IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No.

Similar documents
IECEx Cert f cate. of Conformity

slra of Gonformity IECEx Cert f cate )ol4- ob cst

IECEx Certificate of Conformity

@h..p. lntertek. IECEx Certificate of Conformity

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

IECEx Certificate of Conformity

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

Certificate of Conformity

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe

Certification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT

February Cable glands For general industry and hazardous areas

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

IECEx Certificate of Conformity

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

The evolution of the Ex-proof flame path

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Operating Instructions

Operating Instructions

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

Certificate of Conformity

SITRANS P measuring instruments for pressure

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

Junction Boxes Series 8118

IEGEx Gert f cate. of Conform ty

PEPPERS CABLE GLANDS.

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Operating Instructions

Further technical information is available on

CFSW. Hinges with built-in safety multiple switch

Non-Return Valves T55 Series

IP 69 Protection against water under pressure

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

4/2 way Pneumatic Solenoid Valve

CFSW. Hinges with built-in safety multiple switch

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY

ComEx Actuating elements

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Perpetua Power Puck Solutions

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

Terminal Head Section User Guide

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Arran LED Floodlight Luminaire

Mechanical Pressure Measurement

Pre-Start Ventilation System ML 513

Magnetic level switch type MR783 Instruction Manual

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34

BGA158 Series CE Approved Class B Shutoff Gas Valve

IECEx certification of Non-Electrical Ex Equipment

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

ISO Anaesthetic and respiratory equipment Conical connectors Part 2: Screw-threaded weight-bearing connectors

TYPE A Male camlock-female BSPP

THREAD/SCREW - Drill & Tap Chart

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Technical Data. Dimensions

BGA158 Series CE Approved Class A Shutoff Gas Valve

Pressure Measurement Single-range transmitters for general applications

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Dual Solenoid Gas Valve Installation

3.1. Ex-e/i Cable Glands Plastic version for Zone 1, 2, 21 and according to EN : 2012

ISO 3996 INTERNATIONAL STANDARD. Road vehicles - Brake hose assemblies for hydraulic braking Systems used with non-petroleum-base brake fluid

Technical Data. Dimensions

Technical Data. Dimensions

Expansion Thermometers Stainless Steel Series, Model 70

VG5 Supplementary instructions

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

// ADapters GUIDelines

GENERAL APPLICATION NOTES

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

FULL FLOW GAS BALL VALVES: LONDON EN 331 APPROVED. GAS BALL VALVES

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications. Rated operating distance s n 5 mm

ISO 5367 INTERNATIONAL STANDARD. Breathing tubes intended for use with anaesthetic apparatus and ventilators

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Intelligent Traffic Systems:

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

A Unified Marking System for Ex Equipment

L3 Pressure and Level transmitter

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

RTD temperature probes

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Certificate of Compliance

Transcription:

IECEx Cert f cate of Gonform ty INTERNATIONAL ELECTROTECHNIGAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.tecex.com Certificate No. Status: IECEX SIR '13.0094X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 (2014-9-17) lssue No. 0 (2013-1 1- Current 18) 2014-09-17 Page 1 of4 Applicant: Glasshouse Street St Peters Newcastle upon Tyne NE6 1BE United Kingdom Electrical Apparatus: Optionalaccessoltl.' lype 737,747,757,767 and 797 Ranges of Adaptorc, Reducerc and Stopping Plugs Type of Protection: Flameproof, lncreased Safety and Dust Marking Metallic vercions Non-metallic vercions ExdlMb/ExelMb ExellOGb Ex d llc Gb / Ex e llc Gb Ex ta lllo Da Ex ta lllc Da (Note: Ex d I Mb / Ex e I Mb does not apply to aluminium versions) Approved for issue on behalf of the IECEx Ceftification Body: Position: C Ellaby Deputy Certification Manager Signature: (for printed version) Date: 2ât l. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body 3. The Status and authenticity of this certificate may be verifìed by visiting the Website. Certificate issued by SIRA Certification Service Rake Lane Eccleston Chester CH4 9JN United Kingdom t srra CERTIFICATION

B IECEx Gert f cate of Conformity Certificate No IECEx SIR 13.0094X Manufacturer: 2014-09-17 Glasshouse Street St Peters Newcastle upon Tyne NE6 1BE United Kingdom lssue No.: 1 Page 2 o'f 4 Additional Manufacturing location (s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDSI The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0:2011 Edition: 6.0 IEC 60079-1 :2007-04 Edition: 6 IEG 50079-31 :2008 Edition: I IEC 60079-7 ; 2006-07 Edition: 4 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" Explosive atmospheres - Part 31 : Equipment dust ignition protection by enclosure 't' Explosive atmospheres - ParlT: Equipment protection by increased safety "e" This Ce lificate does not indicate compliance with electrical safety and peiormance requirements other than those expressly included in the Sfandards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requiremenfs as recorded in Test Reoort: GB/SlR/ExTR13 0298/00 GB/S I RVExTR I 4.0201 I 00 Qualitv Assessment Report: GB/StRvQAR07.0009/04

