PREPARATIONS FOR PIEZOCONE CPTU TESTING (De-airing and Saturating)

Similar documents
1. A proper preparation of the cone and other material is inevitable prior to a CPTU test.

Unisense In Situ UniAmp Connector System

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

easycomposites SETUP & DAILY USE INSTRUCTIONS NEVER SWITCH OFF YOUR PUMP WITHOUT FIRST CLOSING THE VALVE TO THE CHAMBER

HATFIELD. Continuing the Tradition SEMI-AUTOMATIC SHOTGUN INSTRUCTION MANUAL

Standard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442

Installation of Your SprayMaster System

Basic Flows in a Microfluidic Device

Assembling & Installing your Pool Cleaner

INSTALLATION & MAINTENANCE INSTRUCTION

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.

OWNER'S MANUAL. Copyright 2003 GAMMA - All Rights Reserved

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

PANACEA P100 LOW PRESSURE USER MANUAL

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

User s Guide. Vacuum Controller for liquid delivery systems

OWNER'S MANUAL. Copyright 1999 ATS - All Rights Reserved

In situ permeability measurement with the BAT Permeameter. Quick Manual Ou low test. Warranty details

Bulletin /06/2012 Supersedes 10/23/00. Installation of John Crane Type 73 Inflatable Mechanical Seal. Page 01 of 10

PANACEA P200 STAINLESS STEEL USER MANUAL

Standard Operating Procedure Inert Vacuum Line. Ryan Mulvenna, May 2012

Figure 1: Hydrostatic Pressure Forces Are Perpendicular to the Surface

APP pumps APP and APP Disassembling and assembling

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Operating manual for Material pressure tanks Vol./1 and Vol./2

GI Series Diaphragm Pressure Gauge Guard

User s Guide. Pressure Controller for liquid delivery systems

Unblocking the MicroSprayer Aerosolizer Model IA-1C With the High Pressure Reverse Cleaning Adapter. Instructions for Use

Read through all the steps first before working on the camera. Make sure you know what to do.

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

TOURNAMENT ICE. 8Ft-Gold Standard Manual Score Home Air Hockey Game Assembly Instructions / Manual

Calcimeter Instruction Manual

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

FOR THE PROTECTION AND DECORATIVE COLOURING OF ALUMINIUM

LAB Chip Lid Molding LAB PROCEDURE

Product Overview: Key Features:

User's Manual. MixRite TF 10. Edition 05.08

Powermax machine-side reference guide For mechanized applications with Powermax1000, Powermax1250 and Powermax1650

Overview of types. Technical data. Safety notes

Johnston Invar Coupling Johnston Invar Coupling

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

FOR THE PROTECTION AND DECORATIVE COLOURING OF ALUMINIUM

Thanks for choosing EJAI SOLAR product

Disassembling and assembling APP and APP 16-22

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

Technical Service Bulletin June 2015 TSB122.06

The pipettes cover a volume range from 0.1µl to 10ml.

8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8

We measure it. For gas and water installers. testo hpa. bar

Installation and commissioning instructions 255 series and 256 series

SSV-Actuator HON 673 (K 1a, K 2a)

Rocket Activity Rocket Wind Tunnel

Replacing the Reverse Osmosis ( RO ) Membranes

Wet Lamination of Dry Film Photoresist for the Hobbyist

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS

BSS 2 Bottle Sampling System. Instruction manual Version 1.8

Operating and maintenance manual Filter and reducing station Series / 1.0

CVC Insertion Simulator

INSTALLATION GUIDE MODEL NUMBER X. UniMaxx-Plus-SC-500-AC-V3 UNIMAXX SOLAR PUMP STATION

PANACEA P125 USER MANUAL

Model 23H Hand Crank Seamer

Arterial Puncture Wrist. Instruction Manual

Installation Procedure for your Disco Double Kit, by Airgun Lab, LLC.

