Electrically Operated Pressure-Relief Cartridge, Size 10

Similar documents
Inverse Proportional Pressure-Relief Cartridge, Size 10

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4

Proportional Throttle Cartridges, Size 16

3-Way Pressure-Reducing Cartridge, Size 2 4

Pressure-Relief Cartridge Valve, Size 4

Cooler-Bypass Thermostat Valve, Size 16

Double Pilot Operated Cartridge Check Valve, Size 8

Leak-Free Load-Control Valve SAE ½ psi flange

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Leak free Pipe Rupture Valve for Excavators

Leak-Free Load-Control Valve, Size 20

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Safety and Shut-off Block SAF/DSV

3-Way Safety Block DSV

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Pressure reducing valve, direct operated

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PRESSURE COMPENSATORS TECNORD

The Size 16 Product Range

Safety and Shut-off Block SAF/DSV

Pressure reducing valve, pilot operated

Pressure reducing valve, direct operated

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

PRESSURE SEQUENCE VALVE TYPE UZK

Check valve hydraulically pilot operated

Pressure reducing valve, pilot operated, Model 3DR

Cover headline. Cover subheadline. Check Valves

SDM to 8 sections monoblock valve D1WWDA02A

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Safety and Shut-off Block SAF/DSV

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

SOLENOID VALVES AND PNEUMATIC VALVES

Hand & mechanical directional valves

4/2 way Pneumatic Solenoid Valve

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

D62 - D63 Directional Control Valve l/min

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Fixed Displacement Plug-In Motor A2FE

Pump safety block. Type DBA, DBAW, DBAE(E) Features. Contents. RE Edition: Replaces: 11.10

Proportional Directional Valve System

Intrinsically safe solenoid valves on/off controls - ATEX certification

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

SATURNSERIES INTERCHANGE > ISO (for the couplings)

VSD03M DIRECTIONAL CONTROL VALVES

Directional Valves. Hydraulic Operated Directional Valves

Pressure relief valve, direct operated Type DBD

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

SPCH/ Blowing block

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Monoblock Directional Control Valve RMB 202

Directional Controls

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

Monoblock directional control valves ML - Directional control valve

Pressure Dump Valve Service Kit for Series 2300 Units

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Size 10 (D05) p max 320 bar (4600 PSI) Technical Features. Technical Data. Port dimensions ZB10A(B) SMT_0019 ZB K -

SPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at:

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

DNS. Monoblock directional control valves DNS - Directional control valve

Pressure relief valve, direct operated

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Fixed Displacement Motor A4FM

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Pressure reducing/relief valve, pilot operated type UZCP10

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Directional Controls

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

Solenoid valves VZWF, force pilot operated

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

Pilot valves for pilot operated servo valves

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

Pressure relief valve, direct operated

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

180 Series Rotary Shear Directional Control Valve

PVQ 13 A2 R SE 1 S 20 C-11 D

Motion Controls Valve locator

Transcription:

Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description Series WUVPOC-2 and WUVPLC-2 valves are size 1 electrically operated pressure relief cartridges with an M24x1.5 mounting thread. They have a seated pilot stage and a spool-type main stage. Using the external pressure adjustment, the higher pressure p1 (relief setting) and the lower pressure p2 (a secondary pressure, or the unloaded pressure) can be varied smoothly and independently of one another without opening the hydraulic envelope, and either pressure can be selected. The OC model is mainly used for bypass circuits that can be unloaded with low p values (ON / OFF). The lower p values result in less heating of the oil and thus lower energy costs for the user. The LC model 2 Symbol Compact construction for cavity type DD M24x1.5 to Bucher standard Bypass circuit ON / OFF 2-pressure switching HI / LO Low unloaded bypass pressure with OC model to 1 l/min With remote-control port Z High pressure wet-armature solenoids The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope Various plug-connector systems and voltages are available ll exposed parts with zinc-nickel plating Can be fitted in a line-mounting body is mainly used for 2-pressure circuits (HI / LO). Using the remote-control port Z, these valves can also be remotely controlled or unloaded by means of external pressure relief valves or directional valves. When the pilot stage is active (pressure relief function), pilot oil is drained internally to port B. ny residual- or surge-pressure in port B (Tank) is therefore additive to the valve setting. ll external parts of the cartridge are zinc-nickel plated to DIN 5 979 and are thus suitable for use in the harshest operating environments. If you intend to manufacture your own cavities or are designing a line-mounting installation, please refer to the section Related data sheets. B Z 3 Technical data General characteristics Designation Description, value, unit pressure-relief cartridge valve Design spool-type design, seated pilot, with remote control port Z, electrically operated Mounting method Size screw-in cartridge M24 x 1.5 nominal size 1, cavity type DD to Bucher standard Weight.52 kg (1.15 lb) Mounting attitude unrestricted mbient temperature range -25 C +5 C (- F +122 F) Reference: 4-P-29111-EN-2 Issue: 3.218 1/7

