ABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators

Similar documents
AK100 Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

ABB Kent-Taylor. Instruction Manual. Model 6553 Series Gas Analyzer Systems for Intrinsically Safe Hydrogen & Purge Gas Purity Measurement

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Supplementary Operator s Manual 42/24-14 EN Rev. 3

MODEL GENERA PURGE TURBINE INSTR DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

Best Practice Guide, Servomex 2700

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Micro Motion 3098 Gas Specific Gravity Meter

ABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

High-performance submersible pressure transmitter For level measurement Model LH-20

Zirconia Oxygen Analyzer Systems

Pneumatic high-pressure controller Model CPC7000

AMT-Ex Dewpoint Transmitter

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

High-performance submersible pressure transmitter For level measurement Model LH-20

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

SITRANS P measuring instruments for pressure

9700 Transmitter Submersible hydrostatic level transmitter

Gas density monitor With integrated transmitter Model GDM-100-TI

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

C-Flow Coriolis Mass Flow Meters

Service Calibration are you doing it properly?

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

2600T Series Pressure Transmitters Calibration Frequency Determination

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

[Instruments for vacuum measurement, checking and adjustment] 3

Installation, operating and maintenance Instructions for Seemag bypass level indicator

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Expert Hydrostatic Level Transmitters

Pressure Measurement Single-range transmitters for general applications

Navigator 500 Dissolved oxygen analyzer. Measurement made easy. Accurate and reliable measurement of dissolved oxygen in high purity water

Instruction Manual Differential Pressure Transmitter

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Level switches Series LD Vibrating fork level switch for liquids and solids

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

High-performance submersible pressure transmitter For level measurement Model LH-20

780S Ultra High Purity Series

Level switches Series LD Vibrating fork level switch for liquids and solids

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

Glass tube flowmeters Series 2000

Pneumatic high-pressure controller Model CPC7000

Navigator 600 Silica analyzers

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Series Environmental Chambers

NGN Series nitrogen generator

Columbus Instruments

FLAMMABLE GAS SENSOR/TRANSMITTER

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pressure measurement Applying remote seal, isolation diaphragms between process fluids and transmitters

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Ultra High Purity Model 780S

Features. Description

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Autocalibration Systems For In Situ Oxygen Analyzers

FAS-W. Features. Applications. Automatic condensation hygrometer

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

SSL. Smart Valve Positioner.

Design Features. General Description

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Micro Motion 7812 Fiscal Gas Density Meter

Technical Information

LFE OEM TCD - Thermal Conductivity Detector

BUBBLER CONTROL SYSTEM

SERVOTOUGH Oxy (1900)

Measurement of Low GAS & Liquid Flows

Level transmitter LT 100

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

MEDICAL EQUIPMENT CATALOG

AMS 2710 PCB pressure sensor module with V output

FTC130 Transmitter. Operating Manual

Endura AZ40 Transmitter Main board spares kit

Model 130M Pneumatic Controller

Pressure Measurement Single-range transmitters for general applications

Pressure transmitters EMP 2

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

ATS430 turbidity sensor Retractable insertion assembly

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

The Ins and Outs of I/P Transducers

Powers Controls RC 195 Multiple Input Receiver- Controller

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Transcription:

ABB MEASUREMENT & ANALYTICS DATA SHEET AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators

AK100 S E RIE S ATEX COMP LI AN T GAS ANALY ZE R SYSTE M DS/AK100-E N RE V. O Measurement made easy Superior technology and quality from the world leader in hydrogen measurement ATEX compliant Intrinsically safe to II (1)G EN60079 0 & 11 compliant Safety Early warning of hazardous hydrogen / air mixtures Cost savings Maintenance of hydrogen purity ensures efficient cooling of the alternator to optimize plant performance Choice Separate display units for hydrogen purity and purge gas for ease of use and duplicate systems for enhanced security Low cost of ownership No moving parts and just one consumable item ensure minimal maintenance and running costs Confidence ABB has over 80 years experience of katharometer design and operation

