Fasten-In-Place Bases Model Numbers: See Figure 1

Similar documents
D-Ring Anchorage Connector

This manual is intended to meet the Manufacturer s Instructions and should be used as part of an employee training program.

USER INSTRUCTION MANUAL DOOR JAMB ANCHOR

UNI ANCHOR PLATE with TIE DOWN

LAD-SAF STATIC WIRE ROPE GRAB

1.2 LIMITATIONS: Consider the following application limitations before using this equipment:

Model Numbers:

USER INSTRUCTION MANUAL CONCRETE DETENT ANCHORAGE CONNECTOR

USER INSTRUCTION MANUAL SAFLOK MINING BOLT ANCHOR

User Instruction Manual Cabloc Detachable Cable Sleeve This manual is intended to be used as part of an employee training program.

User Instruction Manual Fixed Beam Anchor

Figure 1 - Parts Identification

Figure 1 - Cable Grip Horizontal Lifeline Termination ZORBIT ENERGY ABSORBER RELEASE TAB

USER INSTRUCTION MANUAL CONCRETE BOLT ANCHORAGE CONNECTOR

USER INSTRUCTION MANUAL ROLLGLISS R520 ESCAPE DEVICE

User Instruction Manual

User Instruction Manual Fixed Beam Anchor

IMPORTANT: If you have questions on the use, care, application, or suitability of this equipment contact DBI/SALA.

User Instruction Manual. Fixed Beam Anchor

INSTRUCTIONS FOR USE

INSTRUCTIONS FOR USE

Figure 1 - Parts Identification. Copyright 2002, DB Industries, Inc.

USER INSTRUCTION MANUAL TIE-OFF ADAPTER AND SCAFFOLD CHOKER ANCHORAGE CONNECTORS

Instructions for the following series products:

Counterweight Rail Fall Arrest System (FAS)

Roof Anchor and Sayfline Horizontal Lifeline System

User Instruction Manual Synthetic Rope Horizontal Lifeline System

User Instruction Manual For Davit Rescue System

Rescue ladder System. User Instruction Manual

DBI SALA Confined Space Rescue Davit System

USER INSTRUCTION MANUAL HINGED ROOF ANCHOR

User Instruction Manual Protecta Reusable Concrete Anchor Model Number:

IMPORTANT: Record the product identification information from the ID label in the inspection and maintenance log in section 9.0 of this manual.

USER INSTRUCTION MANUAL 100% TIE-OFF TALON SELF RETRACTING LIFELINES

USER INSTRUCTION MANUAL SIDE ENTRY SYSTEM

USER INSTRUCTION MANUAL ROOF ANCHORS

USER INSTRUCTION MANUAL WEB AND ROPE LANYARDS, D-RING EXTENSION

CONFINED SPACE RESCUE

User Instruction Manual

INSTRUCTION MANUAL. Top Bracket & Bottom Bracket Anchorage Connectors 1.0 APPLICATIONS: DESCRIPTION

IMPORTANT: If you have questions on the use, care, or suitability of this equipment for your application, contact DBI/SALA.

Figure 1 - Snap Hooks and Carabiners PART NUMBER MANUFACTURER S ID YEAR OF MANUFACTURE PART NUMBER MANUFACTURER S ID YEAR OF MANUFACTURE

RollGliss Rescue Emergency Descent Device. This manual is intended to be used as part of an employee training program as required by OSHA.

Saflok Concrete Wedge Anchor

Important: If you have questions on the use, care, or suitability of this equipment for your application contact Capital Safety.

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

INSTRUCTIONS FOR USE

User Instructions 1789 Parapet Wall Anchor

User Instruction Manual Roof Anchor and / Sayfline Horizontal Lifeline System

Metal/Wood Swiveling Roof Anchor

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

User Instruction Manual Tripod Anchorage Connectors

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

rooftop anchor Standing Seam Metal Roofs

USER INSTRUCTION MANUAL SYNTHETIC ROPE GRAB

Instructions for the following series products:

User Instructions 1790 Rail Anchor

TRUSTED. DURABLE. RELIABLE.

