HOT SPOT MONITOR (HSM)

Similar documents
HART Communications Board

APPLICATION NOTE. OJ-DV Modbus protocol. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS E 03/18 (PDJ) 2018 OJ Electronics A/S

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Technical Bulletin, Communicating with Gas Chromatographs

AN-140. Protege WX SALLIS Integration Application Note

Injection Controller Program User Manual (for FloBoss 107 and ROC800-Series)

Product Overview. Product Description CHAPTER

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007

Astral in AirView: Improving patient care through connectivity. ResMed.com

Datasheet: K-30 ASCII Sensor

EZ Boom 2010 System for the EZ Guide 500 Lightbar Triangle Ag Services Users Guide

SonoSelect 10 and SonoSafe 10 energy meters

FTC130 Transmitter. Operating Manual

Design Envelope Booster. Sequence of operation

IRceL Operating Instructions

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

Figure SM1: Front panel of the multipatcher software graphic user interface (GUI) at the beginning of multipatcher operation.

Astral in AirView: Improving patient care through connectivity. ResMed.com

HyperSecureLink V6.0x User Guide

PRODUCT MANUAL. Diver-MOD

SonoMeter 30 Energy Meters

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Instruction Manual. BZ7002 Calibration Software BE

SHIMADZU LC-10/20 PUMP

DeeterFlow Automatic Liquid Dispenser

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

Description of Device Parameters Proline Prowirl 200 HART. Vortex flowmeter. Products Solutions Services. Main menu Language.

Panther 5 Acute Care Ventilator

User manual CF8-D/W-IN

Quick Guide. SGX-CA500 Cycle Computer SGY-PM Series Power Meters

Met One E-BAM Particulate Monitor

PC Configuration software for Discovery MkVI v 1.03 User guide

Measuring range Δp (span = 100%) Pa

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD.

Oxygen Meter User Manual

Polycom VVX SERIES. Expansion Module Administrator Guide. Table of Contents

Installation and Operation Manual

MyNetball Club Training Manual

ASG-SD2500 ASG-SD2500

Hydro-Control V User Guide

Page 2 of 46 Prepared by: Engr. Ram Sankar

CNC Communication Protocol

Airflow Options for Cisco MDS 9396S SAN Switch

Dräger X-dock Frequently Asked Questions

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Safety Manual VEGAVIB series 60

IntesisBox PA-AW-KNX-1

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

Doc. no.dit om005 PRODUCT NAME. IO-Link/ELECTRO-PNEUMATIC REGULATOR. MODEL / Series / Product Number ITV*0*0-IO****-X395

Built-in Purge Control Functions

EZ-Boom 2010 Automated Application Control System Quick Reference Card INTRODUCTION

Water Temperature Control - Groups of Fixtures

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

FIG: 27.1 Tool String

Flow Vision I MX Gas Blending Station

Ultima. X Series Gas Monitor

4000 series (includes 4100, 4200 & 4900)

BathySurvey A Trimble Access hydrographic survey module

DST Host User Manual

Controlling the prefeeder

IntesisBox PA-AW-KNX-1

HY-OPTIMA 740 In-Line Process Hydrogen Analyzer (%H 2 S & CO)

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

OC508 Programmable mv Calibrator

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

X-dock Software History

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

CHLORINE DIOXIDE GENERATOR

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

These Terms and conditions apply to audit trails incorporated in weighing and measuring devices and systems 1.

Rcvr-Acct#: Date: May 3, :31 AM

FIXED POINT SINGLE OR DUAL GAS MONITOR WITH DUAL ANALOG OUTPUTS

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

theben Continuous valve actuator CHEOPS drive CHEOPS drive As of: Jul-11 (Subject to change without notice) Page 1 of 41

Calibration Procedure

TECHNICAL NOTE HOW TO USE LOOPERS. Kalipso_TechDocs_Loopers. Revision: 1.0. Kalipso version: Date: 16/02/2017.