Hydraulic characteristics Description, value, unit Maximum operating pressure 1) bar (5 psi) Pressure adjustment range: bar (5 psi) 25 bar (36 psi) 16 bar (23 psi) 1 bar (14 psi) 4 bar ( 57 psi) Maximum flow rate 14 l/min (37 gpm) (at > 1 l/min, "LC" model recommended by the manufacturer) Flow direction B, see symbols Hydraulic fluid HL and HLP mineral oil to DIN 51 524; for other fluids, please contact BUCHER Hydraulic fluid temperature range -25 C +8 C (- F +176 F) Viscosity range Minimum fluid cleanliness Cleanliness class to ISO 446 : 1999 1 5 mm 2 /s (cst), recommended 15...25 mm 2 /s (cst) class 2/18/15 Electrical characteristics Supply voltage Supply voltage tolerance Nominal power consumption Relative duty cycle Protection class to ISO 2 653 / EN 6 529 Electrical connection Description, value, unit 12 V DC, 24 V DC / 115 V C, 23 V C (5 6 Hz) ± 1 % V DC = 27 W V C = 25 W 1 % IP 65 / IP 67 / IP 69K, see Ordering code (with appropriate mating connector and proper fitting and sealing) DIN EN 17531-83, 3-pin 2 P+E (standard) for other connectors, see Ordering code TTENTION! 1) ny residual- or surge-pressure in port B (tank pressure) is additive to the pressure setting in port. 2/7 4-P-29111-EN-2/3.218

4 Performance graphs measured with oil viscosity 33 mm 2 /s (cst) bypass circuit (ON/OFF) WUVPOC- p = f (Q) Pressure-drop characteristic ( bar) (5) 3 (43) 25 (36) 2 (29) 15 (21) 1 (14) 5 (7) P497.ai p = f (Q) Pressure-drop characteristic (25 bar) (5) 3 (43) 25 (36) 2 (29) 15 (21) 1 (14) 5 (7) P496.ai 7 15 14 7 15 14 p = f (Q) Pressure-drop characteristic (16 bar) 25 (36) 2 (29) 15 (21) 1 (14) 5 (7) P495.ai p = f (Q) Pressure-drop characteristic (1 bar) 14 (2) 12 (17) 1 (14) 8 (115) 6 (86) 4 (57) 2 (285) P494.ai 7 15 14 7 15 14 p = f (Q) Pressure-drop characteristic (4 bar) 7 (1) 6 (86) 5 (7) 4 (57) 3 (43) 2 (285) 1 (14) P493.ai application limit / minimum bypass pressure 16 (23) 12 (17) 8 (115) 4 (6) P51.ai 7 15 14 7 15 14 p2 min. = application limit / minimum bypass pressure 4-P-29111-EN-2/3.218 3/7

2-pressure switching (HI/LO) WUVPLC- p = f (Q) Pressure-drop characteristic ( bar) (5) 3 (43) 25 (36) 2 (29) 15 (21) 1 (14) 5 (7) P492.ai p = f (Q) Pressure-drop characteristic (25 bar) (5) 3 (43) 25 (36) 2 (29) 15 (21) 1 (14) 5 (7) P491.ai 7 15 14 7 15 14 p = f (Q) Pressure-drop characteristic (16 bar) 25 (36) 2 (29) 15 (21) 1 (14) 5 (7) P49.ai p = f (Q) Pressure-drop characteristic (1 bar) 14 (2) 12 (17) 1 (14) 8 (115) 6 (86) 4 (57) 2 (285) P489.ai 7 15 14 7 15 14 p = f (Q) Pressure-drop characteristic (4 bar) 6 (86) 5 (7) 4 (57) 3 (43) P488.ai application limit / minimum bypass pressure 16 (23) 12 (17) 8 (115) P52.ai 2 (285) 1 (14) 4 (6) 7 15 14 7 15 14 p2 min. = application limit / minimum bypass pressure 4/7 4-P-29111-EN-2/3.218

5 Dimensions & sectional view Type WUVPOC M = 2.7 [Nm] ± 1% (2 ft lbs ±1 %) 54.5 (2.15) 43.2 (1.7) Tightening torque M 2) ± 1 % Cavity type When fitted in steel When fitted in aluminium DD 65 [Nm] (5 [ft-lbs]) 5 [Nm] ( [ft-lbs]) 32.5 (1.28) 3 M = 6,5 [Nm] 1% (4.5 ft lbs ± 1 %) Seal kit NBR no. DS-261-N 3) Item Qty. Description 1 1 Seal ring 22.1 / 16.5 x 2.5 154.85 (6.1) 48.6 16.25 (1.91) (4.18) 53 (2.9) 3 2 1 36 Z B 27 M = 2) M24x1,5 2 2 O-ring no. 2 21.95 x 1.78 N9 3 2 O-ring 16. x 2. V83 IMPORTNT! Type WUVPLC 47.6 (1.4) Z 3) Seal kit with FKM (Viton) seals, no. DS-261-V 6 Installation information IMPORTNT! When fitting the cartridges, use the specified tightening torque. TTENTION! Only qualified personnel with mechanical skills may carry out any maintenance work. Generally, the only work that should ever be undertaken is to check, and possibly replace, the seals. When changing seals, oil or grease the new seals thoroughly before fitting them. 4-P-29111-EN-2/3.218 5/7

