LINE PROPORTIONERS LP NPR260 Approvals: UL, ULC

Similar documents
SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

HORIZONTAL BLADDER TANK

VERTICAL BLADDER TANK

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Flow Material Length. Weight GPM LPM. Style 3095

TECHNICAL DATA. than the water inlet pressure to the concentrate

FOAM TANK (1/2) DATA SHEET

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA Q= C. Table 1 - Specifications

Wet pipe low flow foam/water system

TECHNICAL DATA NOTICE

ELKHART BRASS MANUFACTURING COMPANY

FOAM TANK (1/2) DATA SHEET

TECHNICAL DATA CAUTION

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

AIR FOAM CHAMBER DATA SHEET

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA OBSOLETE

OBSOLETE DESIGN DATA. CONCENTRATE CONTROLLERS 2, 3", 4", 6" and 8" (50, 80, 100, 150, and 200 mm)

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

Air Eliminators and Combination Air Eliminators Strainers

TECHNICAL DATA. Table 1 - Specifications

Model MTB-ASME Vertical Bladder Tanks

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

TECHNICAL DATA. Trimpac 256a. October 31, 2013

Horizontal Bladder Tanks

Vertical Bladder Tanks

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Anti-flood device Model B-1

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

DAV - WP DAV - WP. Wastewater Air Valves. Product Catalogue. (Wastewater Air Valves) DAV - WP

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Vertical and Horizontal Bladder Tanks

Data Sheet Issue A

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

BALANCED PRESSURE PROPORTIONERS

TECHNICAL DATA CAUTION

Bladder Tank Installation & System Design Information

North American Pressure Switches

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

CASH VALVE TYPE KP BACK PRESSURE VALVES

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

Speed control assembly model A-1

WaterSource Heat Pump Hose Kit Performance Specification-Summary

Foam Systems. Fire Protection Solutions

ECS Protector Nitrogen Inerting Vent (PAV-WN)

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Residential Pressure Booster Systems

Tribomatic II Powder Pump

Propor tional Re lief Valve s

Foam Chamber Model-FC

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

OBSOLETE. Wet pipe low flow manifold system

Proportional Relief Valves

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Full Range Pressure Compensating Variable Flow Control

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

PRESSURE SWITCHES Bulletin 8757

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

Installation Manual. Model # SF-3W 9/16/03 REV 1. Arch Chemicals, Inc Lower River Road. P.O. Box 800 Charleston, TN PULSAR

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

MANUAL FLOW CONTROL 2-1/2" - 18" QUICKSET FLOW CHART

North American 7339 High Pressure Gas Regulators

ANSUL IN-LINE BALANCED PRESSURE PROPORTIONER MANUAL

R122H, R222, R232A, and R232E Series Instruction Manual

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

Models 106-RF / 206-RF Rate of Flow Control Valve

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

Noth American 7347 High Pressure Gas Regulators

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

PRO SINK -R 1 and 2. Dilution system CONTENTS

V43 Pressure Actuated Water Regulating Valve

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

North American Orifice Metering System

First Stage Regulators

Fire & Rescue Service Equipment Manual Branch - Foam Chubb FB5X Foam Making Branch Table of Contents 1 General Description Primary Function...

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

ASSE International Product (Seal) Listing Program

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

PX800 M E T A L PX800 PERFORMANCE WIL T-08

627 Series Pressure Reducing Regulators

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

MR/MRDC/MDC TECHNICAL APPLICATION GUIDE TABLE OF CONTENTS FOR MINI-REGULATOR WITH AND WITHOUT DRAIN CHECK OPTIONS

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

FLOMIXERS SELECTION DATA ALL GASES

Series MG Mixing Tubes

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

Third measurement MEASUREMENT OF PRESSURE

Transcription:

Approvals: UL, ULC Simple Inexpensive & Accurate Foam Proportioning Inlet Pressure Choices 90-200 PSI Flow Rate 44-578 GPM Special Designs Available Flow & Pressure Salt Water Compatible Description National Foam Line Proportioners are venturi devices that introduce Foam Concentrate into a flowing stream of water at a controlled rate of either 3% or 6%. As water flows through the venturi (water orifice) at a high velocity, a negative pressure area develops at the discharge of the venturi. This negative pressure creates a pressure differential across the foam concentrate metering orifice, thereby allowing atmospheric pressure to push foam concentrate in to the proportioner at the correct percentage. As the water pressure at the inlet to the proportioner increases or decreases the solution flow from the device will increase or decrease correspondingly. Because the amount of foam concentrate to be injected into the water stream is controlled by the relationship between the negative pressure area and atmospheric pressure the range over which proper injection occurs is limited. Therefore, each model of line proportioner has an operating pressure range and to achieve optimum performance, the water inlet pressure must be maintained within this range. Higher than design pressure will result in a leaner (lower percentage) mixture; lower than design pressure will result in a richer (higher percentage) mixture. In addition to water pressure, LP s are sensitive to back pressure. Back pressure is the amount of pressure required down stream of the proportioner to discharge the total foam solution flow. This will include the pressure required at the inlet to the discharge device(s), elevation head and line losses. The total allowable back pressure on the discharge side of the LP can not exceed 65% of the water inlet pressure. If back pressure exceeds 65%, the LP may not pick-up foam concentrate or the solution may be lean. When line proportioners are used in a fixed piping systems, the foam concentrate is usually stored in a permanently installed storage tank with permanent piping between the tank and foam concentrate connection of the line proportioner. Features Inexpensive No moving parts Minimal maintenance Simple operation 65% Allowable back pressures Flows up to 400 GPM (1514 LPM) @ 100 PSI (6.9 Bar) Operates with pressures from 75 PSI to 200 PSI (5.2 Bar to 13.8 Bar), however optimum performance is with pressures above 125 PSI (8.6 Bar) Applications The line proportioner is ideally suited to any proportioning application requiring a single fixed discharge flow and relatively high, consistent water pressure. They are not suitable for use in applications requiring operation over a range of flows or pressures. They are not recommended for applications using sprinklers or other multiple small orifice discharge devices, where blockage of a portion of the discharge grid could increase the allowable back pressure sufficiently to cause proportioning failure. Technical Specifications The National Foam Line Proportioner shall be a venturi type proportioning device designed to inject foam concentrate into the water stream at a controlled rate of either 3% or 6% and shall be designed to be permanently installed in a fixed piping system. The proportioner shall be suitable for use with all foam concentrates. Units are designed for operation from 75 PSI (5.2 Bar) to 200 PSI (13.8 Bar), however the model with the correct operating pressure range must be selected to insure proper injection. See chart for available flow and pressure ranges. The proportioner shall be designed to proportion properly with back pressures up 65% of the inlet pressure. The line proportioner shall consist of a cast brass body, a machined jet (venturi) and receiver (recovery section) and foam concentrate orifice. The jet shall be contoured to optimize water flow through the venturi thereby creating the negative pressure area. The receiver shall be shaped to minimize the unrecoverable pressure loss and increase the efficiency of the proportioner. The orifice shall be factory set for 3% or 6% foam injection at the design flow rate and shall proportion within acceptable limits over the operating pressure range. The proportioner shall have a FNPT water inlet connection, a MNPT foam solution discharge connection, and FNPT foam concentrate inlet connection. The proportioner shall be painted with a red fused polyurethane powder coat finish. 06/17 (Rev K) Page 1 of 5

