Recommendations for Marking Power Facilities

Similar documents
Recommendations for Marking Communication Facilities

Recommendations for Marking Gas Facilities Using 3M EMS Electronic Markers

8. Tracking, Marking and Locating. 8. Tracking, Marking & Locating your FTTx Network

3M Electrial Markets Division EMS. Electronic Marker System

Locating and Marking. Locators Markers Locator & Marker Accessories Locating and Marking

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS

About us. Try us to trace your network!

This document to be used with Hurley traditional Davits

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Golf Performance Monitors. PureContact Operating Guide. Version of 9

8. Tracking, Marking and Locating. 8. Tracking, Marking & Locating your FTTx Network

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

DT400/436 Tee Connector Installation Instructions

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Features Forward facing doors which allow expansions to the side of existing cabinets.*

COOPER POWER SERIES. 200 A 15, 25, and 35 kv class portable feedthru installation instructions. Loadbreak Apparatus Connectors MN650037EN

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)

Electric and Natural Gas Safety Trainer s Guide

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

COOPER POWER SERIES. 200 A 15/25 kv class deadbreak straight connector installation instructions. Deadbreak Apparatus Connectors MN650043EN

Work Standard CABLE PULLING OPERATIONS

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS Grips

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Electrical Tapes Selection Guide. 3Innovation

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

Norrsken Family Booklet

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

COOPER POWER SERIES. EL Bay-O-Net Current-Limiting Fuse Installation Instructions. Fusing Equipment MN132023EN

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

GAS PIPELINE SAFETY GUIDE.

AND OPERATION INSTRUCTIONS

Installation and Operation Manual

Getting to know your Sureshotgps micro V3

COOPER POWER SERIES. 200 A 15, 25, and 35 KV class insulated standoff bushing installation instructions. Loadbreak Apparatus Connectors MN650039EN

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

6 digital caliper with case

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

OPERATOR'S MANUAL GRASS CATCHER GC-4D

APPENDIX D HYDRO-VAC

OPERATOR S MANUAL. Fabric Grass Catcher PART NO PRINTED 1/2011 PRINTED IN USA

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

TR5000 THE TOUGHEST TRAINING SYSTEM ON THE PLANET. MODEL NO. STRIKER TRAINER 2L Escalade Sports

Made in U.S.A. Narrow-U Bike Rack Heavy Duty Submittal Sheet. Materials: Finishes: Mount Options: Setbacks:

COOPER POWER SERIES. 200 A 15/25 kv class elbow installation instructions. Deadbreak Apparatus Connectors MN650042EN

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

ATEX ATEX

Proper Operation of Heath Consultants Incorporated Plunger Bar

Moai Bike Rack Heavy Duty Submittal Sheet. Materials: 2.0 Schedule 40 Pipe (2.375 OD) Finishes: Capacity: Mount Options: Setbacks: 2 Bikes

Owner s Manual & Safety Instructions

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

A N C H O R T A B S N O R T H W E S T ANCHOR TAB VF. Patented. User Instructions

OPERATOR'S MANUAL. MODEL GC-F4 Fabric Grass Catcher P/N 9055 GRASS CATCHER GC-F4. PART Rev.2 SC301G

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide

Medical Gas Solutions

Rescue Ladder Model: KT ft (5.48m)

2000 lb manual winch

Cocoa Patio Pond with Lit Spillway

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248

! Warning, refer to accompanying documents.

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

Rescue Ladder Model: CTB LDR-RSC 18ft (5.48m)

Traditional Basketball Set. Assembly & Installation Instructions

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

USER INSTRUCTION MANUAL CONCRETE BOLT ANCHORAGE CONNECTOR

OPERATION AND INSTRUCTION MANUAL ROLLER SLING Model: IN106.3FT & IN106.2FT

COOPER POWER SERIES. 600 A 15, 25 and 35 kv class bushing adapter installation instructions. Deadbreak Apparatus Connectors MN650058EN

