isotherm to near-saturation, as well as determination of pore size distribution. Gemini VII 2390t The Gemini VII 2390t model has all of the facilities of the 2390p with the addition of a larger dewar and longer sample tubes for extended analysis times. This provides the additional capability to measure the complete adsorption-desorption isotherm and perform pore size distribution measurements by BJH or DH using up to 1000 data points. Unique Design: The Gemini Technique Vacuum Adsorptive Helium A- Two gas reservoirs are filled with equal volumes of the desired adsorptive, usually nitrogen. From the reservoirs, gas is metered into the sample tube by way of a servo valve (F) that reacts to the rate of adsorption. Isothermal Block Differential Balance Transducer A C D B F A Quantity Adsorbed Differential Transducer A third pressure transducer (D) monitors the pressure between the two reservoirs to determine the differential quantity of gas, the difference being the quantity that is adsorbed on the sample Transducer (B) detects any pressure difference between the two tubes and causes another servo valve (C) to adjust the pressure within the balance tube to negate any pressure differential. Balance Tube Liquid Nitrogen E Sample Pressure Transducer Sample Tube E- A transducer monitors pressure within the sample tube causing a fast response servo valve (F) to increase or restrict the flow of gas to the sample tube as necessary to maintain a constant equilibrium pressure within the sample tube as adsorption occurs.

Superior Data Presentation Capability Operating Software Gemini analyzers can be operated from a keypad by way of embedded software or from a computer using the more-powerful and versatile Gemini Windows optional software. The embedded software includes: System verification tests Single- and Multipoint BET (Brunauer, Emmett, and Teller) surface area Langmuir surface area Total pore volume Total micropore volume and area by the t-plot method using Halsey, Harkins-Jura, or Carbon Black STSA thickness curves Horvath-Kawazoe for micropore distribution BJH pore size distribution using adsorption isotherm (Gemini 2390p and 2390t only) BJH adsorption and desorption isotherm, 1000 data points (Gemini 2390t only). Optional Gemini Windows Software The easy-to-use Gemini Windows 7 interface enhances the capabilities to plan, launch, and control the analysis. You can collect, organize, archive and reduce raw data, and store standardized sample information and analysis conditions for easy access during later applications. Finished reports may be generated to screen, paper, or to files in various formats. Features include cut-and-paste graphics and tables, scalable-and-editable graphs, and customizable report formats. Using computer control, you can operate up to four Gemini analyzers simultaneously from a single computer. Gemini Windows Features Gemini Windows software provides additional features not included with the embedded software. Features such as: Installation and how-to videos Reduction of user-entered data Automatically generated pressure tables with user-selected endpoints Storage of all historical sample data for retrieval User-defined pressure table Summary report Sample log Isotherm plot overlays Autoscaling x- and y-axes Cut-and-paste graphics and tables Data export to ASCII and spreadsheet formats User-defined thickness curve (manually entered or from data file) Fixed pore size tables Linear and log plots (isotherm, pore volume, pore area) Cumulative and differential data Broekhoff-de Boer thickness curve 21 CFR Part 11 Option Also available is Confirm software, which addresses the many requirements specified by 21 CFR Part 11 validation, security, audit trails, reporting, and more. Micromeritics Gas Adsorption Reports Windows software with all Micromeritics gas adsorption instruments contains the following reports: Isotherm Reports: tabular graphical pressure composition isotherm Isotherm modeling and surface area: BET Langmuir Temkin Freundlich Standard isotherm models: t-plot: micropore volume, micropore area, external surface area alpha-s method f-ratio method Classic models for mesopore volume, area, and distribution: BJH * Dollimore-Heal * Classic models for micropore distribution: Dubinin-Radushkevich and Astakhov Horvath-Kawazoe Saito-Foley Cheng-Yang MP method Density Functional Theory for pore size modeling: Slit-shaped pores using N 2, Ar, or CO 2 Cylindrical pores for alkalineexchanged zeolites using N 2 or Ar Cylindrical pores for hydrogen or ammonium-exchanged zeolites using N 2 or Ar Windows-shaped model for pillared clay Density Functional Theory for surface energy: Surface area and energy distributions using nitrogen at 77 K Surface area and energy distributions using argon at 87 K *BJH and Dollimore-Heal require the Gemini VII 2390t to take full advantage of pore size reports based upon the desorption isotherm

The Gemini VII 2390p includes a dedicated transducer for continuously monitoring the saturation pressure of the cryogenic bath. This allows the Gemini VII 2390p to rapidly measure adsorption isotherms and determine the pore volume, area, and size distribution of mesoporous materials. The Gemini VII 2390 Series analyzers provide rapid surface area analysis. The unique balanced design allows BET surface area to be measured using nitrogen for a broad range of materials. The Gemini offers precise measurements of low surface area materials using nitrogen. The determination of micropore volume, micropore surface area, and external surface area is available on all Gemini models using the standard t-plot calculations. The Gemini VII 2390t features extended operation to facilitate the determination of the total isotherm. Both adsorption and desorption measurements may be obtained; this allows users the capability to determine the pore volume, area, and size distributions using BJH or Dollimore-Heal reports.

