EC 49.0xx.226. Control port. Applications

Similar documents
Tm: 65 C (149 F) max. Tm: 65 C (149 F) max. Tm: 65 C (149 F) max. Tm: 65 C (149 F) max. Tm: 90 C (194 F) max. Tm: 98 C (208 F) max.

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

ACCREDITED. Technical specifications series

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Pressure Reducing Valve DMV 750

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

2/2-Way Solenoid Control Valve

Installation and operating instructions KEMPER Backflow Preventer BA Figure 361

Pressure Reducing Valve DMV 750 set range: bar

Pressure Relief Valve DHV 718

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Proportional Throttle Cartridges, Size 16

Type 4708 Supply Pressure Regulator

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

Self-operated Pressure Regulators for special applications

RR 16 Commercial & Industrial Regulator

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version


Direct Operated Precision Regulator Modular Style. Standard Specifications

Safety Shut-off Valve SSV

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Tubes Components Valves Units Engineering SO EVERYTHING KEEPS FLOWING. Safety valves Bunging valves Vacuum valves Tank dome fittings

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Materials : Brass body dezincification-resistant up to DN1 1/4

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Seated valves VRB 3, VRG 3

Inverse Proportional Pressure-Relief Cart., Size 2 4

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Operating instructions - Translation of the original -

BERMAD Waterworks. Combination Air Valve. Air Valves Series. Typical Applications. Features & Benefits. Additional Features.

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

Pressure relief valve DHV 718

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Engineering Data Sheet

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Pressure Reducing Valve DMV 755

Installation and Operating Instructions Bypass Flow Meter DST

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Pressure Reducing Valve for Steam Type 2333 A

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

OPERATING INSTRUCTIONS

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

STAINLESS STEEL OVERFLOW VALVE TYPE 417

Materials : Brass body dezincification-resistant

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

RTG 25. Introduction

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

CAST IRON SAFETY VALVE TYPE 6301

GESTRA Steam Systems BK 45 BK 45U BK 46. English. Installation Instructions Steam Traps BK 45, BK 45U, BK 46

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Materials : Stainless steel ASTM A351 CF8M

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Proportional Pressure-Relief Cartridge Valve, Size 2...4

GESTRA. GESTRA Steam Systems CB 1... CB 2... Installation Instructions Swing Flap Non-Return Valves CB 1..., CB 2...

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Safety and Shut-off Block SAF/DSV

Mass Flow Controller (MFC) for Gases

Installation, commissioning and servicing instructions

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Pressure independent control valve (PICV) FLOWMATIC

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Mass Flow Controller (MFC) for Gases

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

KSB Delta Compact Type Series Booklet

Inverse Proportional Pressure-Relief Cartridge, Size 10

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

InnovDos Foam proportioning system

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

InnoVfoam B.V. InnovDos Foam Proportioning System

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Pressure regulator for water

Steam Trap BK BK 212-ASME. Original Installation Instructions English

3-Way Safety Block DSV

3-Way Pressure-Reducing Cartridge, Size 2 4

776 Cryogenic Safety Valve

Transcription:

Solenoid valves Ctrol valves Special valves and systems GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany Tel.: +49(0)211-7391-0 Fax: +49(0)211-7391-281 e-mail: info@akmueller.de Internet: www.akmueller.de Ctrol port Descripti Ctrol port Pressure fluctuatis in a water distributi circuit can cause a reversal of the flow directi. In this case a check valves, installed between the water distributi system and the mains water supply, closes automatically and prevents any back flow, back sucti or back pressure. The inspecti openings provided before each backflow preventer unit, allow a regular mitoring of the safe functiing of the compent. The series 49.0xx.x26, verifiable check valves, types EA and EC, is developed according to the performance requirements of DIN EN 13959 and are cfirmed by an accredited laboratory. These are suitable, according to DIN EN 1717, for securing devices using category 1 and 2 liquids (according to WRAS the EC type is also applicable to fluid category 3). Also check valves protect sensitive equipment from ctaminati from backflow (e.g. behind pumps), dry running through retenti of water (e.g. before not self-priming pumps), cross flow in systems with varying line pressure (e.g. in parallel cold and hot water supplies ) and ensure the flow in ly e directi in complex fluidic systems. The verifiability offers the user the possibility of checking the operatial reliability and can, optially, be equipped with a manometer or other sensors. Various cfiguratis by combining different nominal orifice sizes and fluid cnectors are available. Ctrol port EC 49.0xx.226 Applicatis Use in devices with direct cnecti to the drinking water supplies Commercial cooking devices Steam cooker Pressure cooking devices Water cooling equipment (e.g. X-ray equipment) Drink vending machines (coffee, juices) Water dispensers Avoiding of back flowing medium in the drinking water supply where backflow preventer according to DIN EN 1717 Type EA and EC is allowed (fluid category 2). Verifiable single check valve Verifiable double check valve EA EC Possible approvals Approved versis available : KTW/W270 Others Characteristics Safety device against backflow or back sucti of liquids, e.g. in potable water networks Suitable for fluid categories 1 and 2 in accordance to DIN EN 1717 Available in DN 8, 10 or 12 depending port size Medium temperature 65 C/149 F (90 C/ 194 F for max. 1 h) Compact design Easy to retrofit Functi in accordance to DIN EN 13959, cfirmed by an accredited laboratory Easy maintenance through ctrol ports with G 1/4 plugs (Tightening torque 1-1,5 Nm) Manifold cfigurati optis by combining various nominal widths and fluid cnectors Fluid cnectors optial as female and male threads available Type Cstructi Functi Fitting positi Media Housing Internal n-return cartridge housing Seal Spring Sealings Plug of ctrol port N-return valve (check valve) Check valve cartridge in housing Backflow preventi Any T-Medium 65 90 Technical Data cold and heated potable water and physically and chemically similar media Materials PA 6/6 glass fibre reinforced POM VMQ stainless steel EPDM C max. C max. for 1 h T-Ambient 65 C max. DN 8, 10 or 12 mm depending port size p-operating 0-10 bar Ctrol port G 1/4 PA 6/6 glass fibre reinforced, stainless steel 1

