Manufacturer s Information

Similar documents
Technical Data Package

Dräger CPS 7800 Gas-Tight Suit

75 Years of Health and Safety Guidance

Operating Manual. 3S-R AirElite Full Face Mask Advantage AirElite Full Face Mask Advantage 4000 AirElite Full Face Mask. AirElite - Full Face Masks

MSA AUER SSR 90 [K60]

MSA AUER SSR 30/100 MSA AUER SSR 30/100 B

BRAKE WINCH RUP 503-[T/BT] EQUIPMENT FOR LIFTING LOADS. AT 053-[T/BT] xx

Type BBS-03, BBS-05, BBS-06, BBS-25

Installation & Operation Manual Proven Quality since 1892

SMA1060 INSTRUCTIONS FOR SELF INSPECTION SMA1061 MANUAL INFLATION SMA1062 AUTO INFLATION

Dräger CPS 7900 Gas-Tight Suit

Dräger WorkMaster Industry Gas-Tight Suit

SMA1500 Instructions for Self Inspection SMA MANUAL INFLATION SMA AUTO INFLATION

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

INSTRUCTION MANUAL. EEBD Emergency Escape Breathing Device OPERATION AND MAINTENANCE UNISCAPE 15 H. Mat. No / 04 Safety by

Pectoral Machine. User manual E S S E N T I A L S T R E N G T H

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

B.C.D. Buoyancy Compensator Device User Manual

OPERATING INSTRUCTIONS

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Operating Manual MSA SSR 30/100 / MSA SSR 30/100 B EN K/20/S. Order No /01. MSAsafety.com

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

DuPont Personal Protection Product Catalog

Dräger CPS 6900 Gas-Tight Suit

Operating and maintenance manual Filter and reducing station Series / 1.0

Dri-Line Mk3 Monnier Compressed Air Drain Trap

GTL Gas-Tight Suit Instructions for use

Selection, Care and Use of Chemical Protective Clothing. Jason Cole Director of R&D Kappler, Inc.

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

PERSONAL PROTECTIVE EQUIPMENT GUIDANCE

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

RESCUE LIFTING DEVICE RUP 503-[...] AT 053-[...] xx

Pressure relief valve

User Manual for the Application of Hose Assemblies for High-Pressure Water Jet Machines

NORTHERN DIVER WETSUIT MANUAL

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT:

Personal Protective Equipment (PPE) Hydrogen Fluoride Hydrofluoric Acid Solutions

Flowmeter. Original operating manual DFM

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Fire Escape Hood OPERATION AND INSTRUCTIONS

CREWFIT 165 SPORT. self care and maintenance manual

Checklist for care of Respirators

Eaton Filtration, LLC

Pressure relief valve

Turnout gear is comprised of boots, coat, pants, suspenders, hood, gloves, helmet, and SCBA Facepiece.

Technical Service Bulletin June 2015 TSB122.06

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Operating Instructions VETTER Industrial Lifting Bags 8 bar - Type IKV

ROLLGLISS TOP/R350. Safety and rescue system. Operating and Maintenance Instructions

Chemical protective suits User manual NEO

NORTHERN DIVER PFD MANUAL

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Instruction Manual Contact Pressure Vacuum Gauge

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Personal Protective Equipment. OSHA Office of Training and Education

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

PINE HILL FIRE DEPARTMENT

PVC Quick Drain Valve

Personal Protective Equipment

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Dräger CPS 7900 olive, beige NBC Suit

Dräger CPS 7800 Gas-Tight Suit

Dräger SPC 3700 with CVA 0700 Splash Suit and Vest

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

BIOSAFETY SELF AUDIT PRINCIPAL INVESTIGATOR/PERMIT HOLDER: CONTAINMENT LEVEL: 1 2 (Shaded) RISK GROUP: 1 2 AUDIT TO BE COMPLETED BY (DATE):

HAZWOPER 8-Hr Refresher Aug. 20, 2012

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Model VR6 System. Installation, Operation & Maintenance

Personal Protective Equipment

Personal Protective Equipment. OSHA Office of Training and Education 1

ASSOCIATED DOCUMENTS:

A short guide to the Personal Protective Equipment at Work Regulations 1992

PNEUMATIC STOPPERS OPERATING MANUAL. Type F G H - FOG

Personal Protection Equipment (PPE)

Personal Protective Equipment. Protecting Employees from Workplace Hazards. Engineering Controls (cont d) Examples...