Accessories Sample Preparation Devices Micromeritics offers numerous sample preparation devices for surface area and pore volume analysis. These devices combine flowing gas and/or vacuum with heat to remove atmospheric contaminants, such as water vapor and adsorbed gas, from the surface and pores of the sample. The quality of the data produced by surface area and pore volume analyses depends greatly on the cleanliness of the sample surface. All of Micromeritics sample preparation devices accept He, N 2, Ar, and other non-corrosive gases. Smart Prep 065 VacPrep 061 The SmartPrep 065 is a flowing-gas degassing unit which removes adsorbed contaminants from the surface and pores of your sample in preparation for analysis. It contains six sample ports, each one independently temperaturecontrolled for greater flexibility. It contains two serial ports, one for connecting to the computer and the other available for connection of an additional SmartPrep. The temperature, ramp rates, and soak times of each sample are individually controlled by the computer. Up to five ramps and soaks are allowed. All degas information is integrated into the sample data file for easy reference in the future. The FlowPrep 060 applies both heat and a stream of inert gas to the sample. The heat causes contaminants to desorb from the surface and the stream of inert gas sweeps them out of the sample tube. The unit lets you choose the temperature, gas, and flow rate best suited for your sample material and application. Needle valves allow you to introduce the flowing gas slowly to prevent fluidization of samples. The VacPrep 061 offers two methods for removing contaminants. In addition to flowing gas, it enables vacuum to be applied to prepare samples by heating and evacuation. This combination allows you to choose the preparation method that is best suited to your material or application. The VacPrep features six degassing stations, and a choice of vacuum or gas flow preparation on each of the six stations. Needle valves are also provided allowing you to introduce slowly the flowing gas or vacuum to prevent fluidization of samples. The Smart VacPrep 067 is an advanced six-port system that utilizes vacuum to prepare samples by heating and evacuation. Each of the ports may be operated independently. Samples may be added or removed from degas ports without disturbing the treatment of other samples undergoing preparation. Degassing automatically terminates when the samples have completed all programmed steps. Model 021 LN 2 Transfer System The Model 021 LN 2 Transfer System allows you to transfer liquid nitrogen or liquid argon from a non-pressurized storage dewar into smaller containers used in laboratory experiments. Additional accessories are available for special applications. Contact Micromeritics Sales Department for details. For more comprehensive information on the Gemini VII Series, visit our web site at www.micromeritics.com. FlowPrep 060 Smart VacPrep 067 Model 021 LN 2 Transfer System

Specifications Applicability Surface Area Pore Volume 4 x 10-6 cm³/g From 0.1 m², total; From 0.01 m²/g, specific Pressure Measurement Pressure Measurement Range P/Po Resolution <10-4 Relative Pressure Range Pressure Resolution Accuracy and Linearity (transducer manufacturer s specification) 0 to 950 mm Hg 0 to 1.0 P/P 0 (adsorption only) <0.1 mmhg Better than ± 0.5% Full Scale Environment Gases Temperature Humidity Adsorbate 10 to 35 C (50 to 96 F) operating; 0 to 50 C (32 to 122 F) non-operating 20% to 80% relative, non-condensing Optimized for nitrogen in a liquid nitrogen sample bath; Gemini may be used with non-corrosive adsorbate gases having vapor pressures at both room and bath temperatures that are acceptably high relative to the resolution of the 1000-mmHg pressure transducer. Typically, oxygen, argon, carbon dioxide, butane, methane, and other light hydrocarbons will produce useful data above absolute pressures of a few mmhg. Helium inlet also provided Vacuum System Vacuum source achieving 20 x 10-3 mmhg (or better) at the instrument inlet; having a device to reduce oil vapor backstreaming is recommended. The system must have an anti-suckback valve to prevent oil from being admitted into the Gemini should there be a power failure. Sample Tube/Dewar Standard Tube Dewar Gemini VII 2390a and 2390p: 0.95 cm (3/8 in.) outside diameter by 15.5 cm (6.1 in) with 6.5 cm³ of volume. Sample capacity is approximately 2.0 cm³ Gemini VII 2390t: 0.95 cm (3/8 in) outside diameter by 20.5 cm (8.1 in.) with 8.9 cm³ of volume. Sample capacity is approximately 2.0 cm³ ~ 8 hours; Gemini VII 2390a and 2390p; ~ 24 hours; Gemini VII 2390t Electrical Voltage Frequency Power 85 to 265 VAC 50/60 Hz 150 VA, operating, max. plus vacuum pump Computer Hardware and Software Minimum Requirements Windows 7 Professional or higher operating system Memory: 512 megabytes of RAM Hard Disk Space: 20 gigabytes One CD ROM drive Monitor: 1024 x 768 display capability Ethernet port (capable of communicating with a 10 base-t card) Physical Height Width Depth Weight 59 cm (23 in); Gemini VII 2390a and 2390p; 74 cm (29 in); Gemini VII 2390t 40 cm (16 in) 51 cm (20 in) 32 kg (70 lbs); Gemini VII 2390a and 2390p; 35 kg (78 lbs); Gemini VII 2390t *Due to continuous improvements, specifications are subject to change without notice.

Micromeritics Instrument Corporation 4356 Communications Drive, Norcross, GA 30093 USA To request a quote or additional product information, visit micromeritics.com Contact your local Micromeritics sales representative or our Customer Service Department at 770-662-3636 All Rights Reserved 2016. Micromeritics Instrument Corporation. Norcross, Ga 30093. 770-662-3636. Printed in the USA. 239/42700/00