ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Similar documents
DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

Operating and Maintenance Manual. Flowmeter

U S E R M A N U A L CAUTION. Models: 19MFA Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

AND OPERATION INSTRUCTIONS

U S E R M A N U A L. (CGA 870 Connection)

453 Series Steam Heated Vaporizing Regulator

UltraMaxO OXYGEN ANALYZER OPERATING MANUAL & INSTRUCTIONS FOR USE R221P11. R221M11 Rev. C

UltraMaxO OXYGEN ANALYZER OPERATING MANUAL & INSTRUCTIONS FOR USE R221P11. R221M11 Rev. K

- GAS REGULATOR - COMPACT STYLE

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

Pressure Regulator. Instructions for Use

Oxygen Dialflow Meter. Instructions for Use

USER MANUAL. AIR-OXYGEN BLENDER (DISS and NIST Connections) Model No. PM5200 Series PM5300 Series (shown) SAVE THESE INSTRUCTIONS

RK-IR Sample Draw Aspirator Adapter Operator s Manual

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

HomeFill II Oxygen Conserving Cylinder

CSA Sample Draw Aspirator Adapter Operator s Manual

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Dialflow Regulator. Instructions for Use

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

TactAir PCP Fill Kit/Adapter. Operation Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

Micro Dial-Flowmeter. Instructions for Use

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

USER MANUAL SAVE THESE INSTRUCTIONS. Manuals available on our Website;

Model ASSEMBLY and OPERATING INSTRUCTIONS

AIR INLINE METAL SHEAR

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Pressure Regulators. Instructions for Use

Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E

Portable Compressed CO 2 Regulator

Oxygen Dialflow Meter. Instructions for Use

PORTER INSTRUMENT COMPANY, INC.

USER MANUAL Series (CGA 870 Connections) SAVE THESE INSTRUCTIONS

Yoke Block Instruction Manual

Operating Manual. Check and Go Disposable Medical Depot, Inc Port Washington N.Y

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

Rev. B. Operating Instructions

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

USER MANUAL Series (Threaded Connections) SAVE THESE INSTRUCTIONS

453 Series Steam Heated Vaporizing Regulator

Equinox II NITROUS OXIDE / OXYGEN ADMINISTRATION EQUIPMENT 01EQ7000E

623 Series Dome Load Regulators

IMPACT WRENCH ASSEMBLY AND OPERATING INSTRUCTIONS

1/2 Twin Hammer Composite. Air Impact Wrench ASSEMBLY AND OPERATING INSTRUCTIONS

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Yoke Block Instruction Manual

INSTRUCTION MANUAL GAS TRAK

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

PRODUCT INFORMATION AND INSTRUCTIONS OM-810

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

INSTRUCTIONS PARTS LIST

MACS Mask CPAP System

Certified ISO 9000 INSTALLATION AND OPERATION INSTRUCTIONS. Before Installing or Operating, Read and Comply with These Instructions

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

PC1131 Electric Air Compressor

Offset head dual chuck

MODEL CALIBRATION GAS DELIVERY SYSTEM

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

User Operation Manual and Safety Instructions

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Invacare M6, M9, D Cylinder with Continuous Flow Regulator

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

User Instruction Manual

Pressure Relief Valve Instruction Manual

Vessel Installation and Operating Manual

Rejuvenation Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

U S E R M A N U A L. HELIUM-Oxygen Blender. (DISS and NIST Connections) Model No. PM5400 Series (shown) PM5500 Series SAVE THESE INSTRUCTIONS

Helium-Oxygen Blender

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Domiciliary Oxygen Switch. Instructions for Use

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Cocoa Patio Pond with Lit Spillway

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Owner s Manual & Safety Instructions

Pressure Regulators. Operating Instructions. Instrumentation

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Installation and Operating Manual

4-in-1 Professional Inflator Kit

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

G7S Hand Pump Owner s Manual

U S E R M A N U A L PM2200 SERIES SAVE THESE INSTRUCTIONS

3 COMPOSITE AIR CUT-OFF TOOL

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

EasyLife INSTRUCTIONS FOR USE. Respironics Inc Murry Ridge Lane Murrysville, PA USA JDH 3/25/10

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Transcription:

ACRYLIC FLOW METERS 0-30, 0-70 & 0-120 LPM ASSEMBLY INSTRUCTIONS & INSTRUCTIONS FOR USE R219P86 (0-120LPM) R219P87 (0-70LPM) R219P88 (0-30 LPM) R138P11 Rev. D

TABLE OF CONTENTS: 1.0 PRODUCT OVERVIEW...1 1.1 Description... 1 1.2 Indications For Use... 1 1.3 Warnings... 1 1.4 Cautions... 1-2 2.0 PRODUCT SPECIFICATIONS... 3 2.1 Flow Ranges, Graduations & Accuracy... 3 2.2 Transport/Storage Requirements... 3 3.0 OPERATING INSTRUCTIONS... 4 3.1 General Operation... 4 4.0 TROUBLESHOOTING... 5 4.1 Troubleshooting Table:... 5 5.0 RECOMMENDED MAINTENANCE... 5 5.1 Cleaning Instructions... 5 6.0 WARRANTY... 6 7.0 SYMBOL GUIDE... 7 866.4.Maxtec www.maxtec.com III

IV 866.4.Maxtec www.maxtec.com

1.0 PRODUCT OVERVIEW: 1.1 Description: The flow meter is intended for use by physicians, respiratory therapists and other authorized hospital personnal to administer selected doses of medical gases to a patient. 1.2 Indications for use: This manual instructs a professional to install and operate the flow meter. This is provided for your safety and to prevent damage to the flow meter. If you do not understand this manual, DO NOT USE the flow meter and contact your provider. 1.3 Warnings: Use flow meters only for their Intended Use as described in this manual. ALWAYS confirm prescribed flow before administering to patient and monitor flow on a frequent basis. Flow meters may contain magnetic, ferrous material that may affect the results of an MRI. Read this User Manual before installing or operating the flow meter. To Reduce the Risk of Fire or Explosion: ALWAYS follow ANSI and CGA standards for Medical Gas Products and flow meters and Oxygen Handling. DO NOT use or store oils, greases, organic lubricants or any combustible materials on or near this Flow meter. DO NOT use near any type of flame or flammable/explosive substances, vapors or atmosphere. DO NOT connect to source pressure greater than 100 psi. DO NOT smoke in an area where oxygen is being administered. 1.4 Cautions:! Use caution to avoid cross-threading fittings during installation. 866.4.Maxtec www.maxtec.com 1

Always use a backing wrench when installing or removing connectors. Flow meters must be operated with the Flow Tube in a vertical, upright position. Only personnel instructed and trained in its use should operate this flow meter. Ensure all connections are tight and leak free. Only use oxygen-safe leak detector. Only trained medical professionals should operate the flow meter. DO NOT drop the flow meter. DO NOT autoclave. DO NOT gas sterilize with EtO (Ethylene Oxide). DO NOT clean with aromatic hydrocarbons. DO NOT immerse flow meter in any kind of liquid. This will void the warranty. DO NOT USE if damaged. Inspect the flow meter for visual damage before use. DO NOT over-tighten knob when turning off. This will cause damage to the flow meter. DO NOT over-tighten any threaded connectors; body may crack and cause leaks. Pressures other than those indicated on the flow tube or flow meter body may affect the accuracy of the indicated flow. Gas Temperatures other than 70 F (21 C) may affect the accuracy of the indicated flow. Attaching accessories to the outlet (which may increase resistance to outlet flow) may change indicated flow but will not affect the accuracy of the flow. ONLY use appropriate gas specific indexed fittings to connect flow meter to gas source. Use Oxygen connections for oxygen flow meters; use air connections for air flow meters. 2 866.4.Maxtec www.maxtec.com

