LEVEL Transmitters. ) of the liquid column above it and the atmospheric pressure (P atm

Similar documents
High-performance submersible pressure transmitter For level measurement Model LH-20

NivuBar Plus II

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-10

Expert Hydrostatic Level Transmitters

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

High-performance submersible pressure transmitter For level measurement Model LH-20

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Pressure Measurement Single-range transmitters for general applications

9700 Transmitter Submersible hydrostatic level transmitter

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

SITRANS P measuring instruments for pressure

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Hidrostatic Level DATASHEET

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Hydrostatic Level Measurement waterpilot FMX 160

OPTIBAR P 1010 C Technical Datasheet

Pressure Transmitters 36 F-27839

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Level transmitter LT 100

Submersible pressure sensor High-performance Model LH-20

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

JUMO MAERA. Level probes Types , , , Installation Instructions T94Z001K000 V4.00/EN/

SPD310/SPD360 Air Differential

How to specify a product. Process Sensors and Mechanical Instruments

Pressure transmitter PASCAL Ci4

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

C-Flow Coriolis Mass Flow Meters

Pressure Measurement Single-range transmitters for general applications

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

L3 Pressure and Level transmitter

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Hydrostatic Level and Pressure Measurement

200A Series ELECTRONIC LEVEL TRANSMITTER

Hydrocont B Hydrostatic filling level sensor 40mm

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Ultrasonic level transmitter and indicator

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Differential pressure

VG5 Supplementary instructions

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Gas density monitor With integrated transmitter Model GDM-100-TI

EASIDEW TRANSMITTER with Current Source Output

JUMO dtrans p30 Pressure Transmitter

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Pressure Transmitter P41

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Bourdon tube pressure gauge for diaphragm seals

Type S-10, S-11 General Purpose Pressure Transmitters

Level sensing relative and absolute pressure transmitter type 712

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

2/2-way proportional valve

Liquid level instruments BM 24 /BM 51

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Pressure Switches Application Guideline

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

better measurement Simply a question of

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

SonoMeter 30 Energy Meters

Differential Pressure Transmitter deltabar S PMD 25 K for use in Nuclear Power Plants

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

ATM - Analog Pressure Transmitter

ATM.1ST/Ex - High Precision Transmitter

Mass Flow Meter (MFM) for gases

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

Climatic Independent Level Sensor LAR

CDP-100S Pressure Type Level Transmitter

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

ATM/Ex - Analog Pressure Transmitter

[Instruments for vacuum measurement, checking and adjustment] 3

ASIC-Based Small Bore Submersible Level Transducer

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

780S Ultra High Purity Series

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Transcription:

Hydrostatic level transmitters nivopress N GENERAL DESCRITION The NIVORESS N hydrostatic level transmitters are designed to measure the level of clean or contaminated liquids. The pressure sensor at the bottom of the probe measures the sum of the hydrostatic pressure ( hydr ) of the liquid column above it and the atmospheric pressure ( atm ). The atmospheric pressure is led to the sensor through a breathing capillary which is equipped with a moisture filter that prevents the moisture reaching and damaging the electronics. This enables the atmospheric pressure to be subtracted from the measured pressure to get the hydrostatic pressure which is proportional to the height of the liquid column (h). The electronics converts the sensor s signal into an output signal. If temperature measurement (of the liquid) is needed beside the level measurement a combined (level + temperature) transmitter should be used. The installation and wiring of the transmitter is helped by the wide variety of accessories. A sewage adapter working on the principle of the diving bell can be snapped into the place of the protecting cap to avoid the direct contact between the sensor and the measured contaminated liquid. An extra mechanical protection is built in the NZ type transmitters in the form of a mechanical filter. The N-500 types can be used in hazardous environments. The NZ screw-in type transmitters are recommended for applications where there is a risk of flooding. The NB/NG plastic housing types are designed for those applications where the aggressive medium (e.g. saline solutions or seawater) could cause galvanic corrosion of the stainless steel body. MAIN FEATURES Measuring range up to 656 ft Remote programmable I68 protection Submersible or screw-in types Ø 0.85 / 1 inch tube HART communication 2- or 3-wire versions Ex versions 2 x 4 20mA output (level + temperature) Built-in t100 temperature sensor Overvoltage and inverse polarity protection Wide range of accessories Approved for potable water Available with capacitance ceramic, piezorezistive stainless steel or ceramic sensor ALICATIONS Level and temperature measurement of drinking water wells, tanks, pools Submersible pump control Screw-in submersible type with I68 protection for applications with risk of flooding Clean or slightly polluted, contaminated liquids Sewage waters Draw-down protection Sewage lift station control Saline solutions, seawater CERTIFICATIONS ATEX approved (Ex ia) moisture filter OV-32/33 overvoltage protection unit NAA-101 / NAA-102 cable terminal box N /NK NC NAA-105 cable holding sliding sleeve NB NB + NAW-107 sewage adapter NZ / ND NZ / ND + NAZ-103 sewage adapter N / NK + NAW-104 sewage adapter OV-22/33 overvoltage protection unit NAA-209 cable mounting unit 37

