Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Similar documents
Instructions for use Compressed air injector with water trap

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

3 Post Pressure Fit System Owner s Manual

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

User Instruction Manual

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Attention: This operator's manual should be read carefully before using the pistol! ENGLISH

Pressure Relief Valve DHV 718

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

CUT OFF TOOL MODEL: CAT113

RG1200 Service and Repair Manual

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs

SECTION 2 RING MOUNT

INSTRUCTION MANUAL Pressure Relief Device LPT

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

safety Shut-Off Valve HON 721

Pressure relief valve

SSV-Actuator HON 673 (K 1a, K 2a)

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

Instructions Manual. Variable area flowmeter 60 M-1. Series. instrumentation for fluids. Technical Data. C-MI-60M1 Rev.: 0 English Version

AIR INLINE METAL SHEAR

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Gas Pressure Regulator HON 300

CB 350. Spare parts list. Hydraulic concrete buster. CB 350 s/n DEQ Construction Tools GmbH No

OPERATING INSTRUCTIONS

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

PRAHER PLC-MP AQUASTAR MANAUL 2009

GILMONT ACCUCAL FLOWMETERS

Installation and Maintenance Instruction Manual

Pressure relief valve

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Pressure maintenance valve SDV-P / SDV-P-E

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

AIR STAPLER MODEL: CSG1C Part No

Pressure Reducing Valve DMV 750

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

CS150 CAP STAPLER OWNER S MANUAL

DP Spare parts list. Demolition pulverizer. DP 2800 s/n DEQ Construction Tools GmbH No

MEDICAL GAS OUTLETS & PROBES

Declaration of Conformity as per Directive 97/23/EC

BY GREGGERSEN CATA LOG

A18W35_MASE 130_F_EN MANUAL

Instructions for Use Switch Unit AGS 80 D Variant A

Operating instructions - Translation of the original -

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure Fit System - Two Post Version Owner s Manual

Operating and maintenance manual Filter and reducing station Series / 1.0

// ADapters GUIDelines

Service and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13

Operating instructions - Translation of the original -

PILOT PEDAL DRIVE INSTRUCTIONS

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

Pressure Reducing Valve DMV 750 set range: bar

Gas Pressure Regulator HON 300

A17W23_MASE_MUS_EN MANUAL

Copyright MAY, 2008 By Grizzly Industrial, Inc. Warning: No portion of this manual may be reproduced in any shape or form without the written

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Installation and Maintenance Manual. Compact Medical Gas Outlets

3/8" Dr. Air Butterfly Impact Wrench

You have decided to buy an LP 10 E by STEYR SPORTWAFFEN the new dimension of match air pistols!

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

STEYR evo 10 E STEYR evo 10 E Compact

Operating instruction for the quick-change tap holders type:

Pressure relief valve DHV 716 set range: 0,5-10,0 bar


PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

FIREFIGHTING EQUIPMENT

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

AIR/OVER HYDRAULIC JACK 20 TON

Copyright MAY, 2008 By Grizzly Industrial, Inc. Warning: No portion of this manual may be reproduced in any shape or form without the written

4 ANGLE GRINDER MODEL NO: CAT 52 PART

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Installation and Maintenance Instruction Manual

OR-V 41 P BETRIEBSANLEITUNG DEUTSCH ENGLISH FRANÇAIS ITALIANO MODE D'EMPLOI ISTRUZIONI PER L'USO

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

JRGURED Pressure reducing valves

RADROVER REAR RACK INSTALLATION MANUAL

SECTION BUTTERFLY VALVES

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Operating Instructions VETTER Industrial Lifting Bags 8 bar - Type IKV

Transcription:

Instructions for Use Plug connection for medical gas and vacuum acc. to DIN 13260-2 / 2004 DIN EN ISO 9170-1

Table of Contents Page 1. MANUFACTURER S DATA... 3 2. INTRODUCTION... 4 3. APPLICATION... 5 4. OPERATION... 5 4.1 Engaging... 5 4.2 Disengaging or unlocking / park position... 5 4.3 Connector... 6 4.4 Nipple... 6 4.5 Pedestal assembly and mounting set... 6 5. SYSTEM VARIANTS OF OUTLETS... 7 5.1 Pedestal assembly... 7 5.2 Mounting set... 9 5.3 Valve assembly for outlet... 10 5.4 Front plate and swimming ring... 11 5.5 Complete outlets... 12 6. MOUNTING INSTRUCTIONS... 13 6.1 Mounting of outlet in concealed installations... 13 6.2 Mounting of outlet in supply unit... 14 6.3 Internal gas type safeguard... 15 6.4 Inspection valve (sealing plate)... 16 6.5 Valve assembly... 17 7. PUTTING INTO OPERATION... 18 8. CLEANING AND CARE... 18 9. MAINTENANCE... 19 10. SPARE PARTS AND ACCESSORIES... 20 11. TECHNICAL DETAILS (WALL OUTLET)... 23 12. WARRANTY... 24 Seite 2 von 24