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

RADROVER REAR RACK INSTALLATION MANUAL

max 80 cm / 2 6 Trittfrequenzmesser Capteur de Cadence Trapfrequentie Sensor Sensor de Cadencia Sensore di Cadenza Sensor de Cadência Kadencesensor

SPS-5. Rate Computing Scale. Operation Manual

COMPACT METAL bender 99826

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual

IMPACT RING BIT SYSTEM Care & Maintenance Instructions

TV-114 TV-114-A Wind Speed Sensor User s Manual

602 STRINGING MACHINE OWNER'S MANUAL

CSA Sample Draw Aspirator Adapter Operator s Manual

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

COOPER POWER. SERIES VariSTAR type composite light-duty under-oil (CLU) MOV arrester installation instructions. Surge Arresters MN235023EN

HAWK ALPOLIC 350 BACK PLATES

Owner s Manual Humiport 10/20

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

V O L L E Y B A L L S E T

Advanced Test Equipment Rentals ATEC (2832)

SUUNTO COMBOS AND MECHANICAL INSTRUMENTS

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

PRODUCT CATALOGUE WHATEVER YOU RIDE WHATEVER YOU DRIVE...

OPERATION AND INSTRUCTION MANUAL

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

Bimini Top, Bimini Top Plus for Jeep Wrangler Vehicles Items # , # and #

Deep Submersible Level Transducer Series 300DS

Congratulations on your purchase of a JC Series Performer trike! The Performer JC Series is designed for everything from touring to commuting and

Transcription:

Recommendations for Marking Power Facilities with the Use of 3M EMS Electronic Markers 1.0 Overview Revised June 21, 2005 Page 1of 12

The 3М TM electronic marker system is intended to make the job of precisely locating underground facilities easier and faster. The basic component of the system is a durable electronic marker buried above key underground elements in the process of their construction or maintenance. A stand-alone 3M Dynatel TM marker locator model 1420, an integrated 3M Dynatel cable/marker locator 2200M-ID series or a 3M TM Dynatel TM cable locator 2200 series combined with a 3M TM Dynatel TM EMS Accessory 2205/2206 provides fast and accurate location of a marker many years after its placement Depending on the resonant frequency and the color, electronic markers are used to mark a wide range of underground facilities such as power supply lines, cable television networks, telecommunication lines, water supply pipelines, wastewater pipelines, oil and gas pipelines, and so on. The solid red marker that is used for general power applications. These are tuned to 169.8 khz and are available in 4 different form factors for varying applications. Power markers consist of a sealed shell containing a passive antenna a low-frequency resonance circuit tuned to the 169.8 khz frequency. The locator sends a signal to the passive marker that energizes it, this signal is reflected back to the locator. Electronic markers are immune to congestion and extremely reliable. Electronic markers are typically installed during construction when the facility is visible to the eye, making it one of the most trusted methods for positive identification of buried facilities. 2.0 General Recommendations for Electronic Marker placement Revised June 21, 2005 Page 2of 12

2.1 Recommended placement All Items of Plant that are assigned unique reference numbers on facility maps and records. Handholes Buried splices of all types Buried transformers Repair points Buried service drops - Service stubs Slack loops Depth changes Laterals Bends - Changes of direction, arcs Conduit stubs Encasement ends - Conduit ends of horizontally directional drilled (HDD) facilities Path of deep facilities installed using trenchless (HDD) construction technology Manhole covers Water crossings Major road crossings Rail crossings Utility crossings locations where the cable crosses over or under other utilities. Contractors shall certify in writing that Electronic Markers are in place, prior to paving over any of the above locations. Electronic Markers that are found to be missing shall be installed at the Contractors expense. Using the GPS interface on the 3M Dynatel Locator model 1420 and 2200M-ID series will also provide positive verification of marker placement during construction and direct data import capability to leading industry standard GIS systems for electronic map updating. Revised June 21, 2005 Page 3of 12

