General-purpose Relays and Power Relays Sockets

Similar documents
(Track-mounting) *see page 243. *see page 246 Screw terminal Solder terminal PCB terminal Screw terminal P2RF-05-E Approx. 38 g. P2R-05P Approx.

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

onlinecomponents.com

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

The Omron STI Hazardous Location

ACCESSORIES. Standard packing

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

E3G-L1/L3. Effectively Cuts the Influence of Workpiece Characteristics, Such as Gloss, Incline, and Color. Distance-setting Photoelectric Sensor

Quick Reference Guide Power Series Switches

SPS-5. Rate Computing Scale. Operation Manual

Screw Terminal Block Cables

Norrsken Family Booklet

Revolution Gurney Attachment

NO: REL-149 PRODUCT: G8P Series PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice

Zelio Relays RSL Slim Interface Plug-In Relays

TURQUOISE SWITCHES ABJ (BJ) SWITCHES

USER MANUAL. DM65 Manual Flush/Tilt Combo Mount

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)

RoHS. WS Series Snap Action Switch. Specifications. Part Number Configurator

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

RTD Temperature sensor TH11

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Installation Instructions for the Walking Beam Interlock for Eaton EHD, FDB, FD, HFD, FDC, FW, HFW, FWC, Circuit Breakers and Molded Case Switches

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-400. Club Volleyball Gear

PRODUCT CATALOGUE WHATEVER YOU RIDE WHATEVER YOU DRIVE...

Inflatable Stand Up Paddle Board Manual

WARNING NOTES TABLE OF CONTENTS

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Digital Melting Point Apparatus

Nitrogen Supply System

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

SERIES L4E & L6E LADDER EXTENSIONS

Cocoa Patio Pond with Lit Spillway

Type 715P/717P, Orange Drop, High Voltage, Polypropylene Film/Foil

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

COOPER POWER SERIES. EL Bay-O-Net Current-Limiting Fuse Installation Instructions. Fusing Equipment MN132023EN

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

This document to be used with Hurley traditional Davits

file:///users/samuel/documents/delft/masters/4th%20year%20su... APCO AVIATION USER MANUAL High-Rise Rescue Chute

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021 Operation Manual

Standard Collection Setup Manual

FLANGED TWO-PIECE BALL VALVES

AUTO PUMP STATUS CENTER

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-300. Club Volleyball Gear. For fixed-height Basketball Hoop Systems

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

MODEL SC401 DUAL CYLINDER SCALE

CP10K. 10,000 lb. Cable Puller Instruction Sheet. SAFETY ISSUES

SPECIFICATIONS APCEPH1

Pasture Meter Auto Lift Kit 5003 (Leaflet Pt.No Issue 4, October 2015)

BT PAINTBALL DESIGNS, INC. 570 MANTUA BLVD., SEWELL, NJ

FLANGED TWO-PIECE BALL VALVES

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-100. Club Volleyball Gear WARNING

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

Rip Clip Manual_2.qxp 4/15/08 11:00 AM Page c

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

PPS PORTABLE POWER SUPPLY

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

USER INSTRUCTION MANUAL CONCRETE BOLT ANCHORAGE CONNECTOR

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RADROVER REAR RACK INSTALLATION MANUAL

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

NOTES TABLE OF CONTENTS

Sample Concentrator SBH CONC/1 Instructions for use

Ambient Weather WS-03 Thermo-Hygrometer

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 6K Puller (M6K-M)

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

COOPER POWER SERIES. Manual or Hostick Operable, Padlockable 150 A Tap-Changer Switch Installation Instructions. Tap-Changer Switch MN800015EN

The Churchill. Chest Clip Guard

Read through all the steps first before working on the camera. Make sure you know what to do.

TMP. PepperBall User Manual

DAKOTA 2006 DUMP BOX ILLUSTRATED PARTS MANUAL

Product Specifications Specialty Junction Boxes

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-200. Club Volleyball Gear. For height-adjustable Basketball Hoop Systems

Owner s Manual High Density Sports Storage Partial End Closure Accessory 32-inch Partial End Closure 48-inch Partial End Closure

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Corning Step-R. Repeating Pipettor. Instruction Manual

RAM 4021-DPX Operation Manual

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

SERIES BB TRASH BASKETS

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

Ambient Weather GL152-TT Marine Time and Tide Clock User Manual

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

Instruction Manual No. 742, 8/98

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

E2B PROXIMITY SENSORS

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Transcription:

General-purpose Relays and Power Relays Sockets Relay Type Track Mount Sockets Back Connecting Sockets Solder terminals PCB terminals G2R-1-S P2RF-05 P2RF-05-E P2RF-05-S P2R-05A P2R-05P G2R-2-S P2RF-08 P2RF-08-E P2RF-08-S P2R-08A P2R-08P LY1, LY2 PTF08A-E PT08 PT08-0 LY3 PTF11A PT11 PT11-0 LY4 PTF14A-E PT14 PT14-0 MK2 PFO83A-E PL08 PLR08-0 MK3 PF113A-E PL11 PLE11-0 MY2 PYF08A-E PYF08A-N PYF08-S PY08 PY08-02 MY3 PYF11A PY11 PY11-02 MY4 PYF14A-E PYF14A-N PYF14S PY14 PY14-02 MY2K PYF14A-E PY14 PY14-02 MY4(Z)H PYF14A-E Relay Type Mounting Bracket Track Mount Adaptor Track Mount Socket G7J-(ALL) R99-04-FOR-G5F W bracket G7L-1A-T R99-07G5D E bracket P7LF-D P7LF-06 G7L-1A-TJ P7LF-06 G7L-1A-B G7L-1A-BJ G7L-2A-T P7LF-06 G7L-2A-TJ P7LF-06 G7L-2A-B G7L-2A-BJ Mounting Track Length PFP-100N 1 meter PFP-50N.5 meter 238 General-purpose Relays and Power Relays Sockets

Square Sockets Item 5 pins P2RF-05 Approx. 27 g P2RF (Track-mounting) *see page 246 P2R *see page 248 P7TF (Trackmounting) *see page 249 Screw terminal Solder terminal PCB terminal Screw terminal P2RF-05-E Approx. 38 g P2R-05A Approx. 5 g P2R-05P Approx. 5 g P2R-057P Approx. 5.5 g P7TF-05 Approx. 28 g 8 pins P2RF-08 P2RF-08-E P2R-08A P2R-08P P2R-087P --- Approx. 33 g Approx. 38 g Approx. 5 g Approx. 5 g Approx. 5.5 g Note: @-E Models are of finger-protect construction. Round terminals cannot be used. Use Y-shaped terminals. Square Sockets Item PYF (Trackmounting) *see page 250 Screw terminal 8 pins PYF08A Approx. 32 g Solder terminal PY08 Approx. 8 g PY (back-connecting) *see page 252 Wrapping terminal PYQ08QN Approx. 12 g PCB terminal PY08-02 Approx. 7.2 g PTF (Trackmounting) *see page 253 Screw terminal PTF08A Approx. 39 g Solder terminal PT08 Approx. 11 g PT (back-connecting) *see page 255 Wrapping terminal PT08QN Approx. 10.4 g PCB terminal PT08-0 Approx. 8 g PYF08A-E PY08-Y1 PYQ08QN2 PTF08A-E PYF08A-N PY08-Y3 PYQ08QN-Y1 PYQ08QN2-Y1 Note: @-E and @-N Models are of finger-protect construction. Round terminals cannot be used. Use Y-shaped terminals. General-purpose Relays and Power Relays Sockets 239

Item 11 pins PYF (Trackmounting) *see page 250 Screw terminal PYF11A Approx. 46 g Solder terminal PY11 Approx. 9 g PY (back-connecting) *see page 252 Wrapping terminal PY11QN PY11QN2 PCB terminal PY11-02 PTF (Trackmounting) *see page 253 Screw terminal PTF11A Approx. 50 g Solder terminal PT11 Approx. 13 g PT (back-connecting) *see page 255 Wrapping terminal PT11QN PCB terminal PT11-0 Approx. 12.2 g PY11-Y1 PY11QN-Y1 PY11QN2-Y1 14 pins PYF14A Approx. 49 g PY14 Approx. 10 g PY14QN PY14QN2 Approx. 14 g PY14-02 PTF14A Approx. 60 g PT14 Approx. 17 g PT14QN Approx. 20 g PT14-0 Approx. 16.2 g PYF14A-E PY14-Y1 PY14QN-Y1 PY14QN2-Y1 PY14QN-Y2 PY14QN2-Y2 PTF14A-E PYF14A-N PY14-Y2 PYF14T Approx. 53 g Note: @-E and @-N Models are of finger-protect construction. Round terminals cannot be used. Use Y-shaped terminals. Item P7LF (Track-mounting) *see page 256 Screw terminal Item Screw terminal (Track-mounting) P7S *see page 257 Solder terminal PCB terminal 6 pins P7LF-06 Approx. 60 g 14 pins P7S-14F Approx. 75 g P7S-14A Approx. 10 g P7S-14P Approx. 10 g 240 General-purpose Relays and Power Relays Sockets

