PURA. Pure Gas Dewpoint Transmitter. Users Guide

Similar documents
EASIDEW TRANSMITTER with Current Source Output

Model PDT Dewpoint Transmitter

GILMONT ACCUCAL FLOWMETERS

AMT-Ex Dewpoint Transmitter

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Preferred Instruments Danbury, CT USA

RD(H)20/25 Pressure-Reducing Regulator User Manual

Instruction Manual. Model DSP-Ex Portable Dewpoint Meter. Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Precision Liquid Settlement Array Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

Additel 761 Automated Pressure Calibrators Selection Guide

DTG - LCD Digital Temperature Gauge USER MANUAL

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

Electro-Pneumatic Converter YT-940 SERIES

RK-IR Sample Draw Aspirator Adapter Operator s Manual

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Flexi-pro Aerosol Delivery System (FADS) Manual

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Eurostyle Terminal Blocks Focus Product Stock List

Design Features. General Description

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

TECHNICAL BULLETIN. Sigma-Aldrich Pure-Pac II System. Technical Bulletin AL-236

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Pre-Calibrated Models

MODEL GT820 OXYGEN SENSOR

Installation, Operation, and Maintenance Manual

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

3.0 Pressure Transmitter Selection

LRS(H)4 Pressure-Reducing Regulator User Manual

Further technical information is available on

High-performance submersible pressure transmitter For level measurement Model LH-10

Rosemount 140/141/142

Installation and Use Manual

Pressure Dump Valve Service Kit for Series 2300 Units

EcoCell Vertical Electrophoresis Unit

with O 2 Controller Instruction Manual

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

Electronic gas volume corrector model DGVC-04

AMS 2710 PCB pressure sensor module with V output

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

Mass Flow Controllers

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Model TX-FM/FN Sensor Head

FTC130 Transmitter. Operating Manual

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

OXYGEN MONITORING SYSTEM OMS

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

GEMS SENSORS & CONTROLS

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

FLAMMABLE GAS SENSOR/TRANSMITTER

Model SDT-Ex Dewpoint Transmitter. Instruction Manual

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Tank Blanketing Pressure Regulators RHPS Series

GasSense NDIR User Manual

WHEATLEY Series 500 Swing Check Valve

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

Halsey Taylor Owners Manual

PC10 Piezoresistive Silicon Pressure Sensor

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA

I/P Transducer Positioner Module

PyroCouple Series Operators Guide

Installation Instructions

HLM-2000-TX Gas Transmitter User Manual

SITRANS P measuring instruments for pressure

1200B2 Series Service Regulators. Instruction Manual

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

Halsey Taylor Owners Manual

Endura AZ40 Sensor assembly High temperature filter assembly kit

3/8" Dr. Air Butterfly Impact Wrench

Expert Hydrostatic Level Transmitters

Model 601CV. Mass Flow Controller. Product Features:

Micro Motion 3098 Gas Specific Gravity Meter

GPR-1500 PPM Oxygen Transmitter

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

TR Electronic Pressure Regulator. User s Manual

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

PRO-50 Instrument Supply Regulator

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

Proportional Relief Valves

JUMO dtrans p30 Pressure Transmitter

Mass Flow Meter (MFM) for gases

Booster Pump PB4-60 Replacement Kits

Transcription:

PURA Pure Gas Dewpoint Transmitter Users Guide Issue January 2003

Page 2 Table of Contents SECTION PAGE 1 Product Overview 3 2 Preparation 3 3 Installation 3 3.1 PURA Premium & OEM Dewpoint Transmitter Installation 3 3.2 PURA Sensor Dewpoint Transmitter Installation 4 3.3 Sensor Electrical Connections (All models) 5 4 Which Gases To Measure 5 5 Maintenance 5 6 Fault Conditions 6 FIGURES 1 View on Rear of Connector Terminal Block 5 2 Pura Premium & PURA OEM 6 3 PURA Sensor 6 APPENDIX 1 Technical Specification 7-8

