Certificate of Compliance

Similar documents
Certificate of Compliance

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

CERTIFICATE OF COMPLIANCE

Certificate of Compliance

Fisher FIELDVUE DVC6000 Digital Valve Controllers

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof

Certificate of Compliance

I/P Transducer Positioner Module

IECEx Certificate of Conformity

CERTIFICATE OF COMPLIANCE

Certificate of Conformity

TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

PT-400 User Manual APG

General Specifications

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

General Specifications

PT-400 User Manual APG

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

IECEx Certificate of Conformity

VG5 Supplementary instructions

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Torque Tube TB300 Digital Transmitters

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus

Field Certification Certificate of Compliance

Orifice Plate Flow Meter

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Intrinsically safe solenoid valves on/off controls - ATEX certification

General Specifications

Explosion Proof I/P Transducer

Technical Data. Dimensions

Technical Data. Dimensions

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

II 2G EEx ia IIC T6. Ignition protection class

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Inductive slot sensor

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Rosemount 2120 Full-featured Vibrating Fork Liquid Level Switch. Quick Start Guide , Rev BA August 2012

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. Dimensions

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

Dynisco SPX Industrial (2280/2281) Series

TYPE APPROVAL CERTIFICATE

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Technical Data. Dimensions

Pressure switch, Differential pressure switch and Thermostat RT-E

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

High-performance submersible pressure transmitter For level measurement Model LH-20

ER3000 Explosion Proof Manual

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

USER INSTRUCTIONS. NT3000 Series Electro-Pneumatic Transducer Module. Installation Operation Maintenance. Experience In Motion FCD VLENIM /12

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

SSL. Smart Valve Positioner.

Technical Datasheet. Pressure Transmitter: Analogue Series 387. Performance characteristics. Product applications. How can we help you?

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

TYPE APPROVAL CERTIFICATE

Smart performance with innovative and ever-strong coil drive even under harsh working environments

Tapped exhaust port. Sturdy, simple, reliable design. Easy to add on Feedback. High gain pilot valve. Simple calibration, external zero adjustment

High-performance submersible pressure transmitter For level measurement Model LH-20

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell Fully Approved

Rosemount Integral Orifice Flowmeter Series

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Technical Data. Dimensions

Electro-Pneumatic Positioner TZIDC-200, TZIDC-210, TZIDC-220

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Magnetic level switch type MR783 Instruction Manual

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

A Unified Marking System for Ex Equipment

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

Pressure control, differental pressure control and thermostat Type RT

SSR. Smart Valve Positioner.

ATM.1ST/Ex - High Precision Transmitter

Differential Pressure Transmitters

1 Technical specifications

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

Siemens AG Span (min... max.) Max. perm. test. 87 psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar)

Hoffman Purge/Pressurization Manual for Models PLCF1YZ PLCB1YZ

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Transcription:

Certificate of Compliance Certificate: 1127056 Master Contract: 154490 Issued to: Fisher Controls International LLC 205 S Center St Marshalltown, IA 50158 USA Attention: Daniel G. Moyer The products listed below are eligible to bear the CSA Mark shown Issued by: James Lim James Lim PRODUCTS CLASS 2258 02 CLASS 2258 04 - PROCESS CONTROL EQUIPMENT - For Hazardous Locations - PROCESS CONTROL EQUIPMENT - Intrinsically Safe, Entity - For Hazardous Locations CLASS 2258 02 - PROCESS CONTROL EQUIPMENT - For Hazardous Locations Class I, Div. 1, Groups B, C and D; Class II, Div. 1, Groups E, F and G; Class II, Div 2, Groups F and G; Class III, Div. 1; Class I, Div. 2, Groups A, B, C and D; Ex d IIC; Ex nc IIC, Type 4X; IP66; Single Seal Device: DVC6005, DVC6200, DVC6200S, DVC6205 (HART Communication Protocol); rated input 30Vmax, 20mA; - 52 Deg. C < Ambient < + 80 Deg. C; Temperature Code T5 at Tamb = 80 Deg. C; T6 at Tamb = 75 Deg. C, Max inlet pressure 145 psig (air or natural gas). DVC6005, DVC6200, DVC6200S, DVC6205 (HART Communication Protocol c/w HW2 Electronics); rated input 30Vmax, 20mA; - 52 Deg. C < Ambient < + 80 Deg. C; Temperature Code T5 at Tamb = 80 Deg. C; T6 at Tamb = 75 Deg. C, Max inlet pressure 145 psig (air or natural gas). Digital Valve Controllers, Types DVC6010F, DVC6020F, DVC6030F, DVC6010FS, DVC6020FS, DVC6030FS, DVC6005F, DVC6200F, DVC6200FS, DVC6205F (FIELDBUS Communication Protocol); rated input 30Vmax, 20mA; - 52 Deg. C < Ambient < + 80 Deg. C; Temperature Code T5 at Tamb = 80 Deg. C; T6 at Tamb = 75 Deg. C, Max inlet pressure 145 psig (air or natural gas). DQD 507 Rev. 2012-05-22 Page: 1

