Recommendation on the monitoring of critical control points for the use of dispensing systems for pre-moistened surface disinfectant wipes 1

Similar documents
Suction Regulators. Recommendations for Cleaning, Disinfection and Reprocessing: Boehringer 3800 &3900 Series Suction Regulators

Client Care Items and Equipment

Developing a HACCP plan

1 in 4 patients will contract an HAI during their hospital stay. were prevented, annual cost savings would be $11.3 billion.

Hazard and risk analysis in pharmaceutical products 1

Section 3-5: Principle 3: Determine Critical Limits

Best Practice in the Breeder House

Legionella Guidance. Property managers specialising in residential, apartment, block and estate management

LEGIONELLA MANAGEMENT PROCEDURE

Tools to Enhance Laboratory Biosafety and Biosecurity Performing Risk Assessments

CLEANING AND SANITIZING

Competency Record for Sonic Cleaning

INFORMATION NOTE No 353: MICROBIOLOGICAL TESTING

Hospital Surface Disinfection: Need, Gaps, Challenges and Management for "Basin and Mop" Method

1 in 4 patients will contract an HAI during their hospital stay. were prevented, annual cost savings would be $11.3 billion.

CORESTA GUIDE N 12. May 2013 CONTROLLED ATMOSPHERE PARAMETERS FOR THE CONTROL OF CIGARETTE BEETLE AND TOBACCO MOTH

Water Hygiene Chlorination Water Treatment Legionella Control

CLEANING AND DISINFECTION TECHNIQUES. Barbara Wessels Key Account Manager Ecolab Life Sciences 4 October 2017

SUGGESTED POLICY FOR THE MONITORING OF THE CLEANING EFFICIENCY OF AN ULTRASONIC CLEANERS( SONIC & TOSI) WEEKLY

PIQCS HACCP Minimum Certification Standards

Ritter AquaBottleSystem

AquaSPArkle Hot Tub and Spa Guide

Farm Chlor Chlorinator Instruction Manual

PRODUCT HEALTH AND SAFETY DATA SHEET "APERLAN Poka-Yoke agent A"

Spirometry. Operating Manual. Part 4: Hygiene and disinfection for custo spiro mobile. Operating characteristics:

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

HAZARD ANALYSIS AND CRITICAL CONTROL POINT PRINCIPLES AND APPLICATION GUIDELINES

Choosing and Installing Microbiological Safety Cabinets

7. DEVELOPMENT OF HACCP WORKSHEET AND PLAN FORM

Qualification Specification HABC Level 2 Award in Legionella Awareness (QCF)

TJF-Q180V Cleaning and Disinfection Checklist

Shukla Medical. TITLE: Manual Surgical Orthopedic Instruments Recommendations for Care, Cleaning, Maintenance and Sterilization

High Pressure Asher HPA-S

Health risks posed by unregulated Water Park Installations in NSW

ASX Announcement. Target Energy Fairway Reserves Update. Corporate information. 20 September 2017

Legionella, Pseudomonas and general pathogen control in water systems

TJF-Q180V Cleaning and Disinfection Checklist

Validation of a Neutral Pressure Isolation Room

Solenoid Valves used in Safety Instrumented Systems

Safety Services. Introduction

Personal Protective Equipment

WELCOME NEW FOOD/POOL SAFETY TEAM

INTERNATIONAL OLYMPIC COMMITTEE IOC DISCIPLINARY COMMISSION DECISION REGARDING VITA PALAMAR BORN ON 12 OCTOBER 1977, UKRAINE, ATHLETE, ATHLETICS

Chlorination Manual. I. Before going to the field. II. In the field. Sierra Leone

What s in the water The importance of bather hygiene and cleanliness. Luke Griffiths STA s Technical Manager for Pool Plant

National surveillance services a helpful investment in educating healthcare professionals

Determination of Retest Periods of Composite Pressure Receptacles

INTERNATIONAL LIFE SAVING FEDERATION LIFESAVING POSITION STATEMENT - LPS 19 USE OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

SAFETY DATA SHEET Product Name: Monk Disinfectant Wipes

wipers tested, KIMTECH PREP * Wipers for Bleach, control practices. PREP * Wipers for Bleach, Disinfectants and Sanitizers used

Illinois Institute of Technology Institutional Review Board Handbook of Procedures for the Protection of Human Research Subjects

Legionella Policy. Policy Ref: PS08. Prepared By. Georgina Kent, Operations Director. Date of Current Review August 2018