Johnston Invar Coupling Johnston Invar Coupling

Eaton Filtration, LLC

SE-shield. User instructions. Tychem F Single-Use Suit and Hood. Personal protective ensemble

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Personal Protective Equipment. OSHA Standard 29 CFR

Rescue Services Life Raft Manual

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual

User Guide for. UTR Turbo Air Lappers Pneumatic Air Grinders & Lappers UTR-30, UTR-70, UR , ,

Instruction Manual AC350 GUIDED-TYPE FALL ARRESTER ON RIGID ANCHORAGE LINE EN 353-1:2002

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

MSD901. Industrial Dry Suit User's Manual

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

SPECIFICATION FOR ONESuit Pro NFPA 1991, 2005 ED. CERTIFIED VAPOR PROTECTIVE ENSEMBLE NFPA 1994 CLASS 2, 2007 ED. CERTIFIED FIRST RESPONDER ENSEMBLE

Maintenance handbook

INDUSTRIAL HOSES - steam

Installation, Operating & Maintenance Instructions. All-metal gate valve with extended pneumatic actuator. Series 48 DN mm (I.D.

University of Vermont Department of Physical Plant Personal Protective Equipment Program

Pressure Relief Valve DHV 718

Table Of Contents. General Information Pg 1 Limitations & Warnings Pg 1. Pre-checking the Air Supplied Gas Tight Suit Pg 2

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Transcription:

Manufacturer s Information Manufacturer: Pflüger GmbH Havelstr. 28 24539 Neumuenster Germany Tel: +49 (0) 4321-8974 Fax: +49 (0) 4321-82494 Mail: pflueger@pfluegerhp.de Chemprotector -Divetex - Berlin 1b Type - EN 943-1 : 2002 with GL certificate Product: Protection Suit Material: Divetex EN 943-1 : 2002 Product No.: 0032 Color: bright yellow, Red Page 1 of 12

Contents 1 Wearing instructions... 3 2 Before usage... 3 3 How to put on the Protective Suit...4 4 How to take off the Protective Suit... 4 5 Maintenance...5 5.1 Cleaning...5 5.2 Disinfection...5 5.3 Service...5 5.4 Leak Test...6 5.5 Test timelines...6 5.6 Repairs...6 6 Exchange of parts... 6 6.1 Exchange of gloves...6 6.2 Exchange of boots...7 7 Transportation and storage...8 8 Technical data...9 8.1 Technical data Chemprotector -Divetex Berlin 1 b Type......9 8.2 Material specifications...9 8.3 Resistance to permeation i.r.o. EN 374-3...10 8.4 Sizes i.r.o. EN 340...11 8.5 Spare parts/options...11 8.6 Unsuitability...11 9 Warning notices...11 10 Disposal... 12 11 Certifying institute... 12 12 Administrative institute... 12 Page 2 of 12

1 Wearing instructions The Chemprotector Divetex Berlin 1b Type is a gas-proof protective suit to be used while being exposed to toxic chemicals. It offers temporary protection to skin and respiratory tracts when working with harmful liquid chemicals (sodium hydroxide solutions, hydrochloric acid, sulphur-containing acid). It is resistant against various chemicals which are to be found in item in 8.3 of this manual. It is protecting against all chemicals being examined only. In case of a chemical being not listed or in general uncertainty, please consult the manufacturer for clarification. All seams of the Chemprotector Divetex Berlin 1b Type protective suit are hot air welded with foil material being welded on the outer side in order to provide perfect protection against chemicals and mechanical stress. The gloves and boots are designed to be exchangeable. The gloves are made of butyl material as where the boots are manufactured in accordance with EN 345 standard. Its fluid and gas-proof zipper is placed at the back, running from the head to the lower back. The Chemprotector Divetex Berlin 1 b Type protective suit must only be worn and/or deployed in combination with a full mask (incl. air filter) or a compressed air breathing device. It turned out, during the certifying tests and procedures, that the Auer 3S full face mask is to be considered the perfect replenishment of the Chemprotector Divetex Berlin 1 b Type protective suit. The maximum time of usage of the protective suit depends on the general operational conditions (full mask, filter or compressed air breathing device), the micro climate underneath the protection overall and the ambient air temperature. By operating in a low ambient air temperature, additional isolating underwear should be used. In case of danger, the contaminated area must be abandoned immediately. 2 Before usage Always before using the Chemprotector Divetex Berlin 1 b Type protective suit the user must visually inspect the suit and its accessories for suitability and correct functioning. The suit must be in good condition. Further, the suit has to be checked generally at regular basis. It must be checked regarding its impermeability and completeness attributes. Only a faultless protective suit can guarantee your safety. Leak-proof attributes of the protective suit should not only be tested after each cleaning, disinfection and exchange of individual parts, but also after longer storage periods - at least once every six months time. The impermeability test can be carried out by a visual check, with a seam test device or a commercially available leakage spray. Tears or holes in the suit s material must be sealed by the manufacturer only. Page 3 of 12

