FLOWTRON HYDROVEN 3. User Manual. Intermittent Pneumatic Compression System

Similar documents
POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

DYNAMIC COMPRESSION THERAPY

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

Paradise Pump Series Operator s Manual

Med Aire Alternating Pressure Pump and Pad System

Instruction Manual for Configura Cushionair Portable Pump

Intermittent Pneumatic Compression System

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

User manual. MNPG 102 Rev. 04 Edition 04/02/16. Pressotherapy model. Power-Q1000 Premium

FLOWTRON ACS800 +TRI PULSE INSTRUCTIONS FOR USE

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Alternating Pressure / Low Air Loss Mattress System

User manual. PG132 Rev01 Editi Compressive Limbs Therapy System DVT-7700

Pegasus Aircare Mattress Overlay System Models 2200 and 2201

Aneroid Sphygmomanometer. Use, Care, & Maintenance

SC505 Sof Care Inflator. Operating Instructions and Service Manual

General Warnings! A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately could lead

Customer Service See Service Provider Documentation

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

DYNAMIC COMPRESSION THERAPY

User manual. PG89 Rev 01 Editi Pressotherapy model. LymphoPress 4

USER MANUAL LTH-255A Hand Piece

OPERATING INSTRUCTIONS FOR USE GUIDE

Comfortmax Thermax Hot/Cold Water Circulation System. Instructions for Use

Model ASSEMBLY and OPERATING INSTRUCTIONS

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

CircuFlow TM 5150 Series

Key Product Features. Primary Use: Aggressive Treatment of Pressure Ulcers

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

User Manual DIRECTHEALTHCARESERVICES.CO.UK

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Air Plus User Manual

Contents. Introduction...1 About Breeze... 1 Breeze Overlay... 2 Breeze Mattress Replacement... 2 Breeze Pump... 4 Controls and Indicators...

Budget Range Operators Handbook

CircuFlow TM 5208 Series

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

NIMBUS range. with people in mind

AND OPERATION INSTRUCTIONS

APH166 Morpheus Air USER MANUAL. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

User Manual. 10. Dimensions and Ordering Codes. Integrity Alternating Pressure Mattress System. Alternating Pressure Mattress Systems

453 Series Steam Heated Vaporizing Regulator

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

SEQUENTIAL CIRCULATORS

CircuFlow 5200 Series

Operator s Manual. Dynamic Low-Air-Loss Therapy with Alternating Pressure

12 Chamber Pump & Garment System for Lymphoedema

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

Oxygen Dialflow Meter. Instructions for Use

Cavitron DualSelect. Introduction ENGLISH. Directions For Use. Cavitron DualSelect Dispensing System ENGLISH 1

CircuFlow Quick Setup Guide

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

Instructions for Cleaning & Maintaining Air Compressor

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Vevazz. Operation Manual. Vevazz, LLC Rancho California Road. Suite Temecula, CA Phone: (773) Fax: (888)

Stroller. Sprint S T R O L L E R S P R I N T

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

Dual Release Walkers 6291 Series. 1 General. 1 Dual Release Walkers. 1.1 Symbols WARNING

User s Guide. VetPro 1000 Mobile Dental Delivery System. For Models:

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

User Manual DIRECTHEALTHCARESERVICES.CO.UK

1 METRON MANIPULATION TABLES - WARRANTY STATEMENT

DUAL ACTION SANDER MODEL NO: CAT121 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0211

92831 TEL: (714) FAX:

Fingertip Pulse Oximeter

AKRON CHILDS TILT TABLE

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

Pressure Injection Cell Operator s Manual

OPERATOR S MANUAL HOTLINE 3 Blood and Fluid Warmer

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

MODEL 100 NITROGEN INFLATION CART

USER MANUAL. AirPal Air Supply. (AS-1100 North America) 1488 Limeport Pike, Coopersburg, PA airpal.com fax

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

Hi Flow Stroller H I F L O W S T R O L L E R

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Oxygen Dialflow Meter. Instructions for Use

