Pump Stages. By Tom Murray

Similar documents
INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

Driver Operator Pumps: Basic Pump Operations

Varying pump capacity affects the required hoseline diameter

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 24 Attack Hose Lays Revised

Apparatus Operator/Pumper

Apparatus Operator Refresher Training Program

Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

SINGLE VALVE WITH LOW-FLOW BYPASS

INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR FIRE HOSE AND NOZZLES

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition)

TurboDraft Fire Eductor

Chapter 14 Water Shuttle Operations

FIREGROUND HYDRAULICS

MANUAL FLOW CONTROL 2-1/2" - 18" QUICKSET FLOW CHART

Waterous Relief Valve

HYDRANT/WATER POINT INSPECTION AND MAINTENANCE

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU

TurboDraft. Fire Eductor Operating Instructions.

Essentials of Fire Fighting

Discharge Relief Valve Operation & Maint.

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET

Volunteer Firefighter Applicant Information Package

Des Plaines Fire Dept. Engineer Program

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION

ENGINE COMPANY OPERATIONS CHAPTER 12 February 15, 2006 WATER LOSS PROCEDURES

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

SELECTION & APPLICATION

PERFORMANCE CRITERIA AND INSTRUCTIONS

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

Head to Head Demo Comparison Sheet

Apparatus Driver/Operator Evaluation Form Rosenbauer Tanker:

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition)

Goulds 3296 EZMAG. Chemical Process Pump

Air Amplifiers & SYSTEMS

Model: 43T. Bermad Pressure Relief Valve

PUMP OPERATIONS SAN FRANCISCO FIRE DEPARTMENT

Fire Apparatus Operator: Pumper

TECHNICAL DATA. Table 1 - Specifications

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1

Choosing the Right Pump for Your Project

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM HYDRA ASSIST VALVE

KILGORE FIRE DEPARTMENT

Flow Material Length. Weight GPM LPM. Style 3095

San Ramon Valley Fire Protection District

Fire Apparatus Operator: Pumper

TECHNICAL DATA Q= C. Table 1 - Specifications

III. Identify the initial installation requirements for standpipe systems

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus.

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

second test was conducted using at 3/4inch nozzle to determine a practical maximum pressure for the pump.

FACHGESPRÄCH 3 NPSH NPSH3. Let us call it: CAVITATION A LOOK UNDER THE HOOD

Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system.

HAND-OPERATED, ZERO-THRUST AND FOOT-OPERATED

TECHNICAL DATA. than the water inlet pressure to the concentrate

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

ELKHART BRASS MANUFACTURING COMPANY

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

1 Exam Prep. Tabs and Highlights

12 Impeller Replacement

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

Model 420-HY Pressure Regulating Hydrant Valve

STAINLESS STEEL GRAND SERIES

Driver Releasal Manual

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Water Thiefs APPLIANCES APPLIANCES WATER THIEFS

All information correct as of 25 th September 2013 and subject to change without notice. 6 inch HURRICANE modular dredge equipment operations manual.

Design Change Notification

STUDENT SUPPLEMENT. Approved and Adopted by the Office of State Fire Marshal

PX4 P L A S T I C PX4 PERFORMANCE WIL T-02

Tanker Fill Tests. Evaluating Direct Fill Lines DeKalb County, Alabama. November 16, Tests DeKalb County, AL

Residential Pressure Booster Systems

Bermad Pressure Reducing. Model: 42T

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

PROCESS ROTATING EQUIPMENT (CENTRIFUGAL PUMPS )

NOTES ON WATER HAMMER. 55

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

2017 Volunteer Week - Course Descriptions

Compressors. Basic Classification and design overview

CONTINENTAL NH3 PRODUCTS PRODUCT CATALOG

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA

PX800 M E T A L PX800 PERFORMANCE WIL T-08

Centrifugal Pump Intro

KMT Waterjet Systems Inc.

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011

HOME DEFENSE LAND. Call (800) , Ext. 3528

Poudre Fire Authority Driver/Operator Manual Third Edition March 2006

Vacutrans Instructions

Basic layout 2016 IRRIGATION-MART. Check (Non- Leak) Valve. Friction Fit. Sprinkler. Figure 1 - Hanging Sprinkler & Check Valve Assembly

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Cozumel Turbodraft. Operational Considerations

FIREFIGHTING EQUIPMENT

AirCannonPlans.Com. High Powered Water Cannon

Transcription:

Pump Stages By Tom Murray As is often the case, we in the fire service tend to make things more difficult than they need to be. I believe this is the situation when discussing the pros and cons of single, twostage and three-stage pumps for fire apparatus. As stated by Robert J. Barraclough in a Firehouse Magazine article written November 1978, Do we buy the equipment that our department really needs? Or do we buy on tradition, past experience, or misunderstanding? When reviewing the pump operations handbooks from the various major fire department pump manufacturers, we may be surprised to see the variety and disparity of opinions of what is best for the fire service. Without discussing the merits of these opinions, I m going to present mine and allow you to draw your own conclusions. SINGLE-STAGE PUMPS: New single-stage pumps are far superior to single-stage pumps of the past. The basic reason for this is the major redesign of the impeller serving the single stage pump. The impellers of older single-stage pumps were basically the same design of those impellers used for two-stage pumps. The older single-stage impellers were narrow and took supply from only one side of the impeller. Today s newer single-stage impellers are designed with a wider water way and can take supply from both sides of the impeller. Below is an example of a single-stage impeller next to a two-stage impeller: View of a single-stage impeller next to a two-stage impeller