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules

CUSTOMER INFORMATION

Help Manual. (ROAD Edition)

Full-Time Referee Appointments Version 5.0

P3000 Deadweight Tester Setup, Part 1: Limited Partial Correction Method

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

Fixed Ozone Monitor User Manual December, Automatikprodukter

Qualification of Fastrak & First Gen Product to Railway applications Shock and Vibration Standard EN 61373

IMPACT LOCATION SETUP. Updated July 2018

MCS-Magnum Unsafe and Low Suction Control

EnCal 3000 Gas Chromatograph Commissioning and Maintenance Manual Biogas and THT-Devices

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

Helium Level Measurement Unit

MZA 6010 Multi-Zone, Multi-Gas IR Analyzer (CO, CO 2, and CH 4 Gas Analyzer with % Carbon Calculation and Optional H 2 Measurement) Operations Manual

Overview. Front Panel: Keypad and Display

LONG TERM SITE WIND DATA ANNUAL REPORT. Mass Turnpike Authority Blandford, MA

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Operation of the Perkin Elmer TGA-GC/MS

User s manual VCI07. For variable speed compressors ed00. Applicable as of Version 12. Bar PSI C F

Transcription:

HOT SPOT MONITOR (HSM) EDS FILE TECHNICAL NOTE INSERTING EDS TO ROCKWELL STUDIO 5000 Follow the below steps to add GraceSense TM Hot Spot Monitor (HSM) product via Ethernet IP to your project. Download the Hot Spot Monitor EDS file from Gracesense.com. and open your RA Studio 5000 program. Step 1: EDS Hardware Installation. Go to Tools drop down menu in Studio 5000 and select EDS Hardware install tool. Follow wizard setup (continued) Wizard will open follow wizard setup Grace Engineered Products, Inc. All rights reserved. Specifications are subject to change with/without notice. GS-HSM-TN1-EN 1703 1515 East Kimberly Road Davenport, IA www.gracesense.com 1.800.280.9517

Step 2: Add module G-HSM-9SM to system. Under the controller tree Right click on Ethernet Example: Unit 114 Step 3: New module configuration. Assign name and set IP Address of unit and setup instances by clicking on change. Example: Name: Unit 114, IP Address: 10.0.10.114 Upon clicking change add desired instances available via the EDS File. Example: Unit 114 Add a new Module - under Select Module Type. Search for Grace Engineered Products and select correct model and click create. Added all Instances available See Appendix A. Click ok Unit will now be available in the tree and tags will be displayed Now you are ready to begin your programming