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

TJF-Q180V Cleaning and Disinfection Checklist

INFUSION SYSTEM (110V) (220V) USER S MANUAL

MACS Mask CPAP System

92831 TEL: (714) FAX:

12V AIR STATION ALL-IN-ONE

77-I0PN230 Rev. A. Model 1030 User Manual

Norrsken Family Booklet

Model IC-BAP-DL BioArterial Plus

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

Regalia Oxygen Concentrator

Dialflow Regulator. Instructions for Use

ADC. Sphygmomanometer Accessories. Directions for Use, Care, & Maintenance AMERICAN DIAGNOSTIC CORPORATION

Operating Instructions Part No

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

Transcription:

FLOWTRON HYDROVEN 3 User Manual Intermittent Pneumatic Compression System

Contents Introduction......................................................... 1 Clinical Applications.................................................. 2 Indications......................................................... 2 Contraindications................................................... 2 Cautions.......................................................... 3 Warning........................................................... 3 Clinical Treatment Guide.............................................. 4 Garment and Insert Information........................................ 5 Garment Description................................................. 5 Selecting the Correct Garment......................................... 5 Applying the Garment................................................ 6 Garment with Insert.................................................. 7 Applying an Insert................................................... 7 Operation........................................................... 8 Pump Description................................................... 8 Operation......................................................... 9 Cleaning, Care, Maintenance, and Service............................... 10 System.......................................................... 10 Pump............................................................ 10 Garments and Washing............................................. 10 Troubleshooting.................................................... 12 Service Returns................................................... 12 Warranty........................................................... 13 Ordering Information................................................ 15 Garments........................................................ 15 Inserts........................................................... 16 Technical Description................................................ 17 (i)

(ii)

General Safety Before you connect the system pump to a main power supply, read carefully all the installation instructions in Section 4, Garment and Insert Information and Section 5, Operation. The system has been designed to comply with regulatory safety standards including UL60601-1 1st Edition, CAN/CSA C22.2 No 601.1-M90. Safety Warnings Electrical equipment may be hazardous if misused. The pump's rear case should only be removed by authorized technical personnel. Do not use the pump in the presence of flammable gases such as anesthetic agents. Precautions For your own safety and the safety of the equipment, always take the following precautions: Regularly check the system when in use for pump operation and garment fit. Keep the pump away from sources of liquids and do not immerse in water. Do not expose the system, especially the garments, to open flames, such as cigarettes, etc. Do not store the system in direct sunlight. Switch off the power supply to the pump by disconnecting the pump from the power outlet before cleaning and inspecting. Do not use phenol-based solutions to clean the system. Ensure the system is clean and dry prior to storage. Never use sharp objects on the system. Only the pump and garment/insert combination manufactured by Huntleigh Healthcare should be used. The correct functioning of the product cannot be guaranteed if the incorrect pump and garment combinations are used. (iii)

Caution Electromagnetic compatibility (EMC). This product complies with the requirements of applicable EMC Standards. The use of accessories not specified by the manufacturer may result in increased emissions by, or decreased immunity of, the equipment, affecting its performance (iv)

1. Introduction The Flowtron Hydroven 3 system is an intermittent pneumatic compression system designed to be used as part of a management program for the following clinical conditions: Dependent or traumatic edema Lymphedema in the upper or lower limbs Chronic venous insufficiency Post-phlebitic syndrome Acute and chronic wounds (including venous leg ulcers and post-surgical wounds) The system is comprised of a pump and either single or three chamber arm or leg garments. Optional garment inserts can be applied to increase the circumference of the standard arm and leg garments. The pump supplies air via connecting tubes to an inflatable garment allowing the application of controlled pressure to gently compress the limb. This action assists in increasing the return of blood, excess fluids, improves venous stasis and encourages the reabsorption of waste products. The pump operates on an automatically timed cycle of 3 minutes, 90 seconds inflation followed by 90 seconds deflation. Variable pressure output ranges from 30-100 mmhg. The garments are inflated alternately. The Flowtron Hydroven 3 system operates two types of garments: Hydroven 1 garments have a single chamber and provide uniform compression. Hydroven 3 garments have three chambers providing gradient segmental compression, inflating distally to proximally. We would recommend that this manual be read thoroughly before proceeding with treatment. 1