AK100 SERIES ATEX COMPLIANT GAS ANALYZER SYSTEM DS/AK100-EN REV. O 3 General The AK10x range of instruments is designed to provide reliable and accurate hydrogen purity and purge gas measurement to ensure the safe and efficient operation of hydrogen cooled turbo-generators. Hydrogen purity Modern high capacity turbo-generators need to be cooled efficiently. Hydrogen, with a thermal conductivity of about seven times that of air, is in general use as the coolant. Any drop in hydrogen purity during operation of the machine has two adverse effects: The first, and most important, is to compromise the safe operation of the generator. Accurate measurement of hydrogen purity is essential to provide an early warning of a potentially explosive mixture of hydrogen and air. The second is the economic impact of reduced efficiency. To increase plant performance and control generating cost per megawatt, turbine generators must perform with optimum efficiency. A drop in hydrogen purity causes additional windage losses and consequently reduces generator efficiency. Purge gas To complete the system the AK10x series also incorporates a purge gas analyzer. During commissioning and de-commissioning of a system it is essential that the hydrogen is safely introduced and removed from the turbo-generator. To avoid an explosive mixture of air and hydrogen during commissioning, air must first be purged from the system by an inert gas; carbon dioxide is in common use for this purpose although argon or nitrogen are gaining popularity. The hydrogen coolant is then introduced and replaces the purge gas. To de-commission the turbo-generator the purge sequence is reversed. 4,500 4,000 3,500 800 MW unit 400 MW unit Financial loss, $US/day 3,000,500,000 1,500 1,000 500 0 100 99 98 97 96 95 94 93 9 91 % hydrogen purity Typical cost of decreased hydrogen purity

4 AK100 SERIES ATEX COMPLIANT GAS ANALYZER SYSTEM DS/AK100-EN REV. O Katharometer Principle of operation The AK10x range of gas analyzers utilize thermal conductivity as its principle for measurement. When a constant current is passed through an electrical conductor surrounded by gas in a chamber, the temperature rises to a point of thermal equilibrium. Provided radiation, convection and end-conduction losses are minimized, the temperature of the conductor depends upon the heat loss by conduction through the gas. The temperature attained is therefore related to the thermal conductivity of the surrounding gas and hence the resistance of the wire is a function of the thermal conductivity. The katharometer comprises a wheatstone bridge, each arm of which contains a fine, glass-coated, platinum wire. One pair of parallel arms is sealed in a reference gas of known thermal conductivity and the other pair is exposed to the sample gas. A constant current is passed through the bridge network. Any difference between the thermal conductivities of the reference and sample gases causes an imbalance of the bridge. This imbalance is a function of the difference in thermal conductivities of the two gases so the analyzer can be calibrated directly in terms of the percentage of one gas to another. Product description A complete system comprises: Display monitor One (or two) gas analysis panels One (or two) power supply units Zener barrier devices Zener barrier devices are included in the display monitor enclosure to prevent any dangerous electrical feedback from the transmitters to the hazardous area. Power supply The 434 power supply units provide the analyzer assemblies with an intrinsically safe, stable constant current. These power units must be installed in a safe area but the current output from them may be transmitted to the katharometers in the hazardous area. Gas analysis panel Gas analysis assemblies, 6540 (low pressure variant) and 6548 (high pressure variant) are fitted with a thermally lagged katharometer, a needle flow-control valve, a flow gauge and a drying chamber. Sample gas low-flow alarms (Only available when system is ordered complete with cubicle) Optional intrinsically safe, sample-gas low-flow alarms can be fitted in the Cubicle and connected to the sample gas flow meter. These are used to warn operators of leaks or blockages in the sample line. Display monitor The 6553 display monitor includes one or two 4689 digital transmitters, the range selector switch (excluding AK104), katharometer remote zero adjustment control and zener diode safety barriers. Digital transmitters The 4600 series universal transmitter provides the operator interface and communication to other devices. The signal from the sensing system is converted by the transmitter and the measurement is presented on a large, easy-to read, backlit liquid crystal display. This display is used in conjunction with the four tactile membrane keypads to prompt the user through the programming procedures. The transmitter is fitted with two-step alarms for falling hydrogen purity.