Round Sockets Item 8 pins PF (Trackmounting) *see page 258 PF083A Approx. 34 g P2CF (Trackmounting) P2CF-08 Approx. 55 g PFA (Trackmounting) 8PFA Approx. 57 g P3G (Trackmounting) P3G-08 Approx. 40 g PL (back-connecting) *see page 261 Solder terminal PL08 Approx. 14 g Wrapping terminal PL08-Q Approx. 15 g PCB terminal PLE08-0 Approx. 10.6 g PF083A-E 8PFA1 Approx. 66 g PF085A Approx. 40 g 11 pins PF113A Approx. 47 g P2CF-11 Approx. 70 g 11PFA Approx. 74 g P3GA-11 (see note) Approx. 47 g PL11 Approx. 15 g PL11-Q Approx. 18.5 g PLE11-0 Approx. 10.8 g PF113A-E 14 pins --- --- 14PFA --- PL15 --- --- Approx. 104 g Approx. 28 g 20 pins PF202 --- --- --- PL20 --- --- Approx. 170 g Approx. 17 g Note: This model succeeds the P3G-11 for which production was stopped in March 1991. General-purpose Relays and Power Relays Sockets 241

Hold-down Clips For Square Sockets PYC-A1 (see note) 5 PYC-A2 (see note) 5 PYC-P 5 PYC-E1 (see note) 4.5 1.2 36.3 4.5 4.5 42.8 4.5 1.2 29 3.3 36.5 4.5 +0.1 5.75 36.3 4.25 PYC-P2 10 PYC-S 8 PYC-1 9.4 PYC-2 8 PYC-3 5 PYC-5 10 28 28 2.5 28 28.8 Approx. 3 29.5 3.7 52 58.2 44.5 41.7 PYC 10 3.7 34.5 For Round Sockets PFC-A1 (see note) 4.6 PEC-A6 (see note) 4.6 PEC-A7 (see note) 4.6 PLC (see note) 7.6 PLC-1 (see note) PLC-7 (see note) PLC-8 (see note) 60.8 62 73.3 74.5 94 95.2 56.6 56.3 69.2 65.7 90.2 86.7 6 4.5 6 4.5 6 4.5 8 8 9 8 9 PLC-10 (see note) 5 PLC-12 (see note) 66.2 64.3 6 8 Note: There are 2 pieces per set. 242 General-purpose Relays and Power Relays Sockets

Models Used with Sockets Group Model Pin No. Socket Front-connecting MY(K) MY2 8 PYF PY MY3 11 MY4, MY2K 14 LY LY1, LY2 8 PTF PT LY3 11 LY4 14 G2A(K) G2A, G2A-434, G2AK 14 PYF PY MK(K) MK2P 8 PF083A(-E) PL MK3P, MK2KP 11 PF113A(-E) MM(K) MM2(X)P 8 8PFA MM3P, MM2(X)KP 11 PFA MM3XP, MM3(X)KP, MM4(X)P, 14 MM4(X)KP G4Q --- 8 8PFA1 G7L G7L-@A-T(J) 6 P7LF --- Back-connecting Models Used with Hold-down Clips Square Sockets Item PYF@A(-E, -N), PTF@A(-E) PY@(QN), PT@(QN) PY@-02, PT@-0 MY( ), MY( )N, MY( )N-D2, PYC-A1 PYC-P, PYC-S PYC-P MY( )N-CR, MY2K, LY( ), LY( )N, G3H, G3F, G3FD, G3FM MY4IN PYC-P, PYC-P2 PYC-P, PYC-P2 MY2IN PYC-E1 PYC-P2 PYC-P2 LY( )-CR Y92H-3 PYC-1 PYC-1 G2A(K) Series PYC-A2 PYC-2, PYC-3, PYC-5 PYC-3, PYC-5 Note: Pin numbers 08, 11, or 14 apply to @. Round Sockets Item PF083A, PF113A PL08(-Q), PL11(-Q) PLE08-0, PLE11-0 MK2P Series, MK2KP, MK3P@ PFC-A1 PLC PLC-10 (-US), G3B MK3ZP, MK3LP PLC-1 MYA-NA1, -NB1, PFC-A6 PLC-7 --- MYA-LA1, -LB1, MYA-NA2, -NB2 MYA-LA2, -LB2 MYA-LA12, -LB12 PFC-A7 PLC-8 --- Note: 1. 8PFA(I), 11PFA, and 14PFA has hooks that can hold a Relay. 2. PL15, PL20, PF202, and Sockets that are not listed in the above table should be mounted to a panel after opening mounting on the panel. 3. A Hold-down Clip for PF085A is sold together with Relays that can be used with PF085A. General-purpose Relays and Power Relays Sockets 243

