The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Similar documents
HumiSys HF High Flow RH Generator

Bubble Point / Pressure Decay Test / Gas Transport Rates through Membranes

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Pneumatic high-pressure controller Model CPC7000

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

Pneumatic high-pressure controller Model CPC7000

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

BUBBLER CONTROL SYSTEM

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

Complete Range of Force Tensiometers


PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Overview. Front Panel: Keypad and Display

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Additel 761 Automated Pressure Calibrators Selection Guide

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Additel 761 Automated Pressure Calibrators

FPG8601 Force Balanced Piston Gauge

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

NEW: CO2 incubator with sterilizable sensor

Additel 761 Automated Pressure Calibrators

AUTOMATIC HOSE TEST UNIT, TYPE SPU

FAS-W. Features. Applications. Automatic condensation hygrometer

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

NEW: CO2 incubator with sterilizable sensor

Autocalibration Systems For In Situ Oxygen Analyzers

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

BUBBLER CONTROL SYSTEM

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

Operating Instructions Part No

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

ADT 761 Automated Pressure Calibrator

PRC CO ² -LASER PRESENTATION

Best Practice Guide, Servomex 2700

UNDERSTANDING, ACCELERATED

Additel 780 Series Pressure Controller

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

The Discussion of this exercise covers the following points:

Autocalibration Systems for In Situ Oxygen Analyzers

Digital deadweight tester Model CPD8500

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

FTC130 Transmitter. Operating Manual

CO2 incubator with additional process controls

sorting solutions osx separator series

In Vivo Scientific, LLC INSTRUCTION MANUAL

Your local gas generation partner. Precision series Modular gas generation solution for GC.

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

Thermo Scientific Model 146i Principle of Operation

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Additel 780 Series Pressure Controller

Operating Instructions Part No

Pressure Calibrators. Series PC..., PM...

Hand-held pressure calibrator with integrated pump Model CPH6600

PMI ADVANCED AUTOMATED HYDRAULIC PRESSURE LEAK TESTER APCS-H-60K. Not just Products... Solutions!

User s Guide. Pressure Controller for liquid delivery systems

Touch Screen Guide. OG-1500 and OG Part # T011

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Industrial pressure controller Model CPC4000

Hovacal DATASHEET JUNHO 2013

Quadruple mass spectrometers (transducer type)

Precision pressure sensor Basic version Model CPT6020

UNIVERSAL MASK TEST SYSTEM

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

High-speed pressure sensor Model CPT6140

UltraLo 1800 Alpha Particle Counter

Pressure calibration. 20

PG9607 Piston Gauge. Automated primary pressure reference for absolute and gauge pressures to 500 kpa

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Automatic Isokinetic Sampler. ST5 Evo

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

CO2 incubator with additional process controls

Installing a Probe. Typical Installation

Customer Responsibilities

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Constant Pressure Inlet (CCN) Operator Manual

Series Environmental Chambers

Digital dead-weight tester Model CPD8500

Markes Thermal Desorption Systems Site Preparation Page 1 of 8

AIR-X COMPACT AIR-X ON-LINE LUBRICANT AERATION MEASUREMENT. Technical Brochure ON RUNNING ENGINES

Recirculating Coolers

Long term stability tests of INO RPC prototypes

Discovery HP-TGA 75/750. Site Preparation Guide

Industrial pressure controller Model CPC4000

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

Major Design Features

Transcription:

The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is a versatile, precise, and cost effective water vapor generation and calibration system for low flow rates (up to 500 cc/min) applications. Fast response, wide flow range, ability to collect data from variety of sensors, fully automatic and manual operation make it ideally suited for a wide variety of applications requiring an accurate and stable source of water vapor. Its modular design, ability to work in different hardware configurations, ability of user-implemented control using a simple command language, and versatility of the supplied operational software allow easy integration into a larger analytical setup or interfacing with other devices. The HumiSys uses two mass flow controllers to generate fast, stable, and repeatable RH values from 0 to 100% at temperatures up to 90 C. Typically the system is supplied with one RH probe and external temperature probe. Second RH probe can be used for monitoring purposes. A precision pressure regulator isolates the selectable flow rate from fluctuations in the supply line. An automatic water supply system eliminates frequent user intervention inherent to other generators. The generated water vapor stream is delivered to the location of choice via flexible heated transfer line (standard equipment). Applications Programmable RH source for: - Providing RH option to other analytical instruments: Gravimetric sorption analyzers, DMA, TGA, X-Ray Diffractometers, WVTR measurement instrumentation, etc. - High stability RH source - Relative humidity sensors calibration, troubleshooting system for sample chamber designs - Sample conditioning in specialized instrumentation, maintenance of precise RH in variety of industrial chambers Operation A dry or semi-dry gas source is connected at the instrument back using 1/8 OD tubing. Typically, the gas source can be air generated from oil-less compressor or inert gas from a gas cylinder. The dryness of the gas will affect the lowest achievable RH values. The gas pressure regulator allows selection of the desired pressure and observing it on the gauge (front panel). The gas flow can be divided into two branches. The gas portion flowing through the WET valve and mass flow controller (MFC1) enters the saturator where it becomes saturated with water vapors. After passing through the saturator, the humidified gas mixes with the gas flowing through the DRY valve and MFC2 in the mixing manifold. The humidified stream passes through the RH probe port and is redirected to the outlet port to which a heated transfer hose is normally connected. Internal connection of the hose ensures no condensation for high temperature operations. Automatic temperature control and available different sizes and lengths of the hose make interfacing very easy.

GAS SUPPLY VAPOR GENERATION "DRY" MFC2 GAUGE TRANSFER LINE VAPOR GAS "WET" MFC1 RH PROBE PRESSURE REGULATOR WATER SUPPLY LEVEL INDICATOR LEVEL SENSOR SATURATOR WATER PUMP WATER PREHEATER A high quality miniature, high temperature RH probe is employed to sense the amount of moisture in the mixed gas. The gas flow ratio is adjusted as needed to achieve the desired RH value. From the manifold the output stream is delivered via the heated transfer line to the location of choice. The temperature of the transfer line is automatically maintained at saturator temperature by a special controller board. No additional external controller is needed. The water used for gas saturation should be de-ionized and of high purity to avoid contamination of the high surface media in the saturator and to minimize maintenance. The autonomous water delivery system consists of peristaltic pump and its controller, water level sensor, visual level indicator, pump enable switch (ON/OFF), and pump direction switch (Forward/Reverse) located at the back. When water level drops below certain level, the pump is activated and it supplies enough water to restore the required level. This amount of water is preheated to the saturator temperature to avoid any temperature drops in the saturator chamber. If automatic refill action is temporarily not desired, the pump enable switch can be turned off. In a case the water has to be removed from the system, e.g. for shipping purposes, the pump direction switch has to be switched to the REV position until the water is emptied. RH Control Modes Two basic modes can be used to provide RH control to the user defined location: Mode 1. The RH probe used for RH control can be placed inside the user chamber (in a representative place near sample) Mode 2. The RH probe used for control can be placed inside the RH generator and external temperature probe can be used for temperature monitoring of the user chamber. The (optional) additional RH probe can be used for RH and temperature monitoring at any place. Additional modes and application specific sensors can be provided for customized units.