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

Rail Supporting Gusset (not included with all systems) Label Locations

ExoFit NEX Full Body Suspension Harness

OPERATION AND INSTRUCTION MANUAL ROLLER SLING Model: IN106.3FT & IN106.2FT

Rescue Ladder Basic Kit Model: FS-EX243 18ft (5.48m)

Vertical Lifeline. Ladder Climb. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248

OPERATION AND INSTRUCTION MANUAL

User Instruction Manual

User Manual 1792 Standing Seam Metal Roof Retractable Swivel Anchor

MAN RATED CONFINED SPACE ENTRY/RETRIEVAL SYSTEMS UCL ADVANCED PORTABLE 14 FALL-ARREST POST OPERATOR S MANUAL

Rescue Ladder Basic Kit Model: LDR-BAS-CTS 18ft (5.48m)

OPERATION AND INSTRUCTION MANUAL Beam Trolley Model: BTA012N

User Instruction Manual Metal/Wood Swiveling Roof Anchor

USER INSTRUCTION MANUAL ROLLGLISS R550 RESCUE & ESCAPE DEVICE

ANCHORAGE STRAPS INSTRUCTION MANUAL

User Instruction Manual. Tip Over Permanent Roof Anchor

Rescue Ladder Model: CTB LDR-RSC 18ft (5.48m)

SUPER SLIDER BEAM ANCHOR ADJUSTABLE FROM Model # BWA030N

User Instruction Manual

Permanent Roof Anchors

A N C H O R T A B S N O R T H W E S T ANCHOR TAB VF. Patented. User Instructions

IMPORTANT: If you have questions on the use, care, application, or suitability for use of this safety equipment, contact DBI-SALA.

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

WrapBax 2 Lanyards With Integral Energy Absorbers

USER INSTRUCTION MANUAL (SSB63) CLIMB ASSIST/FALL ARREST SYSTEM

No East Kilbride, Glasgow G75 0QU UK. No BSI Product Services Kitemark House Mayland Ave. Hemel Hempstead HP2 4SQ UK 11

Rescue Ladder Model: KT ft (5.48m)

Tripod. System. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # VBC014N

USER INSTRUCTIONS LARGE HOOK & STRAP ANCHORAGE CONNECTOR ! WARNING

Product Name: Edge Series Web SRL

Product Name: 2-Way Standing Seam Roof Clamp

sealed self retracting lifeline

Retractable. Dual Leg. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

Product Name: Bull Ring Anchor

Product Name: Concrete Anchor Strap

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

Product Name: Hold Me Rope Anchor

BANTAM BEAMER ADJUSTABLE FROM Model # BWA014K-BLU-CTS

ANCHORAGE STRAPS INSTRUCTION MANUAL THE INSTRUCTIONS APPLY THE FOLLOWING MODELS:

Subject: Certification / Inspection Frequency

Transcription:

Fasten-In-Place Bases Model Numbers: See Figure 1 The Ultimate in Fall Protection User Instruction Manual CAPITAL SAFETY This manual is intended to meet industry standards, including ANSI Z359.1, as well as local, state and federal (OSHA1910.66, 1926.502, and CSA in Canada), and should be used as part of an employee training program as required by OSHA. WARNING: This product is to be used as part of a complete system. These instructions must be provided to the user of this equipment. The user must read and understand these instructions before using this equipment. The user must follow the manufacturer s instructions for each component of the complete system. Manufacturer s instructions must be followed for proper use and maintenance of this product. Alterations or misuse of this product, or failure to follow instructions may result in serious injury or death. IMPORTANT: If you have questions on the use, care, or suitability of this equipment for your application, contact Capital Safety. IMPORTANT: Before using this equipment record the product identification information from the ID label in the Inspection and Maintenance Log of this manual. IMPORTANT: Before installing this equipment make sure a qualified person verifies the structural integrity of the structure being mounted to.(see Applications, Specifications, Installation details in this document for installation instructions, mounting requirements and rated capacities of each Fasten-In-Place base model.) Figure 1 - Models 7400211 7400218 7400222 7400225 8530267 8530373 Form: 5903293 Rev: C Copyright 2012, DB Industries, Inc.