Socket Performance Characteristics Item Carry current Dielectric strength Insulation resistance (see note 2) P2RF-05(-E) 10 A Between contacts of same polarity: 1,000 MΩ min. 1,000 VAC for 1 min Between coil and contact: 4,000 VAC for 1 min P2RF-08(-E) 5 A Between contact of different polarity: 3,000 1,000 MΩ min. VAC for 1 min Between contacts of same polarity: 1,000 VAC for 1 min Between coil and contact: 4,000 VAC for 1 min P2R-057P 10 A Between contacts of same polarity: 1,000 MΩ min. 1,000 VAC for 1 min Between coil and contact: 5,000 VAC for 1 min P2R-087P 5 A Between contact of different polarity: 3,000 1,000 MΩ min. VAC for 1 min Between contacts of same polarity: 1,000 VAC for 1 min Between coil and contact: 5,000 VAC for 1 min P2R-05A 10 A Between contacts of same polarity: 1,000 MΩ min. 1,000 VAC for 1 min Between ground terminal and other terminals: 1,500 VAC for 1 min Between coil and contact: 4,000 VAC for 1 min P2R-08A 5 A Between contact of different polarity: 3,000 1,000 MΩ min. VAC for 1 min Between contacts of same polarity: 1,000 VAC for 1 min Between ground terminal and other terminals: 1,500 VAC for 1 min Between coil and contact: 4,000 VAC for 1 min P7TF-05 5 A Between terminals: 2,000 VAC for 1 min 100 MΩ min. PYF08A-E 7 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. PYF08A-N 7 A (see note 3) Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. PYF11A 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. PYF14A-E 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. PYF14A-N 5 A (see note 3) Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. PY08(-Y1) 7 A Between terminals: 1,500 VAC for 1 min 100 MΩ min. PY08QN(-Y1) 7 A Between terminals: 1,500 VAC for 1 min 100 MΩ min. PY08-02 7 A Between terminals: 1,500 VAC for 1 min 100 MΩ min. PY11(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 MΩ min. PY11QN(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 MΩ min. PY11-02 5 A Between terminals: 1,500 VAC for 1 min 100 MΩ min. PY14(-Y1) 3 A Between terminals: 1,500 VAC for 1 min 100 MΩ min. PY14QN(-Y1) 3 A Between terminals: 1,500 VAC for 1 min 100 MΩ min. PY14-02 3 A Between terminals: 1,500 VAC for 1 min 100 MΩ min. PTF@@A 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min. PT@@ 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min. PT@@QN 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min. PT@@-0 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min. 244 General-purpose Relays and Power Relays Sockets

Item Carry current Dielectric strength Insulation resistance (see note 2) P7LF-06 30 A Between contact of different polarity: 2,000 1,000 MΩ min. VAC for 1 min Between contacts of same polarity: 2,000 VAC for 1 min Between coil and contact: 4,000 VAC for 1 min PF@@@A 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. P2CF 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. P3G(A) 6 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. 8PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. 11PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. PL@@(-Q) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. PLE@@-0 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. P6D-04P 5 A Between contacts of same polarity: 100 MΩ min. 1,000 VAC for 1 min Between coil and contact: 3,000 VAC for 1 min P7S-14@ 6 A Between terminals: 2,500 VAC for 1 min Between ground terminal and other terminals (P7S-14A): 2,000 VAC for 1 min 100 MΩ min. Note: 1. The values given above are initial values. 2. The values for insulation resistance were measured at 500 V at the same place as the dielectric strength. 3. The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55 C. When using the PYF08A-N or PYF14A-N at an operating ambient temperature exceeding 40 C, reduce the current to 60%. Track and Accessories Mounting Track PFP-100N PFP-50N 4.5 7.3±0.15 35±0.3 27±0.15 15 25 25 10 1000 (500) * 25 10 25 15 (5) 1 Mounting Track PFP-100N2 Note: The figure in the parentheses is for PFP-50N. 16 4.5 35±0.3 27 24 29.2 15 25 25 10 1000 25 10 25 15 1 1.5 End Plate PFP-M M4 x 8 pan head screw 10 6.2 1.8 50 11.5 1 35.5 1.8 35.3 Spacer PFP-S 5 10 M4 spring washer 16 12 1.3 4.8 44.3 34.8 16.5 General-purpose Relays and Power Relays Sockets 245