AK100 SERIES ATEX COMPLIANT GAS ANALYZER SYSTEM DS/AK100-EN REV. O 5 AK101 hydrogen purity and purge gas analyzer Industry standard version comprising: Two gas analysis panels, the first measuring hydrogen purity and the second measuring the two purge gas ranges. Two power supply units. One display monitor containing two digital transmitters. The upper transmitter displays hydrogen purity and the lower transmitter displays the two purge gas ranges. The range selector switch controls the range to be displayed and deactivates the unused transmitter display as appropriate. AK10 dual 3-range analyzer 100 % redundancy and validation version comprising: Two gas analysis panels each measuring hydrogen purity plus the purge gas ranges. Two power supply units. One display monitor containing two digital transmitters. Both the upper and the lower digital transmitters display the hydrogen purity range and the two purge gas ranges. Each digital transmitter has its own range selector switch to control the range to be displayed. AK103 single 3-range analyzer Simple solution for purity and purge measurement comprising: One gas analysis panel measuring hydrogen purity plus the purge gas ranges. One power supply. One display monitor containing one digital transmitter that displays the hydrogen purity range and the purge gas ranges. The range selector switch controls the range to be displayed. AK104 hydrogen purity analyzer Single range version comprising: One gas analysis panel measuring hydrogen purity. One power supply unit. One display monitor containing a single digital transmitter that displays hydrogen purity. Designed for applications where the purge gas cycle is controlled by other means and measurement of purge gas is not required. Operating range Range for hydrogen purity: 85 to 100 % H 80 to 100 % H user selectable Range for purge gas: 0 to 100 % hydrogen in purge gas * 0 to 100 % air in purge gas * Alternative range for hydrogen purity: 100 % to 85 % H 100 % to 80 % H user selectable (does not conform to ATEX directive) * Carbon dioxide standard; argon or nitrogen also available. Cubicles When simplified installation is required, the 6553 display monitor and 434 power supplies can be supplied in a wall-mount enclosure. Access to select ranges and program the 4689 display units is via the enclosure s glass panel door. The rear hinged section houses the power supply units and the optional flow alarm relays and miniature circuit breakers (MCBs). Analyzer panels The analyzer panels are available with options for use on low pressure or high pressure, gas sample systems (see system diagrams following). The 6540 03 panels are suitable only for use on systems where the gas sample is vented to atmosphere and the pressure in the analyzer panel is therefore only marginally above atmospheric pressure (1 bar absolute). For applications where the gas sample may be returned to the generator cooling system at an elevated pressure, the 6548-000 analyzer panel must be used. This panel is equipped with fittings suitable for such duties and is pressure tested to 10 bar (gauge). Note. As no certification exists for measurements at pressures above 1bar absolute (nominal), it must be understood that the stated I.S. certification does not cover use at higher pressures.

6 AK100 SERIES ATEX COMPLIANT GAS ANALYZER SYSTEM DS/AK100-EN REV. O Analyzer panels Hazardous area Analyzer panel (6540 or 6548) Power supply units (434) Safe area 115 or 30 V AC 80 or 85 % to 100 % in air L N E Monitor (6553) Analyzer panel (6540 or 6548) L N E 4689 indicator 4689 indicator 0 to 100 % H in purge gas * 0 to 100 % air in purge gas * 115 or 30 V AC AK101 purity and purge gas analyzer system Hazardous area Analyzer panel (6540 or 6548) Power supply units (434) Safe area 115 or 30 V AC 80 or 85 % to 100 % in air 0 to 100 % H in purge gas * 0 to 100 % air in purge gas * L N E Monitor (6553) Analyzer panel (6540 or 6548) L N E 4689 indicator 4689 indicator 80 or 85 % to 100 % in air 0 to 100 % H in purge gas * 0 to 100 % air in purge gas * 115 or 30 V AC AK10 dual 3-range analyzer system * Carbon dioxide standard; argon or nitrogen also available

