Radiator valves VDN2.. VEN2.. VUN2..

Similar documents
Radiator valves VDN1.. VEN1..

3-port seat valves with externally threaded connection, PN 16

2-port seat valves PN25 with externally threaded connections

2-port and 3-port valves PN 16

2-port and 3-port seat valves, PN16

Two-port valves, male threaded, PN25

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

2-Port Seat Valves with Flange, PN 16

2-Port and 3-Port Seat Valves with Female Thread, PN16

2-Port Seat Valves with Flange, PN 16

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

RA-N radiator valves with integrated presetting and self-sealing tailpiece

AVP-F. p setting range (bar) Code No. 003H6200

HERZ-Motorised flow controler

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Pressure Independent Control Series

Seated valves VRB 3, VRG 3

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Products no longer available

Rotary valves HRB 3, HRB 4

Type overview. R B2 en-gb subject to changes 1

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

Ballorex Dynamic Description. Versions. Benefits. Balancing

Overview of types. Technical data. Safety notes

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX

Products no longer available

Presetting Valve Type RA-N with Flange Connection

AVPQ/AVPQ-F, PN 16. Application

Two-port seat valves

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange

VZL valve - 2/3/4-way

Rotary valves HRB 3, HRB 4

Overview of types. Technical data

Modulating refrigerant valves with magnetic actuator, PS45 Hermetically sealed, for safety refrigerants

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

Pressure balanced valves (PN 25)

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

Solenoid valves VZWF, force pilot operated

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

HERZ - Compact Flow Controller with

STAP. Differential pressure controller DN 15-50

3-way control valves VK 3

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

STAP. Differential pressure controller DN

Pressure reduction controller (PN 16, 25, 40)

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

Pressure independent control valve (PICV) FLOWMATIC

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

Pressure Reducing Valve DMV 755

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Seated valve for steam (PN 25)

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

TRV-2, TRV-2S. Thermostatic radiator valves With presetting

Automatic balancing valves ASV

Upgradable balancing valves USV

Valves for Biogases and Recycling Gases

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Double valves for biogases and recycling gases

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

C 10 Pressure Reducing Valve

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Automatic balancing valves ASV

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

STA. Double regulating valves DN 15-50

differential pressure regulating valve - threaded

kyone for All - Unique Mixproof

B2KL: 6-way ball valve with male thread, PN 16

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

STAP. Differential pressure controllers DN , ANSI flanges

HERZ - Compact Flow Controller with

STA. Double regulating valves DN 15-50

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

Propor tional Re lief Valve s

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

TA-H.U.B. Centralised balancing and control ENGINEERING ADVANTAGE

CLASS TLP Pressure Reducing Valve

6-way characterised control valves DN15 / DN 20 / DN 25

Transcription:

2 106 EN 215 Straight valves VDN2.. Angle valves VEN2.. Reverse angle valves VUN2.. ACVATIX TM Radiator valves VDN2.. VEN2.. VUN2.. NF norm, for 2-pipe heating systems Valve bodies made of brass, mat nickel-plated DN 10, DN 15 and DN 20 (VDN2.., VEN2..) Integrated preadjustment of k v -values Internally and externally threaded (Rp/R) conforming to ISO 7-1 Manual knob / protective cover included in the delivery Can be combined with RTN.. thermostatic actuators, SSA.. electromotoric actuators, STA..3.. electrothermal actuators or SSA955 RF-controlled actuators CE1N2106en 2017-07-20 Building Technologies

Use The radiator valves are used in hot water heating plant for individual room or zone temperature control and limitation. They are basically recommended in all rooms, especially where heat gains or different temperature levels occur. Type summary Product number straight VDN210 VDN215 Product number angle VEN210 VEN215 Product number reverse angle VUN210 VUN215 VDN220 VEN220 20 DN X P k v-value [m 3 /h] 1 - N 10 15 X P = 2 X P =1.5 X P = 1 X P = 2 0.072 0.43 0.057 0.33 0.037 0.22 0.14 0.43 X P =1.5 0.12...0.37 X P = 1 0.08...0.24 X P = 2 X P =1.5 X P = 1 X P = 2 0.073 0.50 0.058 0.40 0.038 0.27 0.13 0.5 X P =1.5 0.11...0.43 X P = 1 0.07...0.28 X P = 2 X P =1.5 X P = 1 0.22 0.70 0.17 0.55 0.11 0.36 k vs-value [m 3 /h] without actuator N 0.63 0.60 0.89 0.77 1.41 Ordering Example: Product number Order number Designation Quantity VDN220 VDN220 Straight Valves 2 ATN2 ATN2 Protection against dismantling 1 Delivery Valves and accessories are packed separately. Equipment combinations Product Product number Data sheet Thermostatic actuators RTN.. N2111 Electromotoric actuators SSA31.. / SSA61.. / SSA81.. N4893 RF-controlled electromotoric actuators SSA955 N2700 Electrothermal actuators STA..3.. N4884 2/16

