Confined Space & Gas Detection

Similar documents
Hydrogen Sulfide - Health Effects, Detection and Exposure Prevention

Instructions. To complete this independent study program, view the entire program, advancing through each slide by pressing the enter key.

Recent changes in the rules for confined space entry

Safety Tips from the WorkSafe People. Building a Safety Program for Your Organization

Hydrogen Sulfide (H 2 S) Program

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Confined Space Entry

Atmospheric Hazards. Hazardous Atmosphere 3/29/2017. Oxygen deficiency and enrichment Flammable gases and vapors Toxic contaminants

Gas Detection Technology in Confined Spaces

Health & Safety Policy and Procedures Manual SECTION 34 HYDROGEN SULFIDE (H2S) PROGRAM

Introduction to Confined Space Safety OR-OSHA

Atmospheric Hazards PROGRESSIVE SAFETY SERVICES LLC

Juler Group. Presents. Hydrogen Sulfide (H 2 S) Safety. Juler Group Juler Group Incorporated

An area may be considered a confined space if it meets three criteria.

Louisiana State University Health Sciences Center New Orleans CONFINED SPACE ENTRY TRAINING

Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors

1. Class "A" - an environment that is immediately dangerous to life of health. (Entry by permit only shall have a posted sign.)

Safety Meeting Topic #11 Hazards of Confined Space

HYDROGEN SULFIDE. In the Oilfield

Confined Spaces. 1. Definition Permit/Non-Permit

Section 37 Brieser Construction SH&E Manual

CONFINED SPACE PROGRAM

WorkSafeBC Occupational Health & Safety (OH&S) Regulation: Hazardous Atmospheres and Confined Spaces in Compost Operations

MATERIAL SAFETY DATA SHEET

Confined Space Entry. My Experience so far.

HEALTH AND SAFETY MANUAL

SECTION 9 CONFINED SPACES

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Confined Space Entry - Permits

Hydrogen Sulfide (H2S) Program for Construction

Confined Space Entry Program 8 CCR 5157

Applications Note: Use of "pentane equivalent" calibration gas mixtures

(1) Is large enough and so configured that an employee can bodily enter and perform assigned work; and

MATERIAL SAFETY DATA SHEET

H 2 S in the Oilfield Fact Sheet. Introduction to H 2 S. Where does H 2 S come from? Hazards of H 2 S

Documentation Beats Confrontation in Gas Detection

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET. P.O. Box 4272 CHEMTREC: (800) Houston, TX KRONOS: (800) Customer Service: (800)

MATERIAL SAFETY DATA SHEET. Quick Identifier (In Plant Common Name): PERFECTDATA ADHESIVE SPRAY

Table of Contents. Introduction (Scope, Purpose, Application)...2. Identifying Confined Spaces...2. Identifying Confined Space Hazards..

Intermountain Specialty Gases 520 North Kings Rd, Nampa, Idaho Phone: Fax:

MATERIAL SAFETY DATA SHEET

Not an expected route of exposure.

This free sample provided by CIMC

CONFINED SPACE PROGRAM

CONTENTS. 9. Opening of gas systems containing H 2 S. 1. Introduction. 8. Protection of Personnel.

Confined Spaces OSHA 1926 AA

Kardol Quality Products 285 S. West Street Lebanon, Ohio Fax:

Safety Regulations and Procedures GENERAL SAFETY Confined Spaces - S New 11/96. To provide guidance for the safe entry of confined spaces.

MAPP Gas. Material Safety Data Sheet

Hydrogen sulfide (H 2 S) is an invisible hazard that can be released and produced during industry processes, such as drilling.