AK100 SERIES ATEX COMPLIANT GAS ANALYZER SYSTEM DS/AK100-EN REV. O 7 Hazardous area Analyzer panel (6540 or 6548) Safe area Power supply units (434) 115 or 30 V AC 80 or 85 % to 100 % in air 0 to 100 % H in purge gas * 0 to 100 % air in purge gas * L N E 4689 indicator Monitor (6553) 115 or 30 V AC AK103 single 3-range analyzer system Hazardous area Analyzer panel (6540 or 6548) Safe area Power supply units (434) 115 or 30 V AC 80 or 85 % to 100 % in air L N E Monitor (6553) 4689 indicator 115 or 30 V AC AK104 hydrogen purity analyzer * Carbon dioxide standard; argon or nitrogen also available

8 AK100 SERIES ATEX COMPLIANT GAS ANALYZER SYSTEM DS/AK100-EN REV. O Low and high pressure systems The schematic diagrams below show typical arrangements, identifying the types of low or high pressure gas analyzer panels. Tapping point Pressure regulator 0.3 to 0.5 bar outlet pressure Sample filters H purity analyzer panel (6540-03) Note. All valves except * fully open during operations Normally closed * Purge gas analyzer panel (6540-03) Sample to vent Low pressure system sample vented Tapping point H purity analyzer panel (6548-000) Sample filters Note. All valves except * fully open during operations Normally closed * Purge gas analyzer panel (6548-000) Sample return to generator High pressure system sample non-vented

AK100 SERIES ATEX COMPLIANT GAS ANALYZER SYSTEM DS/AK100-EN REV. O 9 Specification 6553 gas monitor Approvals CENELEC approved [Ex ia Ga] IIC ( 0 C Ta +40 C) BASEEFA Certificate No. BAS 01 ATEX 7043 II (1)G EN61010-1:010 compliant Ranges 80 % or 85 % to 100 % H in air 0 to 100 % H in purge gas * 0 to 100 % air in purge gas * Range selector switch positions (when fitted) 1 percentage by volume, hydrogen in air percentage by volume, hydrogen in purge gas * 3 percentage by volume, air in purge gas * Accuracy (display units) ± 0.5 % of scale span Ambient temperature range 0 to 40 C (3 to 104 F) Power supply 110/10V AC or 00/0/40V AC, 50/60Hz (two separate versions) Fuse rating F1 / F 500 ma, 50 V AC rated 1500 A @ 50 V AC, HRC, ceramic, fast blow Power consumption 30 VA approximately Outline dimensions 90 x 36 x 7 mm (11.4 x 14.5 x 10.9 in.) Weight 1 kg (6.4 lb) Environment Sheltered interior, 0 to 90 % RH Outputs and set points No. of relays AK101 3 ( for H purity, 1 for purge gas) AK10 4 (H purity) AK103 (H purity) AK104 (H purity) Relay contacts Single pole changeover Rating 50 V AC 50 V DC max. 3 A AC 3 A DC max. Loading (non-inductive) 750 VA 30 W max. (inductive) 75 VA 3 W max. Insulation kv RMS contacts to earth (ground) Remote range indication Rating 50 V AC 300 V AC max. 150 ma AC 150 ma AC max. No. of set points AK101 3 ( for H purity, 1 for purge gas) AK10 4 (H purity) AK103 (H purity) AK104 (H purity) Set point adjustment Programmable Set point hysteresis ±1 % fixed Local set point annunciation Red LED Retransmission No. of retransmission signals AK101 fully isolated (1 for H purity, 1 for purge gas) AK10 fully isolated AK103 1 fully isolated AK104 1 fully isolated (H purity) Output current 0 to 10 ma, 0 to 0 ma or 4 to 0 ma programmable Accuracy ±0.5 % FSD ±0.5 % reading Resolution 0.1 % at 10 ma, 0.05 % at 0 ma Max. load resistance 750 Ω (0 ma max.) * Note. Purge gas options include: CO (carbon dioxide) N (Nitrogen) Ar (Argon)