2. Clinical Applications Indications Intermittent pneumatic compression (IPC) is effective in the treatment of the following clinical conditions: Edema Dependent (including secondary to cerebrovascular incident, pregnancy or paralysis) Traumatic (post-surgical or post-injury) Lymphedema Primary and secondary (including post-surgery, radiation or chemotherapy) Chronic venous insufficiency Post-phlebitic syndrome Acute and chronic wounds, including venous leg ulcers and post-surgical wounds IPC may also be beneficial in the management of: Fixed flexion deformity Arthritic conditions Lower limb pain due to trauma or surgery Lipedema Contraindications IPC should NOT be used in the following circumstances: Known or suspected deep vein thrombosis (DVT), pulmonary embolism, thrombophlebitis Acute infections of the skin such as cellulitis Untreated, infected wounds Decompensated / severe congestive cardiac failure or pulmonary edema associated with significant limb edema, or any condition where an increase of fluid to the heart may be detrimental Severe arteriosclerosis or other ischemic vascular disease Active metastatic disease affecting the limb If you are uncertain whether you have any of the above conditions, please consult a physician before use. 2

Cautions Warning IPC should be used with care in patients with the following symptoms or conditions: Peripheral neuropathy, pain or numbness in the limb Undiagnosed, untreated or infected wounds, fragile skin, grafts or dermatological conditions that may be aggravated by the garment Extreme limb deformity which may practically impede the correct application of the garment Therapy should be interrupted and physician notified if pain, tingling or numbness of the limb occurs during, or as a result of therapy In the event of a power failure, or fault whereby the garment remains inflated, remove the garment Patients must not walk or stand when wearing leg garments 3

3. Clinical Treatment Guide An initial pressure setting of 40 mmhg is suggested at the commencement of treatment. It may be necessary to start at a lower level of pressure dependant on the patient s tolerance. The pressure can be gradually increased over time, until the required pressure is reached. The upper treatment pressure range is generally 60-70 mmhg. A single treatment session is usually 20-30 minutes. The above settings and timings are recommended guidelines, and should not be used as a substitute for clinical judgement and experience. 4

4. Garment and Insert Information Garment Description Zipper Ring Pull Quick Air Release Cap Zipper Ring Pull Tubing Connector (to Pump) Tubing Connector (to Pump) Garment Cap/Connector for Insert Tubing Garment Cap/Connector for Insert Tubing Hydroven 3 Garment Hydroven 1 Garment For Hydroven 1 garments, when an insert is not in use, the cap can be used as a quick air release. Selecting the Correct Garment 1. Select the type of garment depending on treatment type: Hydroven 1 garments have a single chamber and provide uniform compression. Hydroven 3 garments have three chambers providing gradient segmental compression, inflating distally to proximally. 2. Measure the circumference of the largest part of the limb, and the length in inches from the heel to the inseam of thigh for a full leg garment, heel to knee for half leg garment, from shoulder to finger tips for full arm garment, and from elbow to finger tips for half arm garment. Refer to Ordering Information on page 15 to order the correct size garment. Knee Circumference Shoulder Circumference Hand Circumference Half Leg Garment Full Arm Garment 5