3.0 Recommended Marker Spacing and Depth 3.1 Recommended Depth for Ball Markers Maximum distance from ground surface to marker is as follows: 3M TM Ball Marker model 1422-XR/ID o 4ft. (1.2 m) read range using CE approved (export) versions of 3M marker locators o 5ft (1.5m) read range using US version of 3M marker locators 3M TM Ball Marker model 1402-XR o Maximum installation depth 5ft. (1.5m) detection range To increase detection area on surface, it is recommended to place the marker at half if it s rated depth. This will produce a detection area of approximately 6ft. (2 meters) in diameter. If fill to finish grade is anticipated, place marker at a 2ft. (0.5m) depth, this may vary depending on the amount of fill required. If a cut to finish grade is anticipated, place marker at its maximum rated distance of 4ft. (1.2m) for CE models and 5ft. (1.5m) for US models. If it is anticipated that there will be a need to reprogram the ID marker after it has been buried, place marker at a maximum depth of 1ft. (0.3m). 5ft. (1.5 meter) Maximum - US Versions 1.2 meter (4 Ft) Maximum - CE Versions 3M TM Ball Marker model 1422-XR/ID 4in. (10 cm) Minimum Power Line Bedding 3.2 Spacing to Utility Place ball marker at a distance of at least 4in. (10cm) from the facility. Revised June 21, 2005 Page 4of 12

3.3 Spacing Between Markers Minimum distance between markers should be at least 6ft. (2 meters) for clear identification. In straight sections for path marking applications, it is recommended to place markers adjacent to existing above ground landmarks such as telephone or power poles to simplify future locating. Markers should be placed where there is direct line of sight to the next marker. Recommended 400ft. (100m) maximum distance between markers with a preferred distance of 200ft. (50m) between markers. In bends or lateral deflections, it is recommended to place one marker for every 1ft. (0.3m) deflection (arc) to accurately indicate cable position. Minimum spacing between markers should not be less than 6ft (2m). 4.0 Standard Tie Down Procedure 1. Before placing the ball marker over the key point, decide if a tie down procedure is necessary to keep it in place. If so, secure the marker by inserting a cable tie through one or both tie-down tabs and to the key point. 2. If the key point is metallic, we recommend that the ball marker be separated from it with a minimum of 4in. (12cm) of clean fill dirt. 3. Hand fill at least 6in. (15cm) of soil over the marker. 4. Backfill the hole. Revised June 21, 2005 Page 5of 12

4.1 Alternate Tie Down Procedure For deeper facilities Tie to steel rebar 5ft. (1.5m) maximum - US Models 1.2m (4ft.) Maximum - CE Models 3M TM Ball Marker model 1422XR/ID Attach using tywrap or tape Rebar Power Line Bedding 10in. (25cm.) Nominal Revised June 21, 2005 Page 6of 12

5.0 Additional Placement Recommendations for 3M TM Ball Marker 1422-XR/ID Additional applications are possible with the XR/ID series of Ball Markers due to their ability to store and convey specific facility information. Known applications for ID ball markers in power applications are shown below. Ball Markers mark the following points All Items of Plant that are assigned unique reference numbers on facility maps and records. Handholes Splice boxes Buried splices of all types Buried transformers Repair points Buried service drops - Service stubs Depth changes Laterals Tee s Bends - Changes of direction Depth changes - Lateral Deflection Conduit stubs Encasement ends - Conduit ends of horizontally directional drilled (HDD) facilities Path of deep facilities installed using trenchless (HDD) construction technology Manhole covers Manhole corners Water crossings Major road crossings Rail crossings Utility crossings locations where the cable crosses over or under other utilities. Contractors shall certify in writing that electronic markers are in place, prior to paving over any of the above locations. electronic markers that are found to be missing shall be installed at the contractors expense. sing the GPS interface on the 3M TM Dynatel TM locator models 1420 and 2200M-ID can simplify mapping and provide additional guidance to field personnel for positive verification of marker placement. Facility information that may be of value to program into the ID Ball Marker Facility owner Description of facility point (see left column) Item of plant identification number (IPID) Conductor size o # KCMIL o # MCM o # AWG Type of insulation and jacket o XLP Cross linked polyethelyne o EPR - Rubber o Paper Lead Type of splice o Y splice o Straight splice o Transition splice o 1 way or 3 way splice o Paper to Poly splice (transition splice) Voltage Depth (to facility, or from marker to facilty) Address for service drops Direction Distance or Length Date of installation or repair Revised June 21, 2005 Page 7of 12