1. PRODUCT OVERVIEW Page 3 The PURA is a continuous, on-line instrument for the measurement of moisture content in air and other gases over an operating range of -120 C to -40 C dewpoint. The PURA operates as a 4-20 ma transmitter providing a linear analog output to an external control or monitoring device, and is factory set over the range -120 C to -40 C dewpoint. However, the range can be adjusted using the PURA application software to be supplied with this instrument. The Pura is supplied with a certificate of calibration traceable to the National Institute of Standards & Technologies (NIST). 2. PREPARATION Upon receipt, please check that all the items listed under your particular model are present in the packing box: PURA Premium 1) PURA Dewpoint Transmitter (Double bagged in an inert gas filled bag) 2) User Guide 3) Operating Manual 4) Leak check Certificate PURA OEM 1) PURA Dewpoint Transmitter (Single bagged) 2) User Guide 3) Certificate of Calibration 4) Leak check Certificate PURA Sensor 1) PURA Dewpoint Sensor Transmitter (with protective cover) 2) User Guide 3) Certificate of Calibration 3. INSTALLATION The effective operation of the PURA, in a flowing gas environment, relies on the sensor being installed directly into the gas stream or by having a fully representative gas sample directed over the sensor measurement surface. Where possible avoid installing the sensor in a dead or unswept volume. 3.1 PURA Premium and OEM Dewpoint Transmitter Installation only The PURA Premium has been assembled and packaged within a class 100 cleanroom environment. To maintain this level of cleanliness the packaging should only be breached within the same or cleaner environment.

Page 4 Kahn Instruments recommends the use of Swagelok retained gasket assemblies, containing silver plated, stainless steel ¼ VCR gaskets, when connecting the PURA into a gas line. The distance between the inlet and outlet gas connection ports is set at a pitch of 120mm. Install the sealing gasket onto the VCR connections on either the PURA or the connecting gas lines. Insure that the PURA is installed in the gas line with reference to the gas flow direction and the inlet port as indicated on the PURA body. Tighten the female nut firmly finger tight. While holding the PURA stationary with a wrench, tighten the gas line nut 1/8 (one-eighth) of a turn using a second wrench. Repeat this operation on the remaining gas connection port. CAUTION Over tightening the nuts can cause irrecoverable damage to the seals and seatings. 3.2 PURA Sensor Dewpoint Transmitter Installation The PURA Sensor is supplied with an open guard. It is recommended that this guard be removed before installation, since it is not manufactured to the same high level of surface finish as the sensor itself. Its purpose is to protect the measurement element of the sensor during handling. Any use of the sensor with the guard attached will not affect the sensor accuracy but may induce an extended measurement response and provide an opportunity for moisture entrapment points, creating potentially false measurement of the sample. It is recommended that the guard remain on until the sensor is ready to be installed into the point of measurement. Once removed, the guard should be retained and reinstalled as protection, should the sensor be removed from its point of installation e.g. for re-calibration. CAUTION: Care should be used when withdrawing the guard from the sensor to insure that no contact is made with the sensor s measurement surface. Such contact can affect the performance of the sensor. Similarly, when inserting the sensor into the point of measurement, avoid contact with the sensor measurement surface. Any contact with the sensor measurement surface should be avoided. The PURA sensor installation interface is made by use of a ½ VCR sealing face on the body of the sensor. Effective installation can only be completed by mating this sealing face with a similar sealing face and via the use of a metal gasket. Kahn recommends the use of Swagelok retained gasket assemblies containing silver plated, stainless steel ½ VCR gaskets when connecting the PURA into a measurement point. Gaskets are available from Kahn. Install the sealing gasket onto the sensor body of the PURA. Tighten the female nut firmly finger tight. While holding the PURA stationary with a wrench, tighten the connecting nut 1/8 (one-eighth) of a turn using a second wrench.