10 AK100 SERIES ATEX COMPLIANT GAS ANALYZER SYSTEM DS/AK100-EN REV. O Specification 434 power supply unit Approvals CENELEC approved [Ex ia Ga] IIC ( 0 C Ta +55 C) BASEEFA Certificate No. BAS 01 ATEX 7041 II (1)G EN61010-1:010 compliant Power supply 115 V AC 50/60 Hz (434501) or 30 V AC 50/60 Hz (434500) Power consumption 30 W max. Fuse rating T50 ma 50 V AC rated 1500 A HRC ceramic, 50 V AC rated 0 x 5 mm DC output 350 ma stabilized ±0.14 % Load conditions 1 Katharometer 13 Ω max. Interconnecting cable Ω max. Ambient temperature range 0 to 55 C ( 4 to 131 F) Supply variations ±15 V (115 V supply) or ±30 V (30 V supply) 46 to 64 Hz Regulation Within ± 0.5 % for: Load variation of ± 15 % Supply variation of ± 15 % Ambient temperature variation of ± 0 C (36 F) ±4 Hz frequency variation Ripple Less than 0.5 % of set output peak / peak across a 10 Ω load Stability Within ± 0.7 % of initial setting, over period of 1 month with load resistance, supply voltage and ambient temperature at nominal stated values Overall dimensions 160 x 170 x 110 mm (6.3 x 6.7 x 4.3 in.) Weight.1 kg (4.8 lb) approx. Environment Sheltered interior 6540 03 and 6548 000 katharometer analyzer panel Approvals CENELEC approved Ex ia Ga IIC ( 0 C Ta +55 C) BASEEFA Certificate No. BAS 01 ATEX 104 II 1G Model 6540 03 incorporating Model 6539 960 (H) or Model 6539 960 (purge gas) katharometer unit Model 6548 000 incorporating Model 6548 001 (H and purge gas) katharometer unit Power supply 350 ma DC, from 434500 or 434501 power supply unit Signal output 0 to 10 mv for each range (air in N 1.0 mv) Accuracy ± % of scale span, each range ± 5 % of scale span, air in N Dead time Typically 5 s Response time Typically 40 s for 90 % step change at katharometer (tubing and drying chamber introduce extra delays) Ambient temperature 55 C (131 F) max. 0 C (3 F) min. Sample connections Compression couplings: 6 mm OD tube (Model 6548-000) 8 mm OD tube (Model 6540-03) Sample pressure Minimum 15 mm HO Maximum 0.35 bar (gauge) Model 6540 03 Maximum 10 bar (gauge) Model 6548 000 Sample temperature 0 to 55 C (3 to 131 F) Normal sample flowrate 100 to 150ml/min. Maximum gas flowrate 50 ml/min Minimum gas flowrate 50 ml/min Outline dimensions 610 x 305 x 15 mm (4 x 1 x 6 in.) Weight 8.6 kg (18.9 lb) Environment Sheltered interior

AK100 SERIES ATEX COMPLIANT GAS ANALYZER SYSTEM DS/AK100-EN REV. O 11 Overall dimensions Dimensions in mm (in.) 610 (4) 57 ±0.3 (3.35 ±0.01) Gland for Ø7 to 10.5 (0.8 to 0.43) cable Outlet 19 (0.77) 50 (.04) 114 (4.65) 43 (1.75) 38 (1.55) 305 (1.45) 67 ±0.3 (10.9 ±0.01) 98 (4) Inlet Coupling for Ø 8 (0.33) tube Coupling for Ø 8 (0.33) tube 179 (7.3) 33 (9.5) 14 (0.57) 14 (0.57) 19 (0.77) 10 (0.41) 11 (4.57) 4 fixing holes Ø 10 (0.41) (0.08) Katharometer analyzer panel assembly (Model 6540 03) 610 (4) 57 ±0.3 (3.35 ±0.01) Gland for Ø7 to 10.5 (0.8 to 0.43) cable Outlet 50 (.04) 19 (0.77) Coupling for Ø 6 (0.4) tube 148 (6.04) 38 (1.55) 305 (1.45) 67 ±0.3 (10.9 ±0.01) 98 (4) Inlet Coupling for Ø 6 (0.4) tube 179 (7.3) 33 (9.5) 19 (0.77) 10 (0.41) 11 (4.57) 4 fixing holes Ø 10 (0.41) Katharometer analyzer panel assembly (Model 6548 000)