1.0 APPLICATION 1.1 PURPOSE: For use with Securaspan Pour-In-Place Horizontal Lifeline Systems, including 7400203. Refer to Applications, Specifications and Installation details in this document for the applications of each Fasten-In-Place base in this instruction. 1.2 LIMITATIONS: A. PERSONAL FALL ARREST SYSTEM: PFAS s used with this system must meet applicable OSHA, state, federal, and ANSI requirements. PFAS s incorporating a full body harness must be capable of arresting a worker s fall with a maximum arresting force appropriate for the set up of this system. B. ENVIRONMENTAL HAZARDS: Use of this equipment in areas where environmental hazards exist may require additonal precautions be taken to reduce the possiblity of injury to the user or damage to the equipment. Hazards may include, but are not limited to: heat (welding, cutting), extreme cold, caustic chemicals, corrosive environments, high voltage power lines, explosive or toxic gases, moving machinery, or sharp edges. Contact Capital Safety if you have questions about using this equipment where environmental hazards exist. This system cannot be used where the davit mast cannot be perpendicular to the work surface. C. TRAINING: This equipment must be installed and used by persons who have been properly trained in its correct application and use. Installation and use of this equipment must be supervised by a qualified person 1, as defined by OSHA fall protection standards. 1.3 APPLICABLE STANDARDS: Refer to local standards,national standards, and OSHA requirements for more information on the application of this and associated equipment. 2.0 SYSTEM LIMITATIONS & REQUIREMENTS Always consider the following limitations/requirements when installing or using this equipment: 2.1 COMPATIBILITY OF COMPONENTS: Capital Safety equipment is designed for use with Capital Safety approved components and subsystems only. Substitutions or replacements made with non-approved components or subsystems may jeopardize compatibility of equipment and may effect the safety and reliability of the complete system. 2.2 COMPATIBILITY OF CONNECTORS: Connectors are considered to be compatible with connecting elements when they have been designed to work together in such a way that their sizes and shapes do not cause their gate mechanisms to inadvertently open regardless of how they become oriented. Contact Capital Safety if you have any questions about compatibility. Connectors (hooks, carabiners, and D-rings) must be capable of supporting at least 5,000 lbs. (22.2kN). Connectors must be compatible with the anchorage or other system components. Do not use equipment that is not compatible. Non-compatible connectors may unintentionally disengage (see Figure 2). Connectors must be compatible in size, shape, and strength. Self-locking snap hooks and carabiners are required by ANSI Z359.1, OSHA and CSA Z259.12 in Canada. 2.3 MAKING CONNECTIONS: Use only self-locking snap hooks and carabiners with this equipment. Only use connectors that are suitable to each application. Ensure all connections are compatible in size, shape and strength. Do not use equipment that is not compatible. Ensure all connectors are fully closed and locked. DBI-SALA connectors (snap hooks and carabiners) are designed to be used only as specified in each product s user s instructions. See Figure 3 for illustration of the inappropriate connections stated below. DBI-SALA snap hooks and carabiners should not be connected: A. To a D-ring to which another connector is attached. B. In a manner that would result in a load on the gate. C. In a false engagement, where features that protrude from the snap hook or carabiner catch on the anchor and without visual confirmation seems to be fully engaged to the anchor point. D. To each other. E. Directly to webbing or rope lanyard or tie-back (unless the manufacturer s instructions for both the lanyard and connector specifically allow such a connection). F. To any object which is shaped or dimensioned such that the snap hook or carabiner will not close and lock, or that roll-out could occur. 1 A person with a recognized degree or professional certificate and with extensive knowledge, training, and experience in the fall protection and rescue field who is capable of designing, analyzing, evaluating and specifying fall protection and rescue systems to the extent required by applicable standards. 2

G. In a manner that does not allow the connector to align with the fall arrest device (i.e., lanyard) while under load. NOTE: Other than 3,600 lb. (16 kn) gated hooks, large throat opening snap hooks should not be connected to standard size D-rings or similar objects which will result in a load on the gate if the hook or D-ring twists or rotates. Large throat snap hooks are designed for use on fixed structural elements such as rebar or cross members that are not shaped in a way that can capture the gate of the hook. Figure 2- Unintentional Disengagement (Rollout) If the connecting element to which a snap hook (shown) or carabiner attaches is undersized or irregular in shape, a situation could occur where the connecting element applies a force to the gate of the snap hook or carabiner. This force may cause the gate (of either a selflocking or a non-locking snap hook) to open, allowing the snap hook or carabiner to disengage from the connecting point. Small ring or other non-compatibly shaped element Figure 3 - Inappropriate Connections 1. Force is applied to the Snap Hook. 2. The Gate presses against the Connecting Ring. 3. The Gate opens allowing the Snap Hook to slip off. 2.4 OTHER RESTRICTIONS: Do not make connections where the hook locking mechanism can come into contact with a structural member or other equipment and potentially release the hook. Do not connect a snap hook into a loop or thimble of a wire rope or attach in any way to a slack wire rope. The snap hook must be free to align with the applied load as intended (regardless of the size or shape of the mating connector). A carabiner may be used to connect to a single or pair of soft loops on a body support such as a body belt or full body harness, provided the carabiner can fully close and lock. This type of connection is not allowed for snap hooks. A carabiner may be connected to a loop or ring connector that is already occupied by a choker style connector. This type of connection is not allowed for snap hooks. 2.5 STRUCTURE LOAD: Structure load requirements for each Fasten-In-Place base model are described in Section 7 of this instruction. 3