Actuator HON 670 / 671

Overview of types. Technical data

Instruction Manual Updated 7/26/2011 Ver. 2.2

SRI Model H2-40 Hydrogen Generator Operation and Maintenance Nov 2006

Installation Instructions

EVO Solid Downtube. Operators Manual for Downtubes fitted with zinc plated springs June 2004

200 STRINGING MACHINE

The Making of the Inexpensive Brake Pressure Bleeder

12mm Dissolved Oxygen Sensor Care and Use Instructions

RayPette Plus Autoclavable Pipette. User Manual

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

LogIT Dissolved Oxygen Probe

How to use Solvent Purification System A brief manual

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

Unblocking the MicroSprayer Aerosolizer Model IA-1B With the High Pressure Reverse Cleaning Adapter. Instructions for Use

ASPHALT WAQTC FOP AASHTO T 209 (12)

Operating Instructions

Standard. Abdominal Aortic Aneurysm (AAA) Repair Trainer. Part No: 60610

LIQUIP DRYBREAK COUPLER. LYNX Series MAINTENANCE INSTRUCTIONS

602 STRINGING MACHINE OWNER'S MANUAL

Flow control valves Series RFU - RFO 2/

Underwater Housing for Panasonic Lumix DMC-ZS60, DMC-TZ80

Operating Instructions

Abdominal Aortic Aneurysm (AAA) Repair Trainer User Guide

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Solvent System Walkthrough

Underwater Housing for Canon G7X Mark II

IN-PLACE DENSITY WAQTC FOP AASHTO T 209 (16)

Pipettor. User Manual

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Moving Fluids Concept and Theory

Flexfence Swaging Unit. Product Manual. Release 02/16.

The density of a substance is the same for all samples of that substance.

Transcription:

PREPARATIONS FOR PIEZOCONE CPTU TESTING (De-airing and Saturating) A proper preparation of the piezocone and other equipment is paramount prior to CPTU testing in order to have good pore pressure response. The following components of the piezocone should be de-aired and saturated entirely: - the pore pressure filter - the cavity between the pore pressure filter and the pore pressure sensor of the piezocone - the housing of the pore pressure sensor We recommend to use glycerine for saturating, since it is miscible with water. Other fluids, such as silicon oil, demineralized water or a vegetable type of oil (for example sunflower or olive oil) can be used as well, but present specific problems that require special attention. This manual is purely based on the use of glycerine as saturation fluid. The saturation procedure consists of 2 specific stages, i.e. the de-airing of the pore pressure filters (mostly done in the office the day before CPTU testing) and the saturation of the piezocone (mostly done in the field). Patience and cleanness are paramount during the whole process of de-airing and saturating. Take your time and wear clean latex gloves during the whole process in order to prevent dirt to get into the saturating fluid. 1 De-Airing the Filters About 24 hours before the actual CPTU tests will take place, the pore pressure filters are to be de-aired and saturated with glycerine. Pore pressure filters Pressure vessel Porcelain plate Vacuum pump Glycerine Soup ladle Airtight container To achieve this, the following equipment is recommended: - Pore pressure filters (sufficient quantity) - Pressure vessel with porcelain plate - High-vacuum silicon grease - Vacuum pump (manual or electrical) with pressure gauge - Glycerine (saturation fluid) - Soldering wire - Small soup ladle - Airtight container for storage and transport Gouda Geo-Equipment B.V. www.gouda-geo.com tel. +31 (0)715 318 475 page 1

For optimum results, please follow the following procedure to de-air the pore pressure filters: 1. Dry the pore pressure filters in a oven (approx. 1 hour at 65 ºC) 2. Fill the pressure vessel for ¾ with glycerine (approx. 2 liters) 3. Fold the soldering wire around the pore pressure filters to make them more heavy so they will remain submerged much easily during the whole process 4. Place the dried and weighted pore pressure filters on the porcelain plate in the glycerine in the pressure vessel 5. Put a bit of high-vacuum silicon grease on the sealing rims of both the lid and the stop-cock 6. Put the lid and stop-cock onto the vessel 7. Connect the vessel to the vacuum pump and switch it on 8. Create an underpressure of 0.4 bar (check the pressure gauge) and make sure this underpressure is maintained for a period of 24 hours 9. Open the pressure vessel and pore some of the de-aired glycerine in the airtight container 10. Take the pore pressure filters gently out of the pressure vessel using the soup ladle and put them in the airtight container. Make sure the pore pressure filters remain submerged during this operation. 11. Fill the airtight container with glycerine as much as possible and close the lid. The pore pressure filters are now ready for use. 2 Saturating the Piezocone Prior to the CPTU test in the field, the piezocone is to be prepared, the pore pressure filter put in place and the piezocone itself saturated. Soup ladle Syringe Condom Pair of pliers Funnel Saturation funnel To achieve this, the following equipment is recommended: - De-aired pore pressure filters (sufficient quantity) - Small soup ladle - Syringe - Knitting needle - Condoms - Clean (!) pair of pliers - Funnel - Special saturation funnel that fits around the piezocone Please consider the following guidelines on how to prepare the piezocone for CPTU testing: 1. Prior to the test, the cone should be checked (minimum dimensions, irregularities and damages. Read the applicable Standard for detailed information on this issue) and cleaned properly. Remove the conical tip and possibly present filter support ring(s) and put the cone top-up in a bench vice. Clean the visible cone interior with a soft cloth. Gouda Geo-Equipment B.V. www.gouda-geo.com tel. +31 (0)715 318 475 page 2