Note: All units are in millimeters unless otherwise indicated. P2RF P2RF-05 (One pole) Five, M3.5 x 8 4 dia. Terminal arrangement/internal connections (top view) Mounting (top view) 4.2-dia. 9 71.5 M3 (M3 x 16) or 3.5-dia. hole 19.5 30 54 Note: Track-mounting is also possible. P2RF-05-E (One pole) M3.5 screw 59 (80.9 )* 48 3.2-dia. 3.5-dia. 85.5 M3 or 3.5-dia. 61 * When mounted on H3RN-1@. Note: Figures in parentheses are DIN standard numbers. Note: Track-mounting is also possible. P2RF-08 (Two poles) Eight, M3.5 x 8 4 dia. 4.2-dia. 9 71.5 M3 (M3 x 16) or 3.5-dia. hole 19.5 30 54 Note: Track-mounting is also possible. 246 General-purpose Relays and Power Relays Sockets

(top view) Mounting (top view) P2RF-08-E (Two poles) M3 screw 63 (84.9 )* 48 3.2-dia. 3.5-dia. 3 dia. 85.5 M3 or 3.5-dia. 61 * When mounted on H3RN-2@. Note: Figures in parentheses are DIN standard numbers. Note: Track-mounting is also possible. Note: When indicator modules with an I/O SSR are used, the No. 1 pin becomes positive. General-purpose Relays and Power Relays Sockets 247

P2R P2R-05P (One pole) 14.5 Terminal arrangement/ (bottom view) Mounting (bottom view) Five, 1.6-dia. 35.5 P2R-08P (Two poles) 14.5 36.5 Eight, 1.3-dia. 35.5 36.5 P2R-057P (One pole) 14 Five, 1.6-dia. 37 P2R-087P (Two poles) 14 41 Eight, 1.3-dia. 37 41 Note: When indicator modules with an I/O SSR are used, the No. 1 pin becomes positive. 248 General-purpose Relays and Power Relays Sockets

P2R/P7TF P2R-05A (One pole) 14.5 Mounting 35.5 Five, 3 x 1.8-dia. (Bottom view) 36.5 P2R-08A (Two poles) 14.5 Use panel with thickness of 1.6 to 2.0 mm. 35.5 Eight, 3 x 1.2-dia. (Bottom view) P7TF-05 19 36.5 Screw with square washer 71.5 ( )(+) 59 (Top view) (Top view) Two, 3.0 dia. Note: Track-mounting is also possible. Note: When indicator modules with an I/O SSR are used, the No. 1 pin becomes positive. General-purpose Relays and Power Relays Sockets 249

PYF Terminal arrangement/ (top view) Mounting (top view) PYF08A Two, 4.2 x 5 mounting 6 Eight, M3 x 8 sems screws 3.4 Two, M3, M4, or 4.5-dia. 72 35.4 59±0.3 23 6 16.5 30 4 15±0.2 Note: Track-mounting is also possible. PYF08A-E Two, 4.2 x 5 mounting 6 Eight, M3 x 8 sems 3.4 Two, M3 or M4 (or 4.5-dia.) 72 35.4 59±0.3 4 15±0.1 23 6 16.5 31 Note: Track-mounting is also possible. PYF08A-N 4 42 8 22 44 1 12 5 14 42 12 4 1 44 14 8 5 18.7 3.0 dia. 3.5 dia. or M3 67 PYF-08A-N 41 11 12 9 A2 A2 A1 14 14 13 73 30 12 9 41 11 14 14 13 A2 A2 A1 Note: Track-mounting is also possible. Refer to page 245 for Mounting Tracks. PYF11A Two, 4.2 x 5 mounting Eleven, M3 x 8 sems Two, M3 or M4 (or 4.5-dia.) 72 29.5 30 Note: Track-mounting is also possible. 250 General-purpose Relays and Power Relays Sockets