1. Manufacturer s Data Product Plug connection for medical gases and vacuum Manufacturer and Sales Office Heyer Aerotech GmbH Nieverner Straße 30 D-56132 Nievern Tel.: +49 (0) 26 03 / 20 04 Fax.: (+49 0) 26 03 / 40 20 E-Mail: office@heyer-aerotech.de Seite 3 von 24

2. Introduction Dear customer! Thank you for choosing a HEYER Aerotech product. HEYER Aerotech appliances are state-of-the-art technology and manufactured according to extremely strict quality standards. You have purchased a highly professional and long-lasting product which is easy to maintain. It is based on the experience of decades and the know-how of powerful medical technology. The plug connection for medical gases complies with all the standards and guidelines currently applicable for the production and operation of the equipment. If, nonetheless, you should find a reason for complaint please do not hesitate to contact our customer service department at any time. Before putting the equipment into operation for the first time, please carefully read these instructions for use and pay special attention to the notes which have been marked additionally. Seite 4 von 24

3. Application Instructions for use Plug connection for medical gas & vacuum The HEYER Aerotech plug connections for medical gas and vacuum are suitable for gas supply units in rooms used for medical purposes and comply with DIN EN ISO 7396-1. The plug connection is available in different designs and mounting variants which allow for its installation in massive walls, light-weight constructions, ceiling supply units, bed supply rails, intensive care supply units etc. As a principle, the Heyer Aerotech plug connections can be installed into any type of ceiling supply units and gas boxes of different manufacturers and in different variants. Description of functions: The HEYER Aerotech plug connection has been designed in such a way that the user is able to establish a safe connection between nipple and outlet. In addition, the design of the plug connection makes it impossible to mix up the different types of gases. 4. Operation 4.1 Engaging When plugging in the device to be connected or when plugging the connector into the outlet it is not necessary to manually operate the outlet. The connector or the device is simply connected by softly plugging it into the wall outlet. The nipple is then kept in the outlet by means of the locking rolls. At the same time the nipple opens the self-closing valve and thus allows the gas or vacuum to flow. 4.2 Disengaging or unlocking / park position By pressing the push button, the nipple will be released from the locking rolls. The self-closing valve is closed in this state, i.e. the gas or vacuum flow is interrupted. By a pull of the connector or of the device the nipple can now be removed. The plug connection has been equipped with a park position which allows the nipple to stay locked in the outlet without releasing gas. Seite 5 von 24

4.3 Connector The connector is made up of a medium-specific coded nipple and the colour-coded handle with the designation of the gas type. The hose is used to engage mobile medical apparatuses to outlets. 4.4 Nipple A nipple is that part of a medical apparatus or of a connector which is engaged into the outlet. 4.5 Pedestal assembly and mounting set The pedestal assembly is that part of the outlet which is connected to the gas supply network. The internal gas type safeguard (gas type safeguard disc) is firmly connected with the pedestal assembly. The mounting set includes all the holders and fastening elements which are required for connecting the valve assembly. When mounting the valve assembly, the inspection valve is integrated into the pedestal assembly and is thus connected with the pedestal assembly. Seite 6 von 24

5. System variants of outlets 5.1 Pedestal assembly Valve pedestal, DIN, surface/concealed installation, installation dimension = 65mm, height = 27mm Article no.: 5433055 1 2 Valve pedestal, height = 27mm, Cu-pipe Ø 8 mm Article no.: 1) 5433064 2) 5433096 3) 1441855 4) 5433095 4 3 1 2 3 Valve pedestal, height = 27mm, Cu-pipe Ø 8 mm Article no.: 1) 5433059 2) 5433052 3) 5433058 Seite 7 von 24

1 2 Valve pedestal, height = 22mm, Cu-pipe Ø 8 mm Article no.: 1) 5433097 2) 5433098 3) 5433063 4) 5433099 4 3 1 2 3 4 Valve pedestal, height = 19mm, Cu-pipe Ø 8 mm Article no.: 1) 5433091 2) 5433092 3) 5433093 4) 5433094 5) 5433090 5 1 2 3 5 Valve pedestal, height = 27mm, hose adapter Article no.: 1) 5433039 2) 5433041 3) 5433044 4) 5433038 5) 5433040 4 Seite 8 von 24