Digital Valve Controllers, Types DVC6200P, DVC6200PS, DVC6205P (PROFIBUS Communication Protocol); rated input 30Vmax, 20mA; - 52 Deg. C < Ambient < + 80 Deg. C; Temperature Code T5 at Tamb = 80 Deg. C; T6 at Tamb = 75 Deg. C, Max inlet pressure 145 psig (air or natural gas). Class I, Div. 1, Groups B, C and D; Class II, Div. 1, Groups E, F and G; Class I, Div. 2, Groups A, B, C and D; Class II, Div 2, Groups F and G; Class III, Div. 1; Ex d IIC; Ex na IIC, Type 4X; IP66: Feedback Assembly, Types DVC6015, DVC6025, DVC6035; rated input 10Vmax, 5mA; -60 Deg. C < Ambient < + 125 Deg. C; Temperature Code T4 at Tamb = 125 Deg. C, T5 at Tamb = 95 Deg. C, T6 at Tamb = 80 Deg. C Class I, Div. 1, Groups A, B, C and D; Class II, Div. 1, Groups E, F and G; Class I, Div. 2, Groups A, B, C and D; Class II, Div 2, Groups F and G; Class III, Div. 1; Ex d IIC; Ex na IIC, Type 4X; IP66: Feedback Assembly, Types DVC6215; rated input 30Vmax, 20mA; -52 Deg. C < Ambient < + 125 Deg. C; Temperature Code T4 at Tamb = 125 Deg. C, T5 at Tamb = 90 Deg. C, T6 at Tamb = 75 Deg. C CLASS 2258 04 - PROCESS CONTROL EQUIPMENT - Intrinsically Safe, Entity - For Hazardous Locations Class I, Div. 1, Groups A, B, C and D; Class II, Div. 1, Groups E, F and G; Class III, Div. 1; Ex ia IIC; Type 4X; IP66 Single Seal Device: DVC6200, DVC6200S (HART Communication Protocol); rated input 30Vmax, 20mA; intrinsically safe when connected per Installation Drawing No. GE42818. Entity parameters: (Loop Terminals) Vmax = 30V, Imax = 226mA, Pi = 1.4W, Ci = 5nF, Li = 0.55mH; - 52 Deg. C < Ambient < + 80 Deg. C; Temperature Code T5 at Tamb = 80 Deg. C; T6 at Tamb = 75 Deg. C, Max inlet pressure 145 psig (air or natural gas). Digital Valve Controllers, Types DVC6005 (HART Communication Protocol); rated input 30Vmax, 20mA; intrinsically safe when connected per Installation Drawing No. GE42818. Entity parameters: (Loop Terminals) Vmax = 30V, Imax = 226mA, Pi = 1.4W, Ci = 5nF, Li = 0.55mH; (Remote Feedback Terminals) Voc = 30V, Isc = 12mA, Po = 86mW, Ca = 66nF, La = 246mH; - 52 Deg. C < Ambient < + 80 Deg. C; Temperature Code T5 at Tamb = 80 Deg. C; T6 at Tamb = 75 Deg. C, Max inlet pressure 145 psig (air or natural gas). DVC6200, DVC6200S (HART Communication Protocol c/w HW2 Electronics); rated input 30Vmax, 20mA; intrinsically safe when connected per Installation Drawing No. GE42818. Entity parameters: (Loop Terminals) Vmax = 30V, Imax = 130mA, Pi = 1.0W, Ci = 15nF, Li = 0.55mH; (Output Terminals) Vmax = 28V, Imax = DQD 507 Rev. 2012-05-22 Page: 2

