Monitoring Carbon Dioxide

Similar documents
Chem Bio Liquid Nitrogen Facility

Controlling Benzene Exposure

Juler Group. Presents. Hydrogen Sulfide (H 2 S) Safety. Juler Group Juler Group Incorporated

SAFETY ANALYSIS OF CO 2 AS A REFRIGERANT IN SUPERMARKET REFRIGERATION

"CONFINED SPACE ENTRY"

An area may be considered a confined space if it meets three criteria.

SAFETY TRAINING LEAFLET 06 CARBON DIOXIDE

NIOSH Flowback Study. William G. Burket, CFPS

Hydrogen Sulfide - Health Effects, Detection and Exposure Prevention

MANURE GAS DANGERS CHARACTERISTICS OF HYDROGEN SULFIDE (H 2 S)

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

MATERIAL SAFETY DATA SHEET

SIG SOUTHERN INDUSTRIAL GAS SDN BHD

TEXAS TECH UNIVERSITY HEALTH SCIENCES CENTER EL PASO

Confined space entry. In defining a permit-required confined space, the standard lists the following characteristics:

MATERIAL SAFETY DATA SHEET MSDS DATE: 7/08/09 SCENT WINTERGREEN SUPERSEDES: 6/23/08

H 2 S in the Oilfield Fact Sheet. Introduction to H 2 S. Where does H 2 S come from? Hazards of H 2 S

MATERIAL SAFETY DATA SHEET MSDS DATE: 9/3/ Surfactant SUPERSEDES: None

HAZARD COMMUNICATION STANDARD: SAFETY DATA SHEETS (SDS)

Teamsters Hazardous Waste Worker Training Initial Hazardous Waste Site Worker Course

Standards of Practice Respiratory Protection: Appendix C

Material Safety Data Sheet

Section 37 Brieser Construction SH&E Manual

MATERIAL SAFETY DATA SHEET MSDS DATE: 8/14/12

Health & Safety Policy and Procedures Manual SECTION 34 HYDROGEN SULFIDE (H2S) PROGRAM

Safety Data Sheet SUREPREP SKIN PROTECTANT WIPE

DUQUESNE UNIVERSITY. Liquid Nitrogen Safety

Health and Safety Executive/Local Authorities Enforcement Liaison Committee (HELA)

MATERIAL SAFETY DATA SHEET MSDS DATE: 3/13/12

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Confined Space. Program Responsibilities

SIZING OF WATER PIPING SYSTEM

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET Complies with OSHA Hazard Communication Standard 29 CFR

RAZE DR 8810 MATERIAL SAFETY DATA SHEET ESSENTIALLY SIMILAR TO OSHA FORM 174

SDS. GHS Safety Data Sheet. Wechem, Inc. APACHE PRODUCT AND COMPANY IDENTIFICATION. Manufacturer HAZARDS IDENTIFICATION

Total Systems Technology Inc. Address 65 Terence Drive, Pittsburgh, PA Phone Number Emergency Phone Number

Section I - IDENTIFICATION SEMENT PATCH SYSTEM. (407) (800) Chemtrec Section II - HAZARDOUS INGREDIENTS PEL. 0.1 mg/m 3 0.

MATERIAL SAFETY DATA SHEET Complies with OSHA Hazard Communication Standard 29 CFR

Material Safety Data Sheet. Helmar Crystal Kote Picture Varnish Gloss

Material Safety Data Sheet

Automatic LN2 Fill Station Instructions

BOSS LUBRICANTS: MATERIAL SAFETY DATA SHEET

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE

Safety Data Sheet EPI-CLENZ PLUS INSTANT HAND SANITIZERS

SAFETY DATA SHEET. Section 1. IDENTIFICATION

Material Safety Data Sheet. Helmar Crystal Kote Fixative

Bark-Mark Boundary Blaze Orange

Safety Data Sheet SUREPREP NO-STING SKIN PROTECTANT

PRODUCT SAFETY DATA SHEET Product name: Classic Plastic

Confined Spaces. 1. Definition Permit/Non-Permit

SAFETY DATA SHEET. May be irritating to the eyes, nose, throat, and lungs. Repeated exposure may cause skin dryness or cracking.