SIG SOUTHERN INDUSTRIAL GAS SDN BHD

MANURE GAS DANGERS CHARACTERISTICS OF HYDROGEN SULFIDE (H 2 S)

Employee Safety Toolkit. Employee Safety Toolkit. Notes:

H2S (HYDROGEN SULFIDE) SAFETY TRAINING

Energy Symposium - Combined Session Roughnecks & Master Drillers 8/12/2010. H 2 S It will kill you dead like a rock. Notes. H2S - Charlie Scott 1

Emerging Issues in the Oil and Gas Industry

Material Safety Data Sheet (MSDS)

MATERIAL SAFETY DATA SHEET PAGE 1 OF 4

Cal/OSHA: Confined Spaces

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET Complies with OSHA Hazard Communication Standard 29 CFR

SAFETY AND HEALTH STANDARD CONFINED SPACE ENTRY REQUIREMENTS Effective Date: 06/10/10 Standard: 16.2 Document Number: KUCSH0038 Rev: 07

MATERIAL SAFETY DATA SHEET. Quick Identifier (In Plant Common Name): SP-101

MATERIAL SAFETY DATA SHEET

Entrant / Attendant / Supervisor Training

Confined Space. Program Responsibilities

DANGER! EXTREMELY FLAMMABLE

Confined Space. Key Topics for Facilities

WEEKLY SAFETY MEETING

Process for Identifying Confined Spaces

NIOSH Flowback Study. William G. Burket, CFPS

SAFETY DATA SHEET Isopropyl Alcohol 70% Product Number: 32

SAFETY DATA SHEET. Section 1: Company and Product Identification. Section 2: Hazard(s) Identification. Section 3: Product Composition

Chemical Name CAS Number Weight % ACGIH TLV ACGIH STEL OSHA PELTWA SKIN Acetone ppm N/A 1000ppm Yes

Clear up confusion between the requirements for confined spaces and grain storage structures.

MATERIAL SAFETY DATA SHEET

1.0 Scope and Application. 2.0 Definitions. Cal Poly Risk Management Confined Space Program Page 1

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET Complies with OSHA Hazard Communication Standard 29 CFR

Safety Data Sheet Natural Gas

Safety Data Sheet AERO CHEWING GUM REMOVER. Manufacturer:

M A T E R I A L S A F E T Y D A T A S H E E T

Safety Data Sheet. Tuxton Synthetic Gear Oil 75W90

CONFINED SPACE POLICY

Material Safety Data Sheet For: Die Set Lube MSDS I.D. #135 P/N Quart Size. MSDS I.D. #136 P/N Gallon Size

Progressive Safety Services LLC (c)

Tool Box Talk. Confined Space Entry New Construction Standard (2015)

"CONFINED SPACE ENTRY"

M A T E R I A L S A F E T Y D A T A S H E E T

Material Safety Data Sheet Propane (Odorized) 1. Product Information

HYDROGEN SULFIDE EMPLOYEE TRAINING

Worker Fatalities Associated with Tank Gauging, Thieving, and Sampling

Toolbox Talk. Carbon Monoxide

Safety Data Sheet. Tuxton Select Full Synthetic 0W20 API SN/GF-5

GasLab SAN-102 Micro Oxygen Monitor User Manual

University of Vermont Department of Physical Plant Permit-Required Confined Space Entry Program in accordance with OSHA 29 CFR 1910.

MSHA Mine Gases Training Module Advanced/Refresher Mine Rescue November 1981

MATERIAL SAFETY DATA SHEET

Transcription:

Confined Space & Gas Detection Level 3 Definition of a Confined Space Large enough for worker to enter Are not designed for continuous worker occupancy Limited openings for entry and exit 1

Confined Space Large enough to enter Not Confined Space Confined Space Confined Space Limited means of entry and exit Not designed for continuous worker occupancy 2

Permit Required Confined Spaces One or more of the following: Hazardous atmosphere (known or potential) Material with the potential for engulfment Inwardly sloping walls or dangerously sloping floors or Contains any other serious safety hazard Permit Required Confined Spaces Required atmospheric testing Oxygen Flammable gases and vapors Any known or potential toxic contaminants The above tests shall be done with a calibrated direct-reading instrument, and in that order Before entry it is mandatory to determine that the CS atmosphere is safe! Periodic monitoring is also required Monitor and ventilate continuously (recommended) Monitoring determines the air is safe, ventilation keeps it that way! 3