B IECEx Cert f cate of Conformity Certificate No : IECEx SIR 13.0094X 2014-09-'t7 lssue No.: I Page 3 of 4 Schedule EQUIPMENT: Equipment and sysferns covered by this cedifrcate are as follows: This certifìcate covers different ranges of metallic and non-metallic adaptors, reducers and stopping plugs, see Certifcate Annexe for a full description of all the products. CONDITIONS OF CERTIFICATION: YES as shown below: 1 2 3 4 5 6 Only one adapter or reducer shall be used per cable entry. The adaptors, reducers and stopping plugs shall be assembled in such a way that their protrusion from an associated enclosure is not increased. The interfaces between a male thread of an adaptor/reducer and an associated enclosure, between a female thread of an adaptor/redueer and a cable entry device, and between a stopping plug and an associated enclosure cannot be defìned. Therefore it is the installer's responsibility to ensure that the appropriate ingress protection level is maintained at these interfaces. Non-metallic adaptors, reducers and stopping plugs shall not be used in enclosures where the temperature, at the point of mounting, is outside the range of -20'C to +60"C. The installer shall refer to the manufacturer's instructions for the action necessary regarding the electrostatic risk associated with non-metallic adaptors, reducers and stopping plugs. Any cable gland used with the non-metallic adaptors and reducers shall be non-metallic and of the A2 type.

IECEx Gert f cate of Gonformity Certificate No.: IECEx SIR 13.0094X 2014-09-17 lssue No.: 1 Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues I and above): lssue 1 - changes: The introduction of 'Ex ta lllc Da' marking for the Type 747 range of stopping plugs, this marking replaces the 'Ex tb llla Db' marking that previously applied. The marking is now common throughout the product ranges; therefore, the description was changed to recognise that there is now no need to detail the marking that s applicable to each product type. 2. The Conditions of Certification were reviewed and revised, whilst most of the amendments are editorial, one of the conditions was removed and a new Condition of Manufacture took its place. 3. The adaptor/reducer cross-reference chart was updated to reflect the option of adaptors and reducers providing up to a maximum of two standard size differences as recognised in the current certification. Annex: IECEx SIR 13.0094X_lss1 Annexe.pdf

Annexe to: Applicant: Apparatus: IECEx SIR 13.0094X Issue 1 Type Ranges of Adaptors, Reducers and Stopping Plugs srra CERTIFICATION Types 737 and 797 Ranges ofadaptors and Reducers The Type 737 Range of Adaptors and Reducers are manufactured from metallic or non-metallic material and are used to convert an existing cable entry apefture to another thread form and/or size in an enclosure. They comprise a hollow hexagonal body, partly threaded from both ends, one end having a male thread and the other a female thread. Additionally, they may be used to conveft an existing cable entry aperture to a different thread form and/or size, When structured as an adaptor the female thread is larger than the male thread, a maximum of two "standard" size differences is allowed. When structured as a reducer the female thread is smaller than the male thread. The adaptors and reducers may also be fitted with an optional O-ring seal, The Type 797 Range of Adaptors with entry thread form sizes between M16 x 1.5 and M100 x 2.0, intended for mounting to a threaded entry po nt on either flameproof or increased safety enclosures. They are metallic in manufacture and are used to convert an existing cable entry aperture to the opposite male or female thread form. They comprise a hollow body partly threaded from both sides with either male threads or female threads at each end. Additionally, they may be used to convert an existing cable entry apefture to a different thread form and/or size. Thread combinations are such that a maximum of two 'standard' size differences is maintained, The male to male threaded adaptors may also be fitted with optional O-ring seals, Design options for the Type737 and797 ranges: Typical threadforms: Note: Table below shows one'standard'size difference; other combinations are possible as detailed above. ET Conduit PG BSPP BSPT ISO NPT NPT NPSM BSW Adaotors Female threadform Male threadform M20 x 1.5x M16 x 1.5x M25 x 1.5 M20 x 1.5 M32 x 1.5 M25 x 1.5 M40 x 1.5 M32 x 1.5 M50 x 1.5 M40 x 1.5 M63 x 1.5 M50 x 1.5 M75 x 1.5 M63 x 1.5 M90 x 2.0 M75 x 1.5 M100 x 2.0x M90 x 2.0x Reducers Female threadform Male threadform M16 x 1,5 M20 x 1.5 M20 x 1.5 M25 x 1.5 M25 x 1.5 M32 x 1.5 M32 x 1.5 M40 x 1.5 M40 x 1.5 M50 x 1.5 M50 x 1,5 M63 x 1,5 M63 x 1.5 M75 x 1.5 M75 x 1.5 M90 x 2.0 M90 x 2.0x M100 x 2.0x i. The Type737 is available in non-metallic and metallic sizes. Those marked x are for metallic sizes, only, i. Intermediate sizes of threads within the range above providing the same or greater wall thickness eg. M80 Alternative nearest equivalent male threadforms: BS 31:1940 (1979) DIN 40430:1971 BS 2779:1973 BS 21:1985 ISO 717:t982 (metallic designs only) ANSr/ASM E 81.20. 1-1983 USAS 82.1.20.1-1968 (metallic designs only) ANSr/ASM E 81.20. 1-1983 BS 84:1956 (metallic designs only) Alternative materials of manufacture: Brass - BS EN 12164:1998/851400 Aluminium - BS EN 755 Part 6:1996/85 EN 1706 (Not Group I) Mild Steel - BS EN 10088 Part 3:1995 Stainless Steel - BS EN 10088 Part 3:1995 Glass reinforced flame retardant nylon (737 range only) (Not Group I) Date: 17 September 2014 Form 9530 Issue 1 Page 1 of 2 Sira Ceftification Service Rake Lane, Eccleston, Chester, CH4 gjn, England Tel: Fax: Email: Web: +44 (0) 1244 670900 +44 (0) 1244 681330 info@siracertification.com www.siracertifi cation.com