3.0 SYSTEM USE WARNING: Do not alter or intentionally misuse this equipment. Consult Capital Safety when using this equipment in combination with components or subsystems other than those described in this manual. Some subsystem and component combinations may interfere with the operation of this equipment. Use caution when using this equipment around moving machinery, electrical hazards, chemical hazards, and sharp edges. 3.1 BODY SUPPORT: When using this Capital Safety system it is recommended that a full body harness be worn. For general fall protection use, connect to the D-ring on the back between the shoulders (Dorsal D-ring). 3.2 NORMAL OPERATION: If a fall has been arrested, the system must be taken out of service and inspected, see Section 5.0. 4.0 TRAINING 4.1 It is the responsiblity of all users of this equipment to understand these instructions, and are trained in the correct installation, use, and maintenance of this equipment. These individuals must be aware of the consequences of improper installation or use of this equipment. This user manual is not a substitute for a comprehensive training program. Training must be provided on a periodic basis to ensure proficiency of the users. 5.0 INSPECTION 5.1 BEFORE EACH INSTALLATION: Inspect this system and other system components according to these or other manufacturer s instructions. System components must be formally inspected by a qualified person (other than the user) at least annually. Formal inspections should concentrate on visible signs of deterioration or damage to the system components. Items found to be defective must be replaced. Do not use components if inspection reveals an unsafe or defective condition. Record results of each inspection in the Inspection and Maintenance Log in this manual. IMPORTANT: If this equipment has been subjected to forces resulting from the arrest of a fall, it must be immediately removed from service and destroyed or returned to Capital Safety for possible repair. 5.2 INSPECTION STEPS: Step 1: Step 2: Step 3: Ensure the system is free of cracks, dents, distortion, or any other damage. Inspect for corrosion or rust All labels must be present and fully legible. 5.2 If inspection reveals an unsafe or defective condition, remove the unit from service and destroy, or contact Capital Safety for possible repair. 5.2 USER EQUIPMENT: Inspect each system component or subsytem (i.e. SRL, full body harness, lanyard, lifeline, etc.) per associated manufacturer s instructions. Refer to manufacturer s instruction supplied with each system component for inspection procedure. 6.0 MAINTENANCE, SERVICE, AND STORAGE 6.1 If components become heavily soiled with grease, paint, or other substances, clean with appropriate cleaning solutions. Do not use caustic chemicals that could damage system components. 7.0 FASTEN-IN-PLACE BASE MODELS IN THIS INSTRUCTION 8530373 Fasten-In-Place Clamp-On Vertical Base 7400211 Fasten-In-Place Clamp-On Vertical Base 7400218 Fasten-In-Place Bolt-On Vertical Base 7400222 Fasten-In-Place Weld-On Vertical Base 7400225 Fasten-In-Place Bolt-On Vertical Base 8530267 Fasten-In-Place Bolt-On Floor Base 4