Non-Permit Confined Spaces Large enough for worker to enter Are not designed for continuous worker occupancy Limited openings for entry and exit Elevator Pit But no other serious safety hazard Typical Confined Spaces Storage tanks Ship compartments Process vessels Underground utility vaults Storm drains Boilers Sewers Tunnels Pipelines 4

Open Topped Confined Spaces Pits Degreasers Open-topped water tanks Ship holds Excavations 5 died trying to save each other By Mike Martindale News Staff Writer MENOMENEE, Mich. Bill Hofer was the first to collapse in the dark manure pit. Inhaling a combination of toxic gases, he quickly lost consciousness and slipped down into the pool of murky liquid in the bottom of the 12-foot hole. Then one after another, the four men at the top of the pit scrambled in, trying first to save Hofer, and then each other, from the deadly fumes. Within five minutes all were dead or dying in what is believed to be the worst farm accident in Michigan history. Killed yesterday along with the 63- year-old Hofer were his uncle, Carl Theuerkauf, Sr., the 65-year old patriarch of the centennial farm; two of Theuerkauf s sons, 37-year old Carl Jr. and 28-year old Tom; and Carl Jr. s 15-year old son, Daniel. I m sure that when one person slipped or fell, out of love and for help, one after another went in, said Richard Breyer with the county farm extension service in Menominee. Dorothy Theuerkauf, who lost a husband, two sons, and a grandson in the tragedy said: I can t believe something like this could happen. It will probably take me a couple of weeks before it actually sinks in. On Thursday, investigators said the five men were using a pump to empty a partially covered, 12-foot deep concrete manure pit, and were almost finished when the pump clogged. Hofer descended into the darkness to clear the block. It s unknown which one went in next, but eventually they all went in to save the rest, said Menominee County Sheriffs Deputy Booth Whipp. County Medical Examiner Dr. Paul Haupt estimates it took about 90 seconds for each of the men to suffocate in the invisible cloud of gas, composed primarily of methane and hydrogen sulfide. 5

Pittsburgh Post-Gazette - Thursday, May 3, 1990 Methane in well kills three firefighters HUSTONTOWN, PA (AP) Residents were mourning yesterday for three volunteer firefighters who died while helping a neighbor to clean out a 38-foot well and were overcome by gas. The deaths were the first in the 25-year history of the 170-member volunteer company in South Central Fulton County said Assistant Chief Robert Cover. James F. Chestnut, Jr., 20, and Richard L. Hersey, 40, both of Hustontown, and Thomas L. Lane, 39, of McConnellsburg, died Tuesday, apparently of Methane gas that had built up in the well. About two dozen other people were treated, including at least six men who inhaled some of the gas. The firefighters went to the home of Nellie Brown on Monday to pump out her well. She had complained of the odor and suspected that an animal had fallen in and died. The volunteers used the pump on their truck without success and returned Tuesday afternoon with a portable pump, state police said. Lane and Larry Traxler of Hustontown entered the well with the pump and took it about halfway down the 3-foot wide shaft. Traxler became dizzy and returned to the surface, but Lane was overcome. Traxler went back for him but lost consciousness. Hersey and Traxler s father, Clair, 41, went in, but Hersey was overcome. Others on the surface then called for additional help. 65% of fatalities due to atmospheric hazards Ref 1 2 3 4 5 6 7 8 9 10 11 12 Accident Type Atmospheric condition in CS Explosion or fire in CS Explosion or fire at point of entry Electrical shock or electrocution Caught in / crushed by machinery Engulfment Struck by falling objects Falls inside Confined Space Ingress / egress Insufficient maneuverability Eye injury Other Events 80 15 23 11 10 16 15 27 33 15 10 21 Injuries 72 49 20 2 3 0 15 26 30 15 10 6 Deaths 78 15 32 9 10 16 0 1 3 0 9 15 Total 276 234 193 6