Document 50089-1F-LST-REGISTER-GRACE-HSM.xlsx Date created: 2016-11-25 Rev Date: 2017-3-10 INT: LH Category Range Genaral Parameters Instance 101 Modbus Memory Map for Grace HSM Register Name: Data Register Description: Default Range, format: UOM: EIP Offset *2 Interpretation P Instan PCB Serial No. LSB I1.Data[0] LSW of Serial Number N/A 0-65535 N/A 0 System Time Board PCB Serial No. MSB I1.Data[2] MSW of Serial Number N/A 0-65535 N/A 1 HW P/N I1.Data[4] HW Part Number 10121 0-65535 N/A 2 FW Rev I1.Data[6] FW Revision N/A 0-65535 N/A 3 Day I1.Data[8] Device Days from RTC N/A 1-31 N/A 4 Month I1.Data[10] Device Months from RTC N/A 1-12 N/A 5 Year I1.Data[12] Device Years from RTC N/A 2000-2099 N/A 6 Hour I1.Data[14] Device Hours from RTC N/A 0-23 N/A 7 Min I1.Data[16] Device Minutes from RTC N/A 0-59 N/A 8 Sec I1.Data[18] Device Seconds from RTC N/A 0-59 N/A 9 Mem Capacity I1.Data[20] Amount of Log Storage Memory N/A 0-100 % 10 BM0 I1.Data[22] Board Map 0 for determining the type of HSM configuration N/A 0x0000-0x003F N/A 11 Temp in C Instance 102 Temp C 1 I2.Data[0] Temperature in C of Ch 1 N/A -50-200, -999, 0x7FFF C 0 Temp C 2 I2.Data[2] Temperature in C of Ch 2 N/A -50-200, -999, 0x7FFF C 1 Temp C 3 I2.Data[4] Temperature in C of Ch 3 N/A -50-200, -999, 0x7FFF C 2 TempC Instance 102 (size: 36 bytes) Device Instance 101 (size: 24 bytes) Temp C 4 I2.Data[6] Temperature in C of Ch 4 N/A -50-200, -999, 0x7FFF C 3 Temp C 5 I2.Data[8] Temperature in C of Ch 5 N/A -50-200, -999, 0x7FFF C 4 Temp C 6 I2.Data[10] Temperature in C of Ch 6 N/A -50-200, -999, 0x7FFF C 5 Temp C 7 I2.Data[12] Temperature in C of Ch 7 N/A -50-200, -999, 0x7FFF C 6 Temp C 8 I2.Data[14] Temperature in C of Ch 8 N/A -50-200, -999, 0x7FFF C 7 Temp C 9 I2.Data[16] Temperature in C of Ch 9 N/A -50-200, -999, 0x7FFF C 8 Temp C 10 I2.Data[20] Temperature in C of Ch 10 N/A -50-200, -999, 0x7FFF C 9 Temp C 11 I2.Data[22] Temperature in C of Ch 11 N/A -50-200, -999, 0x7FFF C 10 Temp C 12 I2.Data[24] Temperature in C of Ch 12 N/A -50-200, -999, 0x7FFF C 11 Temp C 13 I2.Data[26] Temperature in C of Ch 13 N/A -50-200, -999, 0x7FFF C 12 Temp C 14 I2.Data[28] Temperature in C of Ch 14 N/A -50-200, -999, 0x7FFF C 13 Temp C 15 I2.Data[30] Temperature in C of Ch 15 N/A -50-200, -999, 0x7FFF C 14 (-)999 - Temperature invalid 0x7FFF - HSM module error Temp C 16 I2.Data[32] Temperature in C of Ch 16 N/A -50-200, -999, 0x7FFF C 15 Temp C 17 I2.Data[34] Temperature in C of Ch 17 N/A -50-200, -999, 0x7FFF C 16 Temp C 18 I2.Data[36] Temperature in C of Ch 18 N/A -50-200, -999, 0x7FFF C 17