7400211 FASTEN-IN-PLACE BASE APPLICATION, SPECIFICATIONS, INSTALLATION APPLICATION The 7400211 Fasten-In-Place Clamp-On Vertical Base is designed to bolt around an existing vertical steel or concrete structure and is to be used with Securaspan Fasten-In-Place Horizontal Lifeline Systems, including the 7400203 DBI-SALA Horizontal Lifeline System. SPECIFICATIONS Dimensional Capacity System Capacity Weight Fits up to 6.72 in. (17.1 cm) wide X 12.22 in. (31.0 cm) high X 5.50 in. (14.0 cm) through 6.5 in. (16.5 cm) deep. 310 lbs (141 kg) for each person when used with Securaspan Post Horizontal Lifeline (HLL) system. 80 lbs. (36 Kg) MATERIALS AND CONSTRUCTION 6.50 in 16.5 cm See Note General Construction Weld Certification Structure Material Finish Welded Steel AWS A-36 Steel Plate Zinc Plate Per ASTM B633 12.22 in 31.0 cm 7.5 in 19.1 cm 16 in 40.6 cm 5.5 in 13.9 cm.5 in / 13 mm MOUNTING REQUIREMENTS (MINIMUM) The structure and mounting hardware (base 7400211 includes mounting hardware) must be capable of supporting a minimum moment load of 390,000 in*lb. (44,064 N*m) without deformation. Installation MUST BE approved to local regulations by a qualified engineer. APPLICATION RESTRICTIONS 1. Bases are for use with Securaspan posts and accessories manufactured by DBI-SALA only. 2. If structure material does not meet minimum requirements, reinforcement MUST BE added to meet mimimum requirements. 3. Each installation MUST BE approved to local regulations by a qualified engineer. 6.72 in 17.0 cm 10 in 25.4 cm 2 in 5.1 cm NOTE: 7400211 base includes four part number 8526654 bolts, HH, 3/4-10 X 9, ZP, GR8, 9 in. (22.9 cm). Bolt end is threaded 2 in. (5.1 cm). For additional dimensional capacity, substitute your own 3/4 in. (19 mm) grade 8 hardware. 5

7400211 FASTEN-IN-PLACE BASE APPLICATION, SPECIFICATIONS, INSTALLATION INSTALLATION FASTEN STANCHION BASE AROUND STRUCTURE: Fasten the Stanchion Base around an existing vertical steel or concrete structure using the included hardware. Maximum dimensions of structure that can be captured by the 7400211 Fasten-In-Place base frame: A. 6.72 in (17.1 cm) maximum width B. 12.22 in (31.0 cm) maximum height C. 6.50 in (16.5 cm) maximum depth See illustration below. Torque hardware to a minimum of 130 ft*lbs (176 N*m). For additional mounting depth capacity, replace the four 9 in. (22.9 cm) bolts (D) supplied with the base with longer 3/4 in. (19 mm) grade 8 (minimum) bolts or threaded rods. A B C D LABELS This label must be present and fully legible: 6

7400218 FASTEN-IN-PLACE BASE APPLICATION, SPECIFICATIONS, INSTALLATION APPLICATION The 7400218 Fasten-In-Place Bolt-On Vertical Base is designed to bolt to an existing vertical steel or concrete structure and is to be used with Securaspan Fasten-In-Place Horizontal Lifeline Systems, including the 7400203 DBI-SALA Horizontal Lifeline System. SPECIFICATIONS System Capacity Weight 310 lbs (141 kg) for each person when used with Securaspan Post Horizontal Lifeline (HLL) system. 24 lbs. (11 Kg) MATERIALS AND CONSTRUCTION 7.5 in 19.1 cm General Construction Weld Certification Structure Material Finish Welded Steel AWS A-36 Steel Plate Zinc Plate Per ASTM B633 MOUNTING REQUIREMENTS (MINIMUM) 13 in 33.0 cm 16 in 40.6 cm 5.5 in 13.9 cm.5 in / 13 mm 2 in 5.1 cm The structure and mounting hardware must be capable of supporting a minimum moment load of 390,000 in*lb. (44,064 N*m) without deformation. Installation MUST BE approved to local regulations by a qualified engineer. APPLICATION RESTRICTIONS 1. Bases are for use with Securaspan posts and accessories manufactured by DBI-SALA only. 2. If structure material does not meet minimum requirements, reinforcement MUST BE added to meet mimimum requirements. 3. Each installation MUST BE approved to local regulations by a qualified engineer. 7.5 in 19.1 cm 10 in 25.4 cm NOTE: 3/4 in. (19 mm) grade 8 (minimum) hardware is required for installation. 7

7400218 FASTEN-IN-PLACE BASE APPLICATION, SPECIFICATIONS, INSTALLATION INSTALLATION FASTEN THE BOLT-ON VERTICAL BASE TO STRUCTURE: Fasten the Stanchion Base to an existing vertical steel or concrete structure using 3/4 in. (19 mm) grade 8 (minimum) hardware (not included). See illustration below. Torque hardware to a minimum of 130 ft*lbs (176 N*m). LABELS This label must be present and fully legible: 8