SAFETY DATA SHEET SECTION 1 IDENTIFICATION. MB4908 Product Line

Material Safety Data Sheet

Confined Space Entry - General Industry & Construction. Leader s Guide and Quiz

MATERIAL SAFETY DATA SHEETS

Liquid Oxygen- Helios & Helios Marathon A Guide for Patients in the Home

MATERIAL SAFETY DATA SHEET

Hydrogen Sulfide (H2S) Program for Construction

FAIRFIELD COUNTY RURAL FIRE BOARD GUIDELINES AND STANDARD OPERATING GUIDELINES. SCOPE: This guideline applies to all Fairfield County personnel.

COATINGS SPRAY GUIDE Urethane 520

Standard Operating Procedure

9. Extended Range Instructor

MATERIAL SAFETY DATA SHEET

Product Name: PUNCTURE SEAL INSTANT TIRE REPAIR (UPC: )

Introduction to Confined Space Safety OR-OSHA

AIR CONDITIONING AND PRESSURIZATION CONTROLS AND INDICATORS

MATERIAL SAFETY DATA SHEETY Complies with OSHA Hazard Communication Standard 29 CFR

MATERIAL SAFETY DATA SHEET

Liquid Gas Cylinder (LGC)

MATERIAL SAFETY DATA SHEET

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

SAFETY DATA SHEET SECTION I - PRODUCT AND COMPANY IDENTIFICATION

Safety Tips from the WorkSafe People. Building a Safety Program for Your Organization

This symbol denotes what could lead to serious injury or death if you misuse the PAR-F27MEA. WARNING CAUTION

GasLab SAN-102 Micro Oxygen Monitor User Manual

Confined Space Entry and Permitting

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Page Number: 1 of Health: 2 Fire: 1 Reactivity: 0 PPI:

Material Safety Data Sheet

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET COMPANY: HAYCARB HOLDINGS (AUST) PTY LTD

Material Safety Data Sheet

COATINGS SPRAY GUIDE Fast Set Urethane 530

SAFETY DATA SHEET. Section 1: Company and Product Identification. Section 2: Hazard(s) Identification. Section 3: Product Composition

CHEMICAL PRODUCT SAFETY DATA SHEET FISPQ. Product: ADETEC ND 22 Date of last revision: 11/01/2010 Page: 1 of 5

M a t e r i a l S a f e t y D a t a S h e e t

Version /08/2003

Product Identifier: Supercedes Date: 7/30/2015

Standard Operating Procedure (SOP)

SIZING OF WATER PIPING SYSTEM

}?BASF. Safety data sheet 2. HAZARDOUS INGREDIENTS 3. HAZARDS IDENTIFICATION 1. SUBSTANCE/PREPARATION AND COMPANY IDENTIFICATION.

Emergency Telephone Number: Chem-Tel, Inc Outside the United States call SECTION I - PRODUCT IDENTIFICATION

Recreational Camp Emergency Plans for Incidents and Natural Disasters

SAFETY DATA SHEET Odor-B-Gone. 1. Product and Company Identification. 2. Hazards Identification

MATERIAL SAFETY DATA SHEET

GasLab SAN-102 Micro Oxygen Monitor User Manual

Material Safety Data Sheet

HAZARD COMMUNICATION STANDARD: SAFETY DATA SHEETS (SDS)

Material Safety Data Sheet

Transcription:

Monitoring Carbon Dioxide Note: This protocol is subject to revision. This version is as of Wednesday, 19 June 2002. Exposure Limits In the United States, the current OSHA permissible exposure limit (PEL) for carbon dioxide is 0.5% time-weighted-average, for an eight-hour period. There is also a higher short term exposure limit (STEL) of 3% time-weighted average for a period of no more than 15 minutes. There is a proposal to raise the OSHA PEL from 0.5%, to 1%, and that is expected to be approved soon, but right now the eight-hour limit is 0.5% Measuring the General Idea Carbon dioxide levels are monitored in PLASA s fog testing program by using the Crowcon Safegard II. This machine gives instantaneous readings of CO 2 levels up to 5%. It flashes a red light and sounds a beeping alarm at 0.5% up to 1%. At 1% and above, it shows the red light and sounds the alarm continuously. The meter uses infrared absorption technology to measure the amount of carbon dioxide. The sensor is located behind the small grill above the display, and light behind the grill pulses while the Safegard is on. Dry ice fogs and low-lying glycol fog machines that use liquid carbon dioxide put CO 2 into the air. The carbon dioxide is present in the fog effects, and is also released into the air by dry ice while in storage and by liquid carbon dioxide while stored in low-pressure dewars. Carbon dioxide is heavier than air, particularly when cold, and this released carbon dioxide, besides being in the fog on stage, can collect in low-lying areas where the fog settles, and in storage spaces where dry ice or liquid CO 2 dewars are kept. Carbon dioxide levels that are too high can be hazardous, so steps should be taken to monitor CO 2 levels. It s not very useful to try to measure all the air everywhere, so practical monitoring focuses on measuring the air people are likely to breathe in the fog effect, in low-lying areas where the fog settles, and in storage areas. If the results of these measurements give you numbers within appropriate limits, you are set. If those measurements give you numbers outside appropriate limits, the fog effect, the location of the people, or the ventilation needs to be changed. Note: Fog is by nature variable, so it s recommended that users run the tests three times and take the average reading. Measuring the Fog Effect Step-by-Step 1. Figure out who is in the densest fog or in the fog the most time. Don't forget to consider the backstage crew members as well as the cast. Note where the mouth and nose of that person is while he or she is in the fog. 2. Set up the show conditions the conditions that will exist when the person is in the fog. Make sure that the air conditioning or heating is on or off, as the case may be, that scenery and curtains are where they are when the person is in the fog, or are moving if

that's what they do during the cue. Make sure that doors normally closed are closed, and that doors normally open are open. 3. Turn on the Safegard. Press the big black button with the yellow ring on the front of the unit. The display will show Crowcon Safegard for about 20 seconds. The display will then change to show Crowcon x.xx%co2 (Where x.xx equals some percentage.) The unit will beep every 30 seconds to show that it's on. 4. Run the fog cue with the Safegard in the fog where the person will be, and measure the CO 2 in the fog. Run the fog cue under show conditions with the monitor near where the person's mouth and nose will be during the cue. If the person walks into the fog, out of the fog, or moves through it, move the monitor to duplicate those moves. Try to duplicate the person's speed and timing; don't rush and don't linger. Make sure that you don t block the air intake port above the display or breathe into it. Note if the Safegard's alarm goes off at any time. 5. If the alarm never sounds. If the alarm never sounds, the CO 2 level is never above 0.5%, and the OSHA PEL is not exceeded. There is so little CO 2 in the fog that nothing needs to be done about it, and you can go on to measuring the CO 2 in the places where the fog settles and in the dry ice or liquid CO 2 storage areas. 6. If the alarm sounds. If the alarm sounds, you need to collect data to determine the time-weighted average levels. After clearing the air, note the ambient level of CO 2. Then run the fog cue again, but this time note the readings on the Safegard every 30 seconds. Stop noting the readings when the fog cue is over and the CO 2 is back to ambient levels. Record the total time you took readings. NOTE: If the CO 2 levels are 5% or higher, leave the area. The CO 2 level is too high to read with the Safegard, and may be at a level that is an immediate serious hazard. Levels above 7% can cause unconsciousness in a few minutes. Higher levels can cause death. 7. Turn off the Safegard. Press the big black button and hold it for three seconds. The Safegard will give a sustained beep, and then shut off. Fog is by nature variable, so it s recommended that users run the tests three times and take the average reading.

