Version-E E100930

Similar documents
Version-E Manual

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Table of contents. Table of contents 1. Installation 2. Introduction ( Display, monitor ) 3. Introduction ( Operating elements ) 4

VERTICAL AIR COMPRESSORS

Instruction Manual BA90 Precision Barometer

PRAHER PLC-MP AQUASTAR MANAUL 2009

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

Airbrush Diaphragm Compressor AS06

VERTICAL AIR COMPRESSORS

NIV EAU MATIC ST User Manual Made in Canada

Operation Manual Airbrush Compressor AS196A ARTICLE 34207

Model 6810A Dual Lane Scoreboard Owner s Manual Rev B

Basketball Instructions

Digital Melting Point Apparatus

OMNISPORT 2000 SWIMMING QUICK REFERENCE

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

TdC 8000 Page 1. Version: E Page 1

Scoreboard Operator s Instructions MPC Control

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

5 Channel Calibrator

CAUTION: YOU MUST READ THE FOLLOWING BEFORE OPERATING THE SNOWMAN.

STAGE, STADIUM & X-TREME SHOT.

New AQF Filter Polymer Filtration System

RAM 4021 Operation Manual

700 SERIES BMS II BUBBLER MONITORING SYSTEM

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Model 6812C Dual Lane Scoreboard Owner s Manual

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

Manual. Kingpad mc-32 Edition. Bus system control pad for installation in the Graupner mc-32 transmitter. No Copyright Graupner/SJ GmbH

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

OC Panel High Limit Aquastat Kit, Manual Reset p/n

ECL Comfort 110, application 131 (valid as of software version 2.00)

TdC 8001 Page 2. Version:E Page 2

300C/ 800C/ 990C Plus Series

ALGE Water Polo Scoreboard

CONTROL LOGIC DESCRIPTION DOCUMENT IC-410ND

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no

In Vivo Scientific, LLC INSTRUCTION MANUAL

ALGE SWIM2000. Architectural Guideline ALGE

GasLab SAN-102 Micro Oxygen Monitor User Manual

OptiAir CA09 Pneumaticfluidizing

VX Series Salt Chlorinator T Model

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

Aquavar SOLO 2 Frequently Asked Questions

03/07/2014 V

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Instruction Manual Dräger MSI P7 and MSI P7 plus

ALGE DIVE! ALGE. ALGE-TIMING GmbH & Co

Stand-Alone Bubble Detection System

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

Manufactured by: AAA

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Lil Mix Controller (Order code: LEDJ122)

9A5N Solid State CW Paddle

Model 130M Pneumatic Controller

Electrical operating instructions

Operation Manual Airbrush Compressor AF18-2 ARTICLE 34203

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

PIRANHA I & 2 OPERATION GUIDE

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

IBU3 Manual Addendum 1

Installation, Operation & Maintenance Instructions

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

12V Mini Air Compressor

HAI UPB Wall Switch and Auxiliary Switch Installation and Operating Instructions

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

PERSONAL AIR BREATHING UNIT

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

RAM Operation Manual

USER MANUAL. JET TST and JET TST S.

PS Plasma 375 Plasma Cutter Kit Assembly & Operating Instructions

Scoreboard Operator s Instructions MPCW6 Control

Instruction Manual: VelectriX Ascent 29 MTB

LC-SPE. Organizer 3.0 User Manual. Innovation with Integrity. Version 001 NMR

GasLab SAN-102 Micro Oxygen Monitor User Manual

Laboratory Mortar Mixer (Testing)

SP-110 Autopilot OPERATION

USER MANUAL. All rights reserved

G2W PRO ROBOT. User Manual. paddlepalace.com

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

OPERATING INSTRUCTIONS FOR

Windspeed WS1. English

Instruction Manual MediPrep 120

KERN EG/EW Version /02

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Electrical operating instructions

Instruction Manual: VelectriX Urban 2.0+

TrekMill USER'S MANUAL MM5050

Instruction Manual: VelectriX Foldaway

SPS-5. Rate Computing Scale. Operation Manual

RAM 4021-DPX Operation Manual

Transcription:

Version-E080529 E100930 Football Manual

Important Information General Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information about installation, safety and its intended use. This manual cannot cover all conceivable applications. For further information or in case of problems that are mentioned not at all or not sufficiently detailed, please contact your ALGE-TIMING representative. You can find contact details on our homepage www.alge-timing.com Safety Apart from the information of this manual all general safety and accident prevention regulations of the legislator must be taken into account. The device must only be used by trained persons. The setting-up and installation must only be executed according to the manufacturer s data. Intended Use The device must only be used for its intended applications. Technical modifications and any misuse are prohibited because of the risks involved! ALGE-TIMING is not liable for damages that are caused by improper use or incorrect operation. Power supply The stated voltage on the type plate must correspond to voltage of the power source. Check all connections and plugs before usage. Damaged connection wires must be replaced immediately by an authorized electrician. The device must only be connected to an electric supply that has been installed by an electrician according to IEC 60364-1. Never touch the mains plug with wet hands! Never touch live parts! Cleaning Please clean the outside of the device only with a smooth cloth. Detergents can cause damage. Never submerge in water, never open or clean with wet cloth. The cleaning must not be carried out by hose or high-pressure (risk of short circuits or other damage). Liability Limitations All technical information, data and information for installation and operation correspond to the latest status at time of printing and are made in all conscience considering our past experience and knowledge. Information, pictures and description do not entitle to base any claims. The manufacturer is not liable for damage due to failure to observe the manual, improper use, incorrect repairs, technical modifications, use of unauthorized spare parts. Translations are made in all conscience. We assume no liability for translation mistakes, even if the translation is carried out by us or on our behalf. Disposal If a label is placed on the device showing a crossed out dustbin on wheels (see drawing), the European directive 2002/96/EG applies for this device. Please get informed about the applicable regulations for separate collection of electrical and electronical waste in your country and do not dispose of the old devices as household waste. Correct disposal of old equipment protects the environment and humans against negative consequences! Copyright by ALGE-TIMING GmbH All rights reserved. Any duplication, either in full or in part, requires the prior written consent of the copyright holder. Seite 2

Table of contents 1 Introduction...4 2 Football scoreboard type FB... 4 3 Installation type FB... 5 3.1 How to mount the score board type FB... 6 3.2 Cable Installation... 6 3.2.1 Net cable... 8 3.2.2 Data cable...8 3.2.3 Terminal circuit board (Score Board)... 9 4 FB score board types... 10 5 FA score board types... 11 6 Start-up the Timy... 12 7 Operation of the program... 13 7.1 F0 Game or day time... 13 7.2 F1 Test... 13 7.3 F2 New... 13 7.4 F3 2HA... 13 7.5 Input goals... 13 7.6 CLR button... 14 7.7 More adjustments... 14 7.7.1 TIME... 14 7.7.2 ONLY MINUTES... 14 7.7.3 TIME OUT... 14 7.7.4 TEST... 14 7.7.5 MASK... 15 7.7.6 BOARD... 15 7.7.7 SCORE... 15 7.7.8 AUTO-STOP... 15 8 Trouble shooting... 15 8.1 Self test of the score board... 15 8.2 No function of the score board... 16 The contents of this manual are subject to change without notice! manual copyright by: ALGE-TIMING AUSTRIA Seite 3

1 Introduction There are different types to indicate the results for football FB FA GAZ D-LINE particularly produced for football based on a standard scoreboard standard scoreboard scoreboard with LED technology 2 Football scoreboard type FB The Alge Football Score Board consists of the following parts: Score Board: Timy XE: Cable 206-10: Public information board for football (and athletics) Terminal to control the score board Cable between Timy and connection box in the speaker shack Connection box Connection between the permanent cable from the score board 095 or 096: to the speaker shack and cable 206-10 to the Timy Fastening block: OPTION: Supporting Beam: To fasten the score board on the supporting beams For score board installation Seite 4

3 Installation type FB The supporting beams must be anchored in the ground. We recommend to ask a local static calculation engineer for help. The supportin gbeams must be 100% stabled when you mount the score board. Behind the score board you need 1 meter space, because in case of defects, repairements have to be done from the backside. The supporting beams must be set up in a distance of 2.9 meter. All measurements in the drawing are given in millimetres. We recommend for the supporting beams concrete pipe that is concreted in the natural eaarth. In this pipe you can put the beams, align them, and fill it with gravel. Both supporting beams have a length of 5.5 m ( 1 m inside the ground ). In the picture to the left you can see a cross-section of a supporting beam. The measurements are given in millimetres. Seite 5

3.1 How to mount the score board type FB Mount the score board with the fastening blocks at the support beams. 3.2 Cable Installation Seite 6

Installation in a Stadium in connection with a Athletic Score Board: Football Score Board FL845 Football Score Board FL045 The score board FL845 and FL045 have the possibility to show the running time during an athletic event. The time is shown on six digits in minutes, seconds and 1/100 seconds. You can choose between football and athletic mode with the connection box 096. You can also take the Timy for the athletics. Seite 7

3.2.1 Net cable For the score board you need 230 VAC power supply (cable with minimum 3 x 1,5 mm²). The rules for electric installations must be considered. Never install the data cable and net cable in the same installation pipe. We recommend to call an electrician for this.. 3.2.2 Data cable For the score board you need to install a data cable 4 x 1,0 mm² with maximum length of 200 meters to the speaker shack. An Amphenol-device-plug is mounted at the score board. At the data cable on the score board side you have to munt an Amphenol-cable-socket, on the speech shack side an Amphenol-cable-plug. They are through-wired straight. Cable from the score board to the connection box: Seite 8