ytes) TempF Instance 103 (size: 36 bytes) Temp in F Instance 103 Temp F 1 I3.Data[0] Temperature in F of Ch 1 N/A -58-392, -999, 0x7FFF F 0 Temp F 2 I3.Data[2] Temperature in F of Ch 2 N/A -58-392, -999, 0x7FFF F 1 Temp F 3 I3.Data[4] Temperature in F of Ch 3 N/A -58-392, -999, 0x7FFF F 2 Temp F 4 I3.Data[6] Temperature in F of Ch 4 N/A -58-392, -999, 0x7FFF F 3 Temp F 5 I3.Data[8] Temperature in F of Ch 5 N/A -58-392, -999, 0x7FFF F 4 Temp F 6 I3.Data[10] Temperature in F of Ch 6 N/A -58-392, -999, 0x7FFF F 5 Temp F 7 I3.Data[12] Temperature in F of Ch 7 N/A -58-392, -999, 0x7FFF F 6 Temp F 8 I3.Data[14] Temperature in F of Ch 8 N/A -58-392, -999, 0x7FFF F 7 Temp F 9 I3.Data[16] Temperature in F of Ch 9 N/A -58-392, -999, 0x7FFF F 8 Temp F 10 I3.Data[20] Temperature in F of Ch 10 N/A -58-392, -999, 0x7FFF F 9 0x7FFF - HSM module error Temp F 11 I3.Data[22] Temperature in F of Ch 11 N/A -58-392, -999, 0x7FFF F 10 Temp F 12 I3.Data[24] Temperature in F of Ch 12 N/A -58-392, -999, 0x7FFF F 11 Temp F 13 I3.Data[26] Temperature in F of Ch 13 N/A -58-392, -999, 0x7FFF F 12 Temp F 14 I3.Data[28] Temperature in F of Ch 14 N/A -58-392, -999, 0x7FFF F 13 Temp F 15 I3.Data[30] Temperature in F of Ch 15 N/A -58-392, -999, 0x7FFF F 14 Temp F 16 I3.Data[32] Temperature in F of Ch 16 N/A -58-392, -999, 0x7FFF F 15 Temp F 17 I3.Data[34] Temperature in F of Ch 17 N/A -58-392, -999, 0x7FFF F 16 Temp F 18 I3.Data[36] Temperature in F of Ch 18 N/A -58-392, -999, 0x7FFF F 17 Temperature Alarm Registers Instance 104 Alert Lvl I4.Data[0] Alert Level for operator 0 0-2 N/A 0 0 = OK, 1 = Warning, 2= Alar I4.Data[1] N/A Alert Code 1 I4.Data[2] HSM Alert Code slot 1 0 0x0000-0x0312 N/A 1 CH Code I4.Data[3] Channel Alarm Status Alert Code 2 I4.Data[4] HSM Alert Code slot 2 0 0x0000-0x0312 N/A 2 CH Code I4.Data[5] Channel Alarm Status Example Alarm 0x0310 Alert Code 3 I4.Data[6] HSM Alert Code slot 3 0 0x0000-0x0312 N/A 3 CH Code I4.Data[7] Channel Alarm Status Alert Code 4 I4.Data[8] HSM Alert Code slot 4 0 0x0000-0x0312 N/A 4 CH Code I4.Data[9] Channel Alarm Status Alert Code 5 I4.Data[10] HSM Alert Code slot 5 0 0x0000-0x0312 N/A 5 CH Code I4.Data[11] Channel Alarm Status Alert Code 6 I4.Data[12] HSM Alert Code slot 6 0 0x0000-0x0312 N/A 6 CH Code I4.Data[13] Channel Alarm Status Alert Code7 I4.Data[14] HSM Alert Code slot 7 0 0x0000-0x0312 N/A 7 CH Code I4.Data[15] Channel Alarm Status Alert Code 8 I4.Data[16] HSM Alert Code slot 8 0 0x0000-0x0312 N/A 8 CH Code I4.Data[17] Channel Alarm Status Alert Code 9 I4.Data[18] HSM Alert Code slot 9 0 0x0000-0x0312 N/A 9 First byte of the word: (0x03) indicates type of error 0x00. no error 0x01 temperature warning... priority medium 0x02 temperature alarm Priority highest 0x03 sensor module error... priority lowest Second byte of the word: (0x10) indicates the channel 0x10 channel 16 CH Code I4.Data[19] Channel Alarm Status Alert Code 10 I4.Data[20] HSM Alert Code slot 10 0 0x0000-0x0312 N/A 10 CH Code I4.Data[21] Channel Alarm Status

Alarm Instance 104 (size: 56 by primarywarningsetpointc I4.Data[22] The Primary Warning Temperature Threshold in C 90-50 - 200 C 11 I4.Data[23] N/A primaryalarmsetpointc I4.Data[24] The Primary Alarm Temperature Threshold in C 105-50 - 200 C 12 I4.Data[25] N/A primarywarningsetpointf I4.Data[26] The Primary Warning Temperature Threshold in F 194-58 - 392 F 13 I4.Data[27] N/A primaryalarmsetpointf I4.Data[28] The Primary Alarm Temperature Threshold in F 221-58 - 392 F 14 I4.Data[29] N/A warningflaghi I4.Data[30] Warning flags CH 1-8 N/A 0x0000-0x0003 N/A 15 warningflaghi I4.Data[31] Warning flags CH 9-16 N/A 0x0000-0x0003 N/A warningflaglo I4.Data[32] Warning flags CH 17-18 N/A 0x0000-0xFFFF N/A 16 alarmflaghi I4.Data[34] Alarm flags CH 1-8 N/A 0x0000-0x0003 N/A 17 alarmflaghi I4.Data[35] Alarm flags CH 9-16 N/A 0x0000-0x0003 N/A alarmflaglo I4.Data[36] Alarm flags CH 16-18 N/A 0x0000-0xFFFF N/A 18 relayenableflaghi I4.Data[38] Channel relay Enable (Alarm Only) CH 1-8 N/A 0x0000-0x0003 N/A 19 warningflaghi I4.Data[39] Channel relay Enable (Alarm Only) CH 9-16 N/A 0x0000-0x0003 N/A relayenableflaglo I4.Data[40] Channel relay Enable (Alarm Only) CH 17-18 N/A 0x0000-0xFFFF N/A 20 I4.Data[41] N/A secondarysetpointselectflaghi I4.Data[42] Enable primary or secondary setpoint CH 1-8 N/A 0x0000-0x0003 N/A 21 secondarysetpointselectflaghi I4.Data[43] Enable primary or secondary setpoint CH 9-16 N/A 0x0000-0x0003 N/A secondarysetpointselectflaglo I4.Data[44] Enable primary or secondary setpoint CH 17-18 N/A 0x0000-0xFFFF N/A 22 secondarywarningsetpointc I4.Data[46] The Secondary Warning Temperature Threshold in C 90-50 - 200 C 23 I4.Data[47] N/A secondaryalarmsetpointc I4.Data[48] The Secondary Alarm Temperature Threshold in C 105-50 - 200 C 24 I4.Data[49] N/A secondarywarningsetpointf I4.Data[50] The Secondary Warning Temperature Threshold in F 194-58 - 392 F 25 I4.Data[51] N/A secondaryalarmsetpointf I4.Data[52] The Secondary Alarm Temperature Threshold in F 221-58 - 392 F 26 I4.Data[53] N/A relaystatus I4.Data[54] The current status of the Relay N/A 0-1 On/Off 27 Bitwise representation the channel warning and alarm status: Example: register 30057= 0x1492=0001 0100 1001 0010: D1(CH2=1), D4(CH5=1), D7(CH8=1), D10(CH11=1),