Terminal arrangement/ (top view) Mounting (top view) PYF14A Two, 4.2 x 5 mounting Fourteen, M3 x 8 sems 72 Two, M3 or M4 (or 4.5-dia.) 29.5 30 8 3 2 1 8 7 6 5 PYF14A-E Two, 4.2 x 5 mounting Fourteen, M3 x 8 sems 12 11 10 9 4 14 13 72 Note: Track-mounting is also possible. 29.5 31 PYF14A-N 4 42 8 44 3 32 7 34 2 22 6 24 1 12 5 14 42 32 22 12 4 3 2 1 44 34 24 14 8 7 6 5 Two, 4.5 dia. or M4 67 PYF-14A-N 41 31 21 11 12 11 10 9 73 26 A2 A2 A1 14 14 29.5 13 30 12 11 10 9 41 31 21 11 14 14 13 A2 A2 A1 Note: Track-mounting is also possible. Refer to page 245 for Mounting Tracks. PYF14T Two, 4.2 x 5 dia. mounting 33 3 2 1 8 7 6 5 Two, M4 70 12 11 10 9 4 14 13 Note: Track-mounting is also possible. Fourteen, M3 x 8 sems General-purpose Relays and Power Relays Sockets 251

PY PY08 PY08-Y1 PY08-Y3 5 * 2.7 7.7 42 20 Eight, 3-dia. x 1.2 ellipses 2.6 24 25.5 29.5 Note: PY08-Y1 includes the part outlined by the dashed lines above. PY08QN PY08QN2 PY08QN-Y1 PY08QN2-Y1 5 * 2.7 42 (20) 25 41.5 (36.5 ) 22 24 29.5 Note: 1. PY08QN(2)-Y1 includes the part outlined by the dashed lines above. 2 The figures in the parentheses are for PY08QN2. PY08-02 1 1.0 (bottom view) +0.2 25.8 0 5.8 6.4 Mounting 4.2 +0.2 21.4 0 13.2 4.1 6.35 12.65 Eight, 1.3-dia. 0.3 25.5 29.5 2.7 4.3 16.5 22 Note: PY08-Y1 includes the part outlined by the dashed lines above. PY11 PY11-Y1 * Eleven, 3-dia. x 1.2 ellipses 2 25.5 29.5 42 20 24 Note: PY11-Y1 includes the part outlined by the dashed lines above. PY11QN PY11QN2 PY11QN-Y1 PY11QN2-Y1 * 29.5 42 41.5 (36.5 )** 22 24 Note: 1. PY11QN(2)-Y1 includes the part outlined by the dashed lines above. PY11-02 2 The figures in the parentheses are for PY11QN2 (-Y1). ** Eleven, 1.3-dia. 25.5 29.5 16.5 22 252 General-purpose Relays and Power Relays Sockets

PY14 PY14-Y1 (l=42 ) PY14-Y3 (l=60 ) * Fourteen, 3-dia. x 1.2 ellipses (bottom view) Mounting 25.5 29.5 20 24 Note: PY14-Y1 includes the part outlined by the dashed lines above. PY14QN, PY14QN2 PY14QN-Y1 (l=42 ) PY14QN2-Y1 (l=42 ) PY14QN-Y2 (l=49 ) PY14QN2-Y2 (l=49 ) PY14QN-Y3 (l=60 ) PY14QN2-Y3 (l=60 ) l * 29.5 41.5 (36.5 )** 22 24 Note: 1. PY11QN(2)-Y1 includes the part outlined by the dashed lines above. 2 The figures in the parentheses are for PY11QN2 (-Y1). PY14-02 ** Fourteen, 1.3-dia. 25.5 29.5 16.5 22 Note: 1. Use a panel with a thickness of 1 to 2 mm when mounting a Socket on it. 2. The PY14-Y1 and the PY14QN-Y1 can be used with MY4-series models and the MY2K. PTF PTF08A Two, 4.5 x 6 7 mounting Eight, 3.5M x 8 screw (top view) Mounting (top view) 3.4 Two, M4 or 4.5-dia. 78.5 35.4 68 ±0.3 28.5 8 30 27.5±0.2 Note: Track-mounting is available. See page 245. General-purpose Relays and Power Relays Sockets 253