TECHNICAL DATA 2-wire 3-wire NB, NG NK, NN / ND, NH NC, NT N, NF / NZ, NR NH, NFH / NZH, NRH rinciple iezoresistive Capacitance iezoresistive Sensor type Material Ceramic Stainless steel Housing lastic Stainless steel 0 to 65 ft (0 to 20 m) water head 0 to 656 ft (0 to 200 m) water head Measuring range As per order code; the current output can be customized in the pressure range from 2% to 130% with remote programming Overload allowed (versus range) 3 x 20x (h 3 mvo) 10x (h > 3 mvo) Output 4 20 ma + HART 4 20 ma 4 20 ma + HART 0 10V (0 V 80 mv) measured to the power supply ower supply 12 30 V DC 18 30 V DC / 6 ma ND and NZD types: power supply: 12 30 V DC / 4 20 ma; 32 F to 140 F, Accuracy: ±5,4 F Temperature measurement No types: t100 B temperature sensor, other types with HART output: temperature can be queried as HART Secondary Value, Accuracy: ±5,4 F Linearity error (level) ± 0.45 % ± 0.25 % Temperature error ± 0.1 % / 10 K ± 0.2 % / 10 K rocess temperature (1) -22 F to 140 F rocess connection NAA-209 cable mounting wedge clamp, NZ, NR, ND, NH types: ¾ BS thread Ingress protection I68 Electrical protection Class III. Electrical connection Shielded cable with breathing capillary Cable Ø 0.275 inch; AWG22 Cable length 0... 985 ft (0... 300 m) as per order code 3 x Dimensions Ø 1x8.3 inch NK,NN: Ø 0.87x6.8 inch ND,NH: Ø 1.5x6.85 inch Ø 1.55x5.75 inch N,NF: Ø 0.87x6.8 inch NZ,NR: Ø 1.5x6.85 inch Mass Material of wetted parts robe: 0.33 lb NK,NN: robe: 0.44 lb ND,NH: robe: 0.66 lb robe: 0.88 lb N,NF: robe: 0.44 lb NZ,NR: robe: 0.66 lb Sensor Al 2 O 3 316L (1.4404) Housing OM 316 Ti (1.4571) Cable coating olyurethane (UR) or FE Sealings VITON (FKM) rotecting cap OM 316 Ti (1.4571) 316 Ti (1.4571) SECIAL DATA FOR Ex CERTIFIED MODELS N / NF / NZ / NR / NK / NN / ND / NH -5 - Ex rotection type Intrinsically safe Ex marking Intrinsically safe data See: www.nivelco.com ower supply 14 30 V DC Operation temperature range -22 F to 140 F 38 TECHNICAL DATA OF ACCESSORIES Cable terminal box NAA-101 Dimensions 3.66 x 3.66 x 2.16 inch Ingress protection I65 rocess temperature range 40 F to +158 F Material olystyrene Cable gland M20x1.5 (cable outer diameter: 0.2... 0.4 inch) Electrical connection Terminal block (for max. AWG13 wire cross section) Cable terminal box with overvoltage NAA-102 protection Data See: NAA-101 Electrical data See: OV (1) High temperature (up to 167 F (75 C)) version is available on special request (2) Only for 2-wire 4 20 ma equipments Cable mounting wedge clamp NAA-209 Max. mechanical load 985 ft (300 m) cable Material olyamide, stainless steel wedge clamp rocess temperature range 4 F to +140 F Overvoltage protection unit OV22/33 (2) OV32/33 (2) field use EN 60715 rail mountable Dimensions 2.8x 1.65x 0.75 inch 2.44x 2.56x 0.7 inch Ingress protection I54 I20 Breakdown voltage 33 V Absorbed energy 600 W / 1 ms Serial resistance 13 Leakage current 10 µa

NIVORESS N-200 2-wire borehole hydrostatic level transmitter for liquids with capacitance ceramic sensor; humidity filter: fixed to breathing cable / Cable N n 2 n n n C Capacitive ceramic sensor / UR T Capacitive ceramic sensor / FE Output N n 2 n n n K Two-wire, 4-20 ma output Level: 4-20mA + Temperature: t100 sensor Version N n n n n n 2 Standard Range N n n 2 n n 1 0-1 m w.h. (0-100 mbar) 2 0-2 m w.h. (0-200 mbar) 3 0-5 m w.h. (0-500 mbar) 4 0-10 m w.h. (0-1.000 mbar) 5 0-20 m w.h. (0-2.000 mbar) Breathing cable length N n n 2 n UR cable FE cable nn = 01-99 : 1-99 m oo = A0-A9 : 100-190 m pp = B0-B9 : 200-290 m Available on request (should be given in the text of the order) High temperature (up to 75 C) version Customised 4-20 ma output calibration NC / NT -200 39