Mechanical design / technical design The flow rate can be preadjusted with an orifice. Full stroke is ensured irrespective of the preadjustment, which is made with the help of the protective cover. 1 Manual knob / protective cover 2 Sealing gland 3 Valve insert 4 O-ring 5 Reset spring 6 Orifice Features and benefits The valves conform to EN 215. The sealing gland can be replaced while the plant is under pressure (no tools required). Accessories ATN2 Protection against dismantling ATN4 Manual knob AVN.. Compression fittings 3/16

Engineering notes The reference numbers for preadjustment are given in the table with the k v -values (see page 5) and in the "Valve sizing charts" (see pages 7 7). 1. Calculate the volumetric water flow V % 100. Q 1.163 ΧT f 100 V 100 < [m 3 /h] 1 Q 100 = heat demand [kw] ΔT = temperature differential [K] 1.163 = constant of water f 1 = correction factor = 1 for water 2. Define the pressure drop Δp v100 across the fully open valve In most types of plant, a differential pressure Δp v100 of 0.05 to 0.2 bar is adequate. 3. Calculation of the nominal flow value k v k v V% 100 < [m 3 /h] Δp v100 = differential pressure across the valve [bar] Δp v100 Example: Heat demand Q 100 = 1.2 kw Temperature differential ΔT = 20 K Water volume Required differential pressure across the valve. V 100 Δp v100 1.2 < 1.163 20 = 0.052 m 3 /h = 52 l/h = 0.1 bar Flow 0.052 k v < = 0.17 m 3 /h 0.1 Solution According to the chart (refer to "Valve sizing charts", or table with k v -values), the preadjustment required for a VDN210 3/8 valve is 2. Tips Noiseless operation is ensured by a pump that provides no more pressure than is needed to transport the required amount of water. To keep the valve free from dirt particles, it is recommended to install a strainer. 4/16

k v -values The k v -value gives the volumetric water flow 100 across the valve of 1 bar. V. in m 3 /h at a pressure drop Δp v100 k v -values [m 3 /h] at the different preset positions Control range with actuators SSA.. and STA..3.. Control range of thermostatic actuators RTN.. Reference numbers for preadjustment VDN210 / VEN210 XP 2K 1 2 3 4 5 N N(k vs ) 0.072 0.17 0.24 0.28 0.37 0.43 VDN210 / VEN210 XP 1.5K VDN210 / VEN210 XP 1K VDN215 / VEN215 XP 2K VDN215 / VEN215 XP 1.5 K VDN215 / VEN215 XP 1K VDN220 / VEN220 XP 2K VDN220 / VEN220 XP 1.5K VDN220 / VEN220 XP 1K VUN210 XP 2K VUN210 XP 1.5K VUN210 XP 1K VUN215 XP 2K VUN215 XP 1.5K VUN215 XP 1 K 0.057 0.135 0.19 0.23 0.29 0.33 0.037 0.089 0.13 0.145 0.19 0.22 0.07 0.17 0.28 0.36 0.45 0.50 0.058 0.14 0.23 0.28 0.35 0.40 0.038 0.09 0.15 0.18 0.24 0.27 0.22 0.35 0.44 0.52 0.60 0.71 0.17 0.27 0.35 0.42 0.46 0.55 0.11 0.18 0.23 0.28 0.31 0.36 0.14 0.26 0.34 0.39 0.40 0.43 0.12 0.22 0.29 0.33 0.34 0.37 0.08 0.14 0.19 0.21 0.22 0.24 0.13 0.22 0.30 0.39 0.45 0.50 0.11 0.19 0.26 0.33 0.38 0.43 0.07 0.12 0.16 0.22 0.25 0.28 0.63 0.89 1.41 0.60 0.77 5/16

Setting the kv-values The k v -values can be set on the valve s head in 5 steps + N (fully open) using the protective cover, which can be turned through 180. Observe marking on the valve s outlet side! 6/16