Applying the Garment Quick air release bung Tubing to pump Tubing to pump Leg Garment Arm Garment Before fitting the garment ensure all quick air release caps are closed, as this will effect the efficiency of the garment. 1. Place the limb into the garment and zip up carefully, ensuring that the patient is in a comfortable position with the limb supported or elevated as necessary. If appropriate, a primary dressing or stockinet may be used underneath the garment(s) 2. Ensure that the zipper is fully secured at the top edge and that the quick air release caps are secured. 3. Attach the garment tubing to the pump ensuring a click is heard from each snap-lock connector. 4. If only one garment is to be used, attach the garment to either port on the pump. The system will automatically identify that only one garment is to be used. Ensure that the all zippers are fully closed on the garment before switching the pump on. 5. Switch on the pump and adjust the pressure control accordingly. Caution Do not apply or remove the garment while it is attached to the pump and while the pump is in operation, as you may damage the garment zipper. Do not stand or walk while leg garments are on. 6

Garment with Insert Zipper Ring Pull Insert Quick Air Release Cap Garment Tubing/Connector (to Pump) Applying an Insert Tubing (from Insert) If a larger circumference garment is required, a matching length insert may be used. Before applying the garment to the limb, zip the insert along the length of the garment, as shown. Check that the insert connecting tube is not kinked and is attached to the garment using the lower outlet cap as shown below. Leg Garment with Insert Fitted Arm Garment with Insert Fitted 7

5. Operation Pump Description 4 5 1 2 3 Flowtron Hydroven 3 Pump Control Number Description Function 1 On/Off Switch Operation of this switch starts or stops the system 2 Pressure Control Knob Rotates clockwise to increase and counterclockwise to decrease pressure (pressure range 30-100 mmhg) 3 Tube Connectors For garment attachment (snap-lock) 4 Pressure Gauge Indicates delivery pressure to garment (mmhg) 5 Carry Handle For easy handling of pump Caution Do not apply or remove the garment while it is attached to the pump and the pump is in operation, as you may damage the garment zip. 8

Operation Switch On To Set the Garment Pressure The pump should be placed securely on a flat surface. Before starting the pump ensure that the garments are properly applied, the zippers are secured and the garment connecting tubes are attached to the pump outlet ports via snap-lock connectors. Ensure that the pressure level is set at minimum (i.e. the knob (2) is fully rotated in a counterclockwise direction). Press the ON/OFF switch. While the garment is inflating, rotate the pressure control knob (2) slowly clockwise until the required pressure is displayed on the gauge (4). The garments will take approximately three cycles to fully inflate. Check and adjust as necessary after three inflation cycles. It might be necessary to start at a lower pressure level dependant on the patient s tolerance. Compression should not cause any discomfort or pain to the patient. To Remove the Garment Switch off the pump (1), disconnect the tubing from the pump by releasing the snap-lock connectors (3), and release the quick air release cap on the garment. Only open the zipper after the garment is completely deflated. 9

6. Cleaning, Care, Maintenance, and Service The following cleaning guidelines for the Flowtron Hydroven 3 system have been established in accordance with good infection control practice. Should you have any questions regarding cleaning or if you require further information please contact your Huntleigh Healthcare Service Department. WARNING Switch off the electrical supply to the pump and disconnect the power cord from the power supply before inspecting and cleaning. Protective clothing should always be worn when carrying out decontamination procedures. Caution Never use phenolic, hypocarbonate-based disinfectants containing cationic surfactants, ammonia-based compounds, or antiseptic solutions such as Steriscol or Hibiscrub. These will damage the surface coating. Do not spray cleaning solutions directly onto the pump. Avoid immersing electrical parts in water during the cleaning process. The pump cannot be sterilized. System Pump To Clean It is recommended that, where practicable, all parts of the system (pump, garments and tubing) should be cleaned weekly. Wipe down using a soft cloth dampened with a mild detergent. To Disinfect Garments and Washing To Clean After cleaning, wipe down with an EPA-approved, hospital grade disinfectant, as per an appropriate protocol. Wipe down using a neutral detergent or soap powder at 104 F (40 C). 10

