BSS 2 Bottle Sampling System. Instruction manual Version 1.8

Similar documents
Budget Range Operators Handbook

BS ml Bottle Sampling Unit

PRESSURISED PAINT CONTAINER

Operation Manual Air Saver Unit ASV5000 Series

Safety instructions and operating manual

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

STAGE, STADIUM & X-TREME SHOT.

User Manual. Quantos Automated Dosing Liquid Module

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

Pressure maintenance valve SDV-P / SDV-P-E

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Instructions for use Compressed air injector with water trap

Installation, operating and maintenance Instructions for Seemag bypass level indicator

256 Pneumatic Pressure Indicator

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

VERTICAL AIR COMPRESSORS

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Instruction Manual Contact Pressure Vacuum Gauge

Flamco Flamco-Fill STA Flamco-Fill STM

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

VERTICAL AIR COMPRESSORS

Two-stage valve type NE

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

SILENTAIRE TECHNOLOGY

Masoneilan* 78 Model Air Filter Regulator

Float Operated Level Controllers

Operating Manual FSV, FSÖV, SSVF

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Siphon vessel / Priming aid

Series IRV1000/2000/3000

INSTALLATION & MAINTENANCE INSTRUCTION

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Installation Instructions for NP100 Series Nitrogen Control Panels

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

SILENTAIRE TECHNOLOGY

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Operating and maintenance manual Filter and reducing station Series / 1.0

Inverse Prop. Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Pressure Automated Calibration Equipment

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Operating manual for Material pressure tanks Vol./1 and Vol./2

Code AWC20HP Air Compressor

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

Installation and commissioning instructions 255 series and 256 series

MD R a n g e O p e r a t o r s H a n d b o o k

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Temperature Controllers

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

The Univentor 1250 Anaesthesia Unit

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

WXG-4 Manual Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

User Instruction Manual

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

for the of and the EM55-1

Pneumatic Service Unit

Preliminary filter Precision measurement chamber Flow meter Instruction manual

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Operating Instruction English. Revision A Date author NH This operating instruction is not subject to updating. Airgun

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

PH01 Perfusion Cannula Manual

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

ML3M Monnier Miniature Compressed Air Lubricator

Inverse Proportional Pressure-Relief Cart., Size 2 4

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Airtester HP for compressed air according to EN 12021

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Pressure Relief Valve DHV 718

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

Inverse Proportional Pressure-Relief Cart., Size 2 4

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

OPERATING INSTRUCTIONS

200L BELT DRIVEN AIR COMPRESSOR

DMX 3 - DMX 3 MF INSTALLATION OPERATION MAINTENANCE. Your distributor : TECHNICAL INSTRUCTIONS (e) Revision

AREA VALVE SERVICE UNITS

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Ritter AquaBottleSystem

Transcription:

BSS 2 Bottle Sampling System Instruction manual Version 1.8 Serial-No.:... Version-/Rev.-Date : 12.06.2012

Contents 1. General... 3 2. Safety Instructions... 4 3. Extent of Delivery... 5 4. Switch Panel... 6 5. Bottle Sampling... 7 5.1. Reservoir... 7 5.2. Sampling... 7 6. Commissioning... 8 6.1. Power supply... 8 6.2. Compressed Air Supply... 9 6.2.1. Operation with the Compressor from INTERNORMEN-electronics... 10 6.2.2. Operation with Existing Compressed Air Supply... 11 6.3. Connection to CCS 1 / CCS 2... 12 7. Before the Analysis... 13 7.1. Conditioning of the Sample... 14 8. Analysis of sample... 14 8.1. Degassing... 14 8.2. Sample Feed... 17 9. Cleaning and Maintenance... 19 10. Technical Data... 20 10.1. Connections... 20 10.1.1. Electrical... 20 10.1.2. Pneumatic... 20 2

1. General Dear Customer We congratulate you on buying the INTERNORMEN-electronics Bottle Sampling System BSS 2. Before commissioning please read this manual carefully to prevent damages to the BSS 2. You have purchased a product which is technically up-to-date and which enables you to perform a particle count in lab quality, at any points of your plant where an onlineanalysis is not possible. The sampling and the output of results only take a few minutes. In general an online-measurement is to be preferred rather than a bottle sample analysis. The process from sampling to particle counting involves many possibilities of mistakes. Therefore this kind of analysis should be carried out only by trained personal. 3