REVACIL POOL CARE GUIDE THE CHLORINE FREE SWIMMING POOL PROGRAMME

BCGA GUIDANCE NOTE 17

Crypto Outbreak Collection

Introduction. Legal Duties. Risk Assessment

Type C-CUT. Quickstart. English Deutsch Français

OECD GUIDANCE DOCUMENT FOR DEMONSTRATING EFFICACY OF POOL AND SPA DISINFECTANTS IN LABORATORY AND FIELD TESTING

Liberian Administration s Implementing the ILO a Maritime Labour Convention, 2006 MLC Title 3. Accommodation, Catering

Mission of the Community Veterinary Emergency Team to LITHUANIA

FIRST AID POLICY NOVEMBER 2017

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

DURABILITY OF ROCKFON HYDROCLEAN BOARD. Resistance to active chlorine disinfectant in high concentration

Translation of the original Operating Instructions for HKS rubber compensators

Environmental Engineering-I By Prof S S JAHAGIRDAR

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

Legionnaires disease: Technical guidance Part 3: The control of legionella bacteria in other risk systems

Application of nanosilver in swimming pool water treatment technology

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Aseptic processing. the starting material to the finished product, should be controlled by Validation Control of the aseptic process

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve

Medical Surfaces ATP Study

INFECTION PREVENTION AND CONTROL POLICY AND PROCEDURES Sussex Partnership NHS Foundation Trust (The Trust) IPC4 DECONTAMINATION OF MEDICAL EQUIPMENT

Bhagwant N. Persaud* Richard A. Retting Craig Lyon* Anne T. McCartt. May *Consultant to the Insurance Institute for Highway Safety

No. 2 TEST WEIGHT ASSESSMENT

Simplified Start-Up Checklist For Fully-Pressurized Seasonal Systems

Use of Biosafety II cabinets

Big Wipes 4x4 Health & Safety Data Sheet

Health & Safety Policy HSP 07 Legionella Management Version Status Date Title of Reviewer Purpose/Outcome

v /07/17 Page 1 of 18

Dev Food Industry. Procedure for HACCP Plan. To establish and maintain a uniform approach to establish HACCP Plan.

GSA POLICY ON LOCAL EXHAUST AND OTHER VENTILATION (FUME CUPBOARDS)

Safety manual for Fisher GX Control Valve and Actuator

INTERNATIONAL OLYMPIC COMMITTEE IOC DISCIPLINARY COMMISSION DECISION REGARDING IRYNA KULESHA BORN ON 26 JUNE 1986, BELARUS, ATHLETE, WEIGHTLIFTING

DeZURIK Double Block & Bleed (DBB) Knife Gate Valve Safety Manual

REVISITING THE HAZARD ANALYSIS. John E. Rushing, Ph.D. Professor Emeritus, North Carolina State University Principal, Food Technology Consulting, LLC

Material Safety Data Sheet Protective Welding Spray

GUIDE TO LEGIONELLOSIS - Risk Assessment

GENERAL SAFETY INSTRUCTION GSI-M-2 STANDARD PRESSURE EQUIPMENT

NeoNatalie Resuscitator Oxygen kit

Introduction. Seafood HACCP Alliance Training Course 8-1

VDMA VDMA-Einheitsblatt December 2014 VDMA 15390: Continued page 2 to 31. Verband Deutscher Maschinen- und Anlagenbau e.v.

The German Spatial Data Strategy

Prevention and Control of Legionella Policy

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Page: 1 of 8 Version: 1.9 Revision Date: 06/24/2014 SILA-SEAL CLEAR INDUSTRIAL GRADE SILICONE SEALANT. MSDS No.: Revision Date: 06/24/2014

18000 RIMSTAD INDEPENDENT CONTINENTAL COMPARTMENT

Hospitals. Hydrotherapy

BCAC ANTI DOPING POLICY

CONTROL OF LEGIONELLA POLICY

Transcription:

VAH Disinfectants Commission 2012: Pre-moistened surface disinfectant wipes 1 Disinfectants Commission in the Association for Applied Hygiene (VAH) in collaboration with the 4+4 Working Group Recommendation on the monitoring of critical control points for the use of dispensing systems for pre-moistened surface disinfectant wipes 1 1 Background The basis for this recommendation by the VAH Disinfectants Commission is the recommendation Hygiene Requirements on Surface Cleaning and Disinfection which was published by the Commission for Hospital Hygiene (KRINKO) of the German Federal Robert Koch Institute (RKI) in 2004 (1). Amongst other things, this recommendation lists as a requirement: Ready-to-use solutions of disinfectants must be used for one working day at most (Cat. IB). At the time when the KRINKO recommendation was published, the special implications of dispensing systems for pre-moistened surface disinfectant wipes were not taken into account because wipes had not been used on a broader basis. Meanwhile, however, wipes are being used widely with good compliance especially for the nearpatient environment. Contrary to the requirement mentioned above, stating that readyto-use solutions may be used for just one working day at most, instructions provided by the manufacturers recommend application of wipes wetted with VAH-listed disinfectants from dispensers for a period of up to 28 days. The preface for the chapter on surface disinfection in the VAH List of Disinfectants says If not available as such (i.e. pre-prepared wipes), the working solutions should as a rule be freshly prepared; this always applies for disinfectants based on peroxide compounds and on chlorine releasing compounds (2). It continues Any working solutions left over must not be allowed to stand for a long time (at most one working day, observe instructions provided by the manufacturer). Hence, pre-moistened surface disinfectant wipes from bucket dispensers have not yet been included in the pertinent lists of disinfectants tested and deemed to be effective because validated test procedures for this mode of application are still lacking. 1 English translation of the German original publication Empfehlung zur Kontrolle kritischer Punkte bei der Anwendung von Tuchspendersystemen im Vortränksystem für die Flächendesinfektion. HygMed. 2012;37(11):468-469. VAH e.v.