Do not tumble dry. Do not iron. Do not dry clean. To Disinfect Do not machine wash. Do not immerse tubeset in water. Air dry thoroughly. After cleaning, wipe complete garment over using 70% isopropyl alcohol wipe or a chlorine-releasing agent at 1000 p.p.m. available chlorine. Do not use phenol or phenol-derivative disinfectant. To Sterilize Rinse with clean water to remove any residue. Air dry thoroughly. After cleaning, gas sterilization is possible. Do not exceed 120 F (51 C). Do not autoclave. 11

7. Troubleshooting If you should encounter a problem, please follow the fault finding guide below. If the fault cannot be rectified, please refer to Service. Fault Check Remedy Pump dead Pump operates but garment will not inflate. Is power switch on? Is power cord plugged in correctly? Blockage in garment supply tubing. Check switch. Check connections. Ensure that the tubing airway is clear. Service Returns If for any reason your Flowtron Hydroven 3 is being returned, please: 1. Clean the product following the instructions in section 6. 2. Contact Huntleigh Healthcare (X 157) for a Return Goods Authorization number (RGA) prior to returning your system. Note the RGA number on the outside of packaging. 3. Enclose a covering letter explaining the reasons for the return, with documentation (including an appropriate decontamination certificate if possible). 4. To prevent damage in transport, please pack the pump in a suitably robust box. 12

8. Warranty Warranty: All Huntleigh Healthcare products shall conform to applicable specifications in effect from the invoice date to the end of the Warranty Period, and Huntleigh Healthcare reserves the right to change such specifications at any time with or without notice. The Warranty Period for Huntleigh Healthcare products shall be as follows, calculated from the date of invoice: a. The Flowtron Hydroven 3 pump is guaranteed for 12 months; b. The Flowtron Hydroven 1 and 3 garments are guaranteed for 6 months. Huntleigh Healthcare s sole liability to the Customer for nonconformity of any Products to the specifications therefore, for any claim arising out of or in any way connected with the manufacture, sale, handling, or use of the Products, or for any other reasons, shall be, at Huntleigh Healthcare s sole option, limited to (i) the refund of the full purchase price for such Products, plus the invoice shipping charges, or (ii) replacement thereof, free of charge to the Customer, with Products conforming to the then current specifications, thereof. The parties agree that these remedies shall be exclusive. HUNTLEIGH HEALTHCARE, AND ITS AFFILIATES, SHALL HAVE NO LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND OR, EXCEPT AS PROVIDED ABOVE, FOR ANY CAUSE ARISING OUT OF OR IN ANY WAY CONNECTED WITH THE MANUFACTURE, SALE, HANDLING OR USE OF SUCH PRODUCTS. EXCEPT AS SPECIFICALLY SET FORTH IN THIS PARAGRAPH, THERE ARE NO EXPRESS OR IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND THE FOREGOING PROVISIONS OF THIS PARAGRAPH ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. The customer is solely responsible for the proper use of the Products. Huntleigh Healthcare Products should not be used in conjunction with those of any other manufacturers. 13

Service: The Flowtron Hydroven 3 system should be routinely inspected (at least once every 24 months) by a qualified biomedical service technician to assure proper operation of the pump and garment system. Inspection should verify that pressure output and timing cycles are within listed specifications, and that the audible and visual alarms function properly. The Flowtron Hydroven 3 pump should receive annual preventative maintenance. All required servicing should be performed by Huntleigh Healthcare service personnel: Please obtain a Returned Goods Authorization from the Customer Service Department prior to returning the product to Huntleigh Healthcare. Display the RGA number prominently on the side of the package used to return the product. This will insure prompt and accurate servicing of your product. Return to: Service Department Huntleigh Healthcare L.L.C. 40 Christopher Way Eatontown, NJ 07724-3327 Telephone: (800)-223-1218 14