OSHA 29 CFR 1910.146 Permit Required Confined Spaces Requirements for practices and procedures to protect employees in general industry from the hazards of entry into permit-required confined spaces Does not apply to: Agriculture Shipyard employment Construction 1910.146 General Requirements Options for entry into Permit Required Confined Space (PRCS) Reclassification Alternate entry procedures Permit program 7

Alternate Entry Procedures If a hazard cannot be eliminated, but can be controlled by continuous forced air ventilation, then alternate entry procedures can be used Paragraph (c)(5)(i) lists the conditions under which alternate entry procedures can be used Benefits: Substantially lower equipment requirements No attendants required Solo entries permitted Welding Painting De-greasing Scraping Sandblasting Mucking Inerting Work in confined spaces can produce dangerous atmospheric conditions 8

Confined Space Entry Monitor and ventilate continuously Many accidents result from changes in the CS atmosphere which occur after the entry is initiated Monitoring determines the air is safe, ventilation keeps it that way The only way to pick up changes before they become life threatening is to monitor continuously! Hazard Measurement Three basic kinds of atmospheric hazards Oxygen (deficiency and enrichment) Flammable gases and vapors Toxic contaminants 9

Oxygen Composition of fresh air 78.1 % Nitrogen 20.9 % Oxygen 0.9 % Argon 0.1 % All other gases Water vapor CO2 Other trace gases Oxygen Oxygen Deficiency Most widely accepted definition: Air is oxygen deficient whenever concentration is less than 19.5% OSHA has determined that the leading cause of deaths in confined spaces is asphyxiation 10

Oxygen Deficiency Occurrence associated with: Confined spaces Unventilated cellars Sewers Wells Mines Ship holds Tanks Enclosures containing inert atmospheres Causes of Oxygen Deficiency Displacement Microbial action Oxidation Combustion Absorption 11

Symptoms of Oxygen Deficiency 20.9% Oxygen content in fresh air 19.5% 12% 10% 6% -12% -10% - 6% - 0% Impaired judgment, increased pulse and respiration, fatigue, loss of coordination Disturbed respiration, poor circulation, worsening fatigue and loss of critical faculties, symptoms within seconds to minutes Nausea, vomiting, inability to move, loss of consciousness, and death Convulsions, gasping respiration, cessation of breathing, cardiac arrest, symptoms immediate, death within minutes Toxic Gases and Vapors 12

Toxic Gases and Vapors Toxic atmospheres come from Microbial action on material in CS Products or chemicals stored in CS Work being performed in CS Areas adjacent to Confined Space Toxic Gases and Vapors Detection techniques: Electrochemical Sensors Photoionization detectors Non-dispersive infrared (NDIR) Metal oxide semi-conductor (MOS) Charge carrier injection (CI) 13

Permissible Exposure Limit (PEL) Determined by OSHA Sets limits for legal unprotected worker exposure to a listed toxic substance Force of law in USA! Individual states free to enact stricter, but never less conservative limits Given in Parts-per-Million (ppm) concentrations 1 % = 10,000 ppm Permissible Exposure Limits Parts-per-Million (ppm) concentrations 1.0 ppm the same as: One automobile in bumper-to-bumper traffic from Cleveland to San Francisco One inch in 16 miles One minute in two years One ounce in 32 tons One cent in $10,000 14

Exposure Limits Defined in Three Ways Time Weighted Average (TWA) Ceiling Short Term Exposure Limit (STEL) TWA is Projected Value When monitoring session less than eight hours, TWA projected for the full eight hour shift. When monitoring session more than 8 hours, TWA calculated on an equivalent 8 hour shift basis 15