Page 5 CAUTION: Over tightening can cause irrecoverable damage to the seal and seatings. 3.3 Sensor Electrical Connections (All models) The sensor can be connected via the removable connector. The inner section of the connector can be removed by first withdrawing the central screw and then lifting out the terminal block with a small screwdriver. The sensor should be wired as shown in Fig 1 below. PIN 1 4-20 ma (Source) PIN 3 POW ER (+12V to+24 V) (GND) GROUND (SYSTEM 0V) Fig 1. View on rear of connector terminal block Cable is not supplied as standard, but can be supplied as an option. Standard cable lengths of 3 and 6 feet are available. Longer cable lengths can be supplied on request from Kahn. Alternatively, users can provide their own cable but must insure that it meets the requirements listed under Technical Specifications; see Appendix 1. 4. WHICH GASES TO MEASURE? The PURA is suitable for measurement of the moisture content of a wide variety of gases. In general, if the gas (in conjunction with water vapour) is not corrosive to ceramics or base metals then it will be suitable for measurement by the PURA. 5. MAINTENANCE Routine maintenance of the PURA is confined to regular re-calibration. This work can only be done by exposure of the PURA to sample gases of known moisture content. Calibration services traceable to the National Physical Laboratory (UK), the National Institute of Standards and Technology (USA) are provided by Kahn Instruments. In most applications, annual re-calibration ensures that the stated accuracy of the PURA is maintained. PURA s are fully interchangeable. PURA interchangeability is not affected by cable length; therefore, this method of maintaining calibration can be used for all PURA installations. For applications where the PURA is not required for continuous operation, re-calibration of the PURA can be achieved by return of the complete instrument to Kahn Instruments.

Page 6 45 105 150 1/4" VCR CONNECTIONS 1/2" VCR CONNECTION 20 20 31 28 2 OFF HOLES Ø35 120 M4 X 7 DEEP Fig 2. PURA Premium & PURA OEM 6 27 Fig 3. PURA Sensor CAUTION: For the Pura Premium & Pura OEM models do not remove the sensor from the block. Doing so will invalidate the product warranty. The complete unit should be returned to Kahn Instruments for service / recalibration. 6. FAULT CONDITIONS Symptom Cause Action 1. Current output is 0mA constantly 2. Current output is 4mA constantly 3. Current Output is 20mA constantly 4. Current Output is 23mA constantly Power failure Instrument failure Sensor desiccated Sensor contaminated Gas is wetter than -40 C dp. Sensor contaminated Instrument failure Check power supply to transmitter. Check cable for continuity/damage. Rectify/replace cable. Refer to Kahn or your local representative for repair. Check gas source supply. Replace/Recalibrate sensor Check gas source supply. Replace/Recalibrate sensor. Return to Kahn or your local representative for repair.

Page 7 APPENDIX 1 Technical Specifications Type: Calibration range: Measurement range: Power supply: Output: Dewpoint accuracy: Kahn Ceramic Sensor -100 to -40 C dewpoint -120 to -40 C dewpoint 12 to 28 V DC (25 ma max) 4-20 ma current source over the entire dewpoint range ±1.0 C from -40 to -60 C ±2.0 C from -61 to -100 C ±4.0 C estimated from -101 to -120 C Temperature Ranges: Gas Temperature: -40 to +60 C Operating Environment: -20 to +50 C Storage Temperature: -40 to +75 C Gas wetted surfaces: Gas connection ports: Installation profile: Temperature coefficients: Operating pressure: Flow rate: Traceable certification: 316 Cold Drawn Stainless Steel, 0.25 micron electro-polished PURA Premium & PURA OEM ¼" VCR fixed Male ports PURA Premium & PURA OEM: 120mm between inlet and outlet sealing face PURA Sensor: ½ VCR Male Temperature compensated from 0 C to +40 C 10-9 torr to 24 Mpa 1 to 5 liters/minute -75 to +20 C dewpoint traceable to the National Institute of Standards and Technology. [For dewpoints < -75 C: Direct reference to a fundamental optical hygrometer]. Environmental protection: IP65 Weight: PURA Premium & PURA OEM 450g PURA Sensor 180g

Page 8 Fault conditions: Condition Output Sensor fault 23 ma Under range dewpoint 4 ma Factory programmed Over range dewpoint 20 ma NOTE: The current output range and the fault conditions are user programmable. To enable re-ranging, a software and a Communications Kit are required. Software is available from Kahn Instruments. Sensor Cable (Supplied separately on request): A pair of 7/0.25 mm (22 a.w.g.) stranded tinned copper conductor insulated with polypropylene, twisted together with common tinned copper guard wire, wrapped in polyester tape and together with a second similar pair in a PVC outer sheath Max length 800 meters.