With the larger waterway, and ability to take supply from both sides, the single-stage pump is able to meet NFPA and Undwriters Libratory requirements. Below is a view of the volutes of a single-stage impeller pump casing and that of a twostage impeller-pump casing. Single-stage impeller pump casing Two-stage impeller pump casing You can see that the volutes of each are about the same size. However the width of the impellers are substantially different. With this newer design, single-stage pumps are easily capable of providing the NFPA 1901 and UL pressure and volume ratings required for fire pumps. The other benefits of a single-stage pump is that they cost less, and because they are easier to operate and have fewer moving parts they are less likely to need repair than a two-stage pump. Because single-stage pumps don t have a transfer valve as required in multi-stage pumps, training and fireground operations become much simpler an important point

should your department primarily rely on volunteers or not have pump operator specialists (engineers). It is true that single-stage pumps of 1,250-gpm rating and higher are not as efficient when supplying low volumes at high pressures. When would this happen? It would happen in situations involving high-rise buildings over 40 stories; when pumping up high, steep hills; or when supplying high-pressure, low-volume wildland-type nozzles. In these situations, single-stage pumps rated at 1,250 gpm and higher, pumping for extended periods of time, would not be your pump of choice. The reasons are that single-stage pumps become less effective at pressures above 350 psi. 350 psi is a lot of pressure. The fact of the matter is that most departments don t operate with hose with burst pressures above 300 psi, with the exception of Booster Line hose and Forestry line hose. Hose manufactures will suggest that safe operating pressures be kept 50 psi below burst pressure. For most 2½-inch hose, this would mean a maximum of 250 psi pump discharge pressure. The point is that even if you wanted to pump high pressures, your hose-burst pressure rating would prevent you from doing so safely. For those departments that frequently respond to wildland firefighting, you would want a pump-and-roll capability. A separate power-takeoff-driven pump designed for pressures above 350 psi would provide you with the capability for high pressures and save the single-stage midship pump for your other pumping requirements. An example of this pumping configuration is that of the Type-1 Engine operated by the Weed Fire Department, Siskiyou County, in Northern California. This is a small department with a full-time chief of department supported by volunteers and fire technology student sleepers.

Weed (California) Fire Protection District 1,250-GPM, single-stage pump The water flow capabilities of this single-stage, 1,250-gpm pump is excellent for this community and the firefighters who will be operating this pump. Ease of operation, means less required pump training, simpler hydraulics, and a lower exposure to downtime due to required pump maintenance. This single-stage Weststates 1,250-gpm pumper is an excellent choice for this department. A community of primarily one-story, 2-3-bedroom, single-family residences, supported by a small town commercial community of one- and two-story stores and businesses. The City of Weed does have a large active 24-hour mill operation that does present a significant fire hazard. However, considering this department's resources and normal fire exposure this single-stage pumper is still a very good choice. TWO-STAGE PUMPS: High-rise pump operations (over 40 stories) or relay pumping in steep, hilly communities such as San Francisco need a two-stage pump for the wide variety of pump pressures required. San Francisco has over 800 high-rise buildings. Its tallest building is the 55-story Bank of America World Headquarters at Pine and Kearny Street. Should the San Francisco Fire Department need to pump to the top floor of this 55-story building, the pumper would have to be able to generate a pump pressure of 500 psi. Fireground hydraulics are 5 psi head pressure times 55 floors = 275 psi, plus 25 psi friction loss at the FDC, 10 psi minimum friction loss between pumper and FDC (estimate), and a desired fire flow of 150 psi on the fire floor for multiple fire attack lines. (460-psi minimum required).

San Francisco Fire Department 1,500-GPM, two-stage pump San Francisco must be prepared to pump at high pressures. Its apparatus is very well suited for such pump demands. San Francisco is the last remaining municipal fire service agency in California that still runs with three-inch hose with three-inch couplings. All newer apparatus have three-inch piping from the pump housing to the discharge outlet. There are two three-inch piped auxiliary gated inlets piped directly into the fire pump. The two main suction inlets have a three-inch screw-type gated valve inlet that immediately widens out to a six-inch manifold directly to the fire pump. Two three-inch large-line hose beds have a combined hose load of 1,000 feet of Angus premium fire hose. Two small-line pre-connect hose beds run from the rear tailboard to the front of the hose bed holding 150 feet and 200 feet of 1¾-inch Angus High Combat II hose. The 200-foot pre-connect has a ¾-inch solid stream nozzle. The 150-footer has a Task Force 200-gpm Thunder Fog nozzle. Subject to the engine captain's choice, the engine will carry either two 100-foot, 1¾-inch hose bundles or 100-foot high-rise packs, or one of each, as the captain believes is needed in the engines response area. THREE-STAGE PUMPS: Fire Department New York serves a city with buildings as tall as 110 stories. For this reason FDNY has three-stage pumps. The FDNY incorporates a recommended-pump-pressure chart in their high-rise procedures. (Keep in mind that the FDNY considers the procedure of high-pressure pumping when pumping to floors over 50 stories and when pumping pressures higher than 250 psi as a last resort, or so I am advised.)

Safety procedures are a must. Those interested in high-pressure pump procedures over 250 psi can contact me via Fire Nuggets for a presentation I gave at FDIC West 1999. FIRE FLOORS CONTROLLING NOZZLE FOG NOZZLE 1-10 150 200 11-20 200 250 21-30 250 300 31-40 300 350 41-50 350 400 51-60 400 450 61-70 450 500 71-80 500 550 81-90 550 600 91-100 600 650 101-110 650 700 With such high pressures required, a three-stage pump becomes a necessity. Hose used for such pumping is Angus 2,000-psi burst pressure.