7400222 FASTEN-IN-PLACE BASE APPLICATION, SPECIFICATIONS, INSTALLATION APPLICATION The 7400222 Fasten-In-Place Weld-On Vertical Base is designed to be welded to an existing vertical steel structure and is to be used with Securaspan Fasten-In-Place Horizontal Lifeline Systems, including the 7400203 DBI-SALA Horizontal Lifeline System. SPECIFICATIONS System Capacity Weight 310 lbs (141 kg) for each person when used with Securaspan Post Horizontal Lifeline (HLL) system. 50 lbs. (23 Kg) 6 in 15.2 cm 2.25 in 5.7 cm.5 in / 13 mm 11 in 27.9 cm 5.5 in 13.9 cm 9.25 in 23.5 cm 1.25 in / 3.2 cm MATERIALS AND CONSTRUCTION General Construction Weld Certification Structure Material Finish Welded Steel AWS A-36 Steel Plate Zinc Plate Per ASTM B633 MOUNTING REQUIREMENTS (MINIMUM) The structure and mounting hardware must be capable of supporting a minimum moment load of 390,000 in*lb. (44,064 N*m) without deformation. Installation MUST BE approved to local regulations by a qualified engineer. APPLICATION RESTRICTIONS 1. Bases are for use with Securaspan posts and accessories manufactured by DBI-SALA only. 2. System design factor depends on other system components and the configuration in which they are assembled. The minimum design factor for all standard Advanced Safety Systems masts and accessories is 4:1. 3. All welding is to be carried out by qualified personnel. 4. If structure material does not meet minimum requirements, reinforcement MUST BE added to meet mimimum requirements. 5. Each installation MUST BE approved to local regulations by a qualified engineer. 9

7400222 FASTEN-IN-PLACE BASE APPLICATION, SPECIFICATIONS, INSTALLATION INSTALLATION WELD THE WELD-ON VERTICAL BASE TO STRUCTURE: The Weld-On Base must be welded to an existing vertical steel structure. The weld bead (A) must run the entire length of both C-Channels as shown in the illustration below. Weld must be able to hold a 390,000 in lb (4,407 N*m) moment load. A A A A LABELS This label must be present and fully legible: 10

7400225 FASTEN-IN-PLACE BASE APPLICATION, SPECIFICATIONS, INSTALLATION APPLICATION The 7400225 Fasten-In-Place Bolt-On Vertical Base is designed to bolt to an existing vertical steel or concrete structure and is to be used with Securaspan Fasten-In-Place Horizontal Lifeline Systems, including the 7400203 DBI-SALA Horizontal Lifeline System. SPECIFICATIONS System Capacity Weight 310 lbs (141 kg) for each person when used with Securaspan Post Horizontal Lifeline (HLL) system. 24 lbs. (11 Kg) MATERIALS AND CONSTRUCTION General Construction Weld Certification Welded Steel AWS 13 in 33.0 cm 7.5 in 19.1 cm 16 in 40.6 cm 5.5 in 13.9 cm.5 in / 13 mm Structure Material 304 Stainless Steel MOUNTING REQUIREMENTS (MINIMUM) The structure and mounting hardware must be capable of supporting a minimum moment load of 390,000 in*lb. (44,064 N*m) without deformation. Installation MUST BE approved to local regulations by a qualified engineer. APPLICATION RESTRICTIONS 1. Bases are for use with Securaspan posts and accessories manufactured by DBI-SALA only. 2. If structure material does not meet minimum requirements, reinforcement MUST BE added to meet mimimum requirements. 3. Each installation MUST BE approved to local regulations by a qualified engineer. 2 in 5.1 cm 7.5 in 19.1 cm 10 in 25.4 cm NOTE: 3/4 in. (19 mm) grade 8 (minimum) hardware is required for installation. 11

7400225 FASTEN-IN-PLACE BASE APPLICATION, SPECIFICATIONS, INSTALLATION INSTALLATION FASTEN THE BOLT-ON VERTICAL BASE TO STRUCTURE: Fasten the Stanchion Base to an existing vertical steel or concrete structure using 3/4 in. (19 mm) grade 8 (minimum) hardware (not included). See illustration below. Torque hardware to a minimum of 130 ft*lbs (176 N*m). LABELS This label must be present and fully legible: 12