6.0 Types of 3М EMS Electronic Markers for power applications 3M offers a complete line of electronic markers that provide solutions supporting a variety of power applications. 6.1 3M Ball Marker model 1402-XR The patented self leveling design of 3M ball marker model 1402-XR aligns the marker coil inside the ball in a horizontal position regardless of how they are placed in the ground. The marker shell is made from a high-strength plastic, which protects the device from mechanical and weather damage. The marker contains an antenna molded inside a water-resistant plastic disc, which is free-floating on the surface of a nonfreezing liquid. 1402-XR ball markers are used in to mark points of special interest that may need to be accessed in the future. In power applications where there is a need to mark non-metallic empty conduit, the 1402-XR ball marker can be used for path marking. Shell diameter 4in. (100mm) Maximum installation depth 5ft. (1.5m) detection range Minimum distance from the facility 4in.(10cm) from the ball center 6.2 3M Ball Marker model 1422-XR/ID This marker is similar to the 1402-XR ball marker in size and form. Additionally, the 1422-XR/ID ball marker contains an RFID microchip, which allows introduction and storage of facility data. Each marker comes pre-programmed with a unique 10 digit identification number. This pre-programmed number is also attached to the marker on a removable bar-coded tag, which can be peeled off before installation and attached to facility maps. Please reference section 5.0 of this document for a comprehensive listing of known applications for this marker in Power applications. In general terms, 1422- XR/iD ball markers are ideal for marking underground facilities in urban areas with a high density of underground networks, in rural areas where there are few physical landmarks that can be referenced in maps, and for marking facilities that can not be located or are difficult to accurately locate using traditional electromagnetic cable locating techniques. Additionally, 1422-XR/ID ball markers are ideal for marking high value facilities or lifeline facilities where service outages would have significant impact and cost or hardship. Shell diameter 4in. (100mm) Maximum installation depth: o 1.2 m (4ft.) read range using CE approved version of 3M marker locator o 5ft (1.5m) read range using US version of 3M marker locator Minimum distance from the facility 4in. (10 cm) from the ball center 6.21 Spacing of ball markers to buried facility 4 inches (10cm.) Revised June 21, 2005 Page 8of 12

6.3 3M Disk Marker model 1412-XR Model 1412-XR disk markers are used in handhole applications where they are attached mechanically to the top cover of hand hole boxes. 1412-XR disk markers are identical in performance to the 1402-XR ball marker. 1412-XR disk markers are not intended for direct bury applications or applications where they would be attached to solid metal manhole covers. Shell diameter 4in. (100mm) Marker height 0.7in (1.8cm) Maximum installation depth 5ft. (1.5m) detection range 6.4 3M Near Surface Marker model 1433 Recommended for urban applications, near-surface markers allow for convenient marking facilities of under asphalt or concrete or for marking facilities after construction has completed. The marker is installed vertically at a small depth in a hole drilled or gouged in soil or in street pavement. Near surface markers are also ideal for path of facilities installed using trenchless (HDD) technology. In recent years, near surface markers have become increasingly popular for marking existing or legacy facilities due to their ease of installation. Case diameter 0.8in (20mm), Case length - 3in. (76mm) Maximum installation depth 2ft. (0.6m) Minimum vertical distance from facility 2in. (5cm) Minimum horizontal distance from facility 1in. (2.5cm) 6.41 Spacing of near surface marker to buried facility Near - Surface Near - Surface 1433 Power 1433 Power 2in (5cm) 1in. (2.5cm) Revised June 21, 2005 Page 9of 12