1 2 Valve pedestal, height = 22mm, hose adapter Article no.: 1) 5433043 2) 5433042 5.2 Mounting set Mounting set for outlet concealed installation Article no.: 5433065 Consisting of: threaded pin retainer for O-ring O-ring sealing plate Mounting set for supply units Article no.: 5433066 Consisting of: internal gas type safeguard (gas type safeguard disc) sealing plate tooth washer with cylinder bolt retainer for O-ring O-ring 21x2 mm (Art. no.: 049-3274) O-ring 14,6x2,6 mm (Art. no.: 049-3182) Nieten Seite 9 von 24

5.3 Valve assembly for outlet For valve pedestal, height = 27 mm Art. no. O 2 Air N 2 O Vac CO 2 ISO 7434000 7434010 7434020 7434030 7434031 Neutral 6434000 6434010 6434020 6434030 6434031 For valve pedestal, height = 22 mm Art. no. O 2 Air N 2 O Vac CO 2 ISO 7434060 7434061 7434062 7434063 7434064 Neutral 6434060 6434061 6434062 6434063 6434064 For valve pedestal, height = 19 mm Art. no. O 2 Air N 2 O Vac CO 2 ISO 7434032 7434034 7434033 7434035 7434037 Neutral 6434032 6434034 6434033 6434035 6434037 Seite 10 von 24

5.4 Front plate and swimming ring Front plate, concealed installations Article no.: 0211200 Swimming ring for installation in supply units Article no.: 0451845 Seite 11 von 24

5.5 Complete outlets Outlet complete for surface installation Art. no.: O 2 Air N 2 O Vac CO 2 ISO 7434300 7434310 7434320 7434330 7434331 Neutral 6434300 6434310 6434320 6434330 6434331 For more variants of our complete outlets please refer to our website: www.heyer-aerotech.de Seite 12 von 24

6. Mounting Instructions 6.1 Mounting of outlet in concealed installations 4 1 2 3 5 6 Remove protective cover from box for concealed installation ( 1) Use wrench (Art. no. 022-2190) to remove sealing plug in box for concealed installation ( 1) Insert the sealing plate ( 2) with the flat side to the back 7 Do NOT install a sealing plate with vacuum Screw the threaded pins ( 3) into the valve case Mount the O-ring ( 4) onto the retainer ( 5) Use the wrench (Art. no. 022-2190) to screw the retainer with O-ring Fasten the valve assembly ( 6) Mount the front plate ( 7) Seite 13 von 24

6.2 Mounting of outlet in supply unit 2 1 3 5 2 4 6 Use the two rivets ( 2) to fasten the gas type safeguard disc ( 1) Insert the sealing plate ( 3) with the flat side to the back Do NOT install a sealing plate with vacuum Place the O-ring 21x2 mm ( 4) into the valve pedestal Place the O-ring 14,6x2,6 mm ( 5) into the retainer for the O-ring ( 6) Use the wrench (Art.-Nr.: 022-2190) to screw the retainer with the O-ring Mount the valve assembly with the two tooth washers and the cylinder bolts ( 7) Seite 14 von 24

6.3 Internal gas type safeguard The gas type safeguard is firmly connected with the pedestal and cannot be separated from it. It guarantees that only pedestal assemblies and valve assemblies of the same gas type can be put together. Coding of the internal gas type safeguard is carried out by breaking off the gas type-specific code pins. Before coding Coding O 2 Coding Air Coding N 2 O Coding Vac Coding CO 2 Seite 15 von 24

6.4 Inspection valve (sealing plate) The inspection valve is mounted into the pedestal assembly. It allows for dismantling the valve assembly and for changing all wearing parts and sealing elements with operating pressure. Sealing plate Do NOT install sealing plates with vacuum outlets! Seite 16 von 24

6.5 Valve assembly The valve assembly may be separated from the pedestal assembly. It includes, among others, the spline end, the exterior gas type safeguard in the valve case and the self-locking valve. In addition, it houses the locking elements for the nipple. 1 2 3 4 5 6 7 8 98 10 14 13 12 11 1 Foil sign 2 Valve case 3 Push button 4 Locking pin 5 O-ring 9,92 x 2,65 mm 6 O-ring 17 x 2 mm 7 O-ring 6,3 x 2,4 mm 8 Valve cone 9 Spline end 10 Pressure spring for valve cone 11 Pressure spring for push button 12 Clamp spring 13 Spacer ring 14 Retaining ring Seite 17 von 24