8530267 FASTEN-IN-PLACE BOLT-ON FLOOR BASE APPLICATION, SPECIFICATIONS, INSTALLATION APPLICATION The 8530267 Fasten-In-Place Bolt-On Floor Base is designed to be bolted to existing steel or concrete horizontal surfaces and is to be used with Securaspan Fasten-In-Place Horizontal Lifeline Systems, including the 7400203 DBI-SALA Horizontal Lifeline System. SPECIFICATIONS System Capacity Weight 310 lbs (141 kg) for each person when used with Securaspan Post Horizontal Lifeline (HLL) system. 75 lbs. (34 Kg) 14 in 35.6 cm 18 in 45.7 cm 2 in 5.1 cm 12.0 in 30.5 cm 8.0 in 20.3 cm 15.5 in 39.4 cm MATERIALS AND CONSTRUCTION General Construction Weld Certification Structure Material Finish Welded Steel AWS A-36 Steel Plate Zinc Plate Per ASTM B633 MOUNTING REQUIREMENTS (MINIMUM) The structure and mounting hardware must be capable of supporting a minimum moment load of 390,000 in*lb. (44,064 N*m) and a 5,000 lb (2268 kg) vertical load. Anchors used to mount this base must have an installed minimum pull-out strength of 19,500 (86.8 kn) and a shear strength of 5,000 lb (22.2 kn). Installation MUST BE approved to local regulations by a qualified engineer. APPLICATION RESTRICTIONS 1. Bases are for use with Securaspan posts and accessories manufactured by DBI-SALA only. 2. If structure material does not meet minimum requirements, reinforcement MUST BE added to meet mimimum requirements. 3. Each installation MUST BE approved to local regulations by a qualified engineer. NOTE: 3/4 in. (19 mm) grade 8 (minimum) hardware is required for installation. 13

8530267 FASTEN-IN-PLACE BOLT-ON FLOOR BASE INSTALLATION APPLICATION, SPECIFICATIONS, INSTALLATION BOLT THE BOLT-ON FLOOR BASE TO STRUCTURE: Fasten the Bolt-On Floor Base around an existing steel or concrete horizontal surface using 3/4 in. (19 mm) grade 8 (minimum) hardware (not included). LABELS This label must be present and fully legible: 14

8530373 FASTEN-IN-PLACE BASE APPLICATION, SPECIFICATIONS, INSTALLATION APPLICATION The 8530373 Fasten-In-Place Clamp-On Vertical Base is designed to bolt around an existing steel or concrete structure and is to be used with Securaspan Pour-In-Place Horizontal Lifeline Systems, including the 7400203 DBI-SALA Horizontal Lifeline System. SPECIFICATIONS Dimensional Capacity System Capacity Weight Fits up to 8.13 in. (20.1 cm) wide X 12.22 in. (31.0 cm) high X 10.94 in. (27.8 cm) through 11.94 in. (30.3 cm) deep. 310 lbs (141 kg) for each person when used with Securaspan Post Horizontal Lifeline (HLL) system. 85 lbs. (39 Kg) MATERIALS AND CONSTRUCTION 11.94 in 30.3 cm (See Note) 7.5 in 19.1 cm 16 in 40.6 cm.5 in / 13 mm General Construction Weld Certification Structure Material Finish Welded Steel AWS A-36 Steel Plate Zinc Plate Per ASTM B633 MOUNTING REQUIREMENTS (MINIMUM) The structure and mounting hardware (base 8530373 includes mounting hardware) must be capable of supporting a minimum moment load of 390,000 in*lb. (44,064 N*m) without deformation. Installation MUST BE approved to local regulations by a qualified engineer. APPLICATION RESTRICTIONS 1. Bases are for use with Securaspan posts and accessories manufactured by DBI-SALA only. 2. If structure material does not meet minimum requirements, reinforcement MUST BE added to meet mimimum requirements. 3. Each installation MUST BE approved to local regulations by a qualified engineer. 12.22 in 31.0 cm 5.5 in 13.9 cm 8.13 in 20.1 cm 10 in 25.4 cm 2 in 5.1 cm NOTE: 8530373 base includes four part number 9506699 bolts, HH, 3/4-10 X 15, ZP, GR8, 15 in. (38.1 cm). Bolt end is threaded 2 in. (5.1 cm). For additional dimensional capacity, substitute your own 3/4 in. (19 mm) grade 8 hardware. 15