Annexe to: Applicant: Apparatus: IECEx SIR 13,0094X Issue 1 Type Ranges of Adaptors, Reducers and Stopping Plugs srra CERTIFICATION Types 747t757 and767 RangesofStopping Plugs The Type 747 Range of Stopping Plugs are manufactured from metallic or non-metallic material and comprise a cylindrical body with an external male thread along its length with the exception of a poftion at one end. Each has a socket head recess to allow fitting and removal. The Stopping Plugs are available in two forms designated as either non-tamperproof or tamperproof by the manufacturer. When fitted into an enclosure, the socket head recess of the non-tamperproof version is accessible from the outside, whilst the socket head recess of the tamperproof version is only accessible from the inside. The Type 757 Range of Stopping Plugs are manufactured from metallic or non-metallic material and comprise a rylindrical body with an external male thread along its length with the exception of a hexagonal head at one end. The body may also be fitted with an integral 'O' ring seal. The Type 767 Range of Stopping Plugs are manufactured from metallic or non-metallic material and comprise a cylindrical body with an external male thread along its length with the exception of a domed head to one end. The face of the domed head contains a socket head recess to allow fitting and removal. The body may also be fitted with an integral 'O' ring seal. Design optionsforthetypet4t,tst and767 ranges of Stopping Plugs: Typical threadforms: M16 x 1.5 (metallic sizes only) M20 x 1.5 M25 x 1.5 M32 x 1,5 M40 x 1.5 M50 x 1.5 M63 x 1.5 M75 x 1.5 M90 x 2.0 M100 x 2.0 Alternative nearest equivalent male thread forms to the metric sizes listed above may be utilised from the following types: ET Conduit - BS 31:1940 (1979) PG - DIN 40430:T977 BSPP - BS 2779:1973 BSPT - BS 21:1985 ISO - ISO 7lt:I982 (metallic designs only) NPT - ANSr/ASME 81.20.1-1983 NPT - USAS 82.1.20.1-1968 (metallic designs only) NPSM - ANSr/ASME 81.20.1-1983 BSW - BS 84:1956 (metallic designs only) Alternative materials of manufacture: Brass - BS EN 12164:1998/851400 Aluminium - BS EN 755 Paft 6:1996/85 EN 1706 (Not Group I) Mild Steel - BS EN 10088 Part 3:1995 Stainless Steel - BS EN 10088 Paft 3:1995 Glass reinforced flame retardant nylon (Not Group I) Condition of manufactu re The Manufacturer shall comply with the following: 1. Non-metallic and aluminium adaptors, reducers and stopping plugs shall not be bear any group marking information, Date: 17 September 2OL4 Form 9530 Issue 1 Page2 of 2 Sira Gertification Service Rake Lane, Eccleston, Chester, CH4 9JN, England Tel: +44 (0) 1244 670900 Fax +44 (0) 1244681330 Email: info@siracertifìcation.com Web: www.siracertification.com