095400 G 3/4 10,5 12 G 3/4 17,5 29,0 27,5 56,5 28,5 46 24 095401 G 1/2 9,5 10 G 1/2 14,5 30,0 24,5 54,5 28,5 43,5 21 095402 G 3/8 7,7 8 G 3/8 12,5 27,0 22,5 49,5 28,5 43,5 15 2

Further variants G 3/4 10,5 12 24 10 G 3/4 10,5 29,0 29,0 58 28,5 46 21 G 1/2 9,5 8 G 1/2 9,5 30,0 30,0 60 28,5 43,5 15 G 3/8 7,7 8 G 3/8 7,7 27,0 27,0 54 28,5 43,5 15 3

10 21 G 3/4 10,5 G 3/4 17,5 29,0 27,5 56,5 28,5 46 G 1/2 9,5 8 G 1/2 14,5 30,0 24,5 54,5 28,5 43,5 15 4

G 3/4 17,5 12 24 10 G 3/4 17,5 27,5 27,5 55 28,5 43,5 21 G 1/2 14,5 8 G 1/2 14,5 24,5 24,5 49 28,5 43,5 15 G 3/8 12,5 8 G 3/8 12,5 22,5 22,5 45 28,5 43,5 15 5

EC 49.0xx.226 95450 12 24 G 3/4 10,5 10 G 3/4 17,5 29,0 27,5 113 28,5 46 21 95451 10 21 G 1/2 9,5 G 1/2 14,5 30,0 24,5 109 28,5 43,5 Furthermore, the nominal orifice DN 6 can be offered for all valve body variants. 6

EC 49.0xx.226 95452 G 3/8 7,5 8 G 3/8 12,5 27,0 22,5 99 28 43 15 7

Installati guidelines The installati of the backflow preventer is to be carried out in a horiztal pipeline with the ctrol port downwards. In this mounting positi optimal emptying for inspecti is ensured. It is important to ensure good accessibility for the periodic inspecti and maintenance. Tighten the uni nut evenly by hand ly and do not over - tighten it mechanically. After the installati of the backflow preventer, the tightness should be checked. In additi, a shut-off device (e.g. shut-off valve series 52.009.199/~200) should be provided to ensure the devices can be safely checked. Maintenance instructis Backflow preventer are dynamic compents and therefore subject to wear. In accordance with DIN EN 806-5: 2012, backflow preventer of the type EA or EC are to be maintenanced by a regular annual inspecti. Please also take individual natial regulatis into csiderati. Inspecti During inspecti the following points should be checked: The use of the drain-side water has not been changed and the backflow preventer is still suitable for the security of supply Cleanliness around No leakage, corrosi or damage Meets Installati Requirements Accessibility Maintenance For maintenance the following steps in the order of listing should be carried out: Close the shut-off device and make sure that no flow occurs. Therefore close the extracti points, but ensure that the downstream line is under pressure. Open the inlet-side ctrol port, it will leak water until the upstream line is fully drained. After emptying the flow must stop. If not, the tightness of the shut-off device is to be checked and, if necessary repaired. In case dropping occurs or the water runs cstantly, the backflow preventer needs to be replaced. The replacement should be de by an installati company. Close ctrol port again and open upstream shut-off valves to take your device into operati. Combinati of verifiable check valve with shut-off valve, series 52.009.100/~200 8