In case of doubt about its safety, the chemical protective suit may only be used after being tested by the manufacturer or an authorized expert. The suit, gloves, mask sealing and boots are also to be tested for holes or tears. The leak tightness attributes must be tested as described in per item 5.5. 3 How to put on the Protective Suit It could be beneficial if a second person assists while putting on the protective suit - Unpack the protective suit - Put on underwear - Step with your legs and/or boots (one leg and/or boot after the other) - Pull the protective suit up to the crotch - Put on the full face mask - Pull the sealing cap over the mask - Move into the left and the right sleeve - Fasten the zipper non-violently and gradually, whereby the link chains have to be connected by stretching, while the other hand pulls the bolt onto the loop upwards slowly - In order to expel excess air, it is recommendable to crouch down shortly before closing the protective suit completely - Put on compressed air device (see relevant instructions) or screw the breathing filter onto full face mask 4 How to take off the Protective Suit The user must leave the contaminated area after completion of work. In case of strong contamination, the suit must be pre-cleaned on the person wearing it after use. Water or, if necessary, suitable cleaning admixtures must be used. Make sure, that a possible helper is also wearing suitable personal protective clothing, e.g. protective gloves, breathing mask and protective suit or a protective sleeve apron. In order to remove the protective suit, proceed as it is described under Pos. 3 (How to put on the protective suit) but in reversed order. First, remove compressed air breathing apparatus and/or air filter. Then the zipper is opened by a helper and the mask sealing cap pulled off forwards over the head. After that, the entire suit is to be taken off at once. After removal, avoid contact with the contaminated outside of the suit. A protective suit that has to be cleaned or disinfected is transported from the operational area to the cleaning site in a suitable container (plastic bag, case, etc.) by observing the respective safety measures. Page 4 of 12

5 Maintenance 5.1 Cleaning Impermeability / tightness and completeness of the suit must be checked regularly. The tightness can be carried out both by the Porta Control tester or a commercial leak spray. The tightness of the suit must be checked after each cleaning, or after prolonged storage - at least once every six months. Punctures or holes may be repaired in accordance with professionally by the manufacturer. After the completion of the work or when leaving the contaminated area, the suit must be cleaned. For normal contamination of protective clothing can with a conventional Colored fabrics, not with bleaching effect (eg " Sanomat," effective disinfection KA -WE GmbH, phone +49 ( 0) 620 225 004, Fax +49 ( 0) 620 225 387 ) can be washed at 30 C in washing machine. Then open the suit is suspended from the boots. The protective clothing must not o with radiant heat on the radiator be tumble-dried. Recommended would be a drying cabinet. 5.2 Disinfection Depending on the conditions of use or before the protective clothing is used by another person as well as after being exposed to non-liquid contaminants the clothing should be disinfected with an appropriate disinfectant. Please obey the directions for the use of the disinfectant. Note: For hygienic reasons it is recommended that protective clothing is worn by one and the same person only. 5.3 Service As described previously, after each cleaning, disinfection or exchange of parts, the suit must undergo a pressure and leak test performed by using a leak tester for protective clothing. The zipper must be lubricated slightly with a grease pencil or suitable acid-free grease and operated after each cleaning or after a storage period of six-months. Page 5 of 12

General services intervals: - Before use: visual and leak testing. - After repairs: leak test. - After use: cleaning and disinfecting, visual control and leak test. - Semi annually: visual and leak testing. If the suit is still in the original packing, a test only needs to be done after a period of two years time. Note: A suit being strongly contaminated by aggressive chemicals must be withdrawn from use and returned to the manufacturer or an authorized expert repair workshop for testing and servicing. 5.4 Leak Test The protective suit is tested for leaks with a special leak test device. - Full mask seal with test adapter. - Inflate the protective suit to an overpressure of 19 mbar with clean, odorless compressed air. - Damping period of pressure approx. 3 minutes. - Drop the overpressure to 16 mbar test pressure. - Maximum admissible pressure drop within one minute is about 2 mbar. 5.5 Test timelines The protective suit must undergo a visual inspection and a leak test as per 5.3 above, every six months. In its original packing and in an unused state, a test needs only be carried out after two years time. At this opportunity, the zipper must be lubricated with acid-free grease. 5.6 Repairs Repairs on material and exchanging of zippers must only be carried out by the manufacturer. 6 Exchange of parts 6.1 Exchange of gloves a. Disassembly of gloves - Open the zipper completely. - Turn the sleeves of the protective suit inside out. - Unscrew the screw clamps Page 6 of 12