TWA is Projected Value According to OSHA cumulative TWA exposures for an eight hour work shift are calculated as follows: E = (C a T a + C b T b +... C n T n ) / 8 Where: E is the equivalent exposure for the eight hour working shift C is the concentration during any period of time T where the concentration remains constant T is the duration in hours of the exposure at concentration C TWA Calculation Exposure Time 4 Hours 8 Hours 12 Hours Concentration 100 PPM 100 PPM 100 PPM TWA 50 PPM 100 PPM 150 PPM 16

Ceiling Limit Ceiling is the maximum concentration to which an unprotected worker may be exposed Ceiling concentration should never be exceeded even for an instant Short Term Exposure Limit (STEL) Some gases and vapors have an allowable maximum Short Term Exposure Limit which is higher than the 8 hour TWA STEL values usually calculated as 15 minute, or in some cases, as 5 minute or 10 minute time weighted averages 17

STEL vs. TWA and Ceiling Ceiling STEL TWA 15 min. Carbon Monoxide Produced as a by product of incomplete combustion Associated with internal combustion engine exhaust Vehicles Pumps Compressors 18

Carbon Monoxide Bonds to hemoglobin in red blood cells Contaminated cells can t transport O2 Chronic exposure at even low levels harmful Characteristics of Carbon Monoxide Colorless Odorless About the same weight as air Flammable ( LEL is 12.5 %) Toxic! 19

Symptoms of Carbon Monoxide Exposure Headaches Fatigue Nausea and other "Flu-like" symptoms Loss of consciousness Brain damage Coma Death Toxic Effects CO Concentration of only 1,600 ppm fatal within hours Even lower level exposures can result in death if there are underlying medical conditions, or when there are additional factors (such as heat stress) 20

Exposure Limits for Carbon Monoxide 8-hour TWA STEL Ceiling Federal USA OSHA PEL 50 PPM N/A N/A NIOSH REL (State) 35 PPM N/A 200 PPM TLV 25 PPM N/A N/A Hydrogen Sulfide AKA sewer gas Produced by anaerobic sulfur fixing bacteria Especially associated with: Raw sewage Crude oil Marine sediments Tanneries Pulp and paper industry 21

Colorless Characteristics of Hydrogen Sulfide Smells like rotten eggs (at low concentrations) Heavier than air Corrosive Flammable (LEL is 4.3 %) Soluble in water Extremely toxic! Characteristics of Hydrogen Sulfide H 2 S is mitochondrial poison that prevents utilization of oxygen during cellular respiration, shutting down power source for many cellular processes Also binds to hemoglobin in red blood cells, interfering with oxygen transport Exposure primarily by inhalation, but can also occur by ingestion (contaminated food) and skin (water and air) Once in body, rapidly distributed to central nervous system, lungs, liver, muscle and other organs 22

Toxic effects H2S 0.01 0.1 PPM 10 100 PPM 200 300 PPM 500 700 PPM 1000 PPM Smell Rapid loss of smell Eye inflammation, respiratory tract irritation after 1 hour, loss of consciousness with time Death in 30 min. 1 hr. Immediate respiratory arrest, loss of consciousness, followed by death Combustible Gases Source of ignition Fuel Oxygen 23

Combustible Gases Source of ignition Fuel Oxygen Combustible Gases Lower Explosion Level (LEL) 100% LEL is the concentration of combustible gases or vapors which will explode is sufficient oxygen and a source of ignition is present A combustible hazard exist when the levels exceed 10% LEL 24

Combustible Gases Gas Concentration Flammability Range LEL UEL Combustible Gases Gas Concentration Flammability Range 0 100% LEL 25

Combustible Gases Gas concentrations which equal 100% LEL: Methane 5.0% / vol. Propane 2.2% / vol. Pentane 1.8% / vol. The ratio between the required gas concentration which equals a fully combustible environment (100% LEL) and the LEL sensor response is not linear, however, the order is usually the same Combustible Gases Relative response 100% A B C Meter Reading 50% D E 50% 100% Actual LEL Concentration 26

