FRIALEN Assembly and Operating Instructions. for FRIATOP clamping unit (Top-Loading) FRIATOOLS

Similar documents
ASSEMBLY INSTRUCTION FRIALEN XL LARGE PIPE TECHNIQUE FOR LAYING LARGE PIPES AND RELINING PIPE NETWORKS.

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves

FRIALEN Safety Fittings for House Service and Supply pipings up to d 225. Assembly Instructions

APG001. Application Guide for Gas. T: F: E:

The number of test stands can be adapted to the special requirements.

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

ambiente Installation Guide AmbiScreedboard system more than underfloor Customer: Project: Project Reference: Date:

M03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

OPERATING INSTRUCTIONS

MEGR-1912 Instruction Manual

Float operated valve TYPE (SWDS)

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs

ambiente Installation Guide AmbiPlate more than underfloor Customer: Project: Project Reference: Date:

Materials : Galvanized steel flanges

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

FUSAMATIC MULTISEAL TAPPING TEE STACKLOAD OR UNDERCLAMP FOR GAS AND WATER....Connect

Continental Industries STEEL SERVICE TEES or FAX Visit

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

SEries 29 Hydrant valves installation, operation & maintenance manual

HYDROSTATIC LEAK TEST PROCEDURE

Operation and Maintenance Instructions

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges

with self-sealing gas valve system

OCTOBER 2017 ISSUE Page 1 of 7

ISO INTERNATIONAL STANDARD. Earth-mover tyres and rims Part 3: Rims. Pneumatiques et jantes pour engins de terrassement Partie 3: Jantes

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Torque Specifications

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

K Page 1 of 48 Air Intake - Pg. 17

Bike Rack and Spare Tire Carrier 1-1/4" Receiver

Index Table. Model 794. Installation, Operating and Maintenance Instructions

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Declaration of Conformity as per Directive 97/23/EC

Materials : Electro galvanized steel flanges

REFER TO AQUATHERM TECHNICAL BULLETIN A-AQTTB FOR ADDITIONAL INFORMATION AND SAFETY PRECAUTIONS

GUMMIKOMPENSATOR GKF8000 / GKF8130

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Natural Gas to L.P. Gas Conversion Kit

Pressure Reducing Valve for Steam Type 2333 A

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

Continental Industries TRANSITION FITTINGS or FAX Visit

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Storage Systems and Accessories

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Natural Gas to L.P. Gas Conversion Kit

Type BBS-03, BBS-05, BBS-06, BBS-25

Standard Operating Procedures

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

BICYCLE ASSEMBLY INSTRUCTIONS. dutchcycles.com.au. Distribution Centre

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Siphon vessel / Priming aid

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Model VR6 System. Installation, Operation & Maintenance

CONDITIONS OF SALE AND WARRANTY

HYDRAULIC PUNCH DRIVER 38456, 38520, 7306 / 7306SB, 7310 / 7310SB, 7506, 7606SB, 7610SB, 7625 / 7625Pg / 7625PgSB, 7646 / 7646Pg / 7646PgSB

Budget Range Operators Handbook

RhinoPro Cartridge Gun Manual

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Model MTB-ASME Horizontal Bladder Tanks

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

Two-port valves, male threaded, PN25

USER MANUAL Version: 1/2017

80 Litre Suction Oil Drainer

Operating Procedure TITON SUBSEA BOLT TENSIONER

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

AIR COMPRESSOR MANUAL INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Pressure Limiting Valve SPVF Operating Instructions

Horizontal Bladder Tanks

Installation Instructions and valve Maintenance Rev. 0 of 29/09/15

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Standard Pneumatic Test Procedure Requirements for Piping Systems

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

ISO INTERNATIONAL STANDARD. Earth-mover tyres and rims Part 3: Rims. Pneumatiques et jantes pour engins de terrassement Partie 3: Jantes

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

Materials : Dichromate zinc plated steel flanges

Cylinder Tilt Saddle Instruction Manual

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

This document is a preview generated by EVS

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

CUT OFF TOOL MODEL: CAT113

Pressure relief valve

Installation Instructions

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

30T A/Manual Hydraulic Shop Press

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Transcription:

FRIALEN Assembly and Operating Instructions for FRIATOP clamping unit (Top-Loading) FRIATOOLS

The FRIATOP clamping unit Tensioning belt Top loading component (e. g. tapping ball valve) Adapter Pressure tube Twist grip Housing 2