MCS 1 Instance 105 (size: 64 bytes) relaystatus I4.Data[54] The current status of the Relay N/A 0-1 On/Off 27 Modbus Current Sensor MCS1 Instance 105 IR_SN_LO_1 I5.Data[0] Lower 16 bits of the Serial Number N/A 0-65535 N/A 0 IR_SN_HI_1 I5.Data[2] Upper 16 bits of the Serial Number N/A 0-65535 N/A 1 IR_FW_REV_1 I5.Data[4] Firmware Revision N/A 0-65535 N/A 2 IR_TURN_RATIO_HI_1 I5.Data[6] Low Side (secondary) turn ratio (eg. the 1 in 1:500) 1 0-65535 N/A 3 IR_TURN_RATIO_LO_1 I5.Data[8] High side (primary) turn ratio (eg. the 500 in 1:500) 500 0-65535 N/A 4 IR_DC_OFFSET_1 I5.Data[10] User adjustable zero offset 1-32767 - 32767 N/A 5 IR_MANU_DAY_1 I5.Data[12] Day of the month when calibrated (manufactured) N/A 1-31 N/A 6 IR_MANU_MONTH_1 I5.Data[14] The month when calibrated (manufactured) N/A 1-12 N/A 7 IR_MANU_YEAR_1 I5.Data[16] The year when calibrated (manufactured) N/A 2000-2999 N/A 8 IR_MA_DC_LO_1 I5.Data[20] Lower 16 bits of the DC current in milliamps N/A -32767-32767 ma 9 IR_MA_DC_HI_1 I5.Data[22] Upper 16 bits of the DC current in milliamps N/A -32767-32767 ma 10 IR_MA_RMS_1 I5.Data[24] AC RMS current in ma N/A 0-65535 ma 11 IR_A_PRIMARY_RMS_1 I5.Data[26] Primary side (after the turns ratio) of the AC RMS current in A N/A 0-65535 A 12 IR_AVG_MA_RMS_1 I5.Data[28] Averaged AC RMS current in ma N/A 0-65535 ma 13 IR_AVG_A_PRIMARY_RMS_1 I5.Data[30] Averaged Primary side (after the turns ratio) of the AC RMS current in A N/A 0-65535 A 14 IR_MAX_PEAK_LO_1 I5.Data[32] Lower 16 bits of peak-to-peak current N/A -32767-32767 N/A 15 IR_MAX_PEAK_HI_1 I5.Data[34] Upper 16 bits peak-to-peak current N/A -32767-32767 N/A 16 IR_CREST_1 I5.Data[36] Cresting factor of the RMS reading as % N/A 0-65535 % 17 IR_FREQUENCY_1 I5.Data[38] Frequency of the current (triggers from +- 100 ADC signal) N/A 0-65535 N/A 18 IR_TICK_1 I5.Data[40] MCSs tick to see if it is still running N/A 0-65535 N/A 19 IR_TEMP_1 I5.Data[42] The approximate temperature of the MCS board N/A -40-105 ºC 20 IR_MS_MA_LO_1 I5.Data[44] Lower 16 bits of the instantaneous squared mean current in ma N/A 0-65535 ma^2 21 IR_MS_MA_HI_1 I5.Data[46] Upper 16 bits of the instantaneous squared mean current in ma N/A 0-65535 ma^2 22