2. Safety Instructions To prevent accidents it is important to keep strictly to the manual during the operation of the BSS 2. Never try to open the pressure chamber, when the system pressure varies from the ambient air pressure. Never try to pressurise the chamber before being sure that it is tightly closed (see the lighting diode!) Never use damaged or defective components (threaded joints, hoses, connectors etc.)! A damaged pressure vessel (scratches in the glass, bent housing etc.) must not be used. Never open the BSS 2 housing! In case of any irregularities concerning the function of the BSS 2 please immediately contact your nearest INTERNORMEN Technology GmbH in Altlußheim representative. 4

3. Components of BSS 2 The BSS 2 includes : - Case [1] - Instrument base with integrated service unit [2] - Pressure vessel [3] - Power supply unit [4] - Connector for pneumatics [5] - High pressure hose with mini-measuring connection M 16x2 [6] - Compressor [7] (optional) - Spiral hose [8] (optional) 1 4 2 5 3 8 7 6 Illustration 1 5

4. Switch Panel B1 B3 B6 B5 B7 B2 B4 Illustration 2 B1 Vacuum + pressure gauge B2 Regulator (pressure + vacuum) B3 Switch VENT / WORK B4 Switch PRESSURE / VACUUM B5 Switch OPEN / CLOSE B6 Green light emitting diode OPEN B7 Yellow light emitting diode CLOSE 6

5. Bottle Sampling 5.1. Reservoir Before sampling make sure that the reservoir to be used can be put into the pressure chamber of the BSS 2. To guarantee reliable results of measurement you should only use reservoirs whose cleanliness according to ISO 3722 is proved. You can buy them directly from INTERNORMEN Technology GmbH (two sample bottle set, Best. Nr. 313427). These glasses should be used only once. 5.2. Sampling The bottle sampling requires a very careful handling. First flush the sampling point for a few seconds. Open the sample reservoir just directly before taking the sample, and close it immediately afterwards. Only this way the ambient influences do not impact your measuring results. Label your samples carefully. Note: Sampling point Date and time of sampling Sampler (name, first name) Special notes, if applicable This is important for samplings at different plants, respectively different points of the plant to help prevent any unclearness. 7

6. Commissioning 6.1. Power supply For the operation of the BSS 2 you should only use the plug-in power supply supplied by INTERNORMEN-electronics, which is included in the system. Make sure that this power supply unit is set to the required output voltage of 12 V DC. (Illustration 3). Illustration 3 Put the plug of the power supply unit into the current outlet (230 V~ 50 Hz) and the connection cable into the socket of the BSS 2 (Illustration 4) on the backside of the device. The actual unit might vary depending on the respective country's voltage. 8

Illustration 4 When correctly connected, one of the light emitting diodes OPEN respectively CLOSE should light up after a few seconds. Turn the switch VENT / WORK to the direction VENT, if it is in WORK. 6.2. Compressed Air Supply In addition to the electric connection, the BSS 2 of INTERNORMEN-electronics also requires an external compressed air supply. This is provided either by an existing compressed air piping or the compressor optionally available. 9

6.2.1. Operation with the Compressor from INTERNORMEN-electronics Instructions for the handling of the compressor are given in the enclosed manual. Connect the BSS 2 with the compressor. For this use the spiral hose (Pos. 8, Illustration 1) which is optionally available. Put the hose plug into the coupler of the compressor. (Illustration 5). Illustration 5 Now put the other end (coupler) into the quick connect plug at the backside of the BSS 2 (Illustration 6). The coupler is locked, when you hear a clicking noise while putting into one another. Illustration 6 To release the plug connectors, pull back the locking ring of the closing coupler. Before releasing make sure that the system is not under pressure. 10