Index Page 1. Areas of application 3 2. Description of the FRIATOP clamping unit 4 3. Assembling the FRIATOP clamping unit 4 4. FRIALEN fusion 6 5. Removing the FRIATOP clamping unit 6 6. Before drilling through please allow to cool down for the times listed below 7 7. Warranty 7 8. Functional safety 7 9. UPDATES for Assembly Instructions 8 1. Areas of application The FRIATOP clamping unit developed for FRIALEN saddle fittings is pneumatically operated and is suitable for use when fusing on saddle fittings of the special TL type (see illustration on page 2). All the saddles identified as TL types in the latest FRIALEN -price list (e.g. DAA-TL / SA-TL / AKHP-TL / VAM-TL / SPA-TL / VSC-TL) for pipes above 250 mm diameter can be used. Please get the possible applications and dimensions from our price list. When processing the FRIAFIT sewage saddle ASA-TL with pipe d 560, the clamping pressure at the manometer of the air pump may not exceed approx. 2bar. The clamping unit is also suitable for fitting house connection fittings and branch connectors on HD-PE relining pipes (U-liners / C-Liner / Swage lining / Roll down) in conjunction with special FRIALEN relining saddles from DN 100 upwards (on enquiry). 3

2. Description of the FRIATOP clamping unit It consists of four parts: Pneumatic clamping unit Component adapters (2) Air pump 3. Assembling the FRIATOP clamping unit 3.1 The adapter is fitted into the clamping unit before this is tensioned and forms the connection with the FRIALEN component. It has various steps depending on the type of saddle fitting being fused on. If a FRIALEN -SPA- TL is being fused on, the screw cap of the fitting is located directly into the unit without the adapter. The same applies to the VSC-TL. 3.2 Preparation of the area The proper, uninterrupted and uniform scraping of the pipe surface is absolute necessary to prepare for electrofusion welding. Any deviations may result in the joint becoming untight. Please observe the FRIALEN installation instructions for fittings and further manufacturer-specific instructions, if any. 4

3.3 Place the saddle component onto the pipe. Only trained personnel may operate the FRIATOP clamping unit. The operator has responsibility towards third parties within the working area. The operator must make available the operating instructions to the user and must ensure that the user has read and understood the instructions. 3.4 Fit the adapter and the clamping unit onto the saddle component. The different steps in the adapter fit the various types of saddle component. Lay the tensioning belt around the pipe (do not twist!). 3.5 Thread the loose end of the tensioning belt into the rollers on the twist grip. Pull the belt taut by turning the twist grip clockwise. 3.6 Check that the clamping unit is in the untensioned state (no air pressure at the valve) and then connect the air pump to the valve. In the unpressurised state the ten-sioning figures 2_ 1 are visible in the window of the rim of the housing. 3.7 If necessary make a final correction to the seating of the saddle on the pipe. 5

3.8 Pump up the clamping unit (the pressure gauge on the pump should indicate between 3 and 4 bar). The expansion of the cylinder will press the saddle onto the pipe. The gap between the pipe and the saddle must be completely closed by the pressure applied. A visual check must be made by the user! 3.9 In the pressurised state the tension number is read off in the window next to the handle and marked for safety on the piece of pipe. This will give a check on any fall off in pressure during fusion. If this drop in pressure is no greater than one scale graduation then the fusion has been carried out in accordance with the standard. If the pressure drop is greater than this the fusion process must be broken off and the reason investigated. Afterwards, and when the proper cooling time has elapsed, a second fusion can be carried out. 4. FRIALEN fusion Connect the fusion cable from the fusion unit to the contacts on the saddle and start the fusion process. During the fusion process the tension number should be checked. For the sake of general safety always stay at a distance of one meter from the point of fusion during the fusion process. 5. Removing the FRIATOP clamping unit After the fusion has finished always maintain the joint pressure in accordance with 3.8 for a 10 minute cooling period. After this the pressure can be taken off by venting the unit to air and the unit dismantled. 6

6. Before drilling through please allow to cool down for the times listed below Cooling times d 250 - d 560 mm = 60 min for special relining saddles TL/RE > d 98 - d 130 mm = 30 min > d 130 - d 160 mm = 45 min > d 160 - d 220 mm = 60 min > d 245 - d 560 mm = 60 min If the cooling down time is not adhered to the saddle can come away from the pipe in the area of the fused joint. A permanently safe fused joint cannot be guaranteed. 7. Warranty The warranty is 6 months. It will not apply if there are signs of force being used or of usage which is not in accordance with the operating instructions. 8. Functional safety The FRIATOP clamping unit has been checked for safe operation before being shipped. The equipment requires very little maintenance. We recommend a half yearly check on all functional parts. The unit should be protected from dirt. 7

If you have any queries on this information the following will be glad to advise you FRIATEC Aktiengesellschaft Technical Plastics Division Technical Equipment Steinzeugstraße 50 D-68229 Mannheim Tel. +49/(0)621/486-2335 Please request list of service points worldwide from our service hotline on +49 621 486 1533. 9. UPDATES for Assembly Instructions These technical statements are checked regularly in terms of up-to dateness. The date of the recent revision is specified on the document. Visit www.friatools.com, in the left navigation menu you will find the submenu Downloads. Here you will be able to read and even print out up-to-date operating instructions (pdf file). We also would be pleased to send them to you. FRIATEC Aktiengesellschaft Technical Plastics Division P.O.B. 710261 D-68222 Mannheim Telephone +49 621 486-0 Telefax +49 621 486-2030 Internet: www.friatec.de e-mail: info-geraetetechnik@friatec.de 1775/2e IV.08 Update: 24.01.2008