100mA, Pi = 1.0W, Ci = 15nF, Li = 0.50mH; - 52 Deg. C < Ambient < + 80 Deg. C; Temperature Code T5 at Tamb = 80 Deg. C; T6 at Tamb = 74 Deg. C (without I/O package) and T5 at Tamb = 80 Deg. C; T6 at Tamb = 61 Deg. C (with I/O package), Max inlet pressure 145 psig (air or natural gas). Digital Valve Controllers, Types DVC6005, DVC6205 (HART Communication Protocol c/w HW2 Electronics); rated input 30Vmax, 20mA; intrinsically safe when connected per Installation Drawing No. GE42818. Entity parameters: (Loop Terminals) Vmax = 30V, Imax = 130mA, Pi = 1.0W, Ci = 15nF, Li = 0.55mH; (Output Terminals) Vmax = 28V, Imax = 100mA, Pi = 1.0W, Ci = 15nF, Li = 0.5mH; (Remote Feedback Terminals) Voc = 30V, Isc = 21.2mA, Po = 160mW, Ca = 55nF, La = 78mH;- 52 Deg. C < Ambient < + 80 Deg. C; Temperature Code T5 at Tamb = 80 Deg. C; T6 at Tamb = 74 Deg. C (without I/O package) and T5 at Tamb = 80 Deg. C; T6 at Tamb = 61 Deg. C (with I/O package), Max inlet pressure 145 psig (air or natural gas). Digital Valve Controllers, Types DVC6010F, DVC6020F, DVC6030F, DVC6010FS, DVC6020FS, DVC6030FS, DVC6200F, DVC6200FS (FIELDBUS Communication Protocol), DVC6200P, DVC6200PS (PROFIBUS Communication Protocol); rated input 30Vmax, 20mA; intrinsically safe when connected per Installation Drawing No. GE42818. Entity parameters, Fieldbus version: (Loop Terminals) Vmax = 24V, Imax = 380mA, Pi = 1.4W, Ci = 5nF, Li = 0mH; FISCO version: (Loop Terminals) Vmax = 17.5V, Imax = 380mA, Pi = 5.32W, Ci = 5nF, Li = 0mH; Temperature Code T4 at Tamb = 80 Deg. C, T5 at Tamb = 77 Deg. C, T6 at Tamb = 62 Deg. C, Max inlet pressure 145 psig (air or natural gas). Digital Valve Controllers, Types DVC6005F, DVC6205F (FIELDBUS Communication Protocol), DVC6205P (PROFIBUS Communication Protocol); rated input 30Vmax, 20mA; intrinsically safe when connected per Installation Drawing No. GE42818. Entity parameters, Fieldbus version: (Loop Terminals) Vmax = 24V, Imax = 380mA, Pi = 1.4W, Ci = 5nF, Li = 0mH; (Remote Feedback Terminals) Voc = 24V, Isc = 17.5mA, Po = 105mW, Ca = 121nF, La = 100mH ; FISCO version: (Loop Terminals) Vmax = 17.5V, Imax = 380mA, Pi = 5.32W, Ci = 5nF, Li = 0mH; (Remote Feedback Terminals) Voc = 17.5V, Isc = 17.5mA, Po = 105mW, Ca = 121nF, La = 100mH; Temperature Code T4 at Tamb = 80 Deg. C, T5 at Tamb = 77 Deg. C, T6 at Tamb = 62 Deg. C, Max inlet pressure 145 psig (air or natural gas). Class I, Div. 1, Groups A, B, C and D; Class II, Div. 1, Groups E, F and G; Class III, Div. 1; Ex ia IIC; Type 4X; IP66: Feedback Assembly, Types DVC6015, DVC6025, DVC6035; rated input 10Vmax, 5mA; intrinsically safe when connected per Installation Drawing No. GE42818. Entity parameters, Vmax = 30V, Imax = 100mA, Pi = 160mW, Ci = 0nF, Li = 0mH; -60 Deg. C < Ambient < + 125 Deg. C; Temperature Code T4 at Tamb = 125 Deg. C, T5 at Tamb = 95 Deg. C, T6 at Tamb = 80 Deg. C DQD 507 Rev. 2012-05-22 Page: 3