9. Ordering Information To order garments, please contact your distributor quoting the appropriate codes as shown below: Refer to diagrams on page 5 of this manual. Garments HYDROVEN 1 LEG GARMENTS Order Code Type Length (L) Circumference (W) 5101L50 Half Leg 19.7" (50cm) 24" (61cm) 5101L66 Full Leg 26" (66cm) 25.2" (64cm) 5101L71 Full Leg 28" (71cm) 26" (66cm) 5101L76 Full Leg 29.9" (76cm) 28 (72cm) 5101L84 Full Leg 33.1" (84cm) 28" (72cm) 5101L92 Full Leg 36.2" (92cm) 28" (72cm) HYDROVEN 1 ARM GARMENTS Order Code Type Length (L) Circumference Hand (H) Circumference Shoulder (S) 5101A51 Half Arm 20.1" (51cm) 17.3" (44cm) 22" (56cm) 5101A68 Full Arm 26.8" (68cm) 17.3" (44cm) 24.4" (62cm) 5101A78 Full Arm 30.7" (78cm) 17.3" (44cm) 24.4" (62cm) HYDROVEN 3 LEG GARMENTS Order Code Type Length (L) Circumference (W) 5103L50 Half Leg 19.7" (50cm) 24" (61cm) 5103L66 Full Leg 26" (66cm) 25.2" (64cm) 5103L71 Full Leg 28" (71cm) 26" (66cm) 5103L76 Full Leg 29.9" (76cm) 28" (72cm) 5103L84 Full Leg 33.1" (84cm) 28" (72cm) 5103L92 Full Leg 36.2" (92cm) 28" (72cm) HYDROVEN 3 ARM GARMENTS Order Code Type Length (L) Circumference Hand (H) Circumference Shoulder (S) 5103A68 Full Arm 26.8" (68cm) 17.3" (44cm) 24.4" (62cm) 5103A78 Full Arm 30.7" (78cm) 17.3" (44cm) 24.4" (62cm) 15

Inserts HYDROVEN INSERT PIECES (To Fit Hydroven 1 and Hydroven 3 Garments) Order Code Type Length (L) Added Circumference Wide End Added Circumference Narrow End 510LI50 Half Leg 19.7" (50cm) 7.5" (19cm) 5.5" (14cm) 510LI66 Full Leg 26" (66cm) 7.5" (19cm) 5.5" (14cm) 510LI71 Full Leg 28" (71cm) 7.5" (19cm) 5.5" (14cm) 510LI76 Full Leg 29.9" (76cm) 7.5" (19cm) 5.5" (14cm) 510LI84 Full Leg 33.1" (84cm) 7.5" (19cm) 5.5" (14cm) 510LI92 Full Leg 36.2" (92cm) 7.5" (19cm) 5.5" (14cm) 510AI68 Full Arm 26.8" (68cm) 6.7" (17cm) 4.7" (12cm) 510AI78 Full Arm 30.7" (78cm) 6.7" (17cm) 4.7" (12cm) 16

10. Technical Description Model No.: 510003 Supply Voltage: Supply Frequency: Electrical Rating: Fuse Rating: 120 V 60 Hz 14VA F500 mah 250V Size: Width: 10.6 (270 mm) Weight: Case Material Depth: Height: Electrical Safety Standards: Degree of protection: Degree of protection against ingress of liquids: Mode of operation: 5.9 (150 mm) 4.1 (105 mm) 5.3lbs (2.4 kg) ABS Plastic UL60601-1 1st Edition. CAN/CSA C22.2 No 601.1-M90 Class II Type BF with functional ground Ordinary (not protected) IPX0 Continuous Equipment Symbols: Alternating Current O (off) I (on) Power disconnects from mains Power connects to the mains supply Type BF Double Insulated Fuse 17

Operating Temperature Range: +50 F to +104 F (+10 C to +40 C) Relative humidity: 30% to 75% Atmospheric pressure 700hPa to 1060 hpa Storage Storage temperature range: -40 F to +158 F (-40 C to +70 C) Relative humidity: 10% to 100% (non-condensing) Atmospheric pressure: 500 hpa to 1060 hpa Environmental Protection: Please dispose of this unit in accordance with local regulations 18

19

20

Huntleigh Healthcare Ltd 2006 510900US_01