Materials of Construction Material: Body:...Cast Brass Jet:...Brass Foam Orifice:...Brass Finish: Red fused polyurethane powder coat finish Flow Range: 45-400 gpm (170-1514 lpm) @ 100 PSI (6.9 Bar) B Working Pressure: 75 PSI to 200 PSI (5.2 Bar to 13.8 Bar) Max. ABP: 65% of inlet pressure Approvals and Listings Underwriters Laboratories Inc. (UL) Underwriters Laboratories of Canada (ULC) E C - FEMALE NPT FOAM CONCENTRATE INLET Options Pick-Up Tube Kits Available Special Flows & Pressures Upon Request G H - HEX ACROSS FLATS A WATER INLET DISCHARGE F D - MALE NPT LINE PROPORTIONER DIMENSION CHART TABLE OF DIMENSIONS - INCHES(MM) WEIGHT A B C D E F G H LBS (KGS) LP-6 2-1/2(63.5) 2-15/32(62.7) 1/2(12.7) 1-1/2(38.1) 10(254) 1-1/2(38.1) 1-19/32(40.4) 1-1/4(31.8) 6(2.7) LP-9 2-1/2(63.5) 2-5/8(66.8) 1/2(12.7) 1-1/2(38.1) 10-3/8(263.7) 1-1/2(38.1) 1-19/32(40.4) 1-3/8(35.1) 6(2.7) LP-12 3-9/16(90.4) 2-7/8(73.2) 1/2(12.7) 2-1/2(63.5) 14-1/4(362) 2-1/2(63.5) 2-3/8(60.5) 2(50.8) 14(6.4) LP-15 3-3/4(95.3) 4-1/4(108) 1(25.4) 2-1/2(63.5) 16(406.4) 2-1/2(63.5) 2-11/16(68.3) 2-5/8(66.8) 20(9.1) LP-17 3-3/4(95.3) 4-1/4(108) 1(25.4) 2-1/2(63.5) 16(406.4) 2-1/2(63.5) 2-11/16(68.3) 2-5/8(66.8) 20(9.1) LP-20 3-3/4(95.3) 4-1/4(108) 1(25.4) 2-1/2(63.5) 16(406.4) 2-1/2(63.5) 2-11/16(68.3) 2-5/8(66.8) 20(9.1) LP-25 3-3/4(95.3) 4-1/4(108) 1(25.4) 2-1/2(63.5) 16(406.4) 2-1/2(63.5) 2-11/16(68.3) 2-5/8(66.8) 20(9.1) LP-30 3-7/8(98.6) 4-3/4(120.7) 1(25.4) 3(76.2) 18-3/8(466.9) 2-1/2(63.5) 2-31/32(75.4) 3(76.2) 25(11.4) LP-35 3-7/8(98.6) 4-3/4(120.7) 1(25.4) 3(76.2) 18-3/8(466.9) 2-1/2(63.5) 2-31/32(75.4) 3(76.2) 25(11.4) LP-40 3-7/8(98.6) 4-3/4(120.7) 1(25.4) 3(76.2) 18-3/8(466.9) 2-1/2(63.5) 2-31/32(75.4) 3(76.2) 25(11.4) 1. C Dimension is minimum allowable foam concentrate supply pipe sizes. 2. Allow one(1) pipe size larger for AR-AFFF foam concentrate. For Example: 1/2 pipe is 3/4 pipe; 1 pipe is 1-1/4 pipe; 1-1/4 pipe is 1-1/2 pipe etc. Page 2 of 5 06/17 (Rev K)