Integrated service unit The serialize inserted service unit prevents the entry of dirt and humidity into the BSS 2. To empty the container over knurled screw during accumulation of liquid. 6.2.2. Operating with Existing Compressed Air Supply Note: Take care that the parameters required concerning the air volume flow as well as the pressure are strictly kept! Any divergences might cause malfunctions or damages of the BSS 2. The filter regulator reducer which is optionally available should be used. Connect the BSS 2 to the pressure air supply. For this please use the optional attached plug-in connection to be connected with the device. This plug-in connection has an internal screw thread G 1/4 for the hose. Please make sure a firm seat and sealing between the hose and connector. Now slip the connection cap over the plug at the backside of the BSS 2 (Illustration 7). To release the plug connectors, pull back the locking ring of the closing coupler. Before releasing make sure that the system is not under pressure. Illustration 7 11

Integrated service unit The serialize inserted service unit prevents the entry of dirt and humidity into the BSS 2. To empty the container over knurled screw during accumulation of liquid. 6.3. Connection to CCS 1 / CCS 2 Connect the BSS 2 to the contamination control system by means of the pressure hose (6, Illustration 1) included in the BSS 2. First remove the screw cap of the minimeasuring connection at the top of the pressure vessel (Illustration 8). Now you can mount the hose. The same way of connection applies to the CCS 1 as well as the CCS 2. Illustration 8 Note: Make sure a firm (hand-tight) fixing of the screw couplings to the high pressure hose. A proper sealing is needed for correct results of the analysis! 12

7. Before the Analysis After following the instructions you are ready to operate the BSS 2. Make sure that you have sufficient air supply and pressure (max. 10 bar). Turn the compressor on (if operated by compressor), respectively open the feeding main to the BSS 2 (existing compressed air supply). Set the pressure control valve to a rate between 6,0 and 6,5 bar. A different pressure rate might cause malfunctions or damages to the BSS 2. Turn the switch OPEN / CLOSE to the position OPEN. When the diode OPEN (green) lights up, the pressure chamber lock is released. Now you can remove the pressure vessel. Make sure that an O-ring (90x2,5) is inside the locking device (Illustration 9). Illustration 9 13

7.1. Conditioning of the Sample Before putting the bottle into the BSS 2 for examination, homogenize thoroughly and ½ - 1 minute in the ultrasonic bath place. For exact measuring results an equal distribution of the particles is important. The following shakingprocedure should take about two minutes, dependent on the fluid viscosity, contamination and time interval between sampling and analysis. The vibration time depends directly on the fluid viscosity. < ISO-VG-32 2 min ISO-VG-46... 100 3... 4 min > ISO-VG-100 5... 10 min (additional warming-up is indicated) 8. Analysis of sample Instructions for the operation of the CCS1, respectively the CCS2 can be taken from their manuals. Immediately after termination of the sample conditioning the analysis should be done. 8.1. Degassing Place the sample on the cover plate of the pressure chamber at the topside of the device. Please make sure once again that the O-ring is in proper position. Place the pressure vessel over the sample. Be aware of the correct position, i.e. it has to have slipped completely downwards. Now you can turn the switch OPEN / CLOSE to the position CLOSE (Illustration 12, 1). Wait until after a few seconds the diode CLOSE (yellow) lightens. Close the ball valve at the topside of the pressure vessel (Illustration 10). 14

open close Illustration 10 Turn the switch VENT / WORK to the position WORK (Illustration 11, 2). Turn the switch PRESSURE / VACUUM to the position VACUUM (Illustration 11, 3). 1 2 3 Illustration 11 Pull out the handle of the pressure regulator. Illustration 12 15

Now turn the handle clockwise (Illustration 13) until 1,0 bar. This will produce a vacuum in the pressure chamber. The more you turn, the lower the pressure in the chamber. You can observe this on the vacuum / pressure gauge (Illustration 13). Illustration 13 Note : Observe the sample carefully during the degassing (Illustration 14). Reduce the pressure in the chamber slowly and constantly. This will stop the sample from bubbling over. This is important, since oil spills might damage the system. Keep the vacuum in the chamber until there are no gas bubbles in the fluid anymore. Illustration 14 16

Turn the handle (illustration 15) anticlockwise until 0,0. Illustration 15 8.2. Sample Feed Turn the switch PRESSURE / VACUUM to the position PRESSURE (Illustration 16, 1). Now turn the handle (Illustration 16, 2) slowly clockwise. This will increase the pressure in the chamber. Continue turning until the gauge (Illustration 16) indicates a pressure of about approximate 3,0 bar. When you hear a hissing noise, the pressure in the chamber is too high. In this case turn the handle anticlockwise until this noise stops. 2 1 Illustration 16 17

