VACUUM CHAMBER MANUAL

Similar documents
WHP Operations and Methods { July William M. Smethie, Jr. Lamont Doherty Geological Observatory Palisades, New York U.S.A.

Air Tractor Preventative Maintenance Manual And Troubleshooting

Trillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015

easycomposites SETUP & DAILY USE INSTRUCTIONS NEVER SWITCH OFF YOUR PUMP WITHOUT FIRST CLOSING THE VALVE TO THE CHAMBER

Sanatron Vacuum Bubble Leak Tester Operations, Maintenance, and User Manual

USER MANUAL CALIBRATED LEAK STANDARDS

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Service Call: Vacuum Prevention System Testing on Category A and B Aerial Devices. Tools Required: 1. Atmospheric Vent Test Set (P/N )

Leak Checking Large Vacuum Chambers

Oxford Instruments Austin, Inc.

Checklist for care of Respirators

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Installation, Operation, and Maintenance Manual

Pool Owners Guide. As Recommended by Barrier Reef Pools LLC.

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

SILENTAIRE TECHNOLOGY

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

BBB Vacuum Bubble Buster

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Please refer F 90 of the present manual for the identification of the valves used in the detector.

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Oxygen Contamination

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

OPERATION MANUAL NTF-15

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Oxford Instruments Austin, Inc.

OPERATION MANUAL. Hand Held Leak Tester Model # ZUTR-10002

OPERATION MANUAL NTF-60 Plus

CF-SERIES HIGH FLOW REGULATORS

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Multi-Probe Sampling System User Guide & Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

CSA Sample Draw Aspirator Adapter Operator s Manual

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

FloWash. Industrial Filter Cart

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Operating Procedures for Metal Evaporator I

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Welker Constant Pressure Cylinders With Welker Solid Indicator, Syringe T-Handle, or Vortex Mixer

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

User Operation Manual and Safety Instructions

S PRESSURE REGULATOR

ST 18 Aluminium Gas Model

Model ASSEMBLY and OPERATING INSTRUCTIONS

The X-11 Molding Chamber

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

ST 18 Aluminium Gas Model

TactAir PCP Fill Kit/Adapter. Operation Manual

SILENTAIRE TECHNOLOGY

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

GATOR Battery-powered Pistol Grip Cable Cutters

RK-IR Sample Draw Aspirator Adapter Operator s Manual

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

Operation and Maintenance Manual for GENTEC Medical Gas Outlets

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

R I T. Title: STS ASE Semiconductor & Microsystems Fabrication Laboratory Revision: Original Rev Date: 01/21/ SCOPE 2 REFERENCE DOCUMENTS

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Sterile Visual Flow Indicator

Installation, Operation, and Maintenance Manual

15ME-014 INSTRUCTION MANUAL OF STERN TUBE SEALING TYPE EVK2RV. URL

Basic & Controlled Atmosphere Glove Boxes

Rejuvenation Instructions

OPERATING INSTRUCTIONS

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

GREIG FILTERS, INC. OPERATION MANUAL

HYDRAULIC CYLINDER FOR USE WTH:- HVL, HPS, HLS, HSS, HAS, HHS, HHR, HDA & HGS

Cryo-Evaporator Operation

Operating Instructions

PAPR Flow Tester. instructions. part no WARNING

OWNER S MANUAL READ THIS MANUAL BEFORE USING YOUR NEW AIRGUN

Elevator Concepts ltd. by Wurtec Krause Riverview, MI Fax:

G7S Hand Pump Owner s Manual

TECTYL 1422S APPLICATION PROCEDURES AND TROUBLESHOOTING GUIDE

Mass Spec will not pump down

Instructions for use Compressed air injector with water trap

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

T1-Titanium HVLP Siphon Feed Spray Gun

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Installation and Maintenance Manual. Compact Medical Gas Outlets

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

ULTRAMAGIC, S.A. MAINTENANCE MANUAL SUPPLEMENT NUMBER 14 INTRODUCTION OF A VAPOUR PILOT VALVE OPTION FOR THE ULTRAMAGIC MK 21 RANGE OF BURNERS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TRANSPORTABLE CRUDE OIL CONTAINER

GALISO SOAP OPTION FOR PCT-ADW-D

Fisher and Whisper Disk Diffusers

Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

Electron Microscopy Sciences

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

Dean Pump Self-Priming Chemical Process Pumps

Installation and Service Manual

Instruction sheet for Hydraulic Cylinder

Transcription:

VACUUM CHAMBER MANUAL INDUSTRIAL VACUUM CHAMBERS

CONTACT US PHONE/FAX Toll Free: 800.465.1004 Phone: 801.486.1004 Fax: 801.486.1007 ADDRESS LACO Technologies, Inc. 3085 West Directors Row Salt Lake City, UT 84104 WEB www.lacotech.com info@lacotech.com SMT-09-1003 Rev A2 ii

CONTENTS 1. SCOPE... 1 2. SAFETY... 1 3. OVERVIEW... 2 4. BASIC OPERATION... 2 5. MAINTENANCE... 2 6. TROUBLESHOOTING... 3 7. SPARE PARTS LIST... 4 iii