MODEL LP-6 LP-9 LP-12 LP-15 LP-17 LINE PROPORTIONER SOLUTION FLOW CHART INLET ** SOLUTION FLOW RATE * INLET ** SOLUTION FLOW RATE * PRESSURE 3% (A SERIES) 6% PRESSURE 3% (A SERIES) 6% PSI BAR GPM LPM GPM LPM MODEL PSI BAR GPM LPM GPM LPM 90 6.2 44.3 168 45.7 173 90 6.2 197.1 746 203.4 770 110 7.5 48.2 182 49.8 188 100 6.9 206.0 780 212.6 805 125 8.6 51.0 193 52.7 199 110 7.5 207.8 787 214.5 812 LP-20 135 9.3 52.8 200 54.5 206 135 9.3 234.6 888 242.1 916 165 11.3 57.2 216 59.0 223 165 11.3 254.7 964 262.9 995 200 13.8 63.0 238 65.0 246 200 13.8 280.5 1062 289.5 1096 90 6.2 65.1 246 67.2 254 90 6.2 246.9 935 254.8 964 110 7.5 70.9 268 73.2 277 100 6.9 258.0 977 266.3 1008 125 8.6 75.0 284 77.4 293 110 7.5 268.8 1017 277.3 1050 LP-25 135 9.3 77.5 293 80.0 303 135 9.3 293.9 1112 303.3 1148 165 11.3 84.2 319 86.9 329 165 11.3 319.1 1208 329.3 1246 200 13.8 92.7 351 95.6 362 200 13.8 351.3 1330 362.6 1372 90 6.2 89.5 339 92.3 349 90 6.2 294.7 1115 304.1 1151 100 6.9 97.4 369 100.5 380 100 6.9 308.0 1166 317.9 1203 110 7.5 103.0 390 106.3 402 110 7.5 320.8 1214 331.1 1253 LP-30 135 9.3 106.5 403 109.9 416 135 9.3 350.8 1328 362.0 1370 165 11.3 115.7 438 119.4 452 165 11.3 380.9 1442 393.1 1488 200 13.8 127.3 482 131.4 497 200 13.8 419.4 1587 432.8 1638 90 6.2 148.4 562 153.1 579 90 6.2 345.5 1308 356.5 1349 100 6.9 155.0 587 160.0 606 100 6.9 361.0 1366 372.6 1410 110 7.5 161.4 611 166.6 631 110 7.5 376.0 1423 388.0 1469 LP-35 135 9.3 176.6 668 182.2 690 135 9.3 411.2 1556 424.4 1606 165 11.3 191.8 726 197.9 749 165 11.3 446.4 1689 460.7 1744 200 13.8 211.0 799 217.8 824 200 13.8 491.5 1860 507.2 1920 90 6.2 167.5 634 172.9 654 90 6.2 394.3 1492 406.9 1540 100 6.9 175.0 662 180.6 684 100 6.9 412.0 1559 425.1 1609 110 7.5 182.3 690 188.1 712 110 7.5 429.2 1625 442.9 1676 LP-40 135 9.3 199.4 755 205.7 779 135 9.3 469.4 1777 484.4 1833 165 11.3 216.4 819 223.3 845 165 11.3 509.6 1929 525.9 1991 200 13.8 238.0 901 246.0 931 200 13.8 561.0 2123 578.9 2191 * All figures are engineering values. Actual flows may vary plus or minus 4% of stated values. ** Flow shown is for pressure noted. See model number suffix for acceptable pressure range for each model. Example: LP-6-90. Pressure range for each model number is as follows: LP-X-90... 75 PSI TO 90 PSI (5.2 BAR TO 6.2 BAR) LP-X-110... 91 PSI TO 110 PSI (6.3 BAR TO 7.5 BAR) LP-X-135... 111 PSI TO 135 PSI (7.6 BAR TO 9.3 BAR) LP-X-165... 136 PSI TO 165 PSI (9.4 BAR TO 11.3 BAR) LP-X-200... 166 PSI TO 200 PSI (11.4 BAR TO 13.8 BAR) 06/17 (Rev K) Page 3 of 5