3.2.3 Terminal circuit board (Score Board) The electronic is in the white box on the backside of the score board. To install the score board, it s not necessary to open the box. The net cable for the power supply and an Apmhenol-device-plug for the data connection is available from the outside. If you have difficulties with the score board during the installation or operation, control first the fuses and LED. In order to reach the Terminal circuit Board, remove the four screws of the plastic case and lift the cover. Seite 9

4 FB score board types FB645 FB845 FL845 FL045 Seite 10

5 FA score board types FA 445: FA 645-T: FA 645-G: The electronic is on the right side of the score board like a normal GAZ display board. Seite 11

6 Start-up the Timy The TIMY has got a weather-proof (and water-proof) silicone keypad. The keypad is ideal for outdoor-usage. The keys are raised and have ideal pressure points and although the TIMY has got small dimensions, they are easy to operate. Control keys: These keys are used all-purpose. You can always see the function in the display. START/ON: Key for manual start impulse and to switch-on the Timy. STOP/OFF: Key for manual stop impulse and to switch-off the Timy. Printer: Key for paper output. If you press the combination and, you will get into the printer menu. 2nd: This key is always used in combination with a second key (additional function). Menu: Key to enter the device menu CLR: Key to clear the marked times or to clear the memory. Cursor: Keys to move the cursor in the display. + Beginning of a list + End of a list OK green: To confirm the commands, to confirm start inputs or to switch it on. OK red: To confirm the commands, to confirm finish inputs or to switch it off. Seite 12

7 Operation of the program Please read the Timy manual GENERAL how to start the Timy. The Timy and the scoreboard were configured correctly and should function after correct installation of the scoreboard immediately. You can operate a standard score board, D-LINE and the football score board with this program. 7.1 F0 Game or day time With the F0 key you can switch between the game or day time. Always the bigger writing is active. 7.2 F1 Test When you push this button, a automatic display board test will be started. The display board switches between eight and blank. To stop the test, press the F0 button. 7.3 F2 New Here you can input a new game time or a new daytime. 7.4 F3 2HA 2HA = second half time. When you press the F3 button the Timy will ask you: Confirmation second half. Confirm this with Yes (F0 or F1) or with no (F2 or F3). When Yes the Timy switch in the game time mode with a default time of 45 min. 7.5 Input goals You can input the goals in the game or day time mode. The green OK button is for the home goals, the red for the guest goals. You can also input the goals directly. Give in the right goal and confirm it with the right OK button. To count down the goals, press the 2 nd and the red or green OK button. Seite 13

7.6 CLR button When you want to have a blank display board, press the CLR button. In this program you can make further adjustments which you can find like described in point 2.1. 7.7 More adjustments 7.7.1 TIME Here you can adjust if the time count up or down. Also you can enter a new day time. When count down, the next point can adjusted. 7.7.2 ONLY MINUTES Adjustment possibilities are YES or NO. Yes means, when the time starts to count down (e.g. 5 min.) the change of the minute occurred when the Timy display shows 3min 59sec. The Timy will give a beep when the count down is finished. 7.7.3 TIME OUT Adjustment possibility to make a time out or not 7.7.4 TEST Possibility to make a second automatic display board test. Power on test Day time test Day time off Power on test means, each time when you switch on the Timy and you go into the Football program, the Timy will start the display board test which is explained in point 2.7.2. Day time test means, the test starts on a specific day time. To deactivate the tests, go to Day time off and confirm with a ok button. Seite 14

7.7.5 MASK Here you can program the football scoreboards. FB 645 FB 845 FL 845 FL 1045 We recommend to make this not on your one, only by an ALGE representatives. 7.7.6 BOARD Here you can adjust the type and the display mode. GAZ TIMETEMP D-LINE standard display board Football scoreboard LED-scoreboard GAZ4 6xx D-LINE 6xx Production Adjustment 6 DIG H- MM G YES YES 8 DIG 7.7.7 SCORE The adjustments are, at game only or always. AT GAME ONLY means, the score is only in the game time mode visible. ALWAYS means, the score is also in the daytime mode visible. 7.7.8 AUTO-STOP Automatic game time stop after 45 and 90 min. 8 Trouble shooting 8.1 Self test of the score board Switch off the score board Make a short cut on the circuit board between 0V and Taster Switch on the score board Each didgit gets a number Release the short cut Make again the short cut It moves each segment of each digit In order to Stopp the self test switch off the score board and release the short cut. Seite 15

8.2 No function of the score board Check the power supply: Top LED and fourth LED from the top must shine LED does not shine: Did you plug 230 Volt plug Is the net cable to the score board OK Control the fuse of the 230 Volt net Check the fuses of the score board All LED s are shining: Selftest is running. Selftest is not working: Change the main circuit board (CPU) No connection to the score board: Plug the Timy with cable 206-10 directly to the score board Check fuses Make the Selftest Seite 16