Valve sizing charts VDN210 VEN210 Xp Band 2 K VDN210 VEN210 Xp Band 1.5 K 7/16

VDN210 VEN210 Xp Band 1 K VDN215 VEN215 Xp Band 2 K 8/16

VDN215 VEN215 Xp Band 1.5 K VDN215 VEN215 Xp Band 1 K 9/16

VDN220 VEN220 Xp Band 2 K VDN220 VEN220 Xp Band 1.5 K 10/16

VDN220 VEN220 Xp Band 1 K VUN210 Xp Band 2 K 11/16

VUN210 Xp Band 1.5 K VUN210 Xp Band 1 K 12/16

VUN215 Xp Band 2 K VUN215 Xp Band 1.5 K 13/16

VUN215 Xp Band 1 K Notes Mounting Orientation Mounting Instructions are printed on the package. Mounting orientation depends on selected actuator. The valves are supplied preadjusted to N (fully open). To ensure correct functioning of the thermostatic heads and electronic actuators, observe the available mounting choices and mounting conditions. 90 SSA.. SSA955 RTN51.. RTN71.., RTN81.., STA..3.. 90 2105Z01 90 90 4362Z01 90 90 90 90 2185Z12 Maintenance Repair The valves are maintenance-free. In the event of leakage, the valve s sealing gland can be replaced. The valves cannot be repaired; the complete unit must be replaced. Disposal Do not dispose of the device as household waste. Special handling of individual components may be mandated by law or make ecological sense. Observe all local and currently applicable laws and regulations. 14/16

Warranty Application-related technical data are only warranted when used in connection with the Siemens controllers and actuators listed under "Equipment combinations", page 2. When using the valves with actuators of other manufacture proper functioning must be ensured by the user. Any warranty by Siemens becomes void. Technical data Functional data PN class PN 10 Suitable media 1) cold and low-temperature hot water, water with propylene-glycol, water with ethylene-glycol < 30%; recommendation: water treatment to VDI 2035 Medium temperature 1 120 C Perm. operating pressure 1000 kpa (10 bar) Differential pressure Χp max max. 60 kpa (0.6 bar) Differential pressure Χp v100 5 20 kpa (0.05 0.2 bar): recommended range Stroke min 1.2 mm Materials Valve body brass, mat nickel-plated Fitting brass, mat nickel-plated Protective cover polypropylene O-ring EPDM, NBR Dimensions / weight Refer to "Dimensions", page 16 Mounting length EN 215 Standards, directives and approvals Thread Pressure Equipment Directive Rp internally threaded R externally threaded G-thread PED 2014/68/EU Pressure Accessories Scope: Article 1, section 1 Definitions: Article 2, section 5 to ISO 7-1 to ISO 7-1 to ISO 228-1 Fluid group 2: DN 40 without CE-marking as per article 4, section 3 (sound engineering practice) 2) RoHS conformity EAC Conformity Environmental compatibility compliant Eurasia Conformity The product environmental declaration CE1E2105en 3) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). 1) Prefer propylene-glycol for environment protection reasons. 2) Valves where PS x DN < 1000, do not require special testing and cannot carry the CE label. 3) The documents can be downloaded from http://siemens.com/bt/download. 15/16

E Dimensions VDN2.. VEN2.. VUN2.. E 2106M01 E R D D Rp C C G R R G B G B l 2 l 1 l 4 Rp Rp l 3 A C 2106M02 2106M03 Dimensions [mm] Thread [inch] Weight Prod. no. DN l 1 l 2 l 3 l 4 A B C D E Rp R G [kg] VDN210 10 50 75 53 18 35 ⅜ ⅜B ⅝ 0.220 VDN215 15 55 82 53 18 35 ½ ½B ¾ 0.265 VDN220 20 65 98 53 18 35 ¾ ¾B 1 0.385 VEN210 10 24 49 20 53 18 35 ⅜ ⅜B ⅝ 0.215 VEN215 15 26 53 23 53 18 35 ½ ½B ¾ 0.260 VEN220 20 30 63 26 53 18 35 ¾ ¾B 1 0.360 VUN210 10 51 22 60 25 35 ⅜ ⅜B ⅝ 0.285 VUN215 15 57 27 61 26 35 ½ ½B ¾ 0.330 Prod. no. DN Compression fittings for copper and soft steel pipes for plastic pipes with aluminum foil VDN210 10 Type Connection valve side Connection pipe side Type Connection valve side Connection pipe side [Inch] pipe Ø [mm] [Inch] pipe Ø [mm] VDN215 15 AVN15-15 ½ 15 AVN15-A16 ½ 16 x 2 VDN220 20 VEN210 10 VEN215 15 AVN15-15 ½ 15 AVN15-A16 ½ 16 x 2 VEN220 20 VUN210 10 VUN215 15 AVN15-15 ½ 15 AVN15-A16 ½ 16 x 2 Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2006 Delivery and technical specifications subject to change 16/16