6.5 3M Mid Range Marker model 1256 Model 1256 mid range markers are used in areas with low-density underground facilities as point markers for items of special interest such as splices, repair points, slack loops, service stubs and as guides for marking linear segments of the paths of long cables that are deeper than be accommodated with the 3M 1400 series ball markers. The 1256 mid range marker is often used in larger point excavations but not typically used in narrow trench applications due to its larger diameter. Case diameter 8.4in. (210mm) Case height 1.2in. (30 mm) Maximum installation depth - up to 6ft. (1.8m) Minimum distance from the facility to marker - 4in. (10cm) 6.51 Spacing of mid range marker to buried facility 4 inches (10cm) 6.6 3M Full Range Marker model 1251 The full range marker is designed for marking deep underground facilities. Its large diameter is also valued by facility owners as a dig shield that can protect the facility from damage from being cut or damaged by a shovel during excavation. When placed above the facility, the full range marker serves as a dig shield or cover, which warns of encroachment to the underground facility. Case diameter 15in.(380mm) Case thickness 0.7in.(17mm) Maximum placement depth up to 8ft. (2.4m) Minimum distance from the facility marked 6in.(15cm) 6.61 Spacing of full range marker to buried facility Revised June 21, 2005 Page 10of 12

7.0 3M Dynatel Electronic Marker Locators 3M Dynatel Marker Locators are recommended for locating 3M Electronic Marker System markers. 3M offers stand-alone EMS locators Models 1420 (US) and 1420E (CE approved for export). Additionally 3M offers integrated cable locators with EMS locating capabilities, the 2200M-ID series. The 3M Dynatel 2200M-ID series locators provide a single integrated platform for what has previously been two separate test sets. This can reduce the initial capital expenditure, the number of pieces of equipment that need to be maintained, space requirements in the vehicle and number of test sets that have to be carried by a technician into the field to perform a locate. 3M has recently introduced an interface for these units to communicate with selected GPS receivers which can improve efficiencies in documenting as-built facilities and reduce the need for inspection. 3M Dynatel offers the following electronic marker and multi-purpose locators. Model 1420/1420E Model 2250M/2250M-ID Model 2273M/2273M-ID With GPS interface Additional information about 3M Dynatel cable and electronic marker locating products for power applications is available at http://www.3m.com/dynatel or contact your local 3M sales professional. Revised June 21, 2005 Page 11of 12

Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Limited Product Warranty All 3M CMD products, test and measurement instruments (except accessories), manufacture dated test leads, and rechargeable batteries will conform to 3M s published specifications and will be free from defects in material and manufacture for a period of twelve (12) months from the date of purchase. Dry cell batteries included in any of 3M s products are warranted only to the extent the battery manufacturer determines such batteries are covered by its warranty. Accessories for test and measurement instruments are warranted for ninety (90) days after purchase. 3M s obligations and liability under this warranty are limited to repairing, replacing or refund of the purchase price, at 3M s option, any of 3M s products which, after normal and proper usage, are determined by 3M to be defective. This warranty does not extend to any of 3M s products which have been subjected to misuse, neglect, accident or improper applications, nor shall it extend to products which have been repaired or substantially altered outside 3M s manufacturing or repair facility, nor to any associated instruments, equipment or apparatus. Before utilizing any of 3M s products, BUYER should determine the suitability of the product for BUYER'S intended use. 3M MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. In no case, shall 3M be liable for any special, incidental, or consequential damages based upon breach of warranty, breach of contract, negligence, strict liability or any other legal theory. This limitation does not apply to claims for personal injury. Special Condition: Shipments into authorized distributor locations will have an additional ninety (90) day warranty period. Conditional Lifetime Warranty In addition to the Limited Product warranty stated above, 3M provides the following Conditional Lifetime Warranty for its Electronic Marker Products: When installed in accordance with 3M s installation instructions, 3M warrants Electronic Markers for the lifetime of the product, to be free from defects in material and manufacture, provided the Electronic Markers are located with 3M Dynatel Test and Measurement Instruments or other brand locators as may be designated by 3M in writing. This warranty does not extend to Electronic Markers that have been subjected to misuse or improper applications or that have been repaired or altered by others. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If the Marker is found to be defective within the product s normal lifetime, your exclusive remedy shall be, at 3M s option, to repair or replace the Marker or refund the purchase price. Revised June 21, 2005 Page 12of 12