8530373 FASTEN-IN-PLACE BASE APPLICATION, SPECIFICATIONS, INSTALLATION INSTALLATION FASTEN STANCHION BASE AROUND STRUCTURE: Fasten the Stanchion Base around the existing structure using the included hardware. Maximum dimensions of structure that can be captured by the 8530373 Fasten-In-Place base frame: A. 8.13 in (20.1 cm) maximum width B. 12.22 in (31.0 cm) maximum height C. 11.94 in (30.3 cm) maximum depth See illustration below for an example of mounting the base to an ibeam. Torque hardware to a minimum of 130 ft*lbs (176 N*m). For additional mounting depth capacity, replace the four 15 in. (38.1 cm) bolts (D) supplied with the base with longer 3/4 in. (19 mm) bolts or threaded rods. A B C D LABELS These labels must be present and fully legible: 16

INSPECTION AND MAINTENANCE LOG SERIAL NUMBER: MODEL NUMBER: DATE PURCHASED: DATE OF FIRST USE: INSPECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED 17

INSPECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED 18

19

LIMITED LIFETIME WARRANTY Warranty to End User: D B Industries, Inc., dba CAPITAL SAFETY USA ( CAPITAL SAFETY ) warrants to the original end user ( End User ) that its products are free from defects in materials and workmanship under normal use and service. This warranty extends for the lifetime of the product from the date the product is purchased by the End User, in new and unused condition, from a CAPITAL SAFETY authorized distributor. CAPITAL SAFETY S entire liability to End User and End User s exclusive remedy under this warranty is limited to the repair or replacement in kind of any defective product within its lifetime (as CAPITAL SAFETY in its sole discretion determines and deems appropriate). No oral or written information or advice given by CAPITAL SAFETY, its distributors, directors, officers, agents or employees shall create any different or additional warranties or in any way increase the scope of this warranty. CAPITAL SAFETY will not accept liability for defects that are the result of product abuse, misuse, alteration or modification, or for defects that are due to a failure to install, maintain, or use the product in accordance with the manufacturer s instructions. CAPITAL SAFETY S WARRANTY APPLIES ONLY TO THE END USER. THIS WARRANTY IS THE ONLY WARRANTY APPLICABLE TO OUR PRODUCTS AND IS IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES, EXPRESSED OR IMPLIED. CAPITAL SAFETY EXPRESSLY EXCLUDES AND DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND SHALL NOT BE LIABLE FOR INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY NATURE, INCLUDING WITHOUT LIMITATION, LOST PROFITS, REVENUES, OR PRODUCTIVITY, OR FOR BODILY INJURY OR DEATH OR LOSS OR DAMAGE TO PROPERTY, UNDER ANY THEORY OF LIABILITY, INCLUDING WITHOUT LIMITATION, CONTRACT, WARRANTY, STRICT LIABILITY, TORT (INCLUDING NEGLIGENCE) OR OTHER LEGAL OR EQUITABLE THEORY. The Ultimate in Fall Protection CSG USA & Latin America 3833 SALA Way Red Wing, MN 55066-5005 Toll Free: 800.328.6146 Phone: 651.388.8282 Fax: 651.388.5065 solutions@capitalsafety.com CSG Canada 260 Export Boulevard Mississauga, ON L5S 1Y9 Phone: 905.795.9333 Toll-Free: 800.387.7484 Fax: 888.387.7484 info.ca@capitalsafety.com CSG Northern Europe 5a Merse Road North Moons, Moat Reditch, Worcestershire, UK B98 9HL Phone: + 44 (0)1527 548 000 Fax: + 44 (0)1527 591 000 csgne@capitalsafety.com CSG EMEA (Europe, Middle East, Africa) Le Broc Center Z.I. 1ère Avenue 5600 M B.P. 15 06511 Carros Le Broc Cedex France Phone: + 33 4 97 10 00 10 Fax: + 33 4 93 08 79 70 information@capitalsafety.com CSG Australia & New Zealand 95 Derby Street Silverwater Sydney NSW 2128 AUSTRALIA Phone: +(61) 2 8753 7600 Toll-Free : 1 800 245 002 (AUS) Toll-Free : 0800 212 505 (NZ) Fax: +(61) 2 8753 7603 sales@capitalsafety.com.au CSG Asia Singapore: 16S, Enterprise Road Singapore 627666 Phone: +65-65587758 Fax: +65-65587058 inquiry@capitalsafety.com Shanghai: Rm 1406, China Venturetech Plaza 819 Nan Jing Xi Rd, Shanghai 200041, P R China Phone: +86 21 62539050 Fax: +86 21 62539060 www.capitalsafety.com I S O 9001