Combustible Gases Relative response 100% C (Cal) Example: Meter Reading 50% D E 50% 100% Actual LEL Concentration C = Methane (Calibration Gas) D = Propane E = Pentane Combustible Gases Relative response 100% B C (Cal) Example: Meter Reading 50% 50% 100% Actual LEL Concentration D B = Methane C = Propane (Calibration Gas) D = Pentane 27

Combustible Gases Relative response 100% A B C (Cal) Example: Meter Reading 50% 50% 100% Actual LEL Concentration C = Methane D = Propane E = Pentane (Calibration Gas) Combustible Gas Sensor Poisoning 28

Catalytic Combustible Gas Sensors Schematic of Catalytic Hot Bead Combustible Sensor Flame arrestor Compensating bead Active bead Combustible sensors may be poisoned Or suffer degraded performance with Prolonged exposure to: Silicones Tetraethyl-lead Halogenated hydrocarbons High concentrations of sulfides High concentrations of flammable gas Catalytic Combustible Gas Sensors 29

Catalytic Combustible Gas Sensors Catalytic Hot Bead Combustible Sensor With Poisoned Active Bead Flame arrestor Compensating bead Active bead Catalytic Combustible Gas Sensors As an LEL sensor become poisoned the sensors surface and the sensors pores will be coated with oxidized silicone A silicone poisoned sensor will first loose its ability to detect methane, while not exhibiting any noticeable inhibition to detect other combustible gases As poisoning progresses the LEL sensor will eventually lose is ability to detect any combustible gases 30

Catalytic Combustible Gas Sensors While methane may NOT be the preferred calibration gas, it is paramount that the LEL sensor at, a minimum, be challenged with methane gas to confirm that the sensor can still respond adequately to methane. For most applications where the LEL alarm is set to 10% or less, methane is the preferred test gas. Pitfalls in Gas Detection Two biggest pitfalls Can the gas detector detect gas? Will the atmosphere to be tested get to the detector? 31

Verification / Calibration Verify accuracy on a regular basis to guard against any unexpected loss of sensitivity The safest course of action is to expose the sensors to known concentration test gas before each day s use! Never exceed 30 days between verification of sensor accuracy Verification is also called Bump Test Bump Test Vs. Calibration A bump test only provides verification of sensor performance Only necessary to adjust sensor sensitivity if readings are off by more than 10% (Reading that are too high are not a safety concern) Calibration includes adjustment 32

Verification / Calibration Loss of sensitivity can be due to: Aging or desiccation of the sensors, Mechanical damage due to dropping or immersion Exposure to sensor poisons present in the atmosphere being monitored Loss of sensitivity due to other causes Remember bad or depleted calibration gas may be the reason for apparent deficient sensor response Pre-entry Methods Lowering the gas detector into the space to obtain readings in diffusion mode Using a sample-draw system to draw a sample out of the space 33

Diffusion Method Enable the Peak-hold feature to allow the monitor to latch on to the worst case measurements Turn on the flash-lights built in to the detector is available Allow the detector to be at each level to be tested long enough obtain a stable reading (20-30 seconds) Remote Sampling Methods Always test sampling system for leakage and proper flow be for sampling the remote space Hand squeeze aspirators can be tested in just seconds by blocking the inlet and observe that the aspirator remains deflated till the blockage is removed. Motorized pumps should be tested by blocking the inlet at activating the low flow alarm 34

Remote Sampling Techniques Make sure to sample long enough for the sample to reach the sensors Motorized Systems: 1 Sec / Foot or 3 Sec / Meter Manual Systems: 1 Squeeze /Foot or 3 Squeezes per Meter Make sure to sample for sufficient additional time to make the sensors stabilize (20-30 seconds). Remote Sampling Techniques Stratification Atmospheric hazards in confined spaces form layers Test all levels (typically every 4 feet) 35

Questions 36