2.0 SPECIFICATIONS 2.1 Flow Range Accuracy Chart FLOW RANGE GRADUATIONS ACCURACY 0-30 LPM 1 (0-30) LPM 2-4: ±.50 l/min, 5-30: ± 10% of indicated value 0-70 LPM 5 (0-70) LPM ± 10% of indicated value 0-120 LPM 10 (0-120) LPM ± 10% of indicated value For the most current manual revision please visit our website: www.maxtec.com Flush Flow is the output of the flow meter when the flow indicator is beyond the highest calibrated graduation. The Flush Flow range is as indicated on the flow meter labeling. 2.2 Transport/Storage Requirements: -40 F (-40 C) to 140 F (60 C) The gas and inlet pressures are indicated on the flow tube or flow meter body. NOTE: Storage/transport outside the specified range may cause damage to the flow meter. The above flow meter models are calibrated at specified inlet pressure, 70 F (21 C), standard atmospheric pressure. Specifications are subject to change without prior notice. 866.4.Maxtec www.maxtec.com 3

3.0 OPERATING INSTRUCTIONS 3.1 General Operation NOTE: Maxtec strongly recommends the use of kink proof cannula. 1. Turn knob to the OFF position. 2. Connect the flow meter vertically to the appropriate gas source. The appropriate gas and pressure are specified on the flow meter body. 3. Verify that the float ball is at the very bottom of the flow tube. NOTE: If the float is not resting at the bottom of the flow tube, the product is leaking; consult the TROUBLESHOOTING Section 4.0. 4. Adjust flow: To increase- Turn knob counterclockwise To decrease- Turn knob clockwise 5. Set flow by aligning center of float ball with indicator lines on the flow tube. 6. Adjusting flow beyond the last calibrated indicator line will result in an undetermined flow. 7. To obtain maximum flush flow, turn knob fully counterclockwise. NOTE: Flush flow is any flow above the last calibrated line on the flow tube with an unrestricted flow, as indicated on flow meter labeling. 4 866.4.Maxtec www.maxtec.com

4.0 TROUBLESHOOTING 4.1 Troubleshooting Table If the flow meter fails to function, consult your provider or Maxtec. PROBLEM CAUSE REMEDY Will not shut off Leak Defective valve Sticking float ball Debris in flow tube Unable to set desired flow Replace seals and/or fittings Replace valve Clean flow tube & float ball Blocked inlet Replace filter Knob will not turn Valve seized Replace valve 5.0 RECOMMENDED MAINTENANCE 5.1 Cleaning Instructions: 1. Disconnect all connections before cleaning. 2. Clean exterior surfaces of the flow meter with a cloth dampened with a mild detergent and water. 3. Wipe dry with a clean cloth. Caution: Do Not Autoclave 866.4.Maxtec www.maxtec.com 5

6.0 WARRANTY Under normal operating conditions, Maxtec warrants the Acrylic Flow Meters to be free from defects of workmanship or materials for the following period: a) Acrylic Housing... Lifetime of the product b) Needle Valve...Five (5) years from receipt c) All other parts not listed...two (2) years from receipt Warranty does not cover breakage/abuse. These warranties are from the date of receipt, provided that the product is properly operated and maintained in accordance with Maxtec's operating instructions. Based on Maxtec product evaluation, Maxtec's sole obligation under foregoing warranty is limited to making replacements, repairs, or issuing credit for equipment found to be defective. This warranty extends only to the buyer purchasing the equipment directly from Maxtec or through Maxtec's designated distributors and agents as new equipment. Routine maintenance items, such as o-rings, are excluded from warranty. Maxtec and any other subsidiaries shall not be liable to the purchaser or other persons for incidental or consequential damages or equipment that has been subject to abuse, misues, mis-application, alteration, negligence or accident. These warranties are exclusive and in lieu of all other warranties, expressed or implied, including warranty of merchantability and fitness for a particular purpose. For product warranty returns, please contact Maxtec Customer Service for a Returned Materials Authorization (RMA). 6 866.4.Maxtec www.maxtec.com

Federal law (USA) restricts this device to sale on or by the order of a physician Warning! Not Manufactured with Natural Rubber Latex Storage Temperature Consult instructions for use Manufacturer Made in USA Non-sterile Authorized Representative Contains no Polyvinyl Chloride non sterile PVC Maxtec 2305 South 1070 West Salt Lake City, Utah 84119 USA Toll-Free: 800.748.5355 International: 1.801.266.5300 Website: www.maxtec.com E-mail: sales@maxtec.com QNET Hommerterweg 286 6436 AM Amstenrade The Netherlands 866.4.Maxtec www.maxtec.com 7

8 866.4.Maxtec www.maxtec.com