ORDERING INFORMATION PART NUMBER MODEL # % DESCRIPTION PART NUMBER MODEL # % DESCRIPTION 1233-1200-3 LP-6-90 (6%) Line Proportioner 1233-4200-3 LP-20-90 (6%) Line Proportioner 1233-1210-3 LP-6-110 (6%) Line Proportioner 1233-4210-3 LP-20-110 (6%) Line Proportioner 1233-1220-3 LP-6-135 (6%) Line Proportioner 1233-4220-3 LP-20-135 (6%) Line Proportioner 1233-1230-3 LP-6-165 (6%) Line Proportioner 1233-4230-3 LP-20-165 (6%) Line Proportioner 1233-1240-3 LP-6-200 (6%) Line Proportioner 1233-4240-3 LP-20-200 (6%) Line Proportioner 1233-1250-3 LP-6A-90 (3%) Line Proportioner 1233-4250-3 LP-20A-90 (3%) Line Proportioner 1233-1260-3 LP-6A-110 (3%) Line Proportioner 1233-4260-3 LP-20A-110 (3%) Line Proportioner 1233-1270-3 LP-6A-135 (3%) Line Proportioner 1233-4270-3 LP-20A-135 (3%) Line Proportioner 1233-1280-3 LP-6A-165 (3%) Line Proportioner 1233-4280-3 LP-20A-165 (3%) Line Proportioner 1233-1290-3 LP-6A-200 (3%) Line Proportioner 1233-4290-3 LP-20A-200 (3%) Line Proportioner 1233-1600-3 LP-9-90 (6%) Line Proportioner 1233-4700-3 LP-25-90 (6%) Line Proportioner 1233-1610-3 LP-9-110 (6%) Line Proportioner 1233-4710-3 LP-25-110 (6%) Line Proportioner 1233-1620-3 LP-9-135 (6%) Line Proportioner 1233-4720-3 LP-25-135 (6%) Line Proportioner 1233-1630-3 LP-9-165 (6%) Line Proportioner 1233-4730-3 LP-25-165 (6%) Line Proportioner 1233-1640-4 LP-9-200 (6%) Line Proportioner 1233-4740-3 LP-25-200 (6%) Line Proportioner 1233-1650-3 LP-9A-90 (3%) Line Proportioner 1233-4750-3 LP-25A-90 (3%) Line Proportioner 1233-1660-4 LP-9A-110 (3%) Line Proportioner 1233-4760-3 LP-25A-110 (3%) Line Proportioner 1233-1670-4 LP-9A-135 (3%) Line Proportioner 1233-4770-3 LP-25A-135 (3%) Line Proportioner 1233-1680-3 LP-9A-165 (3%) Line Proportioner 1233-4780-3 LP-25A-165 (3%) Line Proportioner 1233-1690-4 LP-9A-200 (3%) Line Proportioner 1233-4790-3 LP-25A-200 (3%) Line Proportioner 1233-2200-3 LP-12-90 (6%) Line Proportioner 1233-5200-3 LP-30-90 (6%) Line Proportioner 1233-2210-3 LP-12-110 (6%) Line Proportioner 1233-5210-3 LP-30-110 (6%) Line Proportioner 1233-2220-3 LP-12-135 (6%) Line Proportioner 1233-5220-3 LP-30-135 (6%) Line Proportioner 1233-2230-3 LP-12-165 (6%) Line Proportioner 1233-5230-3 LP-30-165 (6%) Line Proportioner 1233-2240-3 LP-12-200 (6%) Line Proportioner 1233-5240-3 LP-30-200 (6%) Line Proportioner 1233-2250-3 LP-12A-90 (3%) Line Proportioner 1233-5250-3 LP-30A-90 (3%) Line Proportioner 1233-2260-3 LP-12A-110 (3%) Line Proportioner 1233-5260-3 LP-30A-110 (3%) Line Proportioner 1233-2270-3 LP-12A-135 (3%) Line Proportioner 1233-5270-3 LP-30A-135 (3%) Line Proportioner 1233-2280-3 LP-12A-165 (3%) Line Proportioner 1233-5280-3 LP-30A-165 (3%) Line Proportioner 1233-2290-3 LP-12A-200 (3%) Line Proportioner 1233-5290-3 LP-30A-200 (3%) Line Proportioner 