NIVORESS N-400/N-500 2- or 3-wire borehole hydrostatic level transmitter for liquids with stainless steel piezoresistive sensor; humidity filter: fixed to breathing cable iezoresistive stainless steel sensor / UR F iezoresistive stainless steel sensor / FE Z iezoresistive stainless steel sensor, 3/4" BS process connection / UR R iezoresistive stainless steel sensor, 3/4" BS process connection / FE Output K Two-wire, 4-20 ma + HART H * Three-wire, 0-10 VDC output D * Level: 4-20 ma + HART + Temperature: 4-20mA (electronic temp. sensor) Level: 4-20 ma + HART + Temperature: t100 sensor * Ex version not available Version N n n n n n 4 Standard 5 Ex Range N n n n n n 1 0-1 m w.h. (0-100 mbar) 2 0-2 m w.h. (0-200 mbar) 3 0-5 m w.h. (0-500 mbar) 4 0-10 m w.h. (0-1.000 mbar) 5 0-20 m w.h. (0-2.000 mbar) 6 0-50 m w.h. (0-5.000 mbar) 7 0-100 m w.h. (0-10.000 mbar) 8 0-200 m w.h. (0-20.000 mbar) Breathing cable length N n n n n UR cable FE cable nn = 01-99 : 1-99 m oo = A0-A9 : 100-190 m pp = B0-B9 : 200-290 m Available on request (should be given in the text of the order) High temperature (up to 75 C) version (Ex version not available) Customised 4-20 ma output calibration N / NF -400/500 NZ / NR -400/500 N / NF -400/500 + NAW-104 NZ / NR -400/500 + NAZ-103 40 NIV24 NK-431-0 NK-441-0

NIVORESS N-400 2-wire borehole hydrostatic level transmitter for liquids with piezoresistive ceramic sensor; humidity filter: fixed to breathing cable K iezoresistive ceramic sensor / UR / 1.4571 N iezoresistive ceramic sensor / FE / 1.4571 B * iezoresistive ceramic sensor / UR / OM G * iezoresistive ceramic sensor / FE / OM D iezoresistive ceramic sensor, 3/4" BS process connection / UR / 1.4571 H iezoresistive ceramic sensor, 3/4" BS process connection / FE / 1.4571 * Ex version not available Output K Two-wire, 4-20 ma + HART Level: 4-20 ma + HART + Temperature: t100 sensor NKo / NNo-400 NKo / NNo-400 + NAW-104 Version N n n n n n 4 Standard 5 Ex Range N n n n n n 1 0-1 m w.h. (0-100 mbar) 2 0-2 m w.h. (0-200 mbar) 3 0-5 m w.h. (0-500 mbar) 4 0-10 m w.h. (0-1.000 mbar) 5 0-20 m w.h. (0-2.000 mbar) Breathing cable length N n n n n UR cable FE cable nn = 01-99 : 1-99 m oo = A0-A9 : 100-190 m pp = B0-B9 : 200-290 m NDo / NHo-400 NDo / NHo-400 + NAZ-103 Available on request (should be given in the text of the order) High temperature (up to 75 C) version Customised 4-20 ma output calibration NBo / NGo-400 NBo / NGo-400 + NAW-107 41

AccessoriesN NIVORESS N accessories to order A A 1 0 n 0 N Terminal boxes and cable mounting units N A A 1 0 0 1 Terminal box with filter without OV 2 Terminal box with filter with OV-12/33 (only for N_K versions) 5 Sliding sleeve 1 1/2" BS 6 Sliding sleeve 1 1/2" NT N A A 2 0 9 0 Cable mounting wedge clamp Overvoltage protection units O V 2 S L 2 I54 3 I20, DIN rail mounting Sewage adapters N A W 1 0 0 4 Can be mounted instead of the protective cap / 1.4571 7 Can be mounted instead of the protective cap / OM (applicable when there is no risk of tilting) N A Z 1 0 3 0 Sewage adapter (for 3/4" threaded process connection) / 1.4571 Filter NAA-101 / NAA-102 Adapters N A Z 1 0 1 0 3/4" BS / 1/2" BS (1.4571) N A Z 1 0 2 0 3/4" BS / M20x1,5 (1.4571) N A Z 1 0 4 0 1" BS / 1/2" BS (1.4571) N A Z 1 0 5 0 3/4" BS / 1" NT (1.4571) N A Z 1 0 6 0 3/4" BS / 1" BS (1.4571) NAA-105 NAA-209 Accessories to order (see relevant page for details) S A T 3 0 4 0 HART-USB modem S A K 3 0 5 2 HART-USB/RS485 modem S A K 3 0 5 6 HART-USB/RS485 modem / Ex ia OV-22 / 33 OV-32 / 33 42 NIV24 NAA-209-0 OV-22 / 33 OV-32 / 33 NAA-101-0