Open the ball valve at the top of the pressure vessel (Illustration 15). Turn the switch PRESSURE / VACUUM to the position PRESSURE (Illustration 16, 1). open close Illustration 15 Now you can start the measurement at your particle counter. Please observe the instructions for Bottle Sampling in the manual of your contamination controller. Note : Due to the system design it is unavoidable that at the beginning of the sampling analysis there is air in the supply tube of the contamination controller. If there are only small differences between the individual ranges of particle size, this might point to air bubbles in the measuring system. Therefore repeat the measurement as long as the counting results are stable. Finish the analysis before the whole sample is used up. The ascending tube of the pressure vessel should sufficiently enter the fluid (Illustration 17). Illustration 17 18

After finishing the measurements turn the switch VENT / WORK to the position VENT. You will then hear a hissing noise produced by the air escaping from the pressure chamber. Wait until this is ended, and then turn the switch OPEN / CLOSE to the position OPEN. When the green diode OPEN lights up, the vessel is unlocked and you can remove it by lifting upwards. Remove the sample glass. 9. Cleaning and Maintenance Please keep the device and the feeding tubes absolutely clean. After every use the device has to be flushed. For the flushing please use fine filtered low viscosity oil (e.g. ISOVG22 / ISOVG32). Before operating the BSS2 after a long time of not using it (about 2 weeks), the particle counting device should be flushed properly. For the cleaning of the pressure dome and the device housing please use a soft, fuzz-free cloth. Take care that the ascending tube is not bent while cleaning the pressure chamber. A contamination especially of this component would have negative affects on correct counting results, as it is in direct contact with the sample. Wipe the oil remains away from the plate of the pressure chamber lock and from the sealing area. For the cleaning do not use any aggressive chemical or rubbing agents. 19

10. Technical Data Dimensions: 220 x 240 x 390 Weight: 6,5 kg Initial pressure: 0...4 bar Vacuum: 0...-0,95 bar 10.1. Connections 10.1.1. Electrical Power supply / mains: 230V ~ 50 Hz or 110 V ~ 60 Hz Power supply / device: 12 V DC 10.1.2. Pneumatic Pressure range: Flow rate: Connections: 5...7 bar min. 40 l/min air Rapid action coupling NW 7,2 with internal thread G ¼ Mini-measuring connection with screw coupling M16 x 2 Subject to technical alterations! 20

North America HQ 70 Wood Ave., South, 2nd Floor Iselin, NJ 08830 Toll Free: (800) 656-3344 (North America Only) Voice: (732) 767-4200 China No. 3, Lane 280, Linhong Road Changning District, 200335 Shanghai, P.R. China Voice: +86-21-5200-0099 Singapore 4 Loyang Lane #04-01/02 Singapore 508914 Voice: +65-6825-1668 Europe/Africa/Middle East Friedensstraße 41 D-68804 Altlussheim, Germany Voice: +49-6205-2094-0 Auf der Heide 2 53947 Nettersheim, Germany Voice: +49-2486-809-0 An den Nahewiesen 24 55450 Langenlonsheim, Germany Voice: +49 6704 204-0 Brazil Av. Julia Gaioli, 474 Bonsucesso 07251-500 Guarulhos, Brazil Voice: +55 (11) 2465-8822 For more information, please e-mail us at filtrationinfo@eaton.com Visit us online eaton.com/filtration for a complete list of Eaton s filtration products. 2012 Eaton Corporation. All Rights Reserved. All trademarks and registered trademarks are the property of their respective owners. Litho USA. All information and recommendations appearing in this brochure concerning the use of products described herein are based on tests believed to be reliable. However, it is the user s responsibility to determine the suitability for his own use of such products. Since the actual use by others is beyond our control, no guarantee, expressed or implied, is made by Eaton as to the effects of such use or the results to be obtained. Eaton assumes no liability arising out of the use by others of such products. Nor is the information herein to be construed as absolutely complete, since additional information may be necessary or desirable when particular or exceptional conditions or circumstances exist or because of applicable laws or government regulations.