Auto and Manual Control The HumiSys features Automatic and Manual mode of operation. The Manual mode was added to provide fast setup for turn-key operation. Saturator temperature, states of solenoids, voltages for MFC control are settable from the front panel controls. The resulting RH and temperature can be viewed on the LCD display. Windows based operational software is provided for automatic RH control (standard equipment). To facilitate interfacing with other instruments, an external voltage signal to start the software can be used. Microcontroller board and ancillary electronics opens many possibilities for implementation of automatic operation of the instrument and interfacing to external hardware. From an OEM user point of view, the analog and digital resources of the microcontroller board add the convenience of relinquishing any master controller from providing them. To ensure modular and open-architecture approach to design of control HUMISYS RH GENERATOR USER CHAMBER GAS RH Probe (Relocatable, inside or outside of the instrument) TRANSFER LINE VAPOR RH probe (Relocatable, inside or ouside of instrument) WATER USB or COM Port CPU Command Language Temperature Probe 2 (RTD2) Auxiliary RH Probe (monitoring) User custom Software & CONTROLLER HUMISYS Software PC (Windows) Dew Point Analyzer system, a command language was developed to control the instrument via serial port. A USB to serial port converter can be easily added to utilize a computer USB port if a serial port is not available. Different optional sensors can be attached to the instrument and their data can be transferred to a master controller. Using these commands, versatile PC software for experiment design, control, and interfacing to external sensor(s) has been developed. Direct control via serial port using command language To allow OEM users direct control over the instrument hardware but without the need of knowing details of complex electronics, the following strategy is employed. Monitoring or changing each resource, like A/D and D/A channels or digital ports, is carried out by issuing a simple command via serial port. Command handlers written in the firmware software carry out requested tasks. Single-wire data transfer protocol for some digital RH probes (16-bit resolution) from Rotronic Instrument Corp. is also implemented. Basically, the instrument with any external hardware (sensors) connected to it can be perceived as a black box that can be easily operated using a simple set of commands. For example, the Diagnostics screen in the

provided PC software will report the entire state of the system with one simple command: rs,. Please see a portion of the screen below. Experiment design and control using Windows based PC software User friendly software for execution of different RH steps, diagnostics, calibration, graphing, reporting, and RH calculations has been designed. Automation of templates design, flexibility in experiment modification during run, and ability to switch between Auto and Manual operation are very useful in any research work. A snapshot of the template design screen is presented below.

The instrument can be equipped with different hardware configurations and it can be used as a calibrator or generator. Depending on which sensor is currently used for determining the final RH, one of several modes of operation can be selected. The system can be easily accommodated to different RH needs by user. Specifications RH range: 0 to 100 % RH resolution: 1/264 % (RH probe) Temperature resolution: 1/264 C (RH probe) RH accuracy: RH probe sensor dependent (±1%, ±1.5%) Maximum temperature of saturator: 90 C Dew Point: Using RH probe for dew points above 80 C is not recommended. Thermal protection: Thermal cut-off for the saturator heater. Temperature limit is also set in the temperature controller. Flow Rate: Determined by the MFC range, Available ranges for standard unit: 50, 100, 200, 500 cc/min. For higher flow rates please review the high flow version of the instrument (HumiSys HF) Gas Type: Inert gas, typically air or N 2 Gas Inlet Port: 1/8 (Swagelok type bulkhead) Gas Inlet Pressure: Maximum: 20 bar (300 psi) Minimum: 0.7 bar (10 psi) Internal Output port: 0.25 (6.35 mm) OD tubing (the compression fitting can be easily replaced to accommodate other sizes). Transfer line dimensions: Heated length about typically 1 m (40 ) Inner tube: 0.25 OD; 3/16 or 1/8 ID (6mm OD, 4 mm ID, optional) Thickness w/ insulation: about 19-20 mm (0.8 ) Other lengths and sizes available as options Transfer Line Temperature: Maximum (Continuous) 100 C Minimum: Ambient Dimensions: (W x H x D) (22.3 cm x 29.2 cm x 40.6 cm) (8.75 x 11.5 x 16 ) (Not including protrusions in front and back) Instrument Weight: 13 kg (28 lb) Power Requirements: 100-120 VAC, 300VA, 60 Hz nominal or: 220-240 VAC, 300VA, 50 Hz nominal These specifications are subject to change at any time Windows is a reg. trademark of Microsoft Corporation Swagelok is a reg. trademark of Swagelok Corporation P.O. Box 970366 Coconut Creek, FL 33097 Ph: (561) 271-1958 Fax: (561) 477-8021 Website: www.instruquest.com E-mail: info@instruquest.com