7 Pressure adjustment (pressure p1 must be set first, followed by pressure p2) Nr. Setting the higher pressure p1 on series WUVPOC / WUVPLC as the higher working pressure with solenoid energised: Nr. Setting the lower pressure p2 (emergency pressure setting) on series WUVPOC / WUVPLC (a second pressure or alternatively, unload) with solenoid de-energised: 1) Slacken and remove cap nut item ( /F). 2) Slacken lock nut item D ( /F) approx. ½ turn. 3) With pump running and with the solenoid energised, use the two flats (7 /F) to turn adjusting screw item B until the required pressure is set in port. 4) Hold the adjusting screw item B using the 7 /F flats while tightening the lock nut item D ( /F). 1) Slacken and remove cap nut item ( /F). 2) With pump running and with the solenoid de-energised, use the adjusting screw item C (2.5 /F hex. socket) to set the pressure p2 in port. 3) Refit and tighten the cap nut item. (p2 min.: 2 15 bar for WUVPOC, dependent on flow). (p2 min.: 4 1 bar for WUVPLC, dependent on flow). 5) Refit and tighten the cap nut item. B 7 (.28) M = 6.5 [Nm] ± 1% (4.5 ft lbs ±1 %) D M = 6.5 [Nm] ± 1% (4.5 ft lbs ± 1 %) M = 6.5 [Nm] ±1% (4.5 ft lbs ± 1 %) C 2.5 (.1) TTENTION! When setting pressure p1, adjusting screw item B must not be overtightened as this can damage the shoulder which limits the maximum pressure setting. s soon as a definite end-stop can be felt, do not turn any further. Example showing the adjustable pressures p1 and p2: p [bar] P498.ai F H E G Zeit [t] H = when item C is unscrewed until flush E, G = pressure p1; as set with item B, solenoid energised F = pressure p2, min. as H, max. as E and G, adjustable at item C, solenoid de-energised Type WUVPLC The relief pressure p1 is set as the higher working pressure (E) (solenoid energised) p2 as the lower working pressure (F) (solenoid de-energised) Type WUVPOC The relief pressure p1 is set as the higher working pressure (G) (solenoid energised) p2 as the lowest unloaded bypass pressure (H) = item C flush (solenoid de-energised) 6/7 4-P-29111-EN-2/3.218

8 Ordering code Ex. WU V P O C - 2 D O - - 1 _ - 1 24 D _ WU = electr. operated pressure-relief valve V = seated two-stage P = cartridge design O = for unloading duty (ON/OFF) L = for two-pressure duty (HI/LO) C... Q = standard model per relevant data sheet Y... R = special features - please consult BUCHER 2 = pressure function 2 (with remote control port Z) D = cavity type DD O = normally open = pressure range 1 bar 25 = pressure range 1 25 bar 16 = pressure range 1 16 bar 1 = pressure range 1 1 bar 4 = pressure range 1 4 bar 1 = nominal size 1 (blank) = NBR (Nitrile) seals (standard) V = FKM (Viton) seals (special seals - please contact BUCHER) 1... 9 = design stage (omit when ordering new units)... = voltage e.g. 24 (24 V) D = current DC = current C (blank) = DIN EN 17531-83 connection with mating plug (standard, IP 65) M1 = DIN EN 17531-83 connection without mating plug C = Kostal plug connection (IP 65) JT = Junior Timer radial plug connection (with protection diode, IP65) IT = Junior Timer axial plug connection (with protection diode, IP65) D = Deutsch plug connection DT4-2P (IP 67/69K) mating plug not supplied DT = Deutsch plug connection DT4-2P (with protection diode, IP 67/69K) S = MP Superseal 1.5 (IP67) / Metri-Pack 15 (IP65) plug connection F = flying leads (5 mm) 9 Related data sheets Reference (Old no.) Description 4-P-411 4-P-6121 4-P-1211 4-P-74111 The form-tool hire programme Cavity type DD Coils for screw-in cartridge valves Line- and manifold-mounting body, type DDY-12 (G 1/2 ) info.ch@bucherhydraulics.com www.bucherhydraulics.com 218 by Bucher Hydraulics G Frutigen, CH-3714 Frutigen ll rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 43..3..32.3 4-P-29111-EN-2/3.218 7/7