PROTOCOL FOR COMPRESSED AIR PROFICIENCY TESTING (CAPT) PROGRAM SAMPLE ANALYSIS

Similar documents
STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

EN ISO/IEC Technical Requirements

A. Evaluation of the written program

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)

ANSI / ASSE Z88.2 American National Standard Practices for Respiratory Protection (1992 rev. versus 2015 rev.)

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

UNIVERSITY OF TENNESSEE HEALTH SCIENCE CENTER INSTITUTIONAL REVIEW BOARD CONTINUING REVIEW OF RESEARCH

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

TEXAS DEPARTMENT OF PUBLIC SAFETY Breath Alcohol Laboratory

Proficiency Testing Corrective Action Checklist: PT PROVIDER: PT EVENT: TEST:

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents

Vehicle and Engine Emissions Testing

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

20. Technical Equipment. Archived. This section applies to all equipment used in forensic examinations, such as

Sr. No. General points CPCB Comments 1. Print option, acknowledgement of submission for CPCB OCEMS Protocol

AirCheck Kit Model K901

Quality Assurance Charting for QC Data

ISO INTERNATIONAL STANDARD

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

CORESTA RECOMMENDED METHOD N 6

Yakima County Fire District 12 Standard Operating Guidlines SOG 2-11 Interior Structure Firefighting

Denise L Seman City of Youngstown

Internet Technology Fundamentals. To use a passing score at the percentiles listed below:

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

Evaluation of the Mass Technology Precision Mass Measurement System on Bulk Field-Constructed Tanks (120,000 Gallon Vertical Tank Evaluation)

Sezione Prove Interlaboratorio INFORMATION ON PROFICENCY TEST PROGRAM PIOG

Hydro Plant Risk Assessment Guide

SOP-I-101 Operation and Calibration of the Analytical Balance

Advanced Test Equipment Rentals ATEC (2832)

Evaluating the Influence of R3 Treatments on Fishing License Sales in Pennsylvania

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

UNIVERSITY OF TENNESSEE GRADUATE SCHOOL OF MEDICINE INSTITUTIONAL REVIEW BOARD CONTINUING REVIEW AND REAPPROVAL OF RESEARCH

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

CHM Introductory Laboratory Experiment (r17sd) 1/13

Asphalt Mixture Quality Acceptance

Title: INSTRUMENT AND EQUIPMENT DOCUMENTATION AND RECORDS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Gas Mixture Two Components. Gas Mixtures Two Components

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Article 203 Self-Contained Breathing Apparatus (SCBA)

Human Subjects in Research Review and Monitoring Form. Not applicable

Hazard Communication Plan (HCP) 29 CFR

COAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE

Ohio EPA. Division of Air Pollution Control. Engineering Guide #78. (also known as DSIWM Guidance Document #1001 and #1002)

Yale University Human Research Protection Program

(1) Is large enough and so configured that an employee can bodily enter and perform assigned work; and

STANDARD OPERATING PROCEDURES

AN INTRODUCTION TO COMPRESSED AIR QUALITY for BREATHABLE PURPOSES

Technical Report. 5th Round Robin Test for Multi-Capillary Ventilation Calibration Standards (2016/2017)

UNIVERSITY OF RHODE ISLAND DEPARTMENT OF SAFETY & RISK MANAGEMENT STANDARD OPERATING PROCEDURE

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Hazard Communication Program

Protective Atmospheres, Measurement Technologies and Troubleshooting Tools

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

Working in Gas Hazard Areas

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Controls and Control Charting

TENDER SPECIFICATION No: 12/ of SUPERINTENDING ENGINEER (CTI & ENQUIRIES), Dt

Understanding Dissolved Gas Analysis (DGA) Techniques and Interpretations

QAM-I-117 Volumetric Equipment Calibration Verification

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

EUSMUNC06 (SQA Unit Code - FG2W 04) Locate and avoid supply apparatus for Utilities Network Construction

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Gas Metrology. SI-traceable: Primary Reference Materials Certified Reference Materials Calibrated Gas Mixtures Interlaboratory Comparisons

Service Calibration are you doing it properly?

Homeostasis and Negative Feedback Concepts and Breathing Experiments 1

STANDARDS FOR COMPRESSED GAS TESTING

1. Compute the TWA for the following respirable dust exposures:

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

I N T E R N A T I O N A L S K A T I N G U N I O N

March Madness Basketball Tournament

Chapter 22 Testing Protocols

This test shall be carried out on all vehicles equipped with open type traction batteries.

PIQCS HACCP Minimum Certification Standards

Hot Mix Asphalt (HMA) Quality Assurance

1.2.7 Hazard Communication

9. Extended Range Instructor

Gases and welding distributors continue

Issue Date 11/21/13 Revision Date 01/04/18 Benzene

Gaseous oxygen technical grade Specification

Chapter 7. Coal Cargoes. Properties and Characteristics 7.1

The Following information is based on material prepared by the American Lung Association

DEVELOPMENT AND TESTING OF AIR EXCHANGE RATE METHODS TO IMPROVE COST EFFECTIVENESS WHILE MAINTAINING ACCURACY

SAFETY DATA SHEET - NATURAL GAS

STATE OF CALIFORNIA AIR RESOURCES BOARD AIR MONITORING QUALITY ASSURANCE VOLUME V AUDIT PROCEDURES MANUAL FOR AIR QUALITY MONITORING APPENDIX E

1. HISTORY: This issue publishes a revision of this publication.

Technical Manual. Sensepoint XCD Gas Detector

Confined Space Entry Written Program

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

SOP 407: PROTOCOL DEVIATIONS AND UNANTICIPATED PROBLEMS

Protocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO. Quality Assurance Plan/Standard Operating Procedure

Guidance on room integrity testing and its interpretation

March Madness Basketball Tournament

Transcription:

Contact Information: PROTOCOL FOR COMPRESSED AIR PROFICIENCY TESTING (CAPT) PROGRAM SAMPLE ANALYSIS No formal enrollment is required to participate in the CAPT program. To get added to the email notifications of upcoming rounds you need to contact the coordinating laboratory. This contact is currently Mike Carlson and the email address is mcarlson@airtesting.com. Purpose and Goal: Firefighters using SCBA tanks, divers using SCUBA tanks, and workers using supplied breathing air apparatus are potentially exposed to unhealthy levels of oxygen, carbon monoxide, carbon dioxide, and total volatile hydrocarbons when equipment is not functioning properly. Individual laboratories have developed air sampling equipment and methods to collect representative samples from the breathing-air supply systems and the ambient environment. The laboratories have developed and use analytical procedures to quantify the collected samples. A proficiency testing program will significantly increase the level of confidence in those analytical procedures by demonstrating the ability of the laboratories to correctly quantify the concentration of the typical components of a gas mixture sample. The Compressed Air Proficiency Testing Program (CAPT) is designed to share samples among participating laboratories. The laboratories analyze these samples to demonstrate that accurate analytical results can be generated by independent analysts following their own documented procedures. The CAPT group is open to participation by all analytical laboratories. Background and Definitions: The CAPT group is run by consensus of the participating laboratories. The CAPT group will meet routinely via email, teleconference, site visits, and at general industry events to discuss issues concerning test round performance, laboratory proficiencies, corrective actions, correspondence with accreditation groups, and other program issues. The group will designate a participating laboratory to document and share all decisions with members. For the purposes of this protocol, the laboratory responsible for obtaining and distributing the gas mixture samples is referred to as the coordinating laboratory. The laboratories participating in the program are referred to as the participating laboratories. The coordinating laboratory is designated by the participating laboratories. However the coordinating laboratory must be an accredited laboratory through a national accreditation program such as but not limited to the AIHA or A2LA, using ISO 17025 or equivalent requirements. A laboratory must have a current rating of proficient in order to be a coordinating laboratory for the CAPT program. A coordinating laboratory can also act as a participating laboratory. The sample analysis results are reported to a designated statistical analyst for collating, statistical analysis, and reporting of acceptable/unacceptable results. The statistical analyst is also designated by consensus of the participating laboratories. The statistical analyst can be from a participating laboratory; however, the activities associated with supplying the results for the test rounds shall be kept separate from the activities associated with analyzing the gas mixtures. The samples are ordered from an ISO 9000 registered gas supplier by the coordinating laboratory. The coordinating laboratory notifies the participating laboratories of the proper reference number sample for the proper round. The participating laboratories are responsible for Page 1 of 6

setting up an account with the gas supplier and ordering the correct samples. The samples consist of oxygen, nitrogen, carbon dioxide, carbon monoxide, methane, ethane and total volatile hydrocarbons. The samples are appropriately identified by CAPT round number and analyzed by the participating laboratories per each laboratory s standard analytical methods as if the samples were routine samples obtained from clients. The results obtained are reported as per this protocol. Normally a CAPT testing round will be performed four times per year. There is one cylinder for each round. Each cylinder will have seven reportable analytes. All valid rounds (for definition see statement 1b under heading During each CAPT round, the statistical analyst is responsible for:): will be used to determine acceptable/unacceptable results and reported. A flowchart illustrating the CAPT testing process is provided in Figure 1. The coordinating laboratory will maintain and upon request of any accrediting organizations using the CAPT program provide copies of summary reports, corrective and preventive action reports, and the overall performance statistics per the coordinating laboratory s record retention guidelines. Information is typically, but not required to be, provided in an electronic format. Responsibilities and Procedures: During each CAPT testing round, the coordinating laboratory is responsible for: 1. Ordering gas samples from an ISO 9000 registered gas supplier of the following components and ranges. Oxygen Range 15 to 30% Carbon dioxide Range 300 to 1500 ppm Carbon monoxide Range 5 to 25 ppm Methane Range 5 to 15 ppm Ethane Range 4 to 20 ppm Nitrogen Balance of Mixture (The gas supplier will make a master cylinder mixture and use it to fill cylinders that are sent to the participating laboratories. The gas supplier does not furnish or perform an analysis of the cylinder gas mixture.) 2.Ensuring that sample cylinders are available on and after the dates in the schedule below: 1) January 2 (for the first round of the year) 2) April 1 (for the second round of the year) 3) July 1 (for the third round of the year) 4) October 1 (for the fourth round of the year) 3. Ensuring that the gas vendor: a) Creates a master gas cylinder with concentrations of each analyte within the range called out above. The specific concentration is randomly selected by the gas vendor. The actual value is not known or reported to anyone by the gas vendor. b) Responds to timely to order requests. c) Maintains the master cylinder until the round is complete for the purpose of obtaining additional sample cylinders if there is a need for additional sample cylinders, such as cylinders arriving without adequate sample pressure due to leaks. 4. Handling all questions from participating laboratories with regard to the current round. A record of all issues and responses generated from the round will be documented and Page 2 of 6

communicated to the CAPT participants for further review. No analytical data will be shared until after the round is closed. 5. Promptly notifying the participating laboratories in writing if the round must be repeated due to invalid sample items to be tested. An investigation will be made to determine the nature of the error, potential causes, and recommended corrective and preventive actions. This investigation will be documented and reviewed by the internal QA management of the coordinating laboratory. A summary of findings and corrective/preventive actions will be communicated to the CAPT participants and accrediting organizations using the CAPT program. 6. Maintaining a copy of the correspondence regarding technical assistance, corrective action/preventive action reports, individual laboratory result reports submitted, and summary reports for each round in accordance with internal record keeping policies of the coordinating laboratory. Documents must be retained for a minimum of three years from CAPT round date. During each CAPT round, the participating laboratory is responsible for: 1. Setting up an account with the Gas Supplier. 2. Ordering the proper reference number round sample from the Gas Supplier. 3. Assigning personnel to analyze the samples who have been adequately trained by review of related documents (SOP s, protocols, methods) and shown to be proficient in the analytical technique used for the round. When the coordinating laboratory is also a participating laboratory or the participating laboratory also includes the statistical analyst, the personnel assigned to analyze the round shall not be involved with activities associated with preparing the round reports. Separate notebooks or other laboratory documentation methods consistent with the coordinating laboratory s quality procedures will be maintained for round participation, round coordination, and statistical analysis. 4. Analyzing the gas mixture samples for each round. 5. Reporting analyte test results for all rounds and reporting them by the established due date. Typically there will be four rounds per year performed with the following data submittal deadlines for participating laboratories: 1) February 1 (for the first round of the year) 2) May 1 (for the second round of the year) 3) August 1 (for the third round of the year) 4) November 1 (for the fourth round of the year) 6. Maintaining copies of test-round results reports in accordance with internal record keeping policies of the participating laboratory. During each CAPT round, the statistical analyst is responsible for: Collating the data for the round, determining each participating laboratory s proficiency rating and communicating the proficiency rating to each participating laboratory, and to any accreditation organizations as directed by individual participating laboratories. The statistical analyst determines: 1) Round Performance a) Removal of outliers. Page 3 of 6

The sample results for each analyte will be collated. The statistical control limits will be set by the following criteria. If there are more than five but fewer than 20 reported analytical results for any particular analyte, a calculation is made to determine the mean and the value of two standard deviations. Any results that fall outside the control limits of plus or minus two standard deviations from the mean are judged as outliers and removed from further statistical analysis. If there are more than 20 but fewer than 80 reported analytical results for any particular analyte, a calculation is made of three standard deviations. Any results that fall out side plus or minus three standard deviations from the mean are judged as outliers and removed from further statistical analysis. If there are fewer than five results or more than 80 results for any analyte, no outlier values are removed. In any case, the outliers will only be removed from the data set used for further statistical calculations of mean values and standard deviations to determine acceptable/unacceptable criteria. b) Determination of round validity. Since there are typically seven possible reportable analytes, the validity of each analyte will be determined separately. If more than two analytes are not valid in a round, the entire round is determined to be invalid. The following criterion must be met to determine whether the analyte is valid: overall relative standard deviation (RSD) is less than 20% with outliers removed. c) Actions required by an invalid round. If the RSD criterion is not met, the analyte will be considered invalid. If more than two analytes are invalid, this will create an invalid round. If this happens, the coordinating laboratory will work together with its internal QA management and the CAPT group to immediately investigate the cause(s) of the invalid round and determine appropriate corrective action and preventive action. The coordinating laboratory will notify all participating laboratories of the invalid round, and the round will be repeated or dropped if there are at least two valid rounds that will be completed during the calendar year that contain a total of at least 10 valid analytes. A makeup round shall be performed if necessary to ensure that there are at least 10 valid analytes provided to the CAPT participating laboratories each calendar year. d) Acceptable/unacceptable scores from the statistical analysis of the round analytes. There are two methods used to determine acceptability. One is the Z score limiting values; the other is Absolute Difference. An acceptable score for a round analyte is determined by using the Z score limiting value unless the STDV divided by the numerical value of the Absolute Difference is less than 0.34. Then the Absolute Difference value is used to determine an acceptable score for an individual round analyte. e) Determining Z Score values. i) The mean is calculated for each analyte with outliers removed. ii) The standard deviation is calculated for each analyte with the outliers removed. iii) A Z score is calculated by subtracting the analyte mean value from each laboratory reported analyte value and dividing this by the standard deviation. iv) Any Z score between 3 and +3 (inclusive) is acceptable. Any score less than 3 or greater than +3 is unacceptable. f) Determining Absolute Difference values. Absolute Difference is used because it is possible that some analytes will approach the detection limits on the low end of the analytical ranges or the data set for an analyte is very tightly grouped, thus making the Z values using standard deviations inappropriately small. Page 4 of 6

The Absolute Difference is determined by adding the below respective analyte ranges to the mean value calculated without outliers. An acceptable Absolute Difference score is given to the reported analyte value if it is within the calculated Absolute Difference. Oxygen 1 % Nitrogen 2 % Carbon dioxide 30 ppm Carbon monoxide 2 ppm Methane 2 ppm Total Volatile Hydrocarbons 3 ppm Ethane 3 ppm 2) Lab Performance a) A laboratory must participate in all rounds to be assessed for proficiency (initial or continuing). b) Laboratories are required to report at least five analyte values per round to be assessed for proficiency (initial or continuing). If less than five analyte values are reported by a participating lab on one round the lab will not be rated for proficiency on that round. c) A laboratory s proficiency rating will be based on accumulated results for the last two consecutive rounds. A laboratory will be rated proficient if 90% or more of the accumulated results over the last two consecutive rounds are acceptable. The statistical analyst will determine acceptability of each result submitted using the Z-Score or Absolute Difference methods, as applicable, and will calculate the ratio of the number of acceptable results to the total number of sample results reported and determine the percentage of acceptable results. This percentage will then be compared to the 90% standard stated above to determine the proficiency for each participating laboratory. d) Laboratories using CAPT for accreditation purposes must notify the statistical analyst of non-participation with appropriate excuse information for non- participation consistent with the accreditation organization s policies. The excuse documentation must be submitted to the appropriate accrediting organization along with the CAPT round results. e) The confidentiality of the participating laboratories will be maintained. f) Any issues or concerns that a participating laboratory may have regarding its proficiency rating will be handled by the CAPT group. g) Decisions on all questions before CAPT will be based on sound scientific judgment and without bias and pressures from employer or other outside influences. 3) Round Results Reporting Results are sent to all participating laboratories and accrediting organizations directed by participating laboratories and include the following information: a) Name and address of the coordinating laboratory b) Date of report issue c) Descriptive title d) Laboratories identified by an ID (not by name except versions sent to accrediting organizations with respective laboratories named seeking accreditation) e) Results of the gas sample to be tested (reported in units of ppm by volume and percent as appropriate per analyte) per Lab Performance section above f) Results from all participating parties (reported in units of ppm by volume and percent as appropriate per analyte) and calculated averages and standard deviation per Lab Performance section above Page 5 of 6

Compressed Air Proficiency Test (CAPT) Program Diagram Protocol for Compressed Air Proficiency Testing (CAPT) Program Rev. 6a New Round Started Per CAPT Protocol Schedule Coordinating lab orders CAPT gas mixture samples from ISO 9000-registered gas supplier per protocol for analyte constituents, concentration, and frequency of oftest rounds Gas supplier 1) 1) prepares master cylinder of ofgas mixture per ranges of ofcapt program protocol as directed by coordinating lab and 2) 2) notifies coordinating lab of ofreference number of ofprepared master gas cylinder Participating labs 1) 1) set up account with gas supplier, 2) 2) order proper reference number sample for proper round, 3) 3) analyze gas sample, 4) 4) report results to tothe statistical analyst within protocol time due dates Gas supplier 1) 1) fills individual cylinders--one for each participant s order, 2) 2) sends cylinder samples to toparticipants addresses that have been attached to togas mixture purchase order Statistical analyst 1) 1) determines round performance per published protocol, 2) 2) determines lab performance pass/fail per published protocol, 3) 3) reports anonymous results to tocoordinating lab for review and approval Coordinating lab 1) 1) reviews results of ofround for validity and statistical accuracy 2) 2) approves or ordisapproves of ofresults in inwriting NO Are lab performance values calculated correctly? YES Coordinating lab 1) 1) notifies statistical analyst to toreport anonymous results to to participating labs, 2) 2) notifies statistical analyst to toreport named lab results to to accreditation organizations of ofthose labs requesting this; other results remain anonymous Statistical analyst issues report to toparticipating labs and any accreditation organizations using CAPT results Round ends as valid Are round results valid? YES Coordinating lab reviews round protocol NO Coordinating lab 1) 1) notifies participating labs of ofinvalid round and if ifround needs to tobe repeated per protocol, 2) 2) investigates causes of ofinvalid round per protocol Coordinating lab issues report on invalid round to toparticipating labs and any accreditation organizations using CAPT results Does round need repeating per protocol? NO Round ends as invalid YES Attachment 1: Compressed Air Proficiency Test (CAPT) Program Diagram Page 6 of 6