Judging the Eight-Hour TWA Exposure Levels The data collected in step 6 needs to be converted to a time-weighted average. If the data is collected at regular intervals, this simple formula will give the time-weighted average over the sampling period: (C 1 + C 2 + C 3 +... + C N )/N = C TWA Where C is the concentration at a moment in time and N is the number of samples. The 8-hour time-weighted average needs to be calculated from the results of the above calculation and the ambient CO 2 levels. Remember that people are never away from CO 2 even when they are out of the fog. The ambient level of CO2 in the open air is about 0.03%, but indoors it can be well above 0.1% simply from people breathing. (C TWA T fog + C ambient T ambient )/480 = E Where: E is the equivalent 8-hour exposure C TWA is the TWA CO 2 level during the measured period of time in the elevated levels due to the fog effect, T fog T fog is the measured period of time in the elevated levels due to the fog effect expressed in minutes C ambient is the ambient TWA CO 2 level T ambient is the time expressed in minutes in which the person is in the ambient CO 2 environment during an 8-hour (480-minute) period during which the fog cue is run. For example, if the elevated levels (T fog ) lasted 15 minutes, the time at ambient levels (T ambient ) is 465 minutes. If the person is in the fog several times during the day, you need to compute the cumulative exposure with the following formula: E 8-hour = (C a T a + C b T b +... C n T n + C ambient T ambient )/480 In this case, C a T a, C b T b, and so on, are the TWA CO 2 levels and exposure times in minutes for each of the fog cues. If the eight-hour TWA level is below the OSHA PEL, this is good news, and you can move on to judging the short-term exposure. If the eight-hour TWA is above the OSHA PEL, you need to do something to reduce the person's exposure to CO 2. Since carbon dioxide is heavier than air and tends to hug the floor in a fog effect, simply raising the person's face further from the floor may solve the problem. For example, it's generally not a good idea to have a performer lie down in dry ice fog because that puts the performer's face close to the floor where the CO 2 is the most concentrated. Moving the person away from the fog machine's outlet may also do the trick. It may be necessary to lighten the fog effect by using less dry ice or less liquid CO 2, or to shorten the duration of the effect. Careful siting of the fog equipment and the use of hoses, ducts or fans can put the fog in front of or around a person, and leave the person in a relatively fog free area. Careful use of lights can make a small amount of fog look denser than a lot of fog, poorly lit. Alternatively, if the ambient level of CO 2 is fairly high, the eight-hour TWA can be improved by increasing the ventilation and thus lowering the ambient level of CO 2 in the air. Whatever you do