(top view) Mounting (top view) PTF08A-E Two, 4.5 x 6 mounting 7 Eight, M3.5 x 8 sems 3.4 Two, M4 or two, 4.5-dia. 68±0.3 78.5 35.4 19±0.2 28.5 8 32.65 Note: Track-mounting is available. See page 245. PTF11A Two, 4.5 x 6 mounting Eleven, 3.5M x 8 screw Two, M4 or 4.5-dia. 78.5 37 30 Note: Track-mounting is available. See page 245. PTF14A Two, 4.5 x 6 mounting Fourteen, 3.5M x 8 screw 78.5 Two, M4 or 4.5-dia. 45.5 30 PTF14A-E Two, 4.5 x 6 mounting Fourteen, 3.5M x 8 screw 78.5 Note: Track-mounting is available. See page 245. 45.5 33 Note: If PTF08A and PT08 are used in combination with LY1 with a total current flow of 10 A minimum, terminals 1 and 2, 3 and 4, 5 and 6 respectively should be short-circuited. 254 General-purpose Relays and Power Relays Sockets

PT Terminal arrangement/ (bottom view) Mounting PT08 5 PT08QN 1.5 x 10 0.3 25.5 1.0 29.5 25.8 +0.2 0 2.7 20.5 PT08-0 PT11 Eight, 1.7-dia. x 3.5 ellipses 25.5 29.5 2 0.3 1 4.3 18 2 5* 2.7 9 2.5 35 22 20 1.5 6.5 24 29.5 *Keep a proper distance between the Socket and PCB patterns. PT11QN 1.5 x 10 2 5.35 6.5 15.6 10 21.4 +0.2 0 4.6 12.45 6.45 3 Eight, 2.5-dia. The tolerance is ±0.1. Eleven, 1.7-dia. x 3.5 32 35 29.5 32 20.5 PT11-0 29.5 Eleven, 2.5-dia. 5* 32 18 29.5 *Keep a proper distance between the Socket and PCB patterns. The tolerance is ±0.1. General-purpose Relays and Power Relays Sockets 255

Terminal arrangement/ (bottom view) Mounting PT14 PT14QN 1.5 x 1.0 20.5 Fourteen, 1.7-dia. x 3.5 26.5 29.5 42.5 35 26.5 29.5 42.5 PT14-0 5* 42.5 17.5 26.5 29.5 *Keep a proper distance between the Socket and PCB patterns. The tolerance is ±0.1. Fourteen, 2.5-dia. Note: Use a panel with a thickness of 1 to 2 mm when mounting a Socket on it. P7LF (top view) Mounting P7LF-06 Two, M3.5 (coil side) 51.5 Four, M4 (contact side) 0 1 Two, M4 or 4.5-dia. 55.5 46 2 4 6 8 256 General-purpose Relays and Power Relays Sockets

P7S Mounting P7S-14F 40 Fourteen, M3.0 Two, M3.5 or 4.0-dia. 47 P7S-14A 90.5 40 23 61.5 G7S-4A2B (top view) 33 G7S-3A3B P7S-14P 61.5 (bottom view) G7S-4A2B 23 29 Two, 6.5 dia. 7.9 G7S-3A3B Two, 3.6 dia. Fourteen, 1.8 dia. 23 (bottom view) General-purpose Relays and Power Relays Sockets 257

PF (top view) Mounting PF083A Eight, M3.5 x 7 sems screws 7 4 Two, M4 or 4.5-dia. Two 4.2-dia. 52 35.4 33±0.2 4 33 41 3.5 2 21 Note: Track-mounting is available. See page 245. PF083A-E Eight, M3.5 x 7 sems 7 4 52 Two, 4.2-dia. 35.4 Two, M4 or two, 4.5-dia. 33±0.2 4 23 33 41 3.5 2 21 PF085A Eight, M3.5 x 7 sems screws 7 4 Two, M4 or 4.5-dia. 58 Two 4.5-dia. 35.4 33±0.2 Note: Track-mounting is available. See page 245. 4 33±0.2 40 1.1 2 3.5 21.6 PF113A Eight, M3.5 x 7 sems screws 52 Two 4.2-dia. Two, M4 or 4.5-dia. 41 21 PF113A-E Eight, M3.5 x 7 sems 52 Two, 4.2-dia. Note: Track-mounting is available. See page 245. 41 21 258 General-purpose Relays and Power Relays Sockets