- Pull out the pipe piece. - Take the glove out of the sleeve. b. Assembly of gloves - Insert the pipe piece and the glove into the sleeve. - Adjust the glove. - Put the screw clamps on and tighten them. - The check the protective suit for being leak-proof. Caution: The cramp protection must cover the cramp lock! 6.2 Exchange of boots a. Disassembly of boots - Open the zipper completely. - Turn the legs of the protective suit inside out. - Unscrew and remove the screw clamps. - Pull out the pipe piece. - Take the boots out of the legs of the protective suit. b. Assembly of boots - Insert the boots into the legs of the protective suit. - Adjust the legs of the protective suit to the boots. - Insert the pipe piece into boot leg. - Put the screw clamps on and tighten them. - Then check the protective suit for being leak tight. Caution: The cramp protection must cover the cramp lock! For assembly of the gloves and boots, please see drawing on the upcoming page 8. Page 7 of 12

7 Transportation and storage The protective suit is folded and not under pressure during delivery and transportation. It must be stored in clean and dry conditions at room temperature, free of hazardous substances, protected against direct sunlight and heating. The suit must be stored ready for use in its cover or in a wardrobe in hanging position. When folding up the protective suit, make sure that neither the material nor the seams and the zipper are put under pressure. Page 8 of 12

8 Technical data 8.1 Technical data Chemprotector Divetex Berlin 1 b Type Temperature range: Overall weight: Interior leakage: Test aerosol: Zipper: -30º to +60ºC 6.9 kg (incl. gloves and boots) < 0.01% at eye region of full face mask NaCl Gas-proof, length: Gloves: EN 374 Boots: EN 345 Seams: Linking seam 8.2 Material specifications Colour: Material: Weight: Dimensional change i.r.o. ISO 5077 Red Divetex 580 gm/m2 Complies Abrasion resistance i.r.o. EN 530, Process 2: Performance level 6 Bending tear resistance i.r.o ISO 7854 Process B Performance level 6 Tear extension resistance i.r.o. ISO 9073-4 Performance level 5 Bursting resistance i.r.o. EN ISO 13938-1 Performance level 4 Penetration resistance i.r.o. EN 863 Performance level 2 Seam security i.r.o. EN ISO 13934-1 Performance level 5 Page 9 of 12

8.3 Resistance to permeation i.r.o. EN 14325 No. Chemical Breakthrough Class 1 Acetone >480 min 6 2 Acetonitrile 180 min 4 3 Dichlorometahne 380 min 5 4 Carbon disulphide 2,8 min - 5 Diethylamine 6,8 min - 6 Dimenthylformamid 33,4 min 1 7 Ethyl acetate 9,8 min - 8 N-hexane 20,5 min - 9 Methanol > 480 min 6 10 Nitrobenzene 29,8 min 1 11 Perchlorethylan 16,1 min 1 12 Tetrahydrofuran 8,4 min - 13 Toluene 9,6 min - 14 Sodium hydroxide 50 % 52,5 min 2 15 Sulfuric acid 95 % 49,4 min 2 16 Hydrochloric acid 60 % > 480 min 6 17 Chlorine 480 min 6 18 Ammonia 360 min 5 19 Hydrofluoric acid 73 % > 1440 min 6 20 Phosphorus trichloride > 1440 min 6 Class Penetration Time 1 >10 mins. 2 >30 mins. 3 >60 mins. 4 >120 mins. 5 >240 mins. 6 >480 mins. Page 10 of 12

8.4 Sizes i.r.o. EN 340 Size L: 54 56 Size XL: 58 60 8.5 Spare parts/options - Mask sealing - Gloves - Boots (EN345) - Rings - Inside Cuffs 8.6 Unsuitability The Chemprotector Divetex Berlin 1 b Type protective suit is not designed to be used for: - Sea rescue work - Fire-fighting (heat protection) - Working with chainsaws and other sharp devices 9 Warning notices - The Chemprotector -Divetex Berlin 1 b Type protective suit does not provide any protection in case of damages caused by mechanical nature, by stabs, chain saws, radioactive rays and fire. - It is mandatory to adhere the admissible permeation times as otherwise the wearer will be exposed to severe danger. - If other chemicals than those listed in the permeation list are used, please asked the manufacturer for approval. - The Chemprotector -Divetex Berlin 1 b Type protective suit provides sufficient protection only, when it is worn properly and all parts are attached as designated. - For environment temperatures below 5 C a thermal insulation is necessary. - We recommend not wearing the Chemprotector -Divetex Berlin 1b protective suit directly onto the skin. Page 11 of 12

10 Disposal The disposal of the Chemprotector -Divetex Berlin 1 b Type protective suit is to be conducted in accordance to official directives. 11 Certifying institute Centro Tessile Cotoniero e Abbigliamento S.p.A. Piazza S. Anna, 2 Busto Arsizio (VA) Italy CE 0624 12 Administrative institute Centro Tessile Cotoniero e Abbigliamento S.p.A. Piazza S. Anna, 2 Busto Arsizio (VA) Italy CE 0624 Page 12 of 12