1 AK100 SERIES ATEX COMPLIANT GAS ANALYZER SYSTEM DS/AK100-EN REV. O Overall dimensions Dimensions in mm (in.) 630 (4.8) 600 (3.6) 110 (4.33) 515 (0.8) 40 (1.57) 95.0 %H IN AIR 1 3 478 (18.8) 38 (15.04) 95.0 %H IN CO 1 3 Hydrogen Purity & Purge Gas Monitor 4 mounting brackets Ø 10 (0.39) holes Display monitor cubicle 90 (11.84) 30 (1.) 7 (11.1) 160 (6.3) 110 (4.3) 140 (5.5) 83 (3.7) 36 (14.8) Katharometer intrinsically safe circuits Cable entries Power and signal conventional circuits Mounting panel thickness 0 0 (0 0.8) Mounting panel display face 345 (14.08) Cable entry glands 110 (4.3) 117 (4.6) 4 fixing slots 0 (0.8) long x 10 (0.4) wide 170 (6.7) Model 6553 monitor Intrinsically safe power supply unit (Model 434500 or 434501)

AK100 SERIES ATEX COMPLIANT GAS ANALYZER SYSTEM DS/AK100-EN REV. O 13 Ordering information ATEX compliant gas analyzer for hydrogen-cooled alternators Display monitor unit Separate H purity and purge gas displays Dual 3-range displays (H purity and x purge gas) Single 3-range (H purity and x purge gas) Single hydrogen purity display Hydrogen purity range 80/85 % to 100 % 100 % to 85 % (does not conform to ATEX directive) 100 % to 80 % (does not conform to ATEX directive) Purge gas None (AK104 only) CO Argon Nitrogen (AK101 only) Gas analysis panel * None Low pressure and flame traps for vent to atmosphere 0.35 barg (5 psi) max. High pressure for closed loop 10 barg (145 psi) max. Cubicle Without cubicle With cubicle plus isolator With cubicle plus isolator plus MCBs and power supply indicators Gas sample flow alarm (available only with cubicle option) Not fitted 1 flow alarm fitted AK103 and AK104 (single gas analysis panel versions) flow alarms fitted AK101 and AK10 (dual gas analysis panel versions) Katharometer power supply *** None 115 V 50 / 60 Hz 30 V 50 / 60 Hz Special feature None Special System labels and instruction manuals** English French German Polish * gas analysis panels are required for AK101 and AK10 ** Check with factory for availability *** katharometer power supplies are required for AK101 and AK10 AK10 X/ X X X X X X X 1 3 4 1 3 0 1 3 0 3 0 3 0 1 0 1 0 9 1 3 7

14 AK100 SERIES ATEX COMPLIANT GAS ANALYZER SYSTEM DS/AK100-EN REV. O Notes Sales Service

AK100 SE RIE S AT EX COMP LI AN T GAS ANALY ZE R SYSTE M DS/AK100-E N RE V. O 15

ABB Limited Measurement & Analytics Oldends Lane Stonehouse Gloucestershire GL10 3TA UK Tel: +44 (0)1453 86 661 Fax: +44 (0)1453 89 671 Mail: instrumentation@gb.abb.com ABB Limited Measurement & Analytics 15 E. County Line Road Warminster PA 18974 USA Tel: +1 15 674 6000 Fax: +1 15 674 7183 abb.com/measurement We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. 017 ABB All rights reserved 3KXA834101R1001 DS/AK100-EN Rev. O 1.017