PF202 (top view) Mounting 101 Two, M4 or 4.5-dia. Two, 4.5-dia. 71 Two, M3 Relay mounting screws 33 Note: The key groove of PF083A and PF113A (used with MK Relays) are on the upside. P2CF/PFA (top view) Mounting P2CF-08 Eight, M3.5 x 7.5 sems screws Two, M4 or 4.5-dia. 70 Two, 4.5-dia. Note: Track-mounting is available. See page 245. P2CF-11 Eleven, M3.5 x 7.5 sems screws 50 31.2 Two, 4.5-dia. mounting 70 Two, 4.5-dia. Note: Track-mounting is available. See page 245. 50 31.2 General-purpose Relays and Power Relays Sockets 259

(top view) Mounting 8PFA Eight, M3.5 x 7 sems screws Two, 4.5-dia. 81 118 51 24 Two, 4.5-dia. mounting 8PFA1 Eight, M3.5 x 7 sems screws Note: Track-mounting is available. See page 245. Two, 4.5-dia. 93 130 51 24 PFA/P3G/P3GA 11PFA Eleven, M3.5 x 7 sems screws (top view) Mounting Two, 4.5-dia. Two, M4 or 4.5-dia. 81 118 Note: Track-mounting is available. See page 245. 14PFA Fourteen, M3.5 x 7 sems screws 51 33.5 Two, 4.5-dia. Two, M4 or 4.5-dia. 81 118 Note: Track-mounting is available. See page 245. 72 33.5 260 General-purpose Relays and Power Relays Sockets

P3G-08 27 dia. (top view) --- Mounting P3GA-11 27 dia. --- PL Terminal arrangement/ (bottom view) Mounting PL08 3.5 4 1 Two, 3.5-dia. or two, M3 Relay-mounting 51 40 30 dia. 0.6t x 1.3 16 Two, 3.5-dia. or two, M3 Socket-mounting 31-dia. hole 40±0.3 74 or 86 35 35 PL08-Q 50.5 40 3.5 30 dia. 4 1 Two, 2-dia. 3.9 Two, 3.5-dia. or two, M3 Socket-mounting Two, 3.5-dia. or two, M3 Relay-mounting 31-dia. hole 40 ±0.3 72 35 Approx. 20.5 PLE08-0 14 5 0.3t 19 Two, 3.5-dia. Hold-down Clip-mounting 29 dia.±0.3 27.7±0.5 40±0.3 21.5 Eight, 2.5-dia. Note: When mounting, pay due attention to the direction of the key groove of applicable Relays. General-purpose Relays and Power Relays Sockets 261

PL (bottom view) Mounting PL11 Two, 2-dia. 51 30 dia. Two, 3.5-dia. or two, M3-mounting for applicable models PL11-Q 35 Approx. 20.5 Two, 3.5-dia. or two, M3 Socket-mounting 31-dia. hole L=40 mm MK3P, MK2KP, MK3ZP, MK3LP L=74 mm MM3P, MM2(X)KP 51 PLE11-0 35 35 Two, 3.5-dia. Hold-down Clip-mounting 29±0.1 dia. 22 MK3P MK2KP Eleven, 2.5-dia. Eleven, 2.5-dia. L= Distance between mounting required for MK PL15 66 41 Two, 2-dia. Two, 3.5-dia. or two, M3 Socket-mounting Two, 3.5-dia. or two, M3-mounting for applicable models 42-dia. hole MK3XP, MM4(X)P, MM3(X)KP, MM4(X)KP 45 22 PL20 46.5 Two, 3.5-dia. 31 Two, 2-dia. Two, Socket-mounting Two, 4.5-dia. Relay-mounting 33-dia. hole Note: Mounting hole preparation not required for LDNP. 36.5 23 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. 262 General-purpose Relays and Power Relays Sockets

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 14

OMRON ELECTRONICS LLC THE AMERICAS HEADQUARTERS Schaumburg, IL USA 847.843.7900 800.556.6766 www.omron247.com OMRON CANADA, INC. HEAD OFFICE Toronto, ON, Canada 416.286.6465 866.986.6766 www.omron247.com OMRON ELETRÔNICA DO BRASIL LTDA HEAD OFFICE São Paulo, SP, Brasil 55.11.2101.6300 www.omron.com.br OMRON ELECTRONICS MEXICO SA DE CV HEAD OFFICE Apodaca, N.L. 52.811.156.99.10 001.800.556.6766 mela@omron.com OMRON ARGENTINA SALES OFFICE Cono Sur 54.11.4783.5300 OMRON CHILE SALES OFFICE Santiago 56.9.9917.3920 OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 Omron Europe B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu J35I-E-01 01/07 Note: Specifications are subject to change. 2010 Omron Electronics LLC