to control the exposure, write it into the operating procedures for the show so it will be done consistently. Judging the 15-Minute Short-Term Exposure Levels Take a look at the data you collected during the fog cue. If none of the levels is 3% or above, you can meet the requirements of the OSHA STEL be simply making sure that the time period where the CO 2 level is above the PEL is 15 minutes or less. If you recorded several levels at 3% or any above 3%, you need to calculate the time-weighted average short-term exposure over a 15-minute period. To calculate the short-term exposure, look at the data you collected and note any 15-minute periods that seems to have high peak levels. Using the measurements you took during these 15- minute periods, calculate the time-weighted average over the sampling periods. (C 1 + C 2 + C 3 +... + C N )/N = C TWA The concentration should not exceed the OSHA STEL, which is 3%. If it is higher, you need to do something to reduce the person's exposure to CO 2. Since carbon dioxide is heavier than air and tends to hug the floor in a fog effect, simply raising the person's face further from the floor may solve the problem. Moving the person away from the fog machine's outlet may also do the trick. It may be necessary to lighten the fog effect by using less dry ice or less liquid CO 2, or to shorten the duration of the effect. Careful siting of the fog equipment and the use of hoses, ducts or fans can put the fog in front of or around a person, and leave the person in a relatively fog free area. Careful use of lights can make a small amount of fog look denser than a lot of fog, poorly lit. Whatever you do to control the exposure, write it into the operating procedures for the show so it will be done consistently. Measuring Fog Where It Settles Low-lying fog effects have a tendency to run off the stage into orchestra pits and other low-lying areas, carrying carbon dioxide with them. These areas should be checked. Use the procedure outlined for "Measuring the Fog Effect Step-by-Step" but check the levels for all the people who might be in these low-lying areas, not only those who look like the most fog is falling on them. Judge both the levels against both the OSHA PEL and STEL. If the levels are above the OSHA limits, something needs to be done to lower the exposure levels, but the options available are a little different than they are for dealing with a fog effect on stage. For example, if excessive CO 2 levels are found in an orchestra pit, it is usually not practical to move the musicians out of the pit, although that would solve the problem. However, it is often practical to increase the flow of fresh air into the pit or to block the flow of the fog and CO 2, either with a low barrier at the edge of the stage, or with fans opposing the flow of the fog and diverting it elsewhere. Whatever is done, write it into the operating procedures for the show so it is done consistently every time. Be particularly careful of solutions that involve adding or increasing mechanical ventilation. It is easy to solve the problem by increasing the fan speed on the air conditioning, only to have someone else turn down the fan later to reduce noise.

Measuring Fog Storage Areas Dry ice and liquid carbon dioxide in dewars should not be stored in confined areas, particularly confined areas with poor ventilation. In any case, areas where dry ice or liquid carbon dioxide in dewars are kept should be checked for excessive carbon dioxide levels. The solid dry ice will slowly turn to gas and add CO 2 to the air around it. The low-pressure dewars hold cold liquid CO 2, which, as it gains heat from the surroundings, evaporates and builds pressure inside the dewar. To control the pressure, a vent releases CO 2 into the air. If the dry ice or dewar is stored in a place with poor ventilation, high levels of CO 2 may result in the storage area. Turn on the Safegard while away from the CO 2 storage area. Then, with the Safegard turned on, go the storage area and use the procedure outlined for "Measuring the Fog Effect Step-by- Step" to check the levels for anyone who might enter the area. If you find levels that are above the PEL but below the STEL, do not assume that you don't have to address the situation because no one goes into the storage area for longer than 15 minutes. Unless you have a reliable way of controlling access to the storage area, it is better to assume that someone might go there and stay all day. Thus, it would be appropriate to work to stay below the PEL and not the higher STEL. NOTE: If during your measurements, or at any time while the Safegard is on, the CO 2 level is 5% or higher, leave the area immediately. The CO 2 level is too high to read with the Safegard, and may be at a level that is an immediate serious hazard. Levels above 7% can cause unconsciousness in a few minutes. Higher levels can cause death. Do not try to re-enter the area until you have ventilated it to reduce the CO 2 level. If the CO 2 level is higher than the PEL, reducing the entry of CO 2 into the air in the storage area is likely to be impossible, so increasing the ventilation will be the solution. However, if this is done with mechanical ventilation, make sure that it can't be turned off. It is not uncommon for ventilation in a theatre to be shut off during the day, which could result in the accumulation of high CO 2 levels by evening. Natural ventilation is more reliable; a drafty loading dock is often a better storage space than is an unused dressing room in a theatre's basement. Also, a little carbon dioxide added to a large space will have much less effect than the same amount added to a small space, so a large storage area is much better than a small one. Avoid confined spaces. Questions? Call 212-244-1505 during normal business hours, or send an email to standards.na@plasa.org. PLASA 630 Ninth Ave., Ste. 609 New York, NY 10036 USA Phone: +1-212-244-1505 Fax: +1-212-244-1502 standards.na@plasa.org