1. SCOPE 2. SAFETY This guide applies to industrial vacuum chambers designed and operated at pressures (vacuum levels) from atmosphere to approximately 0.001 Torr (1 Torr absolute equals approximately 29.88 Hg relative at sea level). The vacuum chamber may achieve a deeper vacuum level with the appropriate vacuum pump, however, this guide is intended for use only when operating within this range. Unless otherwise specified and designed, this vacuum chamber is designed to only be used under vacuum and not positive pressure. If the vacuum chamber is used in positive pressure applications the warranty is voided and the user will place themselves, other individuals, and the equipment in an unsafe condition. CAUTION CAUTION CAUTION Use care when handling the vacuum chamber. Many of the chambers are very heavy. Use proper lifting equipment and safety devices. Do not lift or handle the chamber by the chamber ports, lid or associated valves. Use the provided lifting eyes or the chamber body itself to move larger chambers. Before running a vacuum process, ensure the process has been sufficiently researched and tested in order to prevent unsafe or adverse conditions from occurring. Never place objects or materials in a vacuum chamber that might explode or otherwise become a hazard when exposed to vacuum conditions. Keep all equipment associated with the vacuum chamber in proper and safe working conditions. Ensure all electrical wiring associated with the chamber is done in accordance to standardized electrical codes. If using electricity in or near a metal vacuum chamber ensure the chamber itself is grounded. If the chamber is equipped with a view port, DO NOT operate the vacuum chamber if the view port material is cracked or damaged with deep scratches or gouges. 1

3. OVERVIEW Most LACO industrial vacuum chambers include three main ports: 1. Vacuum port with valve to provide a vacuum source, such as a vacuum pump, to the chamber, 2. Vent port with valve to admit air into the chamber after the vacuum cycle has completed, 3. Gauge port to attach a vacuum gauge. Additional ports are often included for a variety of purposes. 4. BASIC OPERATION With chamber lid or door closed, open the vacuum valve to evacuate the chamber. The chamber air will evacuate and the vacuum pressure can be read via the gauge on the gauge port. Under vacuum conditions the valve can be left open to reach ultimate vacuum or the valve can be closed to maintain the current vacuum (Note that some vacuum pumps might not be designed nor well suited to operating in blank-off conditions and may require a vacuum relief valve to bleed air into the pump. Refer to pump manufacturer manual.) When the chamber is ready to be vented first ensure the vacuum valve is closed and then open the vent valve to vent the chamber back to atmospheric pressure. Never have the vacuum and vent valves open at the same time. If using an oil-sealed mechanical pump with your vacuum chamber never turn off the vacuum pump unless the vacuum valve has first been closed (An alternate method is to close the vacuum valve AND vent the vacuum line before turning of the vacuum pump.). This will minimize the chance of pump oil to be sucked into and contaminate the vacuum chamber. 5. MAINTENANCE Inspect the chamber gasket regularly to ensure no defects or wear have occurred. If cracks begin to appear in the gasket replace it immediately. See the spare parts section for ordering replacement gaskets. Do not clean your gaskets with any solvents as this will shorten the gasket life. To clean gaskets, wipe down gasket with a lint free wipe and DI water. A vacuum grease can be applied to the gasket to help enhance gasket life (see spare parts section). Apply the grease sparingly to the gasket to achieve a smooth, thin film. Regularly clean your chamber to keep your vacuum process running at optimum performance. A dirty chamber may adversely affect your vacuum process, your vacuum pump, chamber gasket, or other vacuum components. Clean your chamber with mild detergent and rinse with DI water. Methanol or other mild solvents can also be used to clean or wipe 2

down the chamber but should NOT be used to clean acrylic chambers. Solvents will cause the acrylic to craze, thereby affecting visibility and chamber life. Use lint free wipes to wipe out chamber. To attain good pump-down performance, ensure the vacuum pump you are using is properly sized for your application and chamber size. If using an oil-sealed pump change the oil regularly (see spare parts section for information on LACO pump oils). 6. TROUBLE- SHOOTING The troubleshooting table below provides assistance to common vacuum problems. Table 1: Troubleshooting PROBLEM CAUSE SOLUTION Chamber will not pump down Chamber evacuates slow Leak in vacuum line Door and gasket not sealing flat Defect in Gasket Vent valve or other valve left open Poor vacuum pump performance Outgassing of product Outgassing of vacuum chamber Leak in system Check hose, hose connections, and clamps Adjust hinge contact LACO for assistance Replace Gasket. See Spare Parts Section. Close Valve Change pump oil. Vacuum pump needs rebuild Minimize outgassing effect, remove offending part Clean vacuum chamber and components Inspect all components of connections. Helium Leak test chamber system, if possible. Perform rate of rise test to see if you have a leak or outgassing problems. 3

7. SPARE PARTS LIST Refer to the table below for a list of replacement gaskets and o-rings for common vacuum chambers. For ordering specialty gaskets or other vacuum chamber replacement parts contact the LACO sales department. Table 2: Spare Parts List P/N DESCRIPTION WHERE USED LG06B L Gasket, BUNA, VAC, 6 DIA All 6 OD chambers LG08B L Gasket, BUNA, Bell Jar, 7.25 All 8 OD chambers LG10B L Gasket, BUNA, Bell Jar, 9.5 All 10 OD chambers LGR12.75 L Gasket, O-ring, 12.75 OD All 12.75 OD chambers LGR18B L Gasket, O-ring, 18 OD All 18 OD chambers LGR24B L Gasket, O-ring, 24 OD All 24 OD chambers LGO11.75B O-ring, BUNA, 12 All 12 clear chambers LGO7.75B O-ring, BUNA, 8 All 8 clear chambers LVODC150 Grease, vacuum, silicone, 5.3 OZ All gaskets and o-rings 4