7. Putting into Operation Before putting the outlet (or medical supply units with outlets installed in them) into operation, it is absolutely indispensable to carry out a gas type test. This gas type test has to be carried out by the assembling firm and the user. The results have to be recorded and to be signed by both of them. This record is a document! At the same time, i.e. with the gas type test, the locking and unlocking functions of the nipple in the outlet have to be checked. The gas type test has to be carried out with utmost care and attention! Mixing up the gas types (e.g. O 2 with N 2 O) may lead to fatal accidents! 8. Cleaning and Care Both outlet and connector have to be cleaned with non-alcoholic and solvent-free detergents usual in trade. Please make sure that no liquids enter into the individual construction elements. Seite 18 von 24

9. Maintenance In order to prolong the service life of the HEYER Aerotech outlets we recommend carrying out the following maintenance works in regular intervals. Check tightness and functionality of the equipment in 6-month intervals. If necessary, replace faulty parts. Only use genuine parts. For maintenance works, we recommend concluding a contract with Heyer Aerotech directly or with a customer service authorized by HEYER Aerotech. In this context, please also observe the stipulations laid down in DIN EN ISO 7396-1. Note: Maintenance works on the HEYER Aerotech outlets can be carried out at any time by dismantling the complete valve assembly. This is also possible with operational pressure, i.e. it is not necessary to interrupt the medical gas supply. Other advantages of the HEYER Aerotech outlet: The valve assembly has been designed as one unit, i.e. it can also be dismantled as a complete unit! We exclusively use long-lasting and resistant materials for our production. The valve case is completely made of metal. Seite 19 von 24

10. Spare Parts and Accessories Sealing set for outlet, Art. no.: 543-3071 The following O-rings are included in the sealing set. O-ring 14.6 x 2.6 O-ring 9.92 x 2.65 mm O-ring 17 x 2 mm O-ring 6.3 x 2.4 mm Seite 20 von 24

Base sheet for fastening concealed boxes in cavity walls 2 1) 00009988 Base sheet, type A, 1-fold, concealed, interior/25 mm front 2) 00009987 Base sheet, type B, 1-fold, concealed, interior/125mm back 1 Model applications Type A Type B Seite 21 von 24

Socket wrench for mounting set, valve pedestal Article no.: 0222190 Holding key for valve assembly Article no.: 4100082 For more accessories please refer to our website: www.heyer-aerotech.de Seite 22 von 24

11. Technical Details (wall outlet) Operational pressure gases acc. to DIN 13260 Part 2 and DIN EN ISO7396-1 Operational pressure vacuum acc. to DIN 13260 Part 2 and DIN EN ISO 7396-1 Mounting depth wall outlet Plaster compensation (series) Plaster compensation (special length) Push button Locking elements Valve case Pedestal Inspection valve Gas-carrying parts gas outlet Nipple Handles, plugs standard Handles, plugs optional : 5 bar ± 0.5 bar : -0.7 bar ±0.2 bar : appr. 62 mm : firmly installed, appr. 10mm : upon request : plastic, black : plastic, with colour code and gas type identification : stainless steel, metal : metal, nickel-plated and chromed : metal : metal : metal : stainless steel : metal, with colour code and gas type identification impact-resistant and firmly welded together : plastic Seite 23 von 24

12. Warranty Instructions for use Plug connection for medical gas & vacuum The warranty period for the medical gas outlet systems by HEYER Aerotech is 12 months starting from the date of sale in accordance with the following conditions: During the period of warranty, we will eliminate, free of charge, any damage or failures of the equipment caused by verifiable faults in production or in the material, provided that these failures have been reported without delay after detection. Deviating from this, the warranty for engines of any type, compressors, electric switching devices, semiconductor elements, electric displays and measuring equipment is six months. The elimination of faults, free of charge, will be carried out in our factory. This warranty is not applicable to fragile parts made of glass, for example, or consumable and wearing parts. In the case of a guarantee, the decision of whether to repair or exchange the equipment will be at our own option. Cases of guarantee will neither extend the period of warranty nor will they represent the start of a new period of warranty. Spare parts which are installed will not be subject to an individual period of warranty. Any damage caused by improper use, faulty operation, mechanical damage or non-observance of the instructions for use as well as any damage caused by force majeure or any other unusual environmental conditions will not be covered by the warranty. The warranty claim will expire when interventions, changes or repairs of the equipment have been carried out by people who have not been authorised by us to do so or when the equipment has been used with additional accessories or spare parts of strange origin. Further claims as well as any so-called consequential damage will be excluded as long as liability is not required by law. Equipment may be subject to technical changes without notice! Rev. 2.2 as per 01 June 2010 Seite 24 von 24