MCS 2 Instance 106 (size: 64 bytes) IR_MS_MA_HI_1 I5.Data[46] Upper 16 bits of the instantaneous squared mean current in ma N/A 0-65535 ma^2 22 Modbus Current Sensor MCS2 Instance 106 IR_SN_LO_2 I6.Data[0] Lower 16 bits of the Serial Number N/A 0-65535 N/A 0 IR_SN_HI_2 I6.Data[2] Upper 16 bits of the Serial Number N/A 0-65535 N/A 1 IR_FW_REV_2 I6.Data[4] Firmware Revision N/A 0-65535 N/A 2 IR_TURN_RATIO_HI_2 I6.Data[6] Low Side (secondary) turn ratio (eg. the 1 in 1:500) 1 0-65535 N/A 3 IR_TURN_RATIO_LO_2 I6.Data[8] High side (primary) turn ratio (eg. the 500 in 1:500) 500 0-65535 N/A 4 IR_DC_OFFSET_2 I6.Data[10] User adjustable zero offset 1-32767 - 32767 N/A 5 IR_MANU_DAY_2 I6.Data[12] Day of the month when calibrated (manufactured) N/A 1-31 N/A 6 IR_MANU_MONTH_2 I6.Data[14] The month when calibrated (manufactured) N/A 1-12 N/A 7 IR_MANU_YEAR_2 I6.Data[16] The year when calibrated (manufactured) N/A 2000-2999 N/A 8 IR_MA_DC_LO_2 I6.Data[20] Lower 16 bits of the DC current in milliamps N/A -32767-32767 ma 9 IR_MA_DC_HI_2 I6.Data[22] Upper 16 bits of the DC current in milliamps N/A -32767-32767 ma 10 IR_MA_RMS_2 I6.Data[24] AC RMS current in ma N/A 0-65535 ma 11 IR_A_PRIMARY_RMS_2 I6.Data[26] Primary side (after the turns ratio) of the AC RMS current in A N/A 0-65535 A 12 IR_AVG_MA_RMS_2 I6.Data[28] Averaged AC RMS current in ma N/A 0-65535 ma 13 IR_AVG_A_PRIMARY_RMS_2 I6.Data[30] Averaged Primary side (after the turns ratio) of the AC RMS current in A N/A 0-65535 A 14 IR_MAX_PEAK_LO_2 I6.Data[32] Lower 16 bits of peak-to-peak current N/A -32767-32767 N/A 15 IR_MAX_PEAK_HI_2 I6.Data[34] Upper 16 bits peak-to-peak current N/A -32767-32767 N/A 16 IR_CREST_2 I6.Data[36] Cresting factor of the RMS reading as % N/A 0-65535 % 17 IR_FREQUENCY_2 I6.Data[38] Frequency of the current (triggers from +- 100 ADC signal) N/A 0-65535 N/A 18 IR_TICK_2 I6.Data[40] MCSs tick to see if it is still runni ng N/A 0-65535 N/A 19 IR_TEMP_2 I6.Data[42] The approximate temperature of the MCS board N/A -40-105 ºC 20 IR_MS_MA_LO_2 I6.Data[44] Lower 16 bits of the instantaneous squared mean current in ma N/A 0-65535 ma^2 21 IR_MS_MA_HI_2 I6.Data[46] Upper 16 bits of the instantaneous squared mean current in ma N/A 0-65535 ma^2 22