2. Mount the saturation funnel on the piezocone and fill the housing of the pore pressure sensor with de-aired glycerine from the airtight container using a syringe. Try to avoid possible air bubbles in the piezocone. Possible air bubbles can be removed by stirring the fluid gently using the knitting needle. Fill the funnel gently with about 1 liter of de-aired glycerine from the same airtight container. Let the fluid rest for some time and observe if air bubbles float towards the surface. Warning: Never remove the compensation bush or friction sleeve when you fill the piezocone with saturation fluid. This will heavily damage the electronics inside the cone. 3. Clean the filter support ring(s) (if present) and put it/them back in position 4. Put the conical tip in the saturation funnel. Fill the syringe with glycerine and make sure you remove all the air from the syringe first by squeezing out some of the glycerine. While the conical tip remains submerged, place the tip of the syringe on the hole of the conical tip and squeeze the glycerine through the conical tip and push in this way all the air out of the tip. Repeat this procedure 3 to 4 times. 5. Take one of the saturated pore pressure filters out off the container using the soup ladle. The pore pressure filter should remain fully submersed at all times. Put the pore pressure filter in the de-aired glycerine in the funnel on the piezocone. Remove the soldering wire of the pore pressure filter and position it onto the conical tip. 6. Screw the conical tip back on the piezocone - hand tight is sufficient. Now give it an extra turn with a pair of pliers to assure a tight fit. 7. Take a condom out of its packing and flip the inside outwards. Now submerge the condom and flip it back in its normal position. The condom does not contain any air anymore and is ready to be rolled over the piezocone. 8. Put a condom over the cone and roll it down the sleeve as far as possible. 9. The saturation liquid can now be poured back (gently!) from the saturation funnel into the airtight container using a funnel to avoid spilling. If necessary, the glycerine is to be filtered first. 10. Remove the funnel by sliding it downwards over the piezocone and adjust the condom if necessary. 11. Adjust the condom in such manner, that it fits nicely over the cone and that it does not cause any over- or underpressure beforehand. 12. The piezocone is now ready for CPTU testing. NOTE: It is necessary to replace the filter after each test and to follow the above procedure from point 5 on in full. Gouda Geo-Equipment B.V. www.gouda-geo.com tel. +31 (0)715 318 475 page 3

3 Saturating the Piezocone - Slideshow Pict. 1: Cone top-up in bench vice and saturation funnel in place Pict. 2: Fill the syringe with de-aired glycerine and force remaining air out Pict. 3: Fill the housing of the pore pressure sensor with de-aired glycerine Pict. 4: Fill the housing of the pore pressure sensor with de-aired glycerine layer by layer Pict. 6: Remove last remaining air bubbles and bring in the filter using the ladle Pict. 5: Fill the saturation funnel with de-aired glycerine Pict. 7: Cone and funnel filled with de-aired glycerine and saturated filter Pict. 8: Fill the syringe with glycerine from the funnel and keep the cone tip handy Gouda Geo-Equipment B.V. www.gouda-geo.com tel. +31 (0)715 318 475 page 4

Pict. 10: Make sure there are no air bubbles left in the cone tip Pict. 11: Maneuver the filter onto the cone tip. Make sure that everything remains submerged Pict. 9: Squeeze the glycerine through the hole in the cone tip whilst submerged Pict. 12: Screw the cone tip and filter onto the cone Pict. 13: Flip the inside of the condom outwards and back and slide it over the cone Pict. 14: Slide the condom over the cone as far as possible and adjust it Pict. 15: Pour the saturation fluid gently back into the airtight container Pict. 16: Remove the funnel by sliding it downwards over the cone Pict. 17: Adjust the condom such that it causes no over- or underpressure on the filter. The piezocone is now ready for CPTU Gouda Geo-Equipment B.V. www.gouda-geo.com tel. +31 (0)715 318 475 page 5