VAH Disinfectants Commission 2012: Pre-moistened surface disinfectant wipes 2 The effectiveness of pre-moistened wipes in these bucket dispensers and the use specifications listed by VAH refer only to tests of the solutions but not to the efficacy of surface disinfection procedures applying pre-moistened wipes with a reuse period of up to 28 days. Thus, current dispenser systems for pre-moistened surface disinfectant wipes are a recent development which have neither been reflected in the KRINKO recommendations for cleaning and disinfection of surfaces nor in the test methods of VAH for assessing disinfectant efficacy, in particular with respect to longer reuse periods. So far information concerning their effectiveness solely refers to data provided by the manufacturers. Since meanwhile pre-moistened surface disinfectant wipes from bucket dispensers are being used widely, the VAH Disinfectants Commission deems it necessary to provide guidance for the selection and use of these dispenser systems. The VAH Disinfectants Commission currently concerns itself with methods for testing dispensing systems for pre-moistened wipes with long reuse periods. In the past, insufficient use concentrations for surface disinfection and cleaning have led to infections and outbreaks of nosocomial infections time and again. As of now, however, epidemiological evidence concerning the causal implications of dispensing systems for pre-moistened wipes has not been reported neither for sporadic nosocomial infections nor for outbreaks of nosocomial infections. However, it cannot be excluded that dispensing systems for pre-moistened wipes have not been systematically examined and/or taken into consideration as an infection reservoir for nosocomial outbreaks. There are, however, sporadic reports of contaminated bucket dispensers in real-life use, prompting the VAH Disinfectants Commission to perform a hazard analysis and publish critical control points. 2 Critical control points for the use of pre-moistened disinfectant wipes from dispensing systems According to the HACCP concept, critical control points include: 2.1 Use of disinfectant solutions already contaminated at the time of (re)filling the bucket dispensers Contamination of disinfectant solutions to be filled in the containers (buckets) of dispensers for pre-wetting the wipes which may occur e.g. if dosing units or potable water taps used to prepare the disinfection solution are contaminated with biofilms may result in contamination of the wipes pre-moistened with this disinfectant. Contamination with biofilm flakes is associated with the risk of pathogen persistence and subsequent tolerance against the specific disinfection procedure being used. For this reason, as specified by KRINKO, contamination of the disinfectant solution must be minimised during use. Therefore, prevention of biofilm formation, e.g. in dosing units or in taps which are used when adding potable water for mixing use solutions of disinfectants, is of utmost importance.

VAH Disinfectants Commission 2012: Pre-moistened surface disinfectant wipes 3 According to the KRINKO recommendation on surface cleaning and disinfection Bacterial strains with reduced susceptibility or development of tolerance, can, in principle, be selected in particular conditions (e.g. biofilm) even if the disinfectants are dosed correctly. 2.2 Use of wipes not compatible with the disinfectant More recent investigations have shown that certain wipe fabrics inactivate or reduce the effectiveness of disinfectants, especially those based on quaternary ammonium compounds. This may result in a significant loss in efficacy of the disinfectant, in particular with longer reuse periods. Therefore, compatibility of the wipe dispensing system with the disinfectant is of great importance. 2.3 Loss of effectiveness after long periods of reuse According to the KRINKO recommendation on surface cleaning and disinfection Insufficiently concentrated or ineffective disinfectant solutions, especially when prepared and stored in contaminated receptacles for a long period of time, can become a source of infection, above all containing gram-negative bacteria (above all Enterobacteriaceae, pseudomonads). Therefore, a test in order to exclude a loss of effectiveness of the disinfectant after a reuse period of up to 28 days is of utmost importance. 2.4 Loss of effectiveness due to dried out wipes In everyday use, wipes have been observed to dry out and lose their effectiveness when hanging out from a bucket when the lid is not closed. Therefore, drying out of wipes, e.g. due to incorrect sealing of the lid, must be avoided. 2.5 Contamination of wipes hanging out of the buckets In everyday use, it has not only been shown that wipes will dry out if the lid is not closed but also that there is a risk of contamination, e.g. by contact with contaminated gloves, in moist areas in particular with gram-negative bacteria. 2.6 Multiplication of gram-negative bacteria in containers During an outbreak with Klebsiella oxytoca, the pathogen was isolated from disinfectant buckets, exhibiting an increased tolerance to the disinfectant (2, 3). According to the KRINKO recommendation Buckets and other receptacles must be cleaned thoroughly after cleaning/disinfecting activities have been concluded (Cat. IB). The VAH Disinfectants Commission considers it to be prudent that containers are subjected to a disinfectant cleaning procedure after use and/or in the event of

VAH Disinfectants Commission 2012: Pre-moistened surface disinfectant wipes 4 incomplete drying immediately prior to reuse. 3 Monitoring The VAH Disinfectants Commission considers the following quality monitoring procedures to be important and recommends their rigorous implementation: 3.1 Rapid detection of the contamination of the disinfectant used for filling the container The contents of the dispensing system for pre-moistened wipes (solution and, if necessary, wipes) should be examined for contamination in the context of random inspections. 3.2 Expert evaluation of the compatibility of the wipe dispenser and the disinfectant When selecting wipes, the manufacturer of the disinfectant and/or the wipes has to provide proof that the wipe fabric does not compromise the disinfectant effectiveness during the recommended period of reuse by expert evaluation. The corresponding expert report has to be presented when selecting wipe dispensing systems. 3.3 Proof for extended periods of reuse The manufacturer of disinfectants to be used with dispensing systems for pre-moistened surface disinfectant wipes has to present proof by expert evaluation that there will not be a loss of effectiveness during the reuse period specified by the manufacturer. The employed methods for efficacy testing must simulate practice conditions. Alternatively, analytical methods may be used to document that the quantity of active ingredient released from the wipes is sufficient and that other parameters essential for effectiveness (such as ph-value) are not altered by the wipe fabric. 3.4 Requirements on the design of the container The containers for wipe dispensing systems must be designed in such a way that they are easy to close even when wipes are hanging out of the container in order to avoid both drying out and contamination of the wipes. On the other hand, lids must be easy to open so that the wipes can be pulled out without any difficulty. 3.5 Safe sealing of the lid while the dispenser is not in use A work instruction is to ensure secure sealing of the lid while the dispenser is not in use.

VAH Disinfectants Commission 2012: Pre-moistened surface disinfectant wipes 5 3.6 Processing of the buckets prior to refilling In order to prevent selection of microorganisms which are resistant to disinfectants, containers should always be subjected to a thorough disinfectant cleaning procedure after use of the last wipe and subsequently dried before refilling them with wipes and disinfectant solution. Chemo-thermal processing may be applicable. The manufacturers of the pertinent containers are asked to offer containers which may be processed in automatic washer disinfectors. 3.7 Investigations in the event of noscomial outbreaks In the event of nosocomial outbreaks, in particular with gram negative bacteria, wipe dispensing systems must be examined hygienically and microbiologically as a potential reservoir for infection. References 1. Kommission für Krankenhaushygiene und Infektionsprävention am Robert Koch-Institut (KRINKO). Anforderungen an die Hygiene bei der Reinigung und Desinfektion von Flächen. Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz. 2004;47:51-61. This Guideline was translated into English on behalf and responsibility of the German Society of Hospital Hygiene: http://www.dgkh.de/nutzerdaten/file/empfehlungen/2010_rki_cleaning.pdf. 2. Gebel J, Sonntag HG, Werner HP, Vacata V, Exner M, Kistemann T. The higher disinfectant resistance of nosocomial isolates of Klebsiella oxytoca. How reliable are indicator organisms in disinfectant testing? J Hosp Infect 2002;50(4)309 311. 3. Reiss I, Borkhard A, Fussle R, Sziegoleit A, Gortner L. Disinfectant contaminated with Klebsiella oxytoca as a source of sepsis in babies. Lancet 2000;356(9226):319. For further information, please contact: VAH e.v. Desinfektionsmittel-Kommission c/o Institut für Hygiene und Öffentliche Gesundheit der Universität Bonn Sigmund-Freud-Str. 25 53127 Bonn Germany Tel: +49 228 287-14022 Fax: +49 228 287-19522 email: info@vah-online.de www.vah-online.de Chairman: Prof. Dr. med. M. Exner Secretary: Dr. J. Gebel