Feedback Assembly, Types DVC6215; rated input 30Vmax, 20mA; intrinsically safe when connected per Installation Drawing No. GE42818. Entity parameters, Vmax = 30V, Imax = 226mA, Pi = 1.4W, Ci = 50nF, Li = 0mH; -52 Deg. C < Ambient < + 125 Deg. C; Temperature Code T4 at Tamb = 125 Deg. C, T5 at Tamb = 90 Deg. C, T6 at Tamb = 75 Deg. C APPLICABLE REQUIREMENTS C22.2 No. 0-10 - General Requirements - Canadian Electrical Code, Part II C22.2 No. 25-1966 - Enclosures for Use in Class II, Groups E, F and G Hazardous Locations C22.2 No. 30-M1986 - Explosion-Proof Enclosures for Use in Class I Hazardous Locations C22.2 No. 94-M91 - Special Purpose Enclosures C22.2 No. 142-M1987 - Process Control Equipment C22.2 No. 157-92 - Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations C22.2 No. 213-M1987 - Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations C22.2 No. 60529:05 - Degrees of protection provided by enclosures (IP Code) ISA 12.27.01:2011 - Requirements for Process Sealing Between Electrical Systems and Flammable or Combustible Process Fluids CAN/CSA- C22.2 No. 60079-0:11 - Explosive atmospheres - part 0: Equipment - General requirements CAN/CSA- C22.2 No. 60079-1:11 - Explosive atmospheres - part 1: Equipment protection by flameproof enclosures d CAN/CSA- C22.2 No. 60079-11:11 - Explosive atmospheres - part 11: Equipment protection by intrinsic safety i CAN/CSA- C22.2 No. 60079-15:12 - Electrical apparatus for explosive gas atmospheres - Part 15: Construction, test and marking of type of protection n electrical apparatus. DQD 507 Rev. 2012-05-22 Page: 4

Supplement to Certificate of Compliance Certificate: 1127056 Master Contract: 154490 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description 2658569 Oct 22, 2013 Update to report 1127056 to add CSA Zone approvals to all models based upon data from IECEx Certificate CSA04.0004X, and update of descriptive documents. 2577935 Dec 7, 2012 Update to report 1127056 to include revised IS t-codes for the HW2 Electronics 2450272 Jul 18, 2012 Update report 1127056 to include hardware revision 2 (HW2) electronics changes to the Model 6000 Series. 2409342 May 29, 2012 (EDM37-FEB) Evaluation of new models,dvc6200s, DVC6200FS, DVC6200PS, DVC6205, DVC6205F, DVC6205P and DVC6215 for FM standards. Update and submission of revised FM report 3010030 under CSA/ FM agreement. 2409344 Dec 16, 2011 update to report 1127056 to include new SST models DVC6200S, DVC6200FS, DVC6200PS and DVC6205, DVC6205F, DVC6205P, DVC6215. 2331104 Jul 26, 2010 Update of Report 1127056 to add new model DVC6200P. 2276950 Feb 24, 2010 Update to include new versions (Models DVC6200 and DVC6200F) with new "non-contact" Sensor. 2212661 Oct 30, 2009 Update Report 1127056 to include alternate slotted pin flame arrestor assembly and Report typo corrections. 2147023 Mar 30, 2009 Update to cover revisions to the main electronics assembly and the terminal box electronics for the fieldbus versions. 2062813 Oct 21, 2008 update to report 1127053 to include design change to DVC6005x remote mount unit 1921176 Mar 5, 2008 Update to report 1127053 to evaluate new terminal box design, evaluation to LTR-001 and to ISA 12.27.01. 1948836 Sep 25, 2007 Update to include revised drawings. 1794269 May 30, 2006 Update to CSA Report 1127056 to include revised drawings. 1686265 Aug 23, 2005 Update to CSA Report to allow Natural Gas as a process medium (LTR HazLoc-001-2003) exproof, IS, Div 2. 1633509 Mar 22, 2005 Update of Report 1127056 to Cover Revised Circuitry and Drawings 1507981 Feb 11, 2004 Update of Report 1127056 to Cover Addition of DVC6000f & XP Version of DVC60x5 1448402 Jul 2, 2003 Addition of Models DVC6005, DVC6015, DVC6025 and DVC6035 1708604 Jan 1, 0001 Update to CSA Report to correct inconsistencies with Lab report. DQD 507 Rev. 2012-05-22 Page: 1

History 1343707 July 31, 2002 Update to cover revised circuitry, alternative enclosure material (SST) and revised drawings. 1214439 June 28, 2001 Update to cover evaluation of modified flame arrestor assemblies 1127056 Dec. 4, 2000 Original Certification. DQD 507 Rev. 2012-05-22 Page: 2