1233-2700-3 LP-15-90 (6%) Line Proportioner 1233-5700-3 LP-35-90 (6%) Line Proportioner 1233-2710-3 LP-15-110 (6%) Line Proportioner 1233-5710-3 LP-35-110 (6%) Line Proportioner 1233-2720-3 LP-15-135 (6%) Line Proportioner 1233-5720-3 LP-35-135 (6%) Line Proportioner 1233-2730-3 LP-15-165 (6%) Line Proportioner 1233-5730-3 LP-35-165 (6%) Line Proportioner 1233-2740-3 LP-15-200 (6%) Line Proportioner 1233-5740-3 LP-35-200 (6%) Line Proportioner 1233-2750-3 LP-15A-90 (3%) Line Proportioner 1233-5750-3 LP-35A-90 (3%) Line Proportioner 1233-2760-3 LP-15A-110 (3%) Line Proportioner 1233-5760-3 LP-35A-110 (3%) Line Proportioner 1233-2770-3 LP-15A-135 (3%) Line Proportioner 1233-5770-3 LP-35A-135 (3%) Line Proportioner 1233-2780-3 LP-15A-165 (3%) Line Proportioner 1233-5780-3 LP-35A-165 (3%) Line Proportioner 1233-2790-3 LP-15A-200 (3%) Line Proportioner 1233-5790-3 LP-35A-200 (3%) Line Proportioner 1233-3200-3 LP-17-90 (6%) Line Proportioner 1233-6200-3 LP-40-90 (6%) Line Proportioner 1233-3210-3 LP-17-110 (6%) Line Proportioner 1233-6210-3 LP-40-110 (6%) Line Proportioner 1233-3220-3 LP-17-135 (6%) Line Proportioner 1233-6220-3 LP-40-135 (6%) Line Proportioner 1233-3230-3 LP-17-165 (6%) Line Proportioner 1233-6230-3 LP-40-165 (6%) Line Proportioner 1233-3240-3 LP-17-200 (6%) Line Proportioner 1233-6240-3 LP-40-200 (6%) Line Proportioner 1233-3250-3 LP-17A-90 (3%) Line Proportioner 1233-6250-3 LP-40A-90 (3%) Line Proportioner 1233-3260-3 LP-17A-110 (3%) Line Proportioner 1233-6260-3 LP-40A-110 (3%) Line Proportioner 1233-3270-3 LP-17A-135 (3%) Line Proportioner 1233-6270-3 LP-40A-135 (3%) Line Proportioner 1233-3280-3 LP-17A-165 (3%) Line Proportioner 1233-6280-3 LP-40A-165 (3%) Line Proportioner 1233-3290-3 LP-17A-200 (3%) Line Proportioner 1233-6290-3 LP-40A-200 (3%) Line Proportioner Indicates UL, ULC Listed Note: Ordering Information for Optional Equipment on Page 5. Page 4 of 5 06/17 (Rev K)

ORDERING INFORMATION OPTIONAL EQUIPMENT Part Number Description Pick-up Tube Components LP-6, LP-9 & LP-12 1231-1152-6 1/2 Check Valve 9228-8341-5 1/2 Nipple 1247-1020-3 PT-2A Pick-Up Tube Pick-up Tube Components LP-15 Through LP-25 1231-1155-1 1 Check Valve 9228-8342-2 1 Nipple 1247-1020-7 PT-3A Pick-Up Tube Pick-up Tube Components LP-30 Through LP40 1231-1155-1 1 Check Valve 9228-8342-2 1 Nipple 1247-1021-1 PT4A Pick Up Tube 06/17 (Rev K) Page 5 of 5 National Foam 350 East Union Street, West Chester, PA 19382, USA 24hr RED ALERT : 610-363-1400 Fax: 610-431-7084 www.nationalfoam.com National Foam operates a continuous program of product development. The right is therefore reserved to modify any specification without prior notice and National Foam should be